| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC 0 CIVIL LINES TETARI BAZAR TETARI BAZAR NAUGARH SIDDHARTHNAGAR UTTAR PRADESH 272207 | SIDDHARTH NAGAR | UTTAR PRADESH | 272207 | L1 | Accepted-AOC Being L and reasonable | |
| 2 | L2₹21.6 L+₹4.6 L (27.1%)Rejected-Finance MAGADH COLONY ROAD NO 5 GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹24.4 L+₹7.4 L (43.5%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹24.4 L+₹7.4 L (43.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹24.7 L+₹7.7 L (45.6%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹53,000
Closing Date
4 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR Pin-273008
PROVISION OF CERTAIN SANCTIONED WORKS AT 4 AFSB VARANASI UNDER GE AF GORAKHPUR
2020_MES_396279_2
8747/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹53,000
Yes
2 Feb 2021
19 Dec 2020
5 Jan 2021
19 Dec 2020
4 Jan 2021
28 Dec 2020
60 days
Amount
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for PCC type B-2 1:2:4 using 40 mm graded aggregate as in foundation filling, bed blocks and mass concrete complete all as specified and directed.
S&F rolled mild steel work in tubular trusses including vertical member, rafter and purline including special shaped washer etc using ERW or induction butt welded tubes conforming to IS 1161-1979 graded ST-240 including cutting to dead length, notching, drilling riveting and/or welding & connecting with nuts & bolts complete all as specified.
S&F rolled mild steel section in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde E-250) quality-A complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick (BMT) of any colour having tensile strength of 550 Map as in roof covering/cladding to wall, fixing with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick (BMT) of any colour having tensile strength of 550 Map as in roof covering/cladding to wall, fixing with self tapping screws complete all as specified and directed.
M&L for preparation of previously untreated steel and iron surfaces of any description not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Surface dressing n.exc. 15 cm deep in soft/loose soil incl removal of brick/stone pieces, herbs, shrubs & vegetation and tree cutting in areas of construction complete all as specified and directed.
M&L for 75mm thick PCC type D-2 1:4:8 using 40 mm graded aggregate as in sub base of floor complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate as in floor laid in panels finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
S&F Mild steel, plain, black sheet 0.80 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, 5 to 10mm dia of neck exc 5cm and n-exc 10cm long complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc 0.5cum getting out, returning, filling in watering and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm thick in soft/loose soil, making good surface and disposal of surfaces spoil to a distance not exc 50 Mtrs complete all as specified and as directed.
M&L for preparation of previously untreated steel and iron surfaces of any description not otherwise described over 10 cm in width or girth and applying two coats of Black Japan paint over a coat of red oxide primer complete all as specified and directed.
S&F mild steel plates, plain or chequered square cut or notched, ordinary and counter sunk, forming holes, without any attachment, complete all as specified and directed.
Surface excavation n.exc. 30 centimeter deep and averaging 15 centimeter deep and getting out in soft/ loose soil complete all as specified and directed.
M&L for hard core of broken stone or boulders of gauge n.exc 63 mm deposited spread and leveled in layers n.exc 15 cm thick watered and rammed to a true surface complete all as specified and as directed.
M&L for 100mm thick PCC type D-2 1:4:8 using 40 mm graded aggregate as in sub base of floor complete all as specified and directed.
S&F 80mm thick reflective rubber moulded interlocking precast PCC paver, tiles M-40 grade made up with 12.5mm graded mechanically crushed stone aggregate, factory made, of any tint, conforming to IS-15658-2006 over & including 25mm sand cushioning & filling the joints with coarse sand complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping, benching etc/surface channel drain with necessary form work complete all as specified and directed.
Dismantling plain or corrugated steel sheeting incl ridges any gauge/thickness nainital or similar pattern as in roof covering complete all as specified and directed.
Dismantling wrought iron or MS work of any description not otherwise provided for complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size straight or curved on plan exceeding 6 metre mean radius built in CM 1:6 complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:4 on ceiling finishing the surface even and smooth without extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and apply three coat of white wash complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110mm dia single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F 110 mm dia PVC (SWR) bends any radius complete all as specified and directed.
Cutting holes into or through brick walls built in cement mortar for inserting hold fast and making good in CM 1:3 including finishing to wall complete to match with the adjoining existing surface complete all as specified and directed.
M&L for PCC 1:2:4, type B-1, using 20 mm graded mechanically crushed stone aggregate as in fixing of hold fast coping etc and similar work including necessary form work complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings, fillets etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars etc conforming to Fe 290, grade E-165 complete all as directed.
Taking down carefully copper/aluminium point wiring light/fan/bell/socket or power complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surfaces of walls/floors/ceilings complete all as specified and directed.
M&L for one light/fan point controlled by one switch point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken modular type pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete all as specified and directed.
All as per item No. 32 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch.
All as per item No. 32 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch on same board.
All as per srl item No 32 above but for one call bell/buzzer point controlled by one bell push.
All as per srl item No. 32 above but for one light point controlled by (two Nos) two way switches.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken modular type pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 32 to 37 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed.
S&F modular switch single pole 2 way, 1 module, 6 Amp complete all as specified and directed.
S&F modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed.
S&F modular fan regulator 240 V electronic step type, 1 module complete all as specified and directed.
S&F modular Bell Push 6A SP 1 way, 1 module complete all as specified and directed.
M&L for point wiring for one light/fan point controlled by one switch with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia medium grade with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc with provision of new GI terminal boxes of not less than 1.60mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50 sqmm connected to common earth and earth dolly complete all as specified and directed.
All as per item No. 45 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch.
All as per item No. 45 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch on same board.
All as per srl item No 45 above but for one call bell/buzzer point controlled by one bell push.
All as per srl item No. 45 above but for one light point controlled by (two Nos) two way switches.
M&L for point wiring with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of GI terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3/6 pin 15 Amps socket outlet on independent board complete all as specified and directed. Note for item Nos 45 to 50 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F switch piano, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 5 amp, single pole, two way 240 volt complete all as specified and directed.
S&F bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 15 amp, single pole, one way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5 amps flush type complete all as specified and directed.
S&F socket outlet, two in one 3 pin, 5 & 15 amps flush type complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F Call bell ding dong , AC single pole 240 volts complete all as specified and directed.
S&F fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
M&L for replacement sub main wiring with 2 Nos single core PVC insulated unsheathed 6.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for replacement sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
S&F in replacement sheet metal enclosure (MCCB DBs) three phase and neutral with 200 Amps rated bus bar 4 way double door type complete all as specified and directed.
S&F in replacement sheet metal enclosure (MCB DBs) three phase and neutral with 200 Amps rated bus bar 4 way double door type complete all as specified and directed.
S&F in replacement sheet metal enclosure (MCB DBs) single phase and neutral with 200 Amps rated bus bar 12 way double door type complete all as specified and directed.
S&F in replacement sheet metal enclosure (MCB DBs) single phase and neutral with 200 Amps rated bus bar 8 way double door type complete all as specified and directed.
S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
S&F in replacement MCCB, 4 pole, 63/100 Amp 415 volts 16KA breaking capacity complete all as specified and directed .
S&F in replacement MCB TPN 63 Amp 415 volts 10KA breaking capacity 'C' curve complete all as specified and directed .
S&F in replacement MCB, SPN, 32 to 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F in replacement MCB, SP, 10 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
M&L for earthing complete as in replacement with galvanized steel earth plate 60cmx60cmx6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to earth lead GI 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade, including protection pipe GI medium grade 15mm bore for earthing lead, wire mesh, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1, precast RCC cover using XPM reinforcement weighing not less 4kg/sqm in lieu of CI cover and frame all as shown in electric plate of SSR part-I (2009), including testing on completion all as directed.
Taking down existing light fitting of any type, make & capacity complete all as specified and directed.
S&F 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No.LHEXBXPNIN1W020 or equivalent in Bajaj /CG.
S&F 9 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No.LHEXBXPNIN1W009 or equivalent in Bajaj /CG.
S&F recess mounting LED luminaire of size 2' x 2' white 36 watt, 230 volts for POP ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No. PLUTONEO2X2PLR or equivalent in Bajaj /CG.
S&F integral LED light fitting, 15 W, 230 Volts, decorative surface mounted round shaped (down lighter), complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- BAJAJ Model No. BGSLO SLEEK SURCFACE 15W WH RD or equivalent in Havells/CG.
S&F integral LED light fitting, 15 W, 230 Volts, decorative surface mounted round shaped (down lighter), complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- BAJAJ Model No. BGSLO SLEEK SURCFACE 15W WH SQ or equivalent in Havells/CG.
S&F integral building security LED light fittings with pressure dia cast aluminium of 15 watts and including and connecting up ceiling rose and fittings with 3 core, PVC insulated multistranded copper conductor cable of 1.5 Sqmm complete all as specified and directed. Make:- BAJAJ Model No. BRLEP 15W LED or equivalent in Havells/CG.
S&F in replacement LED lamps 9 watts complete all as specified and directed. Make:- Havells Cat part No. LHLDEUEEMC8R009 or equivalent in Bajaj /CG.
BEHL ENGINEERS AND TRADERS
M/s Deeksha construction
Saraswati Constructions
RVRconstructon
HARI OM CONSTRUCTION
M/S Satyam Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .