Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.1 LQualified Make: LUMINOUS
Model: Luminous online UPS 2KVA\3200VAh/60Min backup with 2 year warrenty B 921 GREEN FIELDS COLONY FARIDABAD 2821 121003 INDIA | FARIDABAD | HARYANA | 121003 | Make: LUMINOUS
Model: Luminous online UPS 2KVA\3200VAh/60Min backup with 2 year warrenty | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
3 May 2018, 6:00 pmClosed
Online UPS Online UPS ( 6 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA 2.0kva Technology MOSFET-PWM with inbuilt isolation transformer mosfet-pwmwithinbuilti solationtransformer Input Power single phase 160V - 260V sinewave
50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz singlephase230v-1sine wave50hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 1900 Warranty for UPS (Years) 2 1
2
3
4
5 Movable trolly for Batteries Without With
Without
Without trollery but with rack Warranty for battery 1 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for input and out put With With
Without Paralleling kit for synchronising With With
Without Installation and Commissioning Yes N/A 1/4 CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 N/A Voltage Regulation from no load to full load (%) </= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) >/=90% N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes N/A Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes N/A Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 Yes N/A 2/4 (reaffirmed 2007) at 55 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. R-410J5563 N/A Type Test Certificate date 08-11-20 17 N/A Name of Lab Bureau of Indian Standards N/A Address of Lab Manak Bhavan
9 Bahadur shah Zafar Marg
New Delhi-110002 N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anant Vaibhav 110010
Room NO 110 A
B bLock Hutments
Dara Shikoh Road 6 45 EMD Required No ePBG Required No
36040
GEM/2018/B/5133
Online UPS
Central Delhi, Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Online UPS ( 6 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA 2.0kva Technology MOSFET-PWM with inbuilt isolation transformer mosfet-pwmwithinbuilti solationtransformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz singlephase230v-1sine wave50hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 1900 Warranty for UPS (Years) 2 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Movable trolly for Batteries Without With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack Warranty for battery 1 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put With With | - | - | - |
| Without Paralleling kit for synchronising With With | - | - | - |
| Without Installation and Commissioning Yes N/A 1/4 CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 N/A Voltage Regulation from no load to full load (%) </= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) >/=90% N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes N/A Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes N/A Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 Yes N/A 2/4 (reaffirmed 2007) at 55 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. R-410J5563 N/A Type Test Certificate date 08-11-20 17 N/A Name of Lab Bureau of Indian Standards N/A Address of Lab Manak Bhavan | - | - | - |
| 9 Bahadur shah Zafar Marg | - | - | - |
| New Delhi-110002 N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anant Vaibhav 110010 | - | - | - |
| Room NO 110 A | - | - | - |
| B bLock Hutments | - | - | - |
| Dara Shikoh Road 6 45 EMD Required No ePBG Required No | - | - | - |
Exempted
4 May 2018
26 Apr 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_36040.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .