Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-Finance | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹31.4 L+₹1.3 L (4.16%)Accepted-Finance PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L2 | Accepted-Finance Not being lowest | |
| 3 | L3₹31.8 L+₹1.7 L (5.77%)Accepted-Finance | L3 | Accepted-Finance Not being lowest | |
| 4 | L4₹47.8 L+₹17.7 L (58.9%)Accepted-Finance | L4 | Accepted-Finance Not being lowest |
| Sl No | Description | Qty | Unit | M/s S.G. BUILDERS L3 | POONAM ENTERPRISES L4 | Lamba Enterprises L2 | yameen enterprises L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators, sockets, light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed. | 1,080 | Point | 25 ₹27,000 | 9 ₹9,720 Lowest | 10 ₹10,800 | 10 ₹10,800 |
| 2.00 | Taking down carefully sub main wiring of any description. | 4,242 | RM | 25 ₹1,06,050 | 3 ₹12,726 Lowest | 10 ₹42,420 | 3 ₹12,726 Lowest |
| 3.00 | Taking down defective switch fuse main board /MCCB Enclosure/ distribution iron clad or sheet metal enclosure/ MCB DBs with MCBs of any capacity and make including wooden board etc complete all as specified and directed. | 66 | Each | 25 ₹1,650 | 200 ₹13,200 | 10 ₹660 Lowest | 50 ₹3,300 |
| 4.00M & L for Point wiring (concealed) complete with 1.5 sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade with multi stranded copper conductor drawn through in and including non metallic medium grade rigid PVC conduit, ISI marked not less than 20 mm dia including all accessories concealed in wall by cutting chases and including provision of 1.5 sqmm PVC insulated copper cable FRLS unsheathed as earth continuty conductor including fabricated branded modular metal flush box duly make embossed, concealed in walls and with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified and as directed for the followings:- | |||||||
| 4.01 | One light /Ceiling fan/exhaust fan point controlled by one, one way switch . | 560 | Point | 425 ₹2,38,000 Lowest | 550 ₹3,08,000 | 459 ₹2,57,040 | 599 ₹3,35,440 |
| 4.02 | One bell point controlled by one bell push. | 20 | Point | 425 ₹8,500 Lowest | 550 ₹11,000 | 459 ₹9,180 | 599 ₹11,980 |
| 4.03 | One light point controlled by two Nos two way switches | 20 | Point | 425 ₹8,500 Lowest | 600 ₹12,000 | 450 ₹9,000 | 1,299 ₹25,980 |
| 4.04 | One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. | 200 | Point | 425 ₹85,000 Lowest | 650 ₹1,30,000 | 450 ₹90,000 | 599 ₹1,19,800 |
| 4.05 | One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board | 130 | Point | 255 ₹33,150 | 200 ₹26,000 | 400 ₹52,000 | 199 ₹25,870 Lowest |
| 5.00 | All as per item No.4 herein before but with 2.5 Sqmm cable for one 3 pin 15 Amp switch socket outlet and using 2.5 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed. Note for Item 4 & 5 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing&caping/Existing conduit to avoid any damage to the RCC portion.
(ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above.
(iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC. | 150 | Point | 855 ₹1,28,250 | 790 ₹1,18,500 | 650 ₹97,500 Lowest | 899 ₹1,34,850 |
Tender Value
₹48.1 L
EMD Value
₹96,160
Closing Date
29 Jun 2026, 6:00 pmClosed
LT COL MANISH E WASNIK
GE (CENTRAL) DELHI CANTT-10
8826/TOKEN-17/2026-27
2026_MES_769117_1
GE/TOKEN-17/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹96,160
Yes
7 Jul 2026
2 Jun 2026
1 Jul 2026
2 Jun 2026
29 Jun 2026
15 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators, sockets, light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed. | 1,080 | Point | - | - |
| 2 | Taking down carefully sub main wiring of any description. | 4,242 | RM | - | - |
| 3 | Taking down defective switch fuse main board /MCCB Enclosure/ distribution iron clad or sheet metal enclosure/ MCB DBs with MCBs of any capacity and make including wooden board etc complete all as specified and directed. | 66 | Each | - | - |
| 4M & L for Point wiring (concealed) complete with 1.5 sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade with multi stranded copper conductor drawn through in and including non metallic medium grade rigid PVC conduit, ISI marked not less than 20 mm dia including all accessories concealed in wall by cutting chases and including provision of 1.5 sqmm PVC insulated copper cable FRLS unsheathed as earth continuty conductor including fabricated branded modular metal flush box duly make embossed, concealed in walls and with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified and as directed for the followings:- | |||||
| 4.01 | One light /Ceiling fan/exhaust fan point controlled by one, one way switch . | 560 | Point | - | - |
| 4.02 | One bell point controlled by one bell push. | 20 | Point | - | - |
| 4.029999999999999 | One light point controlled by two Nos two way switches | 20 | Point | - | - |
| 4.039999999999999 | One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. | 200 | Point | - | - |
| 4.049999999999999 | One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board | 130 | Point | - | - |
| 5 | All as per item No.4 herein before but with 2.5 Sqmm cable for one 3 pin 15 Amp switch socket outlet and using 2.5 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed. Note for Item 4 & 5 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing&caping/Existing conduit to avoid any damage to the RCC portion.
(ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above.
(iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC. | 150 | Point | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_861320.xls
BOQ • 0.33 MB
tenderpage.pdf
Tender Documents • 0.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .