Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
2 Oct 2020, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2020_PWDJK_105388_1
Fresh e-NIT No.EDJ/76 of 2020-21 Dated 25-09-2020
Open Tender
Electrical Works
Item Rate
JK House Delhi Mumbai Amritsar
please refer to NIT
2 documents required · 2 mandatory
₹600
Yes
Executive Engineer PWD RandB Electric Div Jammu
₹10,000
Yes
9 Oct 2020
26 Sept 2020
3 Oct 2020
27 Sept 2020
2 Oct 2020
27 Sept 2020
Amount
Wet / dry Servicing of Split / Window Air Conditioners as required, including complete cleaning, checking cooling / heating, gas pressure etc.
Supply, erection, testing and commissioning of compressor suitable for following capacity and type of Air Conditioners with Gas charging and other required accessories to get A.C workable, including buy back of faulty compressor.
2 Ton split type A.C
2 Ton split type Inverter A.C
2 ton window type A.C
2 ton window type Inverter A.C
1.5 Ton split type A.C
1.5 Ton split type Inverter A.C
1.5 Ton window type AC
1.5 Ton window type Inverter A.C
Gas charging / Top up of following type Air Conditioners including replacing / repairing valve etc as required.
2 Ton split type Air conditioners
2 Ton split type Inverter Air conditioners
2 ton window type Air conditioners
2 ton window type Inverter Air conditioners
1.5 Ton split type Air conditioners
1.5 Ton split type Inverter Air conditioners
1.5 Ton window type Air conditioners
1.5 Ton window type Inverter Air conditioners
Providing and fixing of copper pipe of following sizes including brazing, insulation ect. on surface / in recess including repairing of walls, ceiling etc. as required
Providing and laying of flexible copper wire of following sizes on surface / in recess including including repairing of walls, ceiling etc. as required
2.5 sq mm 4 core
2.5 sq mm 6 core
Dismantling, shifting and reinstlling 1.5/2 Ton window Air conditioners at new Location.
Dismantling, shifting and reinstlling 1.5/2 Ton on split Air conditioners at new Location including gas top up.
Installation of 1.5/2 Ton window Air conditioners
Installation of 1.5/2 Ton split Air conditioners
Replacement of defective fan motor of following capacity and type of Air Conditioners
1.5 Ton Split A.C Outdoor
1.5 Ton Window A.C
2.0 Ton Split A.C Outdoor
2.0 Ton Window A.C
Replacement of defective capacitor of following capacity and type of Air Conditioners
1.5 Ton Split A.C
1.5 Ton Window A.C
2.0 Ton Split A.C
2.0 Ton Window A.C
Providing & fixing of Blades of following capacity and type of Air Conditioners
1.5 Ton Split A.C
1.5 Ton Window A.C
2.0 Ton Split A.C
2.0 Ton Window A.C
Providing & fixing of Blower drum of following capacity and type of Air Conditioners
1.5 Ton Split A.C
1.5 Ton Window A.C
2.0 Ton Split A.C
2.0 Ton Window A.C
Providing & fixing Grill cover of following capacity and type of Air Conditioners
1.5 Ton Window A.C
2.0 Ton Window A.C
Day-to-day maintance contract of various make of water cooler by using of following parts and gas charging etc. as required.
Supply, erection, testing and commissioning compressor suitable for 150/150 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable.
Supply, erection, testing and commissioning compressor suitable 40/80 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable.
Gas charging of drinking water cooler 150/150 ltr.
Gas charging of drinking water cooler 40/80 ltr.
Automatic Voltage stabilizer of following capacity suitable for following capacity and type of Air Conditioners
4 KW Copper wound wall/floor mounted for 1.5 ton A.C.
5 Kw copper wound wall/floor mounted for 2.0 ton A.C.
6 KW Copper wound wall/floor mounted for 2.0 ton A.C.
Repair of PCB of Split AC 1.5 Ton
Repair of PCB of Window AC 1.5 Ton
Repair of PCB of Split AC 2.0 Ton
Repair of PCB of Window AC 2.0 Ton
Replacement of PCB 1.5 Ton Split AC
Replacement of PCB 2.0 Ton Split AC
Replacement of PCB 1.5 Ton Window AC
Replacement of PCB 2.0 Ton Window AC
Supply, Fixing /erection, testing and commissioning of New Copper Condenser suitable for following capacity and type of Air Conditioners with Gas charging and other required accessories to get A.C workable, including buy back of old/damaged condenser.
1 Ton Split AC
1.5 Ton Split AC
2.0 Ton Split AC
0.75/1 Ton Window AC
1.5 Ton Window AC
2 Ton Window AC
Supplying & installation of following capacity and type 5 Star, Cold Air Conditioners with Full Copper Cooling Coil and Condensor, Ambient operating temperature range 21˚c to 50˚c. With Warranty as i) One Year for Complete AC. ii) 5 Year's for compressor replacement warranty.
1 Ton Split AC
1.5 Ton Split AC
2.0 Ton Split AC
1.5 Ton Window AC
2 Ton Window AC
Repair to RO / UV water purifier by way replacement of filter candle set /servicing.
Repair of PCB unit of RO / UV water purifier
SUPER COOL ENGINEERING WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .