Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC NEAR LIC OFFICE KALAIGNAR ARIVALAYAM SHOP ROOM NO7 GROUND FLOOR OF BACK SIDE PHOENIX BAY SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.4 L+₹5.4 L (13.4%)Rejected-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-AOC L2 | |
| 3 | L3₹46.3 L+₹6.3 L (15.8%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Enlisted in Required Cat | |
| 5 | Rejected-Technical 956 2 CHANDERSEKER ENTERPRISE OPP MARICAR HOSPITAL OLD CCS JUNGLIGHAT SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | - | Rejected-Technical Not Enlisted in Required Cat |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Brichgunj
GE Brichgunj, Port Blair
REPAIR/MAINTENANCE OF SUMMER COOLING / HEATING APPLIANCES AND RELATED WORKS AT BIRCHGUNJ UNDER GE BIRCHGUNJ
2022_MES_528073_1
GE8226A
Open Tender
Civil Works
Item Rate
270 days
GE Brichgunj
as per tender documents
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹80,000
Yes
26 Jul 2022
2 Jun 2022
25 Jun 2022
2 Jun 2022
23 Jun 2022
16 Jun 2022
60 days
Amount
M&L for servicing of window type air conditioner of 1.5/2.0 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position all as specified and as directed.
Dismantling the following unservicable items from window type air conditioner of capacity 1.5 Ton of any make and any type and replacing the same with new one including testing and commissioning the same all as specified and as directed. Compressor under manufacturers exchange scheme.
Blower motor single phase, 1/5 hp, 1100 rpm, 130 watts, 240 volts
Over load protector
Thremostat
Starting capacitor 80/100 mfd 230 volts
Running capacitor 36 mfd 230 volts
Starting relay
Blower motor fan blade set
Rubber mounting bush for blower motor
S&F in repairs copper condensor coil suitable for 1.5/2 T Split/window AC complete all as specified and as directed
M&L for servicing of split type air conditioner of 2.0 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position all as specified and as directed
M&L for servicing of split type air conditioner of 1.5 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position all as specified and as directed.
Dismantling the following unservicable items from split type air conditioner of capacity 1.5/2.0/4.0 Ton of any make and any type and replacing the same with new one including testing and commissioning the same all as specified and as directed. Compressor for 1.5 ton split type air conditioner under manufacturers exchange scheme.
Compressor for 2.0 ton split type air conditioner under manufacturers exchange scheme.
Compressor for 4.0 ton split type air conditioner under manufacturers exchange scheme.
Bower motor for 1.5 ton split type air conditioner
Bower motor for 2.0 ton split type air conditioner
Starting capacitor for 2.0 ton split type air conditioner, 100/120 mfd 230 volts
Starting capacitor for 1.5 ton split type air conditioner, 80/100 mfd 230 volts
Running capacitor for 1.5 ton split type air conditioner, 36 mfd 230 volts
Running capacitor for 2.0 ton split type air conditioner, 45 mfd 230 volts
Starting relay for 1.5/2.0 ton split type air conditioner
PCB Electronic control board for 1.5/2.0 ton split type air conditioner
Insulation rubber hose 12mm for split AC any type
Hand Remote set for 1.5/2.0 ton split type air conditioner
Outer brass valveof size 5/8" for out door unit of split AC 2 ton
Outer brass valveof size 3/8" for out door unit of split AC 2 ton
Outer brass valveof size 1.5" for out door unit of split AC 1.5 ton
Outer brass valveof size 0.25" for out door unit of split AC 1.5 ton
MS Stand for outer unit of split AC 1.5/2 ton capacity.
Expansion valve with capillary for window/split type AC
Dismantling the following unservicable items from water cooler storage type 40/80 and 60/120 ltrs cooling of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed. Compressor under manufacturers exchange scheme 60/120 Ltrs capacity.
Compressor under manufacturers exchange scheme 40/80 Ltrs capacity.
Fan motor 60/120 ltrs capacity.
Fan motor 40/80 ltrs capacity.
Thermal over load protector 40/80 ltrs capacity.
Starting relay 40/80 and 60/120 ltrs capacity.
Thermostat 40/80 and 60/120 ltrs capacity.
Starting capacitor 80/100 mfd 230 volts
Running capacitor 10 mfd 230 volts
Self closing tap of chromium plated brass, size 15mm
Dismantling the following unservicable items from Refrigerator 175 to 220 Ltrs capacity of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed. Compressor under manufacturers exchange scheme.
starting relay
Aluminium cooling coil/Freezer coil
condensor coil
Thermostat
Limit Switch
Dismantling the following unservicable items from Refrigerator 280 to 310 Ltrs capacity of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed. Compressor under manufacturers exchange scheme.
starting relay
Aluminium cooling coil/Freezer coil
condensor coil
Thermostat
Dismantling the following unservicable items from deep Freezer 205/330 Ltrs capacity of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed. Compressor under manufacturers exchange scheme.
starting relay
Thermostat
Starting capacitor for deep Freezer, 80/100 mfd 230 volts
Running capacitor for deep Freezer, 36 mfd 230 volts
Taking down unserviceable Split AC 1.5 Ton/2 Ton and deposit E&M store and refixing serviceable unit complete in position all as specified and as directed.
M&L for charging of refrigerant gas R-404 a for water cooler of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed.
M&L for charging of refrigerant gas R-22 for Air conditioners of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed.
M&L for charging of refrigerant gas R-134 (a) in Refrigerator of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed.
Taking down storage type water heater of 50 ltrs capacity of any make and any type and disconnecting inlet/outlet pipe connections complete, including dismantling and servicing, leak testing compltely and refixing the same in position with suitable nuts and bolts and connecting inlet/outlet connections including testing and commissioning all as specified and as directed.
Taking down storage type water heater of 25 ltrs capacity of any make and any type and disconnecting inlet/outlet pipe connections complete, including dismantling and servicing, leak testing compltely and refixing the same in position with suitable nuts and bolts and connecting inlet/outlet connections including testing and commissioning all as specified and as directed.
S&F in repairs Heating element of 1500 watts, 240 volts suitable for existing complete all as specified and as directed.
S&F in repairs Heating element of 2000 watts, 240 volts suitable for existing complete all as specified and as directed.
S&F in repairs Thermostat element suitable for 25/50 ltrs capacity water heater, suitable for existing complete all as specified and as directed.
S&F in repairs Geyser "Hot & Cold" PVC pipe line connecting to stop cock off 15mm dia, 450mm length all as specified and as directed.
Supply and fix scotch screw 10mm for installation of water heater.
Supply and fix neon bulb red and green in colour for indication of water heater.
Supply and fix top cover of water heater
Supply only bottom cover of water heater
Supply and fix plug top 15 Amps
Supply and fix 3 core 1.5sqmm copper cable
M&L for pressure testing the compressor unit including connecting pipe line with nitrogen gas and holding the appropriated pressure for approved period (as per manufactureal instruction) and rectify the leakages by means of welding, soldering/brazing etc for window/splitt type air conditioner/ water cooler/refrigerator of any capacity and make, including testing and commissioning complete all as specified and as directed.
M&L Repair to voltage stabilizer 5.0/4.0 KVA capacity AC, SP 240 volts including replacement of relays and electronic printed circuit board (PCB) with brand new relays & PCBs and testing on completion all as specified and as directed.
M&L Repair to voltage stabilizer 0.5 to 3 KVA capacity AC, SP 240 volts including replacement of relays and electronic printed circuit board (PCB) with brand new relays & PCBs and testing on completion all as specified and as directed.
S & F 20 A MCB DBOXX COMBO Plastic Enclosure complete with one MCB, SP, 20 Amps, 240 Volts fixed complete all as specified and as directed.
M & L for AC point sub main wiring with 3 runs (Phase, neutral, earth) of 4 Sq.mm PVC Insulated Unsheathed single core cable, 1100 Volts Grade Multistranded with Copper Conductor drawn through and including PVC Casing and Caping (or) PVC conduit of 20mm dia non metalic rigid with conduit accessories fixed to walls/roofs/floors etc and One run of 4 Sq.mm Single Core Multistranded Copper Conductor as earth continuity conductor all as specified and as directed. (Note: 2 runs of 4 Sq.mm & 1 run of 4 Sq.mm earth conductor will be measured as one running metre)
Supply and fix in repair of PVC conduit 20mm for drain out of air conditioner, complete all as specified and as directed.
Supply and fix in repair copper tube of size 5/8 with insulation rubber hose, complete all as specified and as directed.
Supply and fix in repair copper tube of size 1/2 with insulation rubber hose, complete all as specified and as directed.
Supply and fix in repair copper tube of size 3/8 with insulation rubber hose, complete all as specified and as directed
Supply and fix in repair copper tube of size 1/4 with insulation rubber hose, complete all as specified and as directed
Taking out and dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the exhaust fan of size 300mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling refixing at same/ required location, complete all as specified and as directed.
Taking out and dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the exhaust fan of size 400/450mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling refixing at same/ required location, complete all as specified and as directed.
Supply and fix in repairs condensor 4/3.5 mfd, AC 230 volts, 50 Cycles, complete all as specified and as directed.
Supply and fix in repairs ball bearing suitable for exhaust fan of any sweep and make complete all as specified and as directed.
Taking down exhaust fan of any size/sweep from existing position complete with blades from brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Supply and fix ball bearing suitable for exhaust fan of any sweep and make complete all as specified and as directed.
Supply and fix condensor 4 mfd AC 230 volts 50 cycles, complete all as specified and as directed.
Taking down wall mounted fan of any size/sweep from existing position complete with bladesfrom brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Supply and fix ball bearing suitable for wall mounted fan of any sweep and make complete all as specified and as directed.
Taking out and the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the wall mounted fan of size 400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed.
Supply and fix wall mounted fan covering Net
Supply and fix wall mounted fan blade
Supply and fix capacitor 2 mfd for wall fan.
Dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding with new rotor shaft the ceiling fan of size 1200mm/1400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed.
Supply and fix in repalcement canopy of ceiling fan, complete all as specified and as directed.
Supply and fix in repalcement ceiling fan hanging clamp with bush, locking pin and nut and bolt, complete all as specified and as directed.
Dismantling and taking down ceiling fan of any size/sweep from existing position complete with blades, down rod and canopy etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Supply and fix ball bearing suitable for ceiling fan of any sweep and make complete all as specified and as directed.
Supply and fix down rod of appropriate size suitable for ceiling fan of any sweep and make complete all as specified and as directed.
Supply and fix fan condensor 2.5 mfd AC 240 volts 50 Hz complete all as specified and as directed.
Tropical Refrigeration
MGP Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .