Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.2 L+₹27,197 (0.78%)Rejected-Finance OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | L2 | Rejected-Finance L2 | |
| 3 | L3₹35.2 L+₹33,552 (0.96%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹36.4 L+₹1.5 L (4.27%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹37.2 L+₹2.3 L (6.46%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
SPL REAPIR/REPLACEMENT OF SERVICE CABLES AND UG CABLES ALLONGWITH CONNECTED ALLIED WORKS IN VARIOUS MD ACCN AND PROVN OF DYNA ROOF TO BLDG NO T-2, SINGLE OFFICERS ACCN AND INCLUDING CERTAIN REVENUE WORKS AT DINJAN UNDER GE DINJAN
2020_MES_381045_1
C/8235/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹80,000
Yes
26 Nov 2020
25 Sept 2020
26 Oct 2020
25 Sept 2020
23 Oct 2020
10 Oct 2020
60 days
Amount
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches n.exc 1.5 m wide and not.exceeding 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading in layers not exceeding 25cm levelling, watering and well ramming in soft/loose soil complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering and removing surplus soil to a distance not exceeding 50m and making good surface in soft/loose soil complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of post holes filling and mass concrete, etc complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in benching, coping, lintel upto 1.5m span cast in situ including necessary form work complete all as specified and as directed.
M&L for Brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exceeding 6 m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortor (1:4) complete all as specified and as directed.
M&L for Hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floors laid in panels and finishing the surfaces even and smooth with using extra cement complete all as specified and as directed.
M&L for 75 mm thick plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection, hardstanding, etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and as directed.
M&L for 40 mm thick, plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floors and finishing the surfaces even and smooth with using extra cement complete all as specified and as directed.
Forming Construction joints 30mm deepx10mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed.
Forming 12 mm thick expansion joints for 100 mm thick concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and as directed.
M&L for making joints with bitumastic filing in proportion of bitumen and sand (1:2) making impressions of expanded metal whilst the concrete is green complete all as specified and as directed.
M&L for Chequered cement concrete tiles of size 25cm x 25cm x 22mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
Dismantling of asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings with ridges complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F for rolled mild steel work as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
S&F for mild steel steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and as directed.
S&F for mild steel screw bolts of 11 to 15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 15cm and n exc 22.5cm long complete all as specified and as directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. Note : Colour of ridge shall be same colour as that of sheet used for roof.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
M&L for 1.6 mm thick mild steel plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and as directed.
S&F for TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets complete all as specified and as directed.
S&F for aluminium anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of white wash complete all as specified and as directed. Make of E-Board : Eternit Everest/lafarge/Armstrong or equivalent make as approved by GE
M&L for preparing newly surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
Taking out/down old/unserviceable under ground LT cables of any size and connections including pipes etc from trenches/walls/poles of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 6 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 4 core, nominal cross sectional area of main conductor 25 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 35 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 50 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 70 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 95 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed.
Re-laying jointing, commissioning and testing serviceable LT UG cable of any size any core as retrieved from item No. 38 above complete all as specified and as directed.
M&L for sand cushioning and covering with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and as directed. Note : Thickness after punning down shall be measured for payment.
Supply and laying well burnt bricks, sub class 'B' bricks laid breath wise across length of cable in trenches for protection of UG cables complete all as specified and as directed.
M&L for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc. as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
M&L for 80 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/ road crossing/drain etc. as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
M&L for 100 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/ road crossing/drain etc. as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 11000 Volts (Earthed) cable of size 6 Sqmm to 16 Sqmm 2/3.5/4 core complete all as specified and as directed.
Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 11000 Volts (Earthed) cable of size 25 Sqmm to 50 Sqmm 2/3.5/4 core complete all as specified and as directed.
Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 11000 Volts (Earthed) cable of size 70 Sqmm to 120 Sqmm 2/3.5/4 core complete all as specified and as directed.
S&F in repairs factory made busbar chamber system, fabricated by using sheet steel (CRCA) and epoxy powder coated, wall/post mounted, 4 way and suitable for current rating 100 Amps with all necessary fittings complete all as specified and as directed. Make : Cat No. IHBB010004 of Havells/L&T/Bajaj.
Boring of holes horizontall for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under road pavement, hardstanding using trenchless technology complete all as specified and as directed. Note : Cost of accessories required for making hole/bore deemed to be included in the quoted rate.
M/s Dhani Enterprise
Vicky Construction
M/S AUTOMOTIVE WORLD
M/S Karen Enterprises
M/S CHANDAN ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .