| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC 121004 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹32.3 L+₹1.6 L (5.24%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹32.6 L+₹1.9 L (6.21%)Rejected-Finance 31 CHAIRMAN KARUPPANA THEVAR STEET SULUR COIMBATORE 641 402 | COIMBATORE | TAMIL NADU | 641402 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹32.9 L+₹2.2 L (7.22%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹34.2 L+₹3.5 L (11.3%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹30.4 L
EMD Value
₹60,800
Closing Date
13 Oct 2021, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVISION OF ILLUMINATED MANDATORY INFO SIGN BOARDS IN AIRCRAFT MANOEUVRING AREA AT AF STN SULUR
2021_MES_477414_1
8449/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹60,800
Yes
3 Nov 2021
23 Sept 2021
14 Oct 2021
23 Sept 2021
13 Oct 2021
7 Oct 2021
23 Sept 2021 - 6 Oct 2021
Amount
SCHEDULE A BOQ
Supply, Installation, testing and commissioning of LED based aircraft guidance/mandatary/informative signage board made out of 2mm thick anodized aluminum sheet having minimum width of 150mm and supported at back side by 50mm dia die cast aluminum pipe for separation and frangible coupling as per ICAO standards duly fixed with one alphapatic letter in one board of area not less than 0.54 sqm using 4mm thick glare free polycarbonate sheet at front and back of board having Light source of 0.5 W or equivalent assembled on each board with required PCB with highly luminous having long life ie not less than 50,000 Hrs. complete all as per ICAO standards/ Annexure14 Volume I and as per specifications given below:
(a) The signage board should be installed in base of 150mm thick Plain cement concrete(1:2:4) type B1using 20mm graded stone aggregates (for legs) including necessary excavation.
(b) The concrete base and leg foundation should be 20-25mm above the ground level and shall be chamfered from the concrete base to not less than 30cm below the strip surface area.
( c) Suitable stainless steel bolts with templates should be fixed in the concrete where ever signage legs are to be mounted.
(d) Efficiency of LED shall have delivered minimum output 100 lumens per watt and colour temperature should be more than 5000 Kelvin with proper heat dissipation.
(e)These aluminum PCB’s should be placed across the length of the board in order to ensure uniform distribution of light across the board.
(f)The signage boards with different length shall be suitable for operation on series circuit at variable current from 2.8Amp -20/ 6.6Amp (brightness of the signage should be constant with current variation).
(g) All the signage shall have letters and symbols made by computerized cutting of vinyl and pasting on the polycarbonate sheet from inside/outside of the sign face of required color(Double sided)
(h) Supply of 65W 6.6 / 6.6 A 5000 Volts 50Hz isolating transformer encapsulated in polyester resin finally moulded with neoprene rubber as required and Installation of 65W 6.6 / 6.6 A 5000 Volts 50Hz isolating transformer encapsulated in polyester resin finally moulded with neoprene rubber required
(j)Supply and Installation of Secondary 2.5 sqmm/2.5 mtr long
Description all as per sl item No 2 here in above but area not less than 1.25 sqm in each board for fixing the word "APRON→"
Supply and fix 5 KV, Cu grade Primary Connector Kit suitable for field attachment with 5 KV grade PVC insulated PVC sheathed/ XLPE insulated cable single core 6 Sq.mm copper conductor cable conforming to the relevant IS specification etc. complete as required and Installation of 5 KV, Cu grade Primary Connector Kit suitable for field attachment with 5 KV grade PVC insulated PVC sheathed/ XLPE insulated cable single core 6 Sq.mm copper conductor cable conforming to the relevant IS specification etc. complete as required.
Supply & Installation of Secondary Connector Kit complete all as specified and as directed.
Supply and fix single core 6 Sqmm,5KV grade, PVC/XLPE insulated & PVC sheathed stranded copper conductor Airport lighting cable confirming IS 1554 (Part-II)/IS 7098 (Part- II) with upto date amendment and confirming to particular specification etc. as required. Note: The unit rate quoted is deemed to be inclusive for Laying of PVC Insulated / XLPE insulated and PE sheathed, copper conductor unarmoured airfield lighting cable directly in trench including necessary excavation, sand cushioning, protective covering and refilling the trench etc.
Supply and fix HDPE pipe of 63 mm OD of PE 63 PN 4 complete with all fittings & accessories laid in ground (80 cm below ground level) including necessary excavation and refilling the trench after laying Pipe etc., with and including Provision of 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing cable as required complete all as specified and as directed.
Supply and fix cast iron isolating Transformer housing box, water tight round type, metal container of outside size 330 mm dia, height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick, cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformer, power cable and having hole as per site requirement at the periphery, centre 75 mm above bottom surface suitable to receive 50 mm dia HDPE/medium class G.I pipe and one no of suitable hole to receive 15mm B class G.I pipe for loop earthing as required. The box should have two SS earh bolts of M10x40 mm tapped inside near the hole (4" away from hole centre) and having drain hole at the bottom suitably tapped to receive 15mm dia GI pipe and having clear opening of 220 mm at the top surface and 06 Nos. M10 tapped hole having centre to centre distance of 260mm alongwith bolts as required as per the drawings & Installation of Transformer Housing Box with a base concrete of 1:3:6 of size 630x630x100mm thick all-round concrete of 1:2:4, 150mm thick, the top slopped with 1:2:4 cement concrete including providing and fixing 250mm long 15mm dia. "B" class GI pipe with check nut for drainage of water including excavation of side shoulder and refilling etc. complete as required.
pk janardhanan
kaarthic builders
M/s Shana Constructions
K T ASSOCIATES
p.chinnasamy
A.GOVINDARAJ
Lucky Enterprises
devan enterprises
KUMAR AGENCIES
T C KARUNANITHI
KSR AND COMPANY
VARGHESECHACKO AND CO
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .