| 1 | L1₹51.2 LAccepted-AOC NO 6 1 ALAGAR PERUMAL KOIL MAIN STREET VADAPALANI CHENNAI 600 026 | CHENNAI | CHENNAI | TAMIL NADU | 600026 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹51.3 L+₹14,635.95 (0.29%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-Finance Being a Second lowest bidder | |
| 3 | L3₹65.2 L+₹14.0 L (27.4%)Rejected-Finance REVENUE WARD 8 8 2 220 GANDLA STREET SULLURU SULLURPET NELLORE ANDHRA PRADESH 524121 | SPSR NELLORE | ANDHRA PRADESH | 524121 | L3 | Rejected-Finance Being a 3rd lowest bidder | |
| 4 | L4₹68.2 L+₹17.0 L (33.3%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L4 | Rejected-Finance Being a 4th Lowest bidder | |
| 5 | L5₹70.6 L+₹19.5 L (38.1%)Rejected-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Being a 5th lowest bidder |
| Sl No | Description | Qty | Unit | BHARAT MULTITECH INDUSTRIES PVT LTD L5 | EVEREST ENGINEERING WORKS L4 | vijay kumar gupta and co L2 | Veera Electrical L1 | Chandra Reddy Electricals L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, erect, testing and commissioning of HT 11 KV Outdoor RMG Panel of Make:ABB complete all as per TNPDCL and to be designed, Manufactured and tested according to the latest version of relevant Indian standards, IEC standards & as per Technical Specification comprising of following accessories complete all as specified and directed including dismantling the old existing OCG RMG unit / two pole structure of any description and depositing the same completely to TANGEDCO .
(a) 11 KV, 630 Amps, 26.3 KA drawout type Vacuum Circuit breaker with 230V AC Motor and 110V DC closing/opening shunt, aux contact - 6 NO + 6 NC - 01 for outgoing
(b) 11 KV, 630 Amps, 26.3 KA Load Break switch - 02 Nos as incomers
(c) Potential Transformer, fixed type, Epoxy resin cast - 3 phase of ratio 11KV/110V, Core:15VA, CL 0.2 accy - 01 No
(d) Current Transformer, Epoxy resin cast - ***/5-5A, Core 1:0.2S/5V A per phase for Metering , Core 2: 5P20/15V A for protection - 03 Nos
(e) Overcurrent relay - 03 Nos, earth fault relay - 01 No, Master tripping relay - 01 No
(f) Digital Ammeter and Voltmeter - 01 No each | 3 | Each Job | 17,00,000 ₹51,00,000 | 16,72,500 ₹50,17,500 | 12,50,000 ₹37,50,000 | 12,42,000 ₹37,26,000 Lowest | 15,63,205 ₹46,89,615 |
| 1.01(g) Provision for TOD Meter - 01 No (h) RYB phase indicator lamps, ON/OFF/TRIP/Trip CKt healthy/Spring Charged indication Lamp - 04 Nos at incomer side and 08 Nos at outgoing side (j) TNC switch - 03 Nos (k) Space heater/illumination lamp - 03 Nos (l) Powerpack - 240V AC/110V DC - 01 No (m) Test Terminal block - 01 No (n) Copper busbars of size 50 mm X 10 mm mounted on epoxy resin cast insulators - 03 sets (o) Door switch for actuated CFL for panel illumination - 03 Nos (p) LV control fuses/power and control terminals alongwith complete control wiring - 03 Nos (q) MS Sheet enclosure suitable for with IP 55 Protection - 2 for LBS and 1 for VCB | ||||||||
| 2.00 | Supply, erect, testing and commissioning of HT 11 KV indoor RMG Panel of Make:ABB complete all as per TNPDCL complete all as per TNPDCL and to be designed, Manufactured and tested according to the latest version of relevant Indian standards, IEC standards & as per Technical Specification comprising of following accessories complete all as specified and directed including dismantling the old existing OCB RMG unit /two pole structure of any description and depositing the same completely to TANGEDCO .
(a) 11 KV, 630 Amps, 26.3 KA drawout type Vacuum Circuit breaker with 230V AC Motor and 110V DC closing/opening shunt, aux contact - 6 NO + 6 NC - 01 for outgoing
(b) 11 KV, 630 Amps, 26.3 KA Load Break switch - 02 Nos as incomers
(c) Potential Transformer, fixed type, Epoxy resin cast - 3 phase of ratio 11KV/110V, Core:15VA, CL 0.2 accy - 01 No
(d) Current Transformer, Epoxy resin cast - ***/5-5A, Core 1:0.2S/5V A per phase for Metering , Core 2: 5P20/15V A for protection - 03 Nos
(e) Overcurrent relay - 03 Nos, earth fault relay - 01 No, Master tripping relay - 01 No
(f) Digital Ammeter and Voltmeter - 01 No each | 1 | Each Job | 17,00,000 ₹17,00,000 | 16,21,750 ₹16,21,750 | 12,50,000 ₹12,50,000 | 11,70,000 ₹11,70,000 Lowest | 15,63,205 ₹15,63,205 |
| 2.01(g) Provision for TOD Meter - 01 No (h) RYB phase indicator lamps, ON/OFF/TRIP/Trip CKt healthy/Spring Charged indication Lamp - 04 Nos at incomer side and 08 Nos at outgoing side (j) TNC switch - 03 Nos (k) Space heater/illumination lamp - 03 Nos (l) Powerpack - 240V AC/110V DC - 01 No (m) Test Terminal block - 01 No (n) Copper busbars of size 50 mm X 10 mm mounted on epoxy resin cast insulators - 03 sets (o) Door switch for actuated CFL for panel illumination - 03 Nos (p) LV control fuses/power and control terminals alongwith complete control wiring - 03 Nos (q) MS Sheet enclosure suitable for with IP 55 Protection - 2 for LBS and 1 for VCB | ||||||||
| 2.02Note for ser item NOs 1 and 2: Quoted rate for above items shall deemed to be inclusive for the following : (a) Charges towards transportation, erecting, testing and commissioning complete (b) Charges towards dismantling the old existing OCB RMG unit / two pole structure and depositing to TANGEDCO (c) Charges towards obtaining TANGEDCO approval and factory inspection and MRT testing complete | ||||||||
| 3.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil for laying cables / pipes / erection of poles etc all as specified and as directed. | 10.2 | Cum | 650 ₹6,630 | 300 ₹3,060 | 200 ₹2,040 Lowest | 333 ₹3,396.6 | 450 ₹4,590 |
| 4.00 | Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed. | 8.37 | Cum | 200 ₹1,674 | 45 ₹376.65 Lowest | 100 ₹837 | 135 ₹1,129.95 | 200 ₹1,674 |
| 5.00 | Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed. | 0.21 | Cum | 250 ₹52.5 | 60 ₹12.6 Lowest | 180 ₹37.8 | 270 ₹56.7 | 1,000 ₹210 |
| 6.00 | Labour for filling the fine seived excavated dry soil laid to the required thickness in trench as a cushioning to cable complete all as specified . Note :- Thickness shall be measured after punning. | 1.62 | Cum | 4,000 ₹6,480 | 250 ₹405 | 800 ₹1,296 | 180 ₹291.6 Lowest | 200 ₹324 |
| 7.00 | Supply and laying reinforced precast concrete cable cover of size 300mm x 180mm x 40mm, class HV, type 1 with peak, complete all as specified | 100 | Each | 38 ₹3,800 Lowest | 70 ₹7,000 | 60 ₹6,000 | 72 ₹7,200 | 100 ₹10,000 |
Tender Value
₹94.7 L
EMD Value
₹3.0 L
Closing Date
17 Dec 2025, 6:00 pmClosed
Shri Vishal Garg,IDSE,SE,SAG
CWE Chennai Pallavan Sallai Chennai-02
IMPROVEMENT OF HT CONTROL GEARS SYSTEM IN PGOE, PGEPTA AND SOL SUBSTATION UNDER GE CHENNAI
2025_MES_740474_1
88496/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Chennai
As per Tender Documents
8 documents required · 8 mandatory
₹1,000
GE Chennai
₹3.0 L
Yes
20 Feb 2026
19 Nov 2025
19 Dec 2025
19 Nov 2025
17 Dec 2025
10 Dec 2025
Amount
Supply, erect, testing and commissioning of HT 11 KV Outdoor RMG Panel of Make:ABB complete all as per TNPDCL and to be designed, Manufactured and tested according to the latest version of relevant Indian standards, IEC standards & as per Technical Specification comprising of following accessories complete all as specified and directed including dismantling the old existing OCG RMG unit / two pole structure of any description and depositing the same completely to TANGEDCO . (a) 11 KV, 630 Amps, 26.3 KA drawout type Vacuum Circuit breaker with 230V AC Motor and 110V DC closing/opening shunt, aux contact - 6 NO + 6 NC - 01 for outgoing (b) 11 KV, 630 Amps, 26.3 KA Load Break switch - 02 Nos as incomers (c) Potential Transformer, fixed type, Epoxy resin cast - 3 phase of ratio 11KV/110V, Core:15VA, CL 0.2 accy - 01 No (d) Current Transformer, Epoxy resin cast - ***/5-5A, Core 1:0.2S/5V A per phase for Metering , Core 2: 5P20/15V A for protection - 03 Nos (e) Overcurrent relay - 03 Nos, earth fault relay - 01 No, Master tripping relay - 01 No (f) Digital Ammeter and Voltmeter - 01 No each
(g) Provision for TOD Meter - 01 No (h) RYB phase indicator lamps, ON/OFF/TRIP/Trip CKt healthy/Spring Charged indication Lamp - 04 Nos at incomer side and 08 Nos at outgoing side (j) TNC switch - 03 Nos (k) Space heater/illumination lamp - 03 Nos (l) Powerpack - 240V AC/110V DC - 01 No (m) Test Terminal block - 01 No (n) Copper busbars of size 50 mm X 10 mm mounted on epoxy resin cast insulators - 03 sets (o) Door switch for actuated CFL for panel illumination - 03 Nos (p) LV control fuses/power and control terminals alongwith complete control wiring - 03 Nos (q) MS Sheet enclosure suitable for with IP 55 Protection - 2 for LBS and 1 for VCB
Supply, erect, testing and commissioning of HT 11 KV indoor RMG Panel of Make:ABB complete all as per TNPDCL complete all as per TNPDCL and to be designed, Manufactured and tested according to the latest version of relevant Indian standards, IEC standards & as per Technical Specification comprising of following accessories complete all as specified and directed including dismantling the old existing OCB RMG unit /two pole structure of any description and depositing the same completely to TANGEDCO . (a) 11 KV, 630 Amps, 26.3 KA drawout type Vacuum Circuit breaker with 230V AC Motor and 110V DC closing/opening shunt, aux contact - 6 NO + 6 NC - 01 for outgoing (b) 11 KV, 630 Amps, 26.3 KA Load Break switch - 02 Nos as incomers (c) Potential Transformer, fixed type, Epoxy resin cast - 3 phase of ratio 11KV/110V, Core:15VA, CL 0.2 accy - 01 No (d) Current Transformer, Epoxy resin cast - ***/5-5A, Core 1:0.2S/5V A per phase for Metering , Core 2: 5P20/15V A for protection - 03 Nos (e) Overcurrent relay - 03 Nos, earth fault relay - 01 No, Master tripping relay - 01 No (f) Digital Ammeter and Voltmeter - 01 No each
(g) Provision for TOD Meter - 01 No (h) RYB phase indicator lamps, ON/OFF/TRIP/Trip CKt healthy/Spring Charged indication Lamp - 04 Nos at incomer side and 08 Nos at outgoing side (j) TNC switch - 03 Nos (k) Space heater/illumination lamp - 03 Nos (l) Powerpack - 240V AC/110V DC - 01 No (m) Test Terminal block - 01 No (n) Copper busbars of size 50 mm X 10 mm mounted on epoxy resin cast insulators - 03 sets (o) Door switch for actuated CFL for panel illumination - 03 Nos (p) LV control fuses/power and control terminals alongwith complete control wiring - 03 Nos (q) MS Sheet enclosure suitable for with IP 55 Protection - 2 for LBS and 1 for VCB
Note for ser item NOs 1 and 2: Quoted rate for above items shall deemed to be inclusive for the following : (a) Charges towards transportation, erecting, testing and commissioning complete (b) Charges towards dismantling the old existing OCB RMG unit / two pole structure and depositing to TANGEDCO (c) Charges towards obtaining TANGEDCO approval and factory inspection and MRT testing complete
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Labour for filling the fine seived excavated dry soil laid to the required thickness in trench as a cushioning to cable complete all as specified . Note :- Thickness shall be measured after punning.
Supply and laying reinforced precast concrete cable cover of size 300mm x 180mm x 40mm, class HV, type 1 with peak, complete all as specified
Supply and Lay in trenches XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm 3 core complete all as specifed .
S&F in repairs indoor type cable end termination joint kit heat shrinkable type for HT XLPE 11000 volt grade cable of size 95sqmm x 3 core and connecting the cable with the load and testing complete all as specified and as directed
S&F in repairs Outdoor type cable end termination joint kit heat shrinkable type for HT XLPE 11000 volt grade cable of size 95sqmm x 3 core and connecting the cable with the load and testing complete all as specified and as directed
M&L for earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion all as specified and directed . Note : (a) The quoted rate shall include for earth work excavation in any type of soil ,PCC (1:3:6) type C1 champer pit , RCC 1:2:4 type B-1 cover slab 50mm thick with and including reinforced with 8 mm dia CTD bars @ 150mm C/C both ways, funnel with 15mm bore GI watering pipe, 20mm dia bore GI protection pipe wire mesh and GI lugs including writing the details such as date of test, name of machine and earth valu etc on earth chamber with synthetic enamel paint
vijay kumar gupta and co (BID ID -3500026)
Chandra Reddy Electricals (BID ID -3500716)
EVEREST ENGINEERING WORKS (BID ID -3500589)
BHARAT MULTITECH INDUSTRIES PVT LTD (BID ID -3500391)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
88496TENDER.pdf
Tender Documents • 1.11 MB
BOQ_829150.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .