GARRISON ENGINEER (AF) THOISE
GARRISON ENGINEER (AF) THOISE 19 FBSU, c/o 56 APO, PIN 937219
REPAIR REPLACEMENT OF LT UG CABLE JUNCTION BOX AND EXTERNAL ELECTRIFICATION AT AF STN THOISE UNDER GE AF THOISE
2022_MES_552331_1
GEAF/T-30/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER (AF) THOISE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Thoise
₹50,000
Yes
31 Oct 2022
17 Sept 2022
10 Oct 2022
17 Sept 2022
8 Oct 2022
24 Sept 2022
Amount
Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth for manholes, sewage line etc not exc 10 sqm on plan and getting out in hard /dense soil complete all as specified and directed by Enginer-in-Charge.
Returning filling in including spreading levelling, watering and well ramming in layer each not exc. 25 cm thick in a Hard/dense soil complete all as specified and directed by Enginer-in-Charge.
Removing excavated material (soils) not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed by Enginer-in-Charge.
M&L for in repair / replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 2-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends complete all as specified and directed by Enginer-in-Charge.
All as per BOQ Srl Item No 4.00 above but of size cross-sectional area 16.0 Sqmm, 4-core complete all as specified and directed by Enginer-in-Charge.
All as per BOQ Srl Item No 4.00 above but of size cross-sectional area 25.0 Sqmm, 4-core complete all as specified and directed by Enginer-in-Charge.
All as per BOQ Srl Item No 4.00 above but of size cross-sectional area 35.0 Sqmm, 4-core complete all as specified and directed by Enginer-in-Charge.
All as per BOQ Srl Item No 4.00 above but of size cross-sectional area 50.0 Sqmm, 3.5-core complete all as specified and directed by Enginer-in-Charge.
All as per BOQ Srl Item No 4.00 above but of size cross-sectional area 70.0 Sqmm, 3.5-core complete all as specified and directed by Enginer-in-Charge.
All as per BOQ Srl Item No 4.00 above but of size cross-sectional area 95.0 Sqmm, 3.5-core complete all as specified and directed by Enginer-in-Charge.
All as per BOQ Srl Item No 4.00 above but of size cross-sectional area 120.0 Sqmm, 3.5-core complete all as specified and directed by Enginer-in-Charge.
M&L for PCC cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and directed. Note:-Excavation and earth work to be measured and paid for separately
Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness of 18 cm shall be measured for payment purpose only.
S & F in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor type termination heat shrinkable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185-300 sqmm complete all as specified and directed by Enginer-in-Charge. Make: Denson/ M Seal/ Raychem
S & F in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed by Enginer-in-Charge. Make : Denson/ M Seal/ Raychem
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider cat part No- LV426167 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens/ Havells.
All as per BOQ Srl Item No 16.00 above but of size Capacity 200 Amps with Breaking Capacity 25 KA complete all as specified and as directed by Engineer-In-Charge.
All as per BOQ Srl Item No 16.00 above but of size Capacity 300 Amps with Breaking Capacity 25 KA complete all as specified and as directed by Engineer-In-Charge.
All as per BOQ Srl Item No 16.00 above but of size Capacity 630 Amps with Breaking Capacity 45 KA complete all as specified and as directed by Engineer-In-Charge.
Attending day to day complaints for maintenance and repair of LT Network of any type and any specifications or any accessories related to Electric Supply of any descriptions, fitted/ fixed on poles, buildings or watching towers of any heights and any location, and re-fixing the same after necessary repairs/ replacement of defective parts including rectifying the same as per directions by concerned JE E/M and Engineer-In-Charge, at various locations, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of T&P, ladder or mechanical lift shall be deemed included in quoted rate. (ii) Supply of spare parts of light fittings shall be measured and paid separately.
Note: The work under subject BoQ (item No. 1.00 to 21.00 ) are meant for maint of External Electric Supply in AF Stn Thoise under GE(AF ) Thoise. The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth working of External Electric Supply in the AF station. Contractor or his representative will daily attend the complaints at E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 1500/- per day shall be recovered from contractor's payment for each complaint so notified.
M/S V K TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .