Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.6 LAccepted-AOC | 1 | Accepted-AOC Accepted | |
| 2 | Rejected-Technical AT MQ 49 BODIYA BASTI KATHARA BOKARO JHARKHAND 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Not Evaluated as not L1 | |
| 3 | Rejected-Technical MAIN ROAD KATHARA BOKARO 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Not Evaluated as not L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Evaluated as not L1 |
Tender Value
Refer Docs
EMD Value
₹3,600
Closing Date
5 Dec 2022, 4:00 pmClosed
Staff officer ENM
Office of the staff officer EnM kathara Area
Renovation of Garden light and decorative light with electrical wiring of kitchen side of Guest house, Kathara Area
2022_CCL_263152_1
GMKTA/SOEnM/E-tender22-23/29
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Kathara Area
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,600
29 Mar 2023
23 Nov 2022
6 Dec 2022
24 Nov 2022
5 Dec 2022
24 Nov 2022
24 Nov 2022 - 1 Dec 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Group “C”)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire )
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire )
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (single pole and neutral)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)( 2+ 4 way/6 way double door)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amp switch
5/6 amps socket outlet
15/16 amps switch
15/16 amps socket
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Supplying and laying 25 mm X 6mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) Details of cost for 30 metres
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of1.1KV grade following size direct in ground including excavation and refilling the trench etc. as required(212+44)=256mtr
Providing of Circular LED surface ceiling light ( round )10 watt x220v
Providing of LED surface ceiling light size- 2’ X 2’ (square)
Providing of LED surface ceiling light size – 1’ X 1’(square)x 15 watt ,220volt
Providing of ICTP switch 63 Amp 415 v
Providing of Garden light fitting 10watt
Providing of Junction box
Providing of Cable clip (for 6 sq.mm cable)
Timer switch ( auto cell) 65 amps ( for street light control)
Providing of three core PVC copper cable size 6 sq.mm (armoured)1.1kv grade
Providing of Twin core PVC copper wire size 1.5 sq.mm ( for light connection) 14x2 =28mtr
Labour/fitting/fixing charges
Total impact of GST for the purpose of CTC
AASHISH ENTERPRISES
M/S P. L. CONSTRUCTION
M/S YOGENDRA KUMAR RAWANI
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_272190.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .