Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹11.5 L+₹1.5 L (14.9%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹11.9 L+₹1.9 L (19.0%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹12.5 L+₹2.5 L (24.8%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | DEO Traders L1 | YS CONSTRUCTION L4 | santosh electronics L3 | SUSHMANAND ENGINEERING WORKS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified. | 207 | Point | 20 ₹4,140 | 10 ₹2,070 Lowest | 25 ₹5,175 | 20 ₹4,140 |
| 2.00 | Point wiring in replacement of one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified. | 62 | Point | 300 ₹18,600 Lowest | 350 ₹21,700 | 455 ₹28,210 | 375 ₹23,250 |
| 3.00 | All as per srl item No 2.00 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controleed by one switch. | 14 | Point | 200 ₹2,800 Lowest | 450 ₹6,300 | 550 ₹7,700 | 500 ₹7,000 |
| 4.00 | All as per srl item No 2.00 here in above but for one 3 pin 5 Amps socket outlet independent with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controleed by one switch. | 12 | Point | 200 ₹2,400 Lowest | 350 ₹4,200 | 458 ₹5,496 | 375 ₹4,500 |
| 5.00 | All as per srl item No 2.00 here in above but for one 5A socket outlet on the same board with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controlled by one switch. | 10 | Point | 300 ₹3,000 | 100 ₹1,000 | 200 ₹2,000 | 80 ₹800 Lowest |
| 6.00 | Point wiring in replacement of one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified. | 31 | Point | 300 ₹9,300 Lowest | 375 ₹11,625 | 458 ₹14,198 | 400 ₹12,400 |
| 7.00 | All as per srl item No 6.00 here in above but for one socket outlet 5 amps on indipendent board with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controlled by one switch with including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed. | 6 | Point | 300 ₹1,800 Lowest | 350 ₹2,100 | 485 ₹2,910 | 400 ₹2,400 |
| 8.00 | All as per srl item No 6.00 here in above but for one socket outlet 5 amps on same board with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controlled by one switch including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed. | 7 | Point | 300 ₹2,100 | 100 ₹700 Lowest | 200 ₹1,400 | 100 ₹700 Lowest |
| 9.00 | All as per srl item No 6.00 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed. | 9 | Point | 300 ₹2,700 Lowest | 450 ₹4,050 | 590 ₹5,310 | 550 ₹4,950 |
| 10.00 | Point wiring in replacement of one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in PVC casing & caping with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet. | 31 | Point | 300 ₹9,300 Lowest | 300 ₹9,300 Lowest | 458 ₹14,198 | 350 ₹10,850 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
16 Jul 2025, 6:00 pmClosed
Offg GE I R AND D KANPUR
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR MAINT OF INTERNAL ELECTRIC WIRING FITTINGS AND FIXTURES OF MD ACCN OF WAR MEMORIAL COLONY AND MES COLONY UNDER GE I R AND D KANPUR
2025_MES_715144_1
8436/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KANPUR
As per Appx A of NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹28,000
Yes
7 Oct 2025
17 Jun 2025
23 Jul 2025
17 Jun 2025
16 Jul 2025
2 Jul 2025
17 Jun 2025 - 1 Jul 2025
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified.
Point wiring in replacement of one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per srl item No 2.00 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controleed by one switch.
All as per srl item No 2.00 here in above but for one 3 pin 5 Amps socket outlet independent with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controleed by one switch.
All as per srl item No 2.00 here in above but for one 5A socket outlet on the same board with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controlled by one switch.
Point wiring in replacement of one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per srl item No 6.00 here in above but for one socket outlet 5 amps on indipendent board with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controlled by one switch with including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
All as per srl item No 6.00 here in above but for one socket outlet 5 amps on same board with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controlled by one switch including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
All as per srl item No 6.00 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
Point wiring in replacement of one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in PVC casing & caping with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet.
All as per srl item No 10.00 here in above but one 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size
All as per srl item No 10.00 here in above but one 3 pin 5 Amps socket outlet independent switch board of light points in the same vertical plane, with cables, 1.5 sq. mm size
All as per srl item No 10.00 with n above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of piano/modular plate with all accessories as directed.
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 2.5 Sqmm as earth lead in & including concealed PVC conduit medium grade 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
All as per srl item No 14.00 here in above but in existing concealed conduit .
All as per srl item No 14.00 here in above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit .
All as per srl item No 14.00 here in above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm in existing concealed conduit with earth wire 4 sqmm.
M&L for switch piano flush button single pole one way 5/6 amps 240 volts.
S&F switch piano flush button single pole one way 15/16 amps 230 Volts.
M&L for socket 5 amps 5 pin flush type, 230 volts.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts.
M&L for ceiling rose surface bakelite 3 terminals.
S & F Lamp holder insulated body with back plate for dome batten fittings.
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed by engineer-in-charge.
M&L for switch modular type single pole one way 1 module 6 amps 240 volts.
S&F switch modular type one way 1 module 16 amps 230 Volts.
M&L for socket 6 amps modular type 2/3 pin combined 2 module , 230 volts.
M&L for socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts.
S&F electronic regulator modular type one way 1 module 230 Volts.
Supply and fix in replacement wall light fittings 25 watt 6500 extruded heat singk provided for efficient heat dissipation and integrated electric driver complete connection from ceiling rose to light fitting complete all as specified and as directed by the Engr-in-Charge.
S&F in replacement of LED bulk head fitting with opal diffuser min 10 Watt, 6500 K, IP-65, with efficient heat dissipation and integrated electronic driver complete connecting electrically all as directed.
Supply and fix in replacement of High power LED security light 25 Watt IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated complete all as spfd.
S&F in replacement of 15 A Switch Socket Combination with PVC Box as per directed by engineer in charge.
S&F in replacement of 5 A Switch Socket Combination with PVC Box as per directed by engineer in charge.
Supply and Fix in replacement of LED Bulb 9 W all as specified and directed.
S & F in replacement of Decorative Gate Light made up of high grade unbreakable ploycarbonate material Globe type of dia min 200 mm suitable for 9/10 w LED Lamp including fixing of GI pipe of suitable dia, any mm long light grade, partly embedded on column of gate with fixing arrangement complete and making electrical connection complete all as spfd.
S & F in replacement of LED post top lantern 35/40 Watt warm white/white made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP-65 protection including fixing of GI pipe of suitable dia dia, 300 mm long light grade, partly embedded on column of gate with fixing arrangement complete and making electrical connection complete all as spfd.
Supply and fixing in replacement of LED Bollard light fittings 10 Watt IP 65 Asthitically designed landscape luminaire for diffused light suitable for architectureal outdoor light typically giving off light from all side best suitable for illuminate walk ways, step or pathways with fixing arrangement complete and making electrical connection complete all as specified and directed.
S & F distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s VTPN DB 4 way, complete with appropriate size copper bus bar and neutral link including one incomer MCCB 3 pole 415 Volts upto 160 Amps rating with rupturing cap 25 KA of the same make as of distribution board & with 08 Nos MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed.
Supply and fix sheet metal enclosure TPN MCB distribution board, double door with IP-43 IK-09 protection with metal door 3- phase 415 volts 4 way TPN including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification.
Supply and fix sheet metal enclosure SPN MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification.
All as per item No 41.00 but for 8 way.
M&L for MCB single pole 240 volts 5 to 25 amps, with rupturing capacity 10 KA using thimbles of required size.
M&L MCB SPN single pole & neutral 240 volts 30 to 63 amps,with rupturing capacity 10 KA using thimbles of required size.
M&L MCB Three pole & neutral 240 volts 63 amps,with rupturing capacity 10 KA using thimbles of required size.
M&L MCB Three pole 240 volts 63 amps,with rupturing capacity 10 KA using thimbles of required size.
S&F in replacement of MCCB 3 Pole 415 Volts 3 phase 100 Amps 25 KA, thermal magnetic release.
S&F in replacement of MCCB 4 Pole 415 Volts 3 phase 125 Amps 25 KA, thermal magnetic release.
S&F in replacement of MCCB 4 Pole 415 Volts 3 phase 160 Amps 25 KA, thermal magnetic release.
M&L in replacement AC Box steel enclosure plug and socket copmlete with one SP MCB 25 Amps, 240 Volts.
Supply and Fix in replacement of inverter LED Bulb 12 Watt cool day light 240 volt 50 Hz all as specified and directed.
Disconneting electric connection & taking down exhaust fan in replacement of ventil air fan steel body 225mm sweep sitable for kitchen fixing the same, Testing ,complete after fixing for smooth and noise free operation all as specified.
M&L in replacement of earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed incl testing on competion.
Supply & fixing, install testing and commissioning of feeder pillar box ,indoor type plane shape, three phase, 4 wire, copper bus bar for phases and neutral made out of CRCA sheet 2.00 mm thick fabricated , powder coated ,dust and vermin proof , provn for ventilation , pillar box grouted on wall and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar etc all as specified and comprising of following including necessary cable connections to the MCCBs ,MCBs, LED Indicating lamp and cable lugs etc and feeder pillar design approval in Engr-in-charge :- (a) Copper Bus bar with PVC sleeve rating 200 amps for Phase & 200 Amp for neutral - 01Set. (b) Phase indicating lamps LED type ( RYB) 01 Set (c) Incoming MCCB 160 Amp 4 pole 25 KA with adjustable thermal and fixed magnetic release -01 No and MCB TPN 80 Amp with rupturing capacity 10 KA -01 Nos (d) Outgoing MCB TPN 63 Amp with rupturing capacity 10 KA - 04 Nos
Attending the complaints lodged by the occupants/users of electric nature & rectification of the fault as per the complaint lodged by the user in any time (day/Night) in respect of failure /breakdown for light/fan/bell/light or power socket etc complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders ceiling/ Exhaust fans and other type of complaints connected to fittings & fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws , nuts as required to rectify the fault with regard to the complaint lodged and refixing of fittings, fixtures to their position as dismantled and replacement of unserviceable items if required. Replaced items to be paid under respective item as required complete all as directed at site to th entire satisfaction of Engr-in-Charge/users. Note :- (a) No light ,breakdown, repair/ replacement of switches, sockets, fan, regulator, capacitor, replacing burnt/ damaged wiring , replacement of burnt MCBs and main switch , voltage fluctuation, current leakage and replacement of light fittings etc will be attended within 8 Hrs as urgent nature. (b) The complaints will be attended by electricians & respective helpers in each day & night without any delay. (c) The complaint will be taken from complaint cell of War Memorial colony everyday and complaint done same day. . (d) All necessary tools & plants i.e. multimeter, tong tester, spanner set, wrench, screw driver set, combination plier, testing lamp set, drilling machine, bamboo ladder, blower/ vaccum cleaner, crimping tool, cutting and chasing tool, insulation megger etc shall be provided by contractor to electrician at his own cost. (e) Any accident/ mishappening if occur during the execution of work shall be the responsibility of Contractor. (g ) Cost of material and labour for replacement of new items shall be measured and paid separately under relevant items of Sch A. against supply only here-in-after.
Supply only cable of size 6 sqmm single core PVC insulated flexible copper conductor multistranded cable complete all as specified and as directed by the Engr-in-Charge
Supply only cable of size 4 sqmm single core PVC insulated flexible copper conductor multistranded cable complete all as specified and as directed by the Engr-in-Charge
Supply only cable of size 2.5 sqmm single core PVC insulated flexible copper conductor multistranded cable complete all as specified and as directed by the Engr-in-Charge
Supply only cable of size 2.5 sqmm twin core PVC insulated flexible copper conductor multistranded cable complete all as specified and as directed by the Engr-in-Charge
Supply only in replacement switch piano flush button type, 6 Amp one way, 240 Volt, single pole complete all as specified and as directed.
Supply only in replacement socket out let, 2 in 1, 5 pin, 6 Amp, 240 Volt AC, flush type, complete
Supply only switch piano flush button single pole one way 15/16 amps 230 Volt complete all as specified and as directed.
Supply only socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 voltscomplete all as specified and as directed.
Supply only in replacement surface & wall mounted LED batten with PVC housing and robust construction fitting 1x20 Watts including Electronic circuit and 1 x20 Watt LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting complete all as specified and as directed.
Supply only in replacement capacitor/Condensor of 2.5 MFD, 440 Volt AC, conforming to IS - 1709 for ceiling fans, complete all as specified and as directed.
Supply only in replacement fan regulator electronic, step type suitable to control speed of fan.
Supply only in replacement bell push flush type 5 Amp complete all as specified and as directed.
Supply only in replacement bell ding dong AC 230 volts, single pole complete all as specified and as directed.
Supply only in replacement LED light fitting mirror type with high out put diffuser 2 feet, 9/10 watt 220 V AC decorative type with driver holder and LED lamp complete all as specified and as directed.
M&L for painting of in bldg feeder pilar box with spray painting machine with emsynthetic enamelle paint of existing colour two coat and black paint in Angle iron / MS flat after scratcing with sand paper or any other suitable mean up to satisfactory level of engr in Charge and Re-clean the the existing name plate visible by any means complete all as directed.
SUSHMANAND ENGINEERING WORKS (BID ID -3349177)
santosh electronics (BID ID -3347606)
YS CONSTRUCTION (BID ID -3350811)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .