Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical HOUSE NO 13 SECTOR 4 TRIKUTA NAGAR JAMMU JAMMU JAMMU KASHMIR 180012 | JAMMU | JAMMU AND KASHMIR | 180012 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹3.7 L
Closing Date
17 Mar 2022, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2022_PWDJK_162389_1
Short e-NIT No.EDJ/258 of 2021-22 Dated 26-02-2022
Open Tender
Electrical Works
Item Rate
20 days
SMGS Hospital Jammu
please refer to NIT
2 documents required · 2 mandatory
₹0
Exempted
22 Mar 2022
26 Feb 2022
18 Mar 2022
27 Feb 2022
17 Mar 2022
27 Feb 2022
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing of 20/22 watt LED 4 feet tube light fitting/fixture aluminium housing with 2000 Lumens and min lumens efficiency 100 Lumens/watt P.F 70.95 THD < 16%
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole 5/6 Amp
Single pole and neutral 40 Amp
Triple pole and neutral 63 Amp
Supplying, fixing, installation, testing & commissioning of I/O Module Boxes
Supplying & drawing of UTP 4 Pair CAT-6 LAN Cable in the existing surface/recessed steel/pvc conduit as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply.
Ceiling fan 1200 mm sweep alongwith rod upto 1'-6" long
Supplying, installation, testing and commissioning of 2.0 Ton Split AC's inverter type (copper) (3 star) Hot & Cold type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. Indoor unit must be fitted on wall via clamps while outdoor units on MS powder coated wall stand. Make: Blue Star, Hitachi, Diakin, Mitsubishi, Voltas Warrantee.:- a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation.
Supplying, Installation, Testing & Commissioning of automatic voltage stabilzer copper wound wall mounted, rating single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Make (V Guard, , Electricfield, Automatic electric, Blue Bird) Warrantee.:- 2 Years from the date of installation.
Supplying & fixing of M.S Wall Stand duly powder coated for outdoor unit of Split AC
Supplying of drain pipe for indoor unit (Supreme) 3/4"
Extra length of copper pipe & cable of suitable size for outdoor unit.
Supply of 2 KVA /1800W True Online , DSP Controlled online UPS with 1 phase AC input and 1 phase AC output with 120 minutes backup with 12V SMF batteries Bank with Rack ( min. VAH required =4032 VAH) ,The UPS should be with IGBT Based Rectifier and Inverter and with LCD/LED display for monitoring of its status along with inbuilt Galvanic Isolation Transformer of Same OEM Make at input side. UPS should have following Features : UPS power factor : Input PF should be 0.99 AND output PF not less than 0.8, THDv :3% for Linear loads & < 5% for nonlinear loads, Efficiency: UPS efficiency should not less than 90% (without Iso.Tx) ,Communication interface :RS232/USB port and optional SNMP compatibility for remote Monitoring , Audible Alarm : Mains Failure/Low battery /UPS Warning /Overload/Fault & Bypass Mode , CERTIFICATIONS & Standard : ISO-9001-14001 Certified , CE, BIS certifications & ROHS Compliance and Performance Test (IEC 62040-3) . Compatibility with DG Genset , Built in Automatic Bypass Switch , Warranty : 2 Years on UPS and Batteries, Battery Make : Exide /Amaron-Quanta/ Panasonic Make Only, Preferred/Approved Brand : APC /Emerson – Vertiv / Legrand-Numeric. OEM should have own service center in the district (Need to furnish the service centre address & contact details of at least 2 engineers for better services.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .