Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC 00 ITBAHRA GAUR KANIKAPUR ROAD KANIKAPUR BASTI UTTAR PRADESH 272163 | BASTI | UTTAR PRADESH | 272163 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.8 L+₹3.4 L (12.4%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L2 | Rejected-Finance Quoted other than lowest rate. | |
| 3 | L3₹30.9 L+₹3.4 L (12.5%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate. | |
| 4 | L4₹32.3 L+₹4.8 L (17.6%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Quoted other than lowest rate. | |
| 5 | L5₹32.8 L+₹5.4 L (19.6%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate. |
Tender Value
₹49.9 L
EMD Value
₹1 L
Closing Date
24 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA PIN-151004 C/o 56 APO
SPL REPAIR TO BLDG No. P-136 OF PIRU SINGH ENCLAVE AND BLDG No. T-955 OF OTM ACCN OF MED REGT AND PROVN OF 01 SEPTIC TANK AND 01 SOAKAGE WELL UNDER AGE BR-III, AGE BR-V AND AGE E/M OF GE NORTH BATHINDA AT BATHINDA MIL STN
2022_MES_566057_1
8937/NIT-65/22-23
Open Tender
Civil Works
Item Rate
180 days
GE NORTH BATHINDA
Class D category a(i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹1 L
Yes
17 Jan 2023
29 Nov 2022
26 Dec 2022
29 Nov 2022
24 Dec 2022
12 Dec 2022
29 Nov 2022 - 5 Dec 2022
Amount
SCHEDULE 'A' B/R Works
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames, wooden/PVC doors/steel ventilator) area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Taking down shutters only of any description area not exceeding 1.0 sqm each and removing from site complete all as specified and as directed by Engineer-in- charge.
Taking down shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each and removing from site complete all as specified and as directed by Engineer-in- charge.
Resecuring, easing and adjustments of shutters (any description and any size of shutter upto 4 Sqm each) without taking down from chowkhat/frame including oiling, tigtening of screws, minor repairs, adjustment of hinges, adjustment of fittings like handle/tower bolt/door stopper etc complete all as specified and as directed by Engineer-in- charge. Note :- Screws if required for adjustment of fittings the cost of screws shall be included in the unit rate.
Supply and fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 150mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing 100mm long powder coated mild steel butt hinges medium weight cold rolled complete all as specified & directed by Engineer-in-charge.
Supply and fixing anodised aluminium handle fabricated type 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing factory made 105 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing factory made 125 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ.
Material and labour for PCC (1:2:4) type B-0, using 12.5 mm graded aggregated as in back filling of chowkhats and for hold fast, etc. complete all as specified and as directed by Engineer-in-Charge.
Material and labour for mild steel framed work/Framed brackets MS angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, rails, braces, riveting, nut bolts etc., complete conforming to Fe 410-0 or 310-0 (Gde-E- 250) quality-A complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for cutting holes in brick walls in cement mortar for inserting holdfast and making good dismantled portion in cement mortar 1:3 or cement mortar 1:2:4 type B-1 using not exc. half brick walls depth of embedded portion of holdfast or lugs measured from the face of the jamb into walls, complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing factory made plain framed panelled shutters (two panels as approved), 35mm thick of 2nd class hard wood with lock rail and panel inserts of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhat complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply & fixing factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated (two panels as approved) and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8 and fitted to chowkhats, menbers shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item of BOQ.
Supply & fixing flush shutter 35mm thick, solid core construction with block board core and plywood face panels, commercial type on both sides including adhesive for pasting and screws for fixing to timber frame complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 18-20mm thick Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws/nails/fevicol to timber frame work as in cupboard shutter, shelves etc. including cutting and made to shape as required complete all as specified & directed by Engineer-in- charge.
Supply & fixing Continuous (piano) hinges, mild steel, bright finish or electro galvanised, width of flap when open 30mm complete all as specified and as directed by Engineer-in-charge .
Supply and fixing cupboard knob 40mm dia fixed with nut, screw and washer complete all as specified and as directed by Engineer-in-charge .
Supply & fixing 100mm long aluminum anodised hasp & staple, safety type, with mild steel hinge pin including bolt to hinge plate fixed with and including screws complete all as specified and directed by Engineer-in-charge.
Supply & fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tack or stainless steel wire staples complete all as specified & directed by Engineer-in- charge
Supply & fixing in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tack or stainless steel wire staples complete all as specified & directed by Engineer-in- charge
Supply & fixing galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel barrel tower bolt stove enamelled black with bright bolt 200 mm long, fixed complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel sliding door bolts 300mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts washers, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in- charge.
Supply & fixing aluminium anodised sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel pressed handle of size 150mm, oval type, stove enameled black complete all as specified & directed by Engineer-in- charge.
Supply & fixing 140mm long (overall length of cover plate ) Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, including sitable screws for fixing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing mild steel 300mm long rat tail rod pattern spring including roller and roller plate and fixing to wooden frame with screw complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair mild steel 300mm long rat tail rod pattern spring including roller and roller plate and fixing to wooden frame with screw complete all as specified and as directed by Engineer-in- charge.
Supply & fixing factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, without glazing bars (mosquito proof shutter) including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, suitable steel handle, steel peg stay, fixing lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Material and labour for mild steel work conforming to Fe-290 (Gde E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, walkways, railing, framed work of water tanks and similar works, complete all as specified and as directed by Engineer-in- charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips, oil putty complete all as specified & directed by Engineer-in- charge.
Supply & fixing and cutting as per size requirement 4mm thick sheet glass ordinary quality in squares/retangular not exceeding 0.5sqm in each pane and fixed in any type of doors / windows / ventilators (openable/fixed type) with fixing material complete all as specified & directed by Engineer-in- charge.
Supply & fixing and cutting as per size requirement 3mm thick sheet glass ordinary quality in squares/retangular not exceeding 0.5sqm in each pane and fixed in any type of doors / windows / ventilators (openable/fixed type) with fixing material complete all as specified & directed by Engineer-in- charge.
Supply & fixing, 4mm thick frosted eatched (one side) in squares/retangular not exceeding 0.5sqm in each pane and fixed in any type of doors/windows/ventilators with fixing material complete all as specified & directed by Engineer-in- charge.
Supply and fixing in replacement stainless steel chromium plated pipe 25mm dia, wall thickness of pipe not less than 20 guage, as curtain rod fixing with and including fancy type brackets and decorated end knobs (finials), stop roller etc, fixed on wall for doors and windows curtains, cuttings as required length and fixing at site including fixing arrangements, rawl plug, screws etc. including taking out old any type rod or pelmet boxes with curtain rod complete all as specified & directed by Engineer-in- charge.
Supply & fixing stainless steel sink made out of 1.00mm thick sheet, overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm, kitchen or laboratory with plugs, washers, waste pipe including bedding in cement mortar, fixing in existing space or fixing with cast iron cantilever brackets and connecting union to waste pipe, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for plate rack stainless steel of size 0.90 metre x 0.90 metre made out of 1mm thick MS sheet with all necessary fittings, screws, bolts and sufficient space for utenciles, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Mild steel, 1.60mm thick plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in first floor, ground floor, sunken portion and paving at any thickness below or above floor level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for sunken treatment to floors with 10mm thick cement plaster in Cement mortar 1:3 even and smooth without using extra cement mixed with water proofing compound @ 200 ml per bag of cement at bottom/sides of slab, complete all as specified and as directed by Engineer-in-Charge
Material and labour for applying one coats of Dr. fixit pidecrte in sunken floor portion of toilets and bathrooms, chajja stair case etc. by using of 1 to 2 Sqm and applying by brush etc., complete all as specified and as directed by Engineer-in-Charge
Material & Labour for PCC (1:5:10) type E2 using 40mm graded stone aggregate as mass filling, filling as in sunken floors complete all as specified and as directed by Engineer-in-charge.
Material and labour for 30mm thick cement concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in floor, sunken floor etc, finished rough to receive tiles, including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, complete all as specified and as directed by the Engineer-in-Charge. (Note :- WPC shall be measured & paid separately as Supply only)
Dismantling brick/PCC terracing tiles single layer in roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge.
Demolition of mud in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part there of) including removing/cutting uprooting grass, vegetations and roots of small plants etc on roof floor and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for cleaning surface of roof, including flashing and junction of parapets etc. by wire brushing, removing all dust and washing with water and preparing to receive rendering, after preparing that applying 15mm thick screed /rendering in cement mortar (1:3) including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg on existing concrete surfaces of roof and finished even and smooth without using extra cement, complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per Sqm, including cleaning surface, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 150 micron thick polythene sheet laid on a coat of bitumen primer @ 0.3 Kg to 0.5 Kg per Sqm, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 80mm thick (average) consolidated thickness mud phuska on flat roofs including 25mm thick mud plaster and 3mm thick leeping plaster, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 40mm thick brick tiles laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ 200ml per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for 40mm thick brick tiles (old serviceable tiles obtained from demolition/dismantled item shall be reused) laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ 200ml per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for flush pointing to brick tiles laid flat in cement mortar (1:4) including racking out joint & pointing to brick tiles, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for PCC (1:2:4) Type B0 using 12.5mm graded stone aggregate as in roof kerb (golla) or mud stops, coping, side of roof sheet & similar work etc rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Taking up or down existing galvanised steel water tubing (GI pipe)/any other type of pipe 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe)/any other type of pipe 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe)/any other type of pipe 25mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 25mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as required) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Material and labour for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc. and for concealed conduit wiring, water tubing etc., and making good cutting exc. 10 cm but not exc. 20 cm girth for brick wall, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and including dismantling/taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as under appropriate item of BOQ.)
Supply and fixing in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply & fixing in repair, stop valve/angle valve cast copper alloy, with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 20mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing 40mm dia low density polythylene pipes (LDPE) of pressure rating 6 Kgf/Sqcm fixed, complete all as specified & directed by Engineer-in-charge.
Supply & fixing in repairs vitreous china semi pedestal pattern (anglo indian type), size 580mm x 440mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti syphonage pipe, etc., complete all as specified & directed by Engineer-in-charge.
Supply & fixing in repair vitreous China squatting pan 'Orissa' pattern white of size 580mmx440mm with integral foot rests (excluding flushing cistern, flush pipe above floor and trap), including demolation of tile, PCC, taking out old WC, taking out lime concrete filling and after fixing new WC re filling lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, including fixing PVC flush pipe upto finished floor level, joints of flush pipe and trap make leakproof and testing before filling concrete and including all other connected work as required upto entire satisfaction of Engineer-in-charge complete all as specified and as directed by Engineer-in- charge. (NOTE : Tile work with screed shall be measured and paid separately under appropriate item of this schedule.
Supply & fixing in repair vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair plastic water closet seat with cover (white colour) closed pattern with flat bottom/recessed bottom and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair stainless steel chromium plated jet suitable for EWC, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair vitreous china wash basin, white, flat back of size 550mm x 400mm, including 32mm chromium plated waste coupling and PVC waste pipe including bracket and cutting for and pinning in end of bracket or erecting complete all as specified and as directed by Engineer-in-Charge. (Note :- Pillar tap if required in replacement, shall be measured & paid separately under appropriate item of BOQ.)
Supply & fixing in repair 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair, 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply & fixing in repair, stop valve/angle valve cast copper alloy, with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing in repair, soap dish holder, fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in repair, cromium plated shower rose 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in repair, concealed stop cock cast copper alloy, chromium plated, fancy type, long shank and cup, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock shall be as given in SSR or in relevant IS.
Supply & fixing in repair, bib tap cast copper alloy, chromium plated with crutch or butterfly handle with capstan head, wall flange,fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing in repair, brass chromium plated tubular towel rail 20mm dia 'D' type, 600mm long between flanges fixed to plug , bracket with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for brass CP mixer of any type (wall mixer/WHB mixer) for mixing hot & cold water screwed down for iron pipe bore 15mm and fixed, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair Cast iron floor trap 75mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair Cast iron floor trap 100mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in repair 100mm size CI gully traps, square or round mouthed, type 'P', complete all as specified and as directed by Engineer-in- charge.
Dismantling cast iron drain pipes, jointed in cement mortar of any description any dia from wall and taking out from trenches including all fittings (bend, trap, cowl, branch piece etc) and removing from the site complete all as directed by Engr-in-Charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor/fixed to walls, jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor/fixed to walls, jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair 100 mm cast iron sanitary connection socket to fit out let of WC complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 100mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch fitted with oval access door as specified & directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron cowl complete all as specified and as directed by Engineer-in- charge.
Supply & fixing stack clamps for 100mm dia pipe made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (interval of 1m) including nut bolt and PCC work, including dismantling/taking down old pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for rendering/plastering 10mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 10mm thick in cement mortar (1:3) over 10mm thick additional setting/ floating coat in cement mortar (1:4) on concrete surfraces of wall, chajjas, parapet, beams and ceiling etc., finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for preparing newly plastered or concrete surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for one coats of white washing on ceiling of old surfaces including complete removal of existing treatment, complete all as specified and as directed by Engineer-in-Charge
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other means, and preparing the surfaces smooth by applying white cement based putty to make the surface even and smooth by using sander machine (with provision of dust sucking) upto entire satisfaction of Engineer-in-charge, and after preparing the surfaces applying two coats of oil emulsion distemper (washable), as approved tint/colour by using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of wall/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down and preparing the surfaces smooth and after that applying one coat of white cement based putty (wall care putty, make Birla JK or equvilent as approved by Engineer-in-charge), after applying putty first and second coat sanding the surface as per requirement by using mechanical sander machine to make the surface even and smooth upto entire satisfaction of Engineer-in-charge and after prepare the surface smooth applying two coats of oil bound distemper (washable) as per approved tint/colour by using paint brush or roller brush complete all as specified and as directed by Engineer-in-Charge. NOTE : - Each stage i.e after complete removal and before applying OBD as specified above, the surface shall be passed in writing by the Enigineer-in-charge.
Material and labour for preparation of newly plastered surfaces of walls and applying three coats of acrylic smooth exterior emulsion paint (one coat as a priming coat), complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment on old plastered and unplastered surface and applying two coat of acrylic smooth exterior emulsion paint on old plastered surfaces of walls, including preparing surface, complete all as specified and as directed by Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Roughening surfaces of old concrete floor by picking and prepare the surface to receive the screed for tiling/kota stone, sweeping cleaning and washing down with water to remove dust etc. complete all as specified and as directed by Engineer-in-Charge.
Dismantling of bricks, PCC tiles, interlocking tiles laid flat of any description or thickness in floors, aprons etc. laid dry or laid dry and pointed in any mortar including removing rubbish material from the site including taking out existing fine sand cleaning the surface complete all as specified and as directed by Engineer-in-charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8mm thick square or rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8mm thick square or rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick bedding layer (screed) in cement mortar (1:4) including making good excess taking down plaster area (above skirting tile ) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm// 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for machine cut 18 to 22 mm thick, Kota stone slab (size of slab not less than 550x550mm) as in flooring, laid over and including 15 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish) and polishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for machine cut 18 to 22mm thick, Kota stone slab as in riser of steps, skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish ) and polishing by machine, including machine cutting to make it square or rectangular complete all as specified and as directed by Engineer-in-Charge.
Material and labour 18-20mm thick machine cut, marble work other than black and white marble (table rubbed and polished) of approved colour for counter sunk wash basin, plateform/cooking plateform or as directed, including screed bed 15mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement (1:2) using marble dust with admiture of pigment to match with shade of granite stone slab including cutting as required including cleaning and extra polishing if required, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for moulding the edges half round on exposed side (Rounding to edges of stone slabs one edge) of granite/marble as in kitchen shelf, cooking platform, WHB counter shelf, steps, and other similar situations etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Material and labour for Preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement including demolition of cement concrete (unreinforced, existing plinth floor, hard standing etc ) of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Demolition of cement concrete reinforced of any discription and in any position not otherwise specifically provided (like kitchen shelf, WHB counter shelf, slabs and similar suspended works), including cutting of steel as directed and prepare the surface to casting new shelf/slabs and removing rubbish materials from site and deposited as directed complete all as specified and as directed by Engineer-in-charge
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in chajjas, beams, staircases, landing, fins, facia and similar suspended works complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 6 mm to 8mm dia cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Form work to chullah hoods, chajjas, trough and similar items including edges rough finished flat surfaces complete all as specified & directed by Engineer-in- charge.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Demolition and breaking up drain pipes SGSW, AC or reinforced concrete pipe up to and including 150 mm bore pipes complete all as specified and directed by Engineer-in-Charge.
Material and labour for cement concrete (1:3:6), type C2 using 40mm graded stone aggregate as in bed of drain pipe of size 150mm bore (internal) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
Material and labour for 150mm bore (internal dia) salt glazed stone ware (SGSW) drain pipe, grade ‘A’, laid on concrete bed to required slope in trenches, jointing with packed spun yarn and in cement and sand mortar (1:1) and tested complete all as specified and directed by Engineer-in-Charge. (Note : Excavation, earrh work and concrete bed shall be measured and paid separately under appropriate item of BOQ.)
Material and labour cutting into existing manholes/septic tank for connecting new drain upto 150mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round to 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required complete all as specified & directed by Engineer-in-charge.
Supply and fixing 60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC paver mould / Rubber paver moulds on Vibrating Table Machine) using grey cement and no pigment, shape haxagon / trigular / zigzag / I-shaped etc, as directed, prepolished & preglazed, specification as per relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over sand upto required thick layer and filling the interstices etc complete all as specified and as directed by the Engineer-in-Charge. Note : - (i) Sand for filling shall be measured & paid separately as Supply only but labour for spreding leveling shall be included in the unit rate of this item)
Material and labour for 100mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and as directed by Engineer-in-charge.
Supply only fine sand without silt (Fazilka/Zera or any other approved sources) for filling under interlocking tiles and the interstices etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in coping/packing around chequered tiles/interlocking tiles/kerb stone & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for welding in repairs not exc. 2.5 cm in length and not exc. 6mm in thickness, complete all as specified and as directed by Engineer-in-charge.
Material and labour for welding in repairs in running welding thickness of metal to be welded not exceed 6mm, complete all as specified and as directed by Engineer-in-charge.
Dismantling Plain or corrugated/semi corrugated AC sheeting, any gauge, thickness, as in roof coverings, complete all as specified and as directed by Engineer-in-charge.
Dismantling timber scantling 40 Sqcm and over in section, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick, any colour having tensile strength of 550 Mpa as in ridge (including cutting and bent to shape), roof covering, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Material and labour for mild steel framed work, framed/truss work made by using hollow square/rectangular/round pipe (ERW or induction butt welded tubes conforming to latest relevant IS), or other section like angle, tee, plate, distance pieces, cleats etc. and cut to shape, drilled and counter sunk for screw, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and fixed with angle cleats or other connecting plates, gusset plates, brackets, bending and welding, riveting etc, conforming to Gde Fe-410-W (Gde E-250 quality A) complete all as specified and as directed by the Engineer-in-Charge. Note ;- Sketch of truss design and steel section to be used shall be approved by Engineer-in-charge in writing before execution)
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets fixed in any position with nails fixed with screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing anodised aluminium snap grid frame work of size of grid 605 x605mm for false ceiling including necessary notching and prepared holes, the snap grid shall consist of anodised aluminium main tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM, cross and Intermediate tee of size 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM. The main and cross tee shall be jointed at junction with steel screws or MS bolts, nuts and washers, the snap grid (main / cross tee sections) shall be supported at ends all along the wall with anodised aluminium angle of size 35mm x25mmx 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and duly suspended with 4mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 12mm thick gypsum board in grid fixed in false ceiling grid made of aluminium as per above specifications complete all as specified and as directed by Engineer-in-charge.
Material and labour for providing precast cement concrete set in cement mortar 1:4 type B-1 1:2:4 (20mm graded aggregate) in window or door cills, lintels bressumers, steps quoin blocks for use with masonary including necessary form work, complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Excavation over areas, not exceeding 1.5mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 1.5mtr and not exceeding 3mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 3mtr and not exceeding 4.5mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 4.5mtr and not exceeding 6mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for hard core of broken bricks of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Material and labour for PCC (1:3:6), type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, bed block, for embedded fencing posts & similar work etc including form work complete all as specified and as directed by Engineer-in-charge.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Form work to soffits of suspended slabs such as flat roof slabs, floor slabs, shelf slab, landings and similar work not exceeding 200mm thick (horizontal or sloping) rough finished complete all as specified and as directed by Engineer-in- charge.
Supply and fixing mild steel 16mm round bars as in rungs in soak pits, complete all as specified and as directed by Engineer-in- charge.
SCHEDULE 'A' ELECTRIFICATION WORKS
Taking down carefully copper/aluminum point wiring (light, fan, socket or power point) complete including fittings such as hylum sheet, switches, ceiling rose, pendent holder, sockets, regulator, etc but except concealed conduit, sunken boxes and junction box etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing concealed PVC rigid conduit and existing sunken box, including 3mm thick bakelite plastic laminated sheet for mounting of switches and socket, fan regulator, for light /fan/bell point, controlled by one switch, including brass screws & cup washers and covering with and including frame, including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per item No 171 here in before but for socket outlet 3/5 pin 5/6 Amp 250 Volts on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 171 here in before but for socket outlet 3/5 pin 5/6 Amp 250 Volts on independent board but not below the switch board, complete all as specified and as directed by Engineer-in-Charge.
All as per srl items No. 171 here-in-before but for 3/5 pin 15 Amp socket out let by using 2.5 sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent board including provn of 2.5 sqmm unshearhed, multi stranded copper conductor cable FR-LSH continues as earth wire connecting to earth dolly etc. complete all as specified and directed by Engineer-in-Charge.
Material & Labour for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC concealed conduit not less than 20mm dia (medium duty ISI marked) and conduit fittings with and including 3mm thick bakelite laminated sheet top cover for one fan/light controlled buy one switch including provision of 1.5 Sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable earth wire to common earth & connecting to earth dolly all as specified and directed.
All as per item No 175 here in before but for socket outlet 3/5 pin 5/6 Amp 250 Volts on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 175 here in before but for socket outlet 3/5 pin 5/6 Amp 250 Volts on independent board but not below the switch board, complete all as specified and as directed by Engineer-in-Charge.
All as per srl items No. 175 here-in-before but for 3/5 pin 15 Amp socket out let by using 2.5 sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent board including provn of 2.5 sqmm unshearhed, multi stranded copper conductor cable FR-LSH continues as earth wire connecting to earth dolly etc. complete all as specified and directed by Engineer-in-Charge.
All as per item No 175 here in before but for one socket outlet bell point, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 175 here in before but for one light point controlled by two two way switch, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush type, single pole, one way, 5/6 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush type, single pole, two way, 5/6 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush type , single pole, one way, 15/16 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing bell push 6 Amps 230 Volts AC ISI marked, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing electric bell, ding dong type 230 Volts AC supply, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Socket outlet multipurpose, 2 in 1, 5 pin, 5/6 Amps, flush type, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Socket outlet multipurpose , 2 in 1, 5 pin, 15/16 Amps, flush type, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing stepped type (1-4), electronic Fan regulator (two module), 100 watt, 250 volts, fixed on laminated sheet suitable for ceiling fan, complete all as specified by Engineer-in-charge.
Supply and fixing ceiling rose surface type polycarbonate, isolated body two to three terinal,, tpline series 20 x 50mm, 6 Amps, three terminal, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder PVC/Polycarbonate cased body of brass with back plate suitable for batten fittings complete including 9w LED bulb, complete all as specified and as directed by Engineer-in-Charge. Make of holder : Anchor/Havells/Legrand/Indoasian/SSK and Make of LED bulb :- Crompton/Philips/Bajaj/Havells
Supply and fixing in replacement MCB SP suitable for 240 volts AC supply 6 to 40 Amps, SP rupturing capacity not less than 10KA, C Curve ISI Marked, 1 Module, including taking down unserviceable old MCB, complete all as specified and as directed by Engineer-in-Charge. Make:- Legrand/Schenider/L&T
Supply and fixing MCB SPN 40-63 Amps, 10 KA 'C' curve 240 V AC, 50 Hz including necessary attachment, including taking down unserviceable old MCB, complete all as specified and directed by Engineer-in-Charge. Make:- Legrand/Schenider/L&T
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) TPN, 4 Way 415V concealed in wall or as directed), double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof suitable for incorporation of MCCB's upto 125 Amp and isolators etc., and including making good disturbed surfaces of walls as necessaty, including taking down old unserviceable DB, complete all as specified and directed by Engineer-in-charge. Make:- Legrand/Schenider/L&T
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 12 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc., and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Make:- Legrand/Schenider/L&T
Supply and fixing in replacement of MCCB of capacity 125 Amp, FP, 415 volt, short circuit breaking capacity not less than 16KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc , MCCB fixing in new DB or the existing DB/Panel including making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge . Note :- DB shall be measured and paid separately under appropriate item of BOQ. Make:- Legrand/Schenider/L&T
Material and labour for sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, taking out old sub main wiring of any conductor any size from conduit and taking down old unserviceable conduit with fittings and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour for sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, taking out old sub main wiring of any conductor any size from conduit and taking down old unserviceable conduit with fittings and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour for Sub main wiring complete with two single core 6 sqmm,1100 volts grade, PVC insulated, multi -stranded copper conductor cable FRLSH with continuous copper earth conductor of 6 sqmm in existing PVC concealed conduit including taking down old unserviceable submain wiring, complete all as specified and directed by Engineer-in-charge. Make : Anchor/havells/Dcab.
Supply and fixing in replacement of new generation energy saving & environmental friendly long life versatile Pressue die cast aluminium housing, heat resistant glass, energy saving, IP-66 protection, better optics for uniform distribution street/Roadway luminaire with high power LED 20 Watt compete fitting with driver, LED strip and all other accessories etc. suitable GI bracket and making electric connection with using twin core copper cable of suitable size including taking down old unserviceable light fitting any type, complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing wall mounted LED fitting 1 x 20 Watt, 6000 k, 4 ft complete with retro LED tube and batten, environment friendly, energy efficient complete with all fittings connections, complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing wall mounted /surface mounted decorative wall light fixture in cylindrical profile made up of polycarbonate for and including LED 7 Watt lamp, base B22, complete fitting with LED lamp and all other fixing accessories including electric connection connecting with using flexible copper wire twin core including taking down old unserviceable light fittings any type, complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Taking down old and unserviceable, distribution board ant type including, MCBs etc. after removing all connection and make good the disturbed surface, complete all as specified and as directed by Engineer-in-Charge.
Supply and hanging /fixing in replacement of ceiling fan 1200 mm sweep in white/off white colour, 50watt, copper winding, 3 Blade, single phase, 230 volts 50 Hz double ball bearing, energy saver/energy-efficient, alongwith hanging rod (length as per site requirement or as directed by Engineer-in-charge), canopy (lower and upper), rubber real, nut bolts, lock pin etc. including making electrical connection with flexible round twin core multi strand copper cable suitable size complete all as specified and as directed by Engineer-in-Charge. Make and cat part :- Entrust 50 of Crompton / Energia of USHA / ES 50 of Havelles / Electra 50 of Bajaj Note :- (i) Srl Number of ceiling fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Ceiling fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account (iii) Old rusted and outdated ceiling fans deposited to MES store cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account
Supply and fixing in replacement energy efficient LED street light fitting of 25/35 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP 66 degree of protection, PF>0.95 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 5 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including 25 watt LED lamp with GI brackrt-01 No, MS clamp-02 Nos suitable for walls/ columns and making electrical connection with providing of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as specified, complete all as specified and as directed by Engineer-in-charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing LED mirror light fiting 9/10 watt, 6000K, lineer & compact with decorative grey end caps, polycarbonate body and ribbrd opal diffuser complete fitting with lamp and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing exhaust fan 300 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Make - Usha / Bajaj / Khaitan / Orient / Crompton / Polar Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Exhaust fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and fixing in provision of storage type water heater (Geyser) electrical operated 230/240 Volts 25 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, plug top, etc. required for proper functionality & including electric/earth connections and carrying out grounting & complete installations with mounting bolts,nuts including testing after installation complete all as specified and directed by Engineer-in-Charge.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC/geyser Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 25 Amps, 240 volts, AC supply, complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing and testing XLPE LT Cable of size 35 Sqmm, 3.5 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I), laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling, including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing/laying GI tubing, light grade, 40 mm bore for protection of cable or earthing lead wire under hardstanding/fixed along poles/wall, laid in in trenches etc., including taking down old unserviceable tubing complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing & commisioning of wall mounted indoor LT panel board protection class IP65, 415-433V made out of 2.0 mm thick RAL 7032/7035 coated CRCA steel, dust and vermin proof, double door complete prewired, with locking arrangements and hanging bracket suitable for fixing on wall, including painting with powder coated paint over a coat of redoxide zinc crome primer complete including necessary internal wiring and suitable size following electric safety equipments inserted in this panel comprising of the following:- (a) Way for Incomer 100 A 4 pole MCCB -01 No (b) Provision of Ampere meter suitable for 0-200 Amps (c) Way for outgoing MCCB 63 A 4 pole -02 Nos (d) way for 63 A MCB C Curve-06 No (e) way for MCB 10 Amps -01 Nos (f) R Y B phase Indicating lamps - 01 Set (set of three) (g ) insulated Copper Busbars 200A rating - 04 Nos (h) Provision of digital Voltmeter suitable for 0-500 Volts AC (j) Provisional arrangement way for energy meters with transparent acrylic sheet with separate locking arrangements -04 Nos
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I), including dismantling of old unserviceable earthing, complete all as specified and and as directed by Engineer-in-charge.
Ajay Enterprises
K L JINDAL AND CO.
SHARDA ENTERPRIES
RAKESH KUMAR GARG & CO.
V K CONTRACTOR
M/s Balvinder Singh Engineer and Contractors
G N CONSTRUCTIONS
M/s MITTAL CONSTRUCTIONS
R K GOYAL & COMPANY
M/S VIAJY BUILDERS & DEVELOPERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .