SITC of AC units at 1st floor area of NTB, VIP,CIP, server room and PBBs at NTB at Khajuraho Airport.
2026_AAI_286735_1
AAI/Khajuraho/Engg. (Electrical)/NIT-04/2026-27/
Open Tender
Electrical Works
Item Rate
150 days
Khajuraho Airport
As per Tender Document
20 documents required · 20 mandatory
₹1,180
₹3.8 L
6 Aug 2026
6 Aug 2026
29 Aug 2026
7 Aug 2026
28 Aug 2026
7 Aug 2026
7 Aug 2026 - 12 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1VRV/VRF OUT DOOR UNITS Supply, Installation, testing & commissioning of variable refrigerent volume / flow modulur type Heat Pump (Heating & Cooling type) outdoor unit equiped with highly efficient hermetically sealed rotary /scroll type inverter compressor(s) with 16 HP onwards having multiple compressor, special heat exchanger, y branch unit support, auto check function for connection error, Refrigerant R-410A, with Variable refrigerant temperature, auto gas charging facility for proper gas charging / as per OEM, refrigerant cooled PCB for long life of PCB/as per OEM. The EER at 100% load shall not be less than 3.73 for 16 HP outdoor unit heat pump suitable to operate from 380-415 volt, 50 Hz,3 phase AC power supply complete with individual controller and fittings with factory wired, tested with all neccessary controls and filled with first charge of refrigerent before delivering at site , connection & termination including complete as per enclosed technical specifications. Outdoors units of the VRV system shall be compact air cooled type.The outdoor units shall be suitable to operate within an ambient temperature range of "-5 Deg C to 53 Deg C" in cooling mode; & "-15 Deg C to 15.5 Deg C" in heating mode. All Outdoor units above 16 HP should have atleast 2 condensor Fans with top discharge arrangement. The VRV/VRF units must be capable so that refrigerent piping between outdoor unit & the indoor units shall be extendable up to 165 Meter with maximum level difference between outdoor unit & indoor units of 90 m and level difference between two indoor units shall be maximum up to 30 Meter . The compressor should be OEM manufactured/ as per OEM of unit. Including supply and installation of painted suitable size and strength MS frame/stand for outdoor unit etc complete as required. | |||||
| 1.01 | 76 HP | 2 | Set | 1 | ₹2 |
| 2VRV/VRF OUT DOOR UNITS Supply, Installation, testing & commissioning of of variable refrigerent volume / flow modulur type Heat Pump (Heating & Cooling type) outdoor unit equiped with highly efficient hermetically sealed rotary/scroll type inverter compressor(s) , special heat exchanger, y branch unit support, auto check function for connection error, Refrigerant R-410A, with Variable refrigerant temperature, auto gas charging facility for proper gas charging/ as per OEM, refrigerant cooled PCB for long life of PCB/as per OEM.The EER at 100% load shall not be less than 3.60 for 6 HP out door unit heat pump suitable to operate from 380-415 volt, 50 Hz,3 phase AC power supply complete with individual controller and fittings with factory wired, tested with all neccessary controls and filled with first charge of refrigerent before delivering at site , connection & termination, including complete as per enclosed technical specifications. Outdoors units of the VRV system shall be compact air cooled type.The outdoor units shall be suitable to operate within an ambient temperature range of "-5 Deg C to 53 Deg C" in cooling mode; & "-15 Deg C to 15.5 Deg C" in heating mode. The VRV/VRF units must be capable so that refrigerent piping between outdoor unit & the indoor units shall be extendable up to 50 Meter with maximum level difference between outdoor unit & indoor units of 30 meter. The compressor should be OEM manufactured/as per OEM of unit. Including supply and installation of painted suitable size and strength MS frame/stand for outdoor unit etc complete as required. | |||||
| 2.01 | 6 HP | 2 | Set | 1 | ₹2 |
| 3SITC of Factory built and Site assembled floor mounted Vertical AHU with Top Discharge as mentioned below, Dx type double skin air handing units complete as per specifications and of following capacities. Double skin construction : Inner skin 0.8 mm GI and outer skin 0.6 mm thick precoated GI. Thickness of insulation- 45 mm CFC free PUF injected with density of 40+/-42 kg/cum. Frame work: Thermal break aluminium profile with thermal barrier & Coving. Unit Base: Heavy Duty GSS FA Al Damper: Manual Gear operated FA Damper with 10 micron filter. (Fresh air opening should have 10 micron pre-filter.) RA Al Damper: Manual Gear Operated RA damper. Fan Section: 1- Running DIDW Backward curved centrigugal Fan with suitable capacity IE-3 motor (The Fan Section to be provided with double glass view window, light fixtures and Limit switch), Screen protection door, fire proof double canvass connections (Fungal Resistant and Lint free). Drain pan : stainless steel duly insulated with 13 mm thick nitrile rubber / cross linked polyethylene Vertical AHU with TOP Discharge, 8 row deep Dx cooling coil. (Coil dia min. 12/15 mm) (Coil Surface area ≤ 500 FPM) Header Material : Copper No. of Fins per inch (FPI) 11 / 12 Coil Casing / Blank offs : SS-304, Independedt Pre Filter Section , SA section with manual gear operated SA damper., All dampers shall be Aerofoil & gear type with lock & graduation arrangement. Complete Units shall be mounted on suitably rated neoprene pads. AHU Kit: AHU Kits along with suitable starters | |||||
| 3.01 | Capacity - 15 TR/6000 CFM/60 mm Static | 8 | Set | 1 | ₹8 |
| 4VRV/VRF Ceiling mounted Indoor Unit Supply, Installation, testing & commissioning of VRV/VRF ceiling mounted type indoor Unit ( Cooling and heating type) of following capacity including fan section with airflow range from low to high 812 to 1600 CFM ,pre filters, DX coil section, safety devices , sensors for different features ,standard accessories etc. complete as required suitable to operate from 220 V to 240 V , 50 HZ, single phase power supply with corded remote control, fittings etc. , maximum noise level should not be more than 55 DBA . The unit shall have external asthetic panel for supply and return air etc. complete as required. It includes all the MS angle/ channel/GI threaded rod etc. of suitable size and strength , fastner , nut bolts, washers etc. drilling , cutting including all civil works and making same good complete to install the unit from the ceiling. | |||||
| 4.01 | 4.0 TR Four Way Cassette unit | 2 | Set | 1 | ₹2 |
| 5Supply, installation, testing and commissioning of following capacity Air-cooled Tower/ Standing Type Air Conditioner Unit (both indoor & outdoor complete) alongwith vibration isolator, as per latest BEE Standard fitted with 100% copper condensing unit comprising of sealed rotary type compressor with Inverter Technology and Non CFC refrigerant like R32/ R410A suitable for stabilizer free operation at 3ph, 415V, 50Hz AC supply etc. as required. | |||||
| 5.01 | 4.0 TR Tower AC unit | 2 | Set | 1 | ₹2 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.38 MB
TDVRF.pdf
Tender Documents • 5.95 MB
BOQ_334622.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].