Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC S NO 7 3 FLAT NO 4 HILL VIEW RESIDENCY LOHEGAON PUNE 411047 | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹11.5 L+₹79,057.50 (7.36%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹11.7 L+₹98,127.50 (9.14%)Rejected-Finance 25 13 1 AMBEGAON PATHAR PUNE 411046 | PUNE | MAHARASHTRA | 411046 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹12.9 L+₹2.1 L (19.8%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹13.4 L+₹2.6 L (24.5%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
29 Aug 2022, 6:00 pmClosed
GE (C) PUNE
Garrison Engineer (Central) Arjun Marg, Pune - 411 001
8331 REPAIR TO WATER PROOFING TREATMENT AND SUKEN FLOOR TREATMENT AND CERTAIN MISC WORKS TO CERTAIN BLDGS IN THE AREA OF AGE BR II GE (CENTRAL) PUNE
2022_MES_543828_1
8331 REPAIR TO WATER PROOFING TREATMENT AND SUKEN
Open Tender
Civil Works
Item Rate
120 days
GE (CENTRAL) PUNE
As per Tender NIT
9 documents required · 9 mandatory
₹500
GE (Central) Pune
₹30,000
Yes
25 Oct 2022
6 Aug 2022
31 Aug 2022
6 Aug 2022
29 Aug 2022
16 Aug 2022
Amount
Demolition of uneinforced cement concrete of any description and in any position on roof slab/sunken slab as in padding etc including removing rubbish off the premises complete all as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc including removing rubbish off the premises complete all as directed.
Dismantling of single layer mangalore pattern or similar tiles in roofing etc complete all as directed including removing u/s materials from site complete all as directed.
Dismantling of battens for tiles of any size including tilting fillets spacing exc.15 cm complete all as directed.
Dismantling of AC sheet corrugated, or semi corrugated in roof covering including removing u/s materials from site complete all as specified and directed.
Dismantling of plain or corrugated, steel sheeting, any gauge, thickness and including removing u/s materials from site complete all as specified and directed.
Dismantling of structural steel work including doors,gates but excluding framed Truss etc complete including removing u/s materials from site complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections, including removing from site complete all as specified and directed.
Taking down eaves gutter or RWP of any description / bore including removing from site of work complete all as directed.
Dismantling water tanks capacity exc 500 Ltr and n.exc 1000 Ltrs and removing from site complete all as directed.
M&L for PCC 1:2:4 type B0 using 12.5 mm graded agg as in PCC padding in roof kerbs or mud stops, rounded and chamfered on edges and on chajjas laid over RCC surface finished even and smooth without using extra cement and mixed with liquid water proofing chemicals all as specified and directed (Note : WPC shall be measured and paid separately)
M&L PCC (1:3:6) type B1 (using 20 mm graded stone aggregate) as in roof kerbs , rounded or chamfered on edges, including necessary form work complete all as specified and directed.
M&L for precast concrete solid block masonry exc 10 cm width with solid block of PCC (1:5:8) Gde C-5 and setting in CM 1:6 complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregates) finished even and smooth without using extra cement as in roof padding and similar items mixed with liquid water proofing chemicals complete all as specified and directed. Note: WPC shall be measured and paid seperately.
M&L for 40mm thick PCC type B1 1:2:4 (using 20mm graded stone aggregates) finished even and smooth without using extra cement as in roof padding/sunken portion and similar items mixed with liquid water proofing chmicals complete all as specified and directed. Note: WPC shall be measured and paid seperately.
M & L water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below and as directed by Engineer-in-Charge including taking down old waterproofing tratement. (a) M&L for 10mm thick plaster screed bed layer in CM 1:3 on concrete surfaces mixed with liquid water proofing chemical as per manufacturer's instruction. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.20kg/Sqm of area complete all as specified. (c) Laying APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 kg/Sqm and 3mm thick with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specifed & as directed by Engr in Charge. Note: WPC shall be measured and paid seperately.
M & L water proofing treatment to RCC sunken slab, walls, chhajjas etc, shall be carried out as specified below and as directed by Engineer-in-Charge including taking down old waterproofing tratement. (a) M&L for 10mm thick plaster screed bed layer in CM 1:3 on concrete surfaces mixed with liquid water proofing chemical as per manufacturer's instruction. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.20kg/Sqm of area complete all as specified. (c) Laying APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 kg/Sqm and 3mm thick with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE. complete all as specifed & as directed by Engr in Charge. Note: WPC shall be measured and paid seperately.
M&L for rendering 10mm thick in cement mortar 1:6 on brick surfaces finished even and smooth with a thin layer of sagol complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on brick/ stone surfaces finished even smooth with sponge finish complete all as specified and directed.
S&F pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and directed
S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, bent to shape as required and directed fixed with self tapping screws all as specified and directed
S&F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L type or J Type or cranked hook bolts and washers, in roofs, walls etc with grade of zine coating 275 etc complete all as specified and directed.
All as per item No 22 here-in-before but except sheetng of any thickness.
S & F Roof tiles,mangalore Pattern,interlocking at side joints,laid dry etc complete all as specified and directed.
All as per item No 24 here-in-before but except tiles.
S & F 2nd class hardwood battens for tiles, shingles etc sectional area n exc 15sqcm of size including tilting fillets clean dawn all as specified and directed
Fixing only batten obtained from dismantling under item no 4 here -in- before all as directed.
M&L for MS structural steel work, framed as in trusses, purlins, rafter, post etc. conforming to grade E-250 (Fe-410W, quality A) including shaped washers including necessary cutting required length, notching drilling, riveting and or welding or connecting with nut bolts with angle cleats, gusset plate and also erecting in true position complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, hoisted and fixed in position with connecting up pipes i.e. nipple socket / unions etc including 20 mm bore ball brass valve with polythene float and flynut complete all as specified and directed.
All as per item No 30 here-in-before but 1000 litres capacity tank.
Disconnecting existing tanks exc 1000 Ltr & n.exc 2000 lit capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position all as directed.
All as per item No 32 here-in-before but capacity of tank exc 500 and n exc 1000 litres.
S&F in repair Tubes, 20 mm bore 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repair 20mm dia gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 110mm bore PVC rain water pipe single socketed with rubber ring joints fixed to wall complete all as specified & directed
All as per item No 36 here-in-before but 75 mm bore.
S&F 110mm bore PVC bend any radius complete all as specified and directed.
All as per item No 38 here-in-before but 75 mm bore.
Supply only liquid water proofing chemicals.
M&L for preparing surface of wood and wood based materials, new of any description and girth and applying two coats of creosote oil complete all as specified and directed.
All as per item No 41 here-in-before but one coat on old surface.
M/S S H KHAN ENTERPRISES
Sai Construction
DIAMOND ENTERPRISES
M/s Asrani and sons
J D Contruction
M/S NAVNEET S MORDE
ANIL CONSTRUCTION CO.
Mourya Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .