Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹33.5 L+₹2.8 L (9.04%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹33.9 L+₹3.1 L (10.1%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹34.7 L+₹4.0 L (12.9%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹36.9 L+₹6.1 L (19.9%)Rejected-AOC C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | L5 | Rejected-AOC Rejected |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
25 Mar 2023, 5:00 pmClosed
GARRISON ENGINEER GOMANATAK
GARRISON ENGINEER GOMANTAK VASCO DA GAMA PIN 403802
Spl Rep of Air conditioned Non Explosive Store House P9 NAD Goa Spl Rep Replacement of Ceiling Fans and Geysers against BER at NOFRA Provision of 02 Nos Electric Driven Pump alongwith Pipeline connected Accessories at NCB under GE Gomantak Vasco
2023_MES_583505_1
8503/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
VASCO DA GAMA
Refer tender documents
8 documents required · 8 mandatory
₹500
GE GOMANTAK
₹83,000
Yes
28 Apr 2023
28 Feb 2023
27 Mar 2023
28 Feb 2023
25 Mar 2023
13 Mar 2023
Amount
Dismantling Plain or corrugated steel sheeting,any gauge, thickness, includingNainital or similar pattern roof coverings
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F Rolled mild steel Roof trusses (framed), trussed purlins crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. GDE Fe410-0 or Fe 310-O
Applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome
Dismantling ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
S&F Anodised aluminium snap grid frame work for false ceiling all as specified size of grid 605x605mm.
S&F hangers 6mm GI(Up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long complete all as specified for false ceiling all as specified .
Supply & Fixing 10 mm thick PVC insulation panels in ceiling board with EPS of net to 1mm printed PVC sheet suitably placed in false ceiling grid all as per specification and drawing
Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles.
M&L for Pre-cast cement concrete type C1 (1:3;6) block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:4) complete all as specified and as directed.
Taking down cement plaster on brick work or stone walls including racking out joints ,hacking for key,scrubing down with water etc
M & L 15 mm thick rendering on fair faces of concrete in CM 1:6 finish the surface even & smooth without using extra cement complete all as specified and directed
M & L 15 ( 10+5) mm thick rendering in two layer on fair faces of concrete in CM 1:4 finish the surface even & smooth without using extra cement complete all as specified and directe( NOTE : II nd coat 5mm thick with WPC )
Supply only Liquid water proofing compound.
Removing loose concrete/plaster upto sound stratum of ceiling , chajjas, cloumns and beams and cleaned the slurface with water using water jet etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new surfaces and applying three coats of white wash on wall.
M & L preparation of new plasterd surfaces on wall and applying two coats of cement base paint over one coat of primer all as specified and directed by Engr in charge.
Material and labour for preparation of old decorated plastered surfaces of walls including cornices and applying one coat of white wash.complete all as specified and directed by Engr-in-charge. .
Material and labour for preparation of old decorated surfaces of walls, chajjas, fascia and roof projection etc,filing cracks and applying one coat of cement based paint of approved colour/shade complete all as specified and directed by Engr-in-charge. (Note : The unit rate quoted shall deemed to include removal of all vegetation)
Taking out the rolling shutters of any size , including top cover guide channel etc.,
S&F Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type
M&L for preparation of Old untreated steel surfaces of any description and applying one coats of Aluminium paint over a coat of primer.
Taking down chowkats or frames not exc. 1.5 sq.m. each with shutters (without taking off shutters from the frames)
M&L for Steel ventilator with top hung shutter including hinges, steel peg stay, complete
Demolition of cement concrete in floor and pavinngs nexc 15 cm thickness (below ao above ground level all as specified and directed.
M&L Hardcore broken stone or boulders of gauge exc. 63 mm but n exc 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to true surface
M/L for 40mm thickCement concrete type B-1, 1:2:4 (20mm graded aggregate)Finishing cement concrete surface even and smooth with out using extra cement.
M &L for preparation of old/new concrete floor surfaces of any description and in any posetion by brooming down/wire brushing and finally cleaned with compressed air to make the surfaces dust free and applying a coat of Nito mortar 30 or Nitoflor EU 5 to activator and smooth surfaces and applying two coats of epoxy resin floor coating paint Nito dlooe FC 150 with min 4mm thickness of paint coating 400 microns complete all as specified and directed.
Material & Labour for Cement concrete type B-1,1:2:4 (20mm graded) 40 mm thick PCC as in hard standing , ramp incl necessary form work etc complete.
Material & Labour for Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green
M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in plinth protection finished even and smooth using extra cement all as specified and directed.
Taking down chowkats or frames n exc 4 sqm each with shutters (without taking off shutters from the frames)
S&F powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F 5.5mm thick sheet glass,ordinary qauality and glazing with oil putty in square n exc 05 sqm in each pane
S&F 100 mm long stainless steel butt hinges fixed to door frame all as specified and directed
S&F 150mm long Aluminium anolised barrel tover bolts of extruded section and fixed
S&F 300mm long aluminium alloy anolised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section fixing bolts and sliding bolt of extruded section or cast aluminium alloy.
S&F 150mm long fancy type Aluminium handles , cast type anolised
Taking down carefully aluminium point wiring (light, fan, socket, bell or power) complete including all fittings and fixtures, removing, materials from site and making good disturbed surfaces of wall, ceilings etc.
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit and accessories concealed into wall by cutting of chases in wall/ceiling and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for Mylinc / Coral / Sleek model accessories etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light point controlled by one, one way switch 06 Amps. Note :- Rate is inclusive of Cutting/chases of wall/floor/ceiling
All as per item No 42 but 2/3 pin socket out let 5 Amps with 1.5 Sqmm on independent board.
All as per item No 42 here-in-before but for 2 in 1 three pin socket outlet 15/20 Amps on independent board with 4 Sqmm cable FRLS copper conductor multistranded including 4 sqmm PVC insulated and unsheathed FRLS copper conductor cable as earth continuity wire all as specified and directed by Engr-in-Charge.
Supply & Fixing modular switch 1 way 6A, 1 module, 230 volts.
Supply & Fixing modular switch one way 16 Amps, 1 module, 230 volts.
Supply & Fixing modular socket 6 Amps-2/3 pin combined, 2 module.
Supply & Fixing modular socket 6A/16A-2/3 pin combined, 2 module.
Supply and fix ceiling rose surfaces bakelite 65 x 50 mm three terminals including supply and fix PVC plate or square blocks.
Supply & fixing MCB, 6 to 32 Amps, single pole, C Series, 10 KA, 240 volts.
Supply and fixing MCB 63 Amps TPN, C Series, 10 KA, 415 volts.
Supply & Fix sheet metal enclosure DB, 6 way, TPN, double door factory made powder coated including bus bar and earth link connector, fixed in wall complete including part of job all as directed by Engr-in-Charge. Make : L&T/Legrand/C&S/Havells
Supply & Fixing MCB protected socket of 20 Amps with sheet metal enclosure including plug top of 20/25 Amps complete with one single pole 240V with 20 Amps MCB including disconnecting and removal of old one. Make : Havells Cat Part No. DHDMCSN0251020 or equivalent in Legrand/C&S/L&T
Supply & Fixing submain wiring with 2 Runs of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, FRLS copper conductor cable drawn in and including 25/32mm wide PVC conduit concealed with all accessories as required along with 1 run of 4 sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion all as directed by Engineer-in-Charge.
M&L earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI wire 4mm dia by means of bolts, nuts, check nuts & washers of GI or steel, and earth lead connected to main DB panel/meter box panel including necessary earth work and excavation of in any type of strata, chamber in PCC 1:2:4 type B-2 with CI cover, GI tubing 15mm dia light grade for protection of GI wire, GI tubing 20mm dia for watering etc all as per electrical plate no 5 of SSR part-I including provision of earthing test point & connecting to electrical equipments and testing on completion.
Supply & fixing wall mount fan 400mm sweep, 5 star rated (ISI marked) 230 volts including dismantling of old one depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Usha/Havells/Bajaj
Supply & Fixing GI pipe with suitable clamps on existing pole made of MS flat 40x5mm and 40mm dia GI pipe (light grade) bend to 1.2 mtr in length & in any shape with all fixing arrangement, nuts, bolts and washers etc and incl 2.5M copper conductor cable multistranded of 2.5 Sqmm PVC cable from overhead line to fitting connecting box etc complete and all as directed by Engr-in-Charge and including dismantling the rusted/ broken U/S old one.
Supply & Fixing LED street light fitting of 50 Watts Powder coated pressure die cast aluminium High Power LED as light source with heat resistant toughened glass with lens having IP66 protection, taking down the old one complete all as specified by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in hard/dense soil taking down UG cable any size.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 in depth getting out soft disintegrated rock for laying and taking down UG cable of any size
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engr-in-charge.
Supply & fixing UG LT cable XLPE insulated armoured heavy duty 1100 volts grade with aluminium conductor multistandarded of size 35 sqmm 3.5 core including centre gland, lugs, jointing materials etc laid in trenches or fixed it to wall and taking down old unserviceable cable.
Supply and laying High density polyethylene (HDPE) pipes of pressure rating 6 kgf/sq. cm of 50 mm dia laid in trenches or fixed in walls complete all as specified and directed.
Supply & fixing Brushless DC Motor (BLDC) ceiling fan 1200mm sweep, 5 star rated (ISI Marked), 230 volts least power consuming fan of 26W, having PCB Housing in the bottom canopy including connection rod as per existing size of length of GI pipe medium grade complete and disconnecting the old and depositing in MES store all as per specified and directed. Make : Usha/Havells/Bajaj/Crompton
Supply & installed storage type water heater (Geyser) capacity 25 Ltrs five star rating GMV type prefixing and grouting work for mounting nuts, bolts and washer etc in wall and connecting new inlet/outlet pipes electrical/earthing connections and carrying out testing for proper functioning including dismantling of old geyser and deposited in MES store yard all as specified and directed. Make : Havells/Bajaj/Venus/V-Guard
Supply only non return valve (gun metal) of size 16/20mm including removal of old ones all as specified and directed by Engr-in-Charge.
Supply and fix CPVC SDR 11 fittings union of size 16 mm dia bore including taking down old u/s GI union
Supply and fixing CPVC SDR 11 fittings union of size 20mm dia bore including taking down old u/s GI union
Supply and fix fire hydrant stand post with provn of single outlet conforming to IS 908
Supply and Install Booster pump 36 meter head discharge 900 LPM .(One running and one standby)
Supply and Fix Star delta Starter fully automatic suitable for 415 V AC For 15.0 HP Motor
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 3 Core ,4 Sq mm , 1100 Volts grade.
Supply and lay pipe galvanized/MS, “Heavy class”, including fittings, 63 mm (2½”) dia.
Supply and fix Valves, Sluice, flanged of class 1.6 PN , 65 mm (2½”) dia
Material and labour for valve pit chamber on existing chamber foundation with 230mm thick brick wall in CM 1:6, 75mm thick coping in PCC 1:2:4 (Type B1), 15mm thick plaster in CM 1:4 over all internal and external wall surface, 25x25x4mm thick MS Angle iron frame and 3.0 mm thick MS plate cover with hinges and necessary locking arrangements painting with two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed including dismantling and removal of existing damaged chamber except PCC foundation of internal size 1000 x1000 x 750mm .
Supply and fix hose box for keeping 2 Nos hose pipe of length 15 meter each, branch pipe.nozzle, coupling etc of MS sheet of Thickness 2.0 mm
Supply and fix 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903
Supply and fix 63 mm dia gun metal branch pipe with 12.5 mm nozzle conforming to IS 903
M&L for cross arm bracing support to clamps and back plate fabricated from structural steel section like angles channels flat etc including nuts bolts and washers welding bending cold or hot drilling holes for bolts if any shape and size and incl applying two coats of aluminium paint over one coat of red oxide primer including dismantling of old cross arms and all as directed by Engr-in-charge.
Supply and fix 4 Pole MCCB 12 to 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA .
S & F SS enclosure for MCCBs suitable to accommodate upto 70 sqmm 3.5 core XLPE cable complete . Make: L&T Cat NoCM90996OOOO or equivalent in Havells/scheider
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core
Supply and fix for DWC high density polyethylene pipes having dia 50mm having outer side wall corrugated and inner surface plain confirming to IS 14930 (Part-I & II) including straight/bend couplers to join two pipes for protection of underground cable laid in trenches/floor/fixed on pole/wall including all fittings and clamps as required complete all as specified and directed.
Mehta and Co.
AATREYA CONSTRUCTION
M/S G.N.POWAR
M/S P S BABU
M/s VEEJEE ENTERPRISES
Shree Ayyappa Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .