Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
29 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Pawan Kumar CWE Bhopal
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
CONSTRUCTION OF ROOM (NEW) AND PROVISION OF GATE IN WAPL BLDG NO 103 AT TECH AREA TAKU CPE ITARSI UNDER GE BHOPAL
2023_MES_609276_7
83839/E8
Open Tender
Civil Works
Item Rate
270 days
BHOPAL
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹34,000
Yes
8 May 2024
4 Apr 2024
1 May 2024
4 Apr 2024
29 Apr 2024
11 Apr 2024
4 Apr 2024 - 11 Apr 2024
Amount
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Lump sum price worked out by the tenderer for Building Works as listed in Schedule ‘A’ Part-I(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for Excavation and Earth works as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for Internal Electrification as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for Internal Water Supply as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for External Electrification as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for External Water Supply as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for Road, Path and Culvert as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for Sewage Disposal as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for Fencing, Compound Wall and Gate as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately)
Schedule 'A' Part-X(Miscellaneous)
M & L for cutting galvanised mild steel pipe of nominal bore 80 mm, in position for and including insertion of new tee piece including necessary fittings and fixtures complete all as specified and as directed.
M & L for making road cutting surfaces good using 200 mm thick hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface and using cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 150 mm thick finished even and fair and using earth filling for remaining depth complete all as specified and as directed.
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Disconnecting, taking out old unserviceable under ground cable of rated voltage 6.35 kV/ 11 kV, upto any size of nominal cross sectional area of main conductor, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for reuse or for taking credit all as specified and directed by the Engineer-in-Charge.
Laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 6.35 kV/ 11 kV, three phase, earthed system, upto 4 core, screened, armoured power cable, upto any size of nominal cross sectional area of main conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
Disconnecting all existing connection with transfomer and taking down and shifting transformer from any substation under the GE to new location with help of Hydra (Recovery)/JCB/ Crane etc. and including installation at new location including connecting all connections, earthings, conductors, cables, nuts, bolts, washers etc. complete all as specified and as directed.
Supplying & laying in trenches, in road cutting and along pole 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 150, made of polyethylene (PE) material conforming to per IS16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS16098 (Part 2):2013 complete all as specified and as directed.
Supply and fix LLDPE Anaerobic Underground Septic Tank of capacity 2000 litres, 3 Nos of chambers, 2 Nos of manholes, made of rotation moulding application LLDPE materials having MFI ≥ 4.0, density ≥ 930 kg/m³, tensile stress at yield: ≥ 15 Mpa, tensile strain at yield: ≤ 25%, tensile strain at break: ≥ 80%, thickness of wall ≥ 10 mm including necessary inlet and outlet pipe of 2 metre length with submerged pipe tee, vent pipe of 2 metre length and 50 mm dia, designed to carry sewage and salvage water with upflow filter chamber including necessary excavation and earth works, footings of appropriate size and thickness in plain cement concrete works in cement concrete (M7.5) using 40 mm graded crushed stone aggregates complete all as specified and as directed.
M & L for construction of soakage well of size (1.8 metre dia X 3.0 metre effective depth) as per drawing No. CEBZ/TD/78/2011 sheet Nos 1/2 and 2/2 dated 01 Aug 2011 (Drawing of Chief Engineer Bhopal Zone) including necessary earth work in any type of soil, PCC lean concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in foundation, RCC M25(Design Mix) using 20 mm graded crushed stone aggregate as in slab, manhole cover in precast RCC M-25 (Design Mix), PCC band in M10(Nominal Mix) using 20 mm nominal size coarse aggregate, honeycomb brickwork in cement mortar (1:4), inlet pipe of cast iron of 150 mm nominal dia as per IS 1729: 2002 and length upto 4 metre each, reinforcement of grade as specified, other structural details as per drawings and specifications, loose filling in layers with brick bats of gauge 80 mm to 150 mm in bottom layer and of gauge 40 mm to 80 mm in top layer complete all as specified and as directed.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .