1) Augmentation of Video Surveillance system at 05 station (HD, SCI, BAQ, GUNA, SVPI) of Bhopal Division. 2) Provision of CCTV for yard coverage of mainline facing points at Misrod, Kurwai Kathora and Nishatpura station of Bhopal Division.
BPLNWKS2025-26TELE05~WCR
BPLNWKS2025-26TELE05
Open
Works - General
6 Months
Bhopal, Madhya Pradesh
₹0
₹2.8 L
29 Dec 2025
6 Dec 2025
15 Dec 2025
01-Schedule A (Supply-Augmentation of Video Surveillance system at
02-Schedule B (Execution- Augmentation of Video Surveillance system
03-Schedule C (Supply- Provision of CCTV for yard coverage of mainline
04-Schedule D (Execution-Provision of CCTV for yard coverage of
BAQ, GUNA, SVPI) of Bhopal Division.)
Item- 01 Total of Sch A (Supply)
S No. Item Description of Item Unit Qty Rate Amount
1 01 Supply, Installation, Testing and Numbers 20.00 15398.91 307978.20
Commissioning of Full HD Fixed Bullet type IP
Colour Camera along with 128 GB or Higher
SD Card, housing and mount and all
accessories required for installation purposes
per RDSO Spec No RDSO/SPN/TC/65/2021,Rev
6.0 with amdt. 1,2 & 3 or latest. (It should be
compatible with existing system of VSS).
Inspection Authority: RDSO
2 02 Supply, Installation, Testing and Numbers 10.00 36803.99 368039.90
Commissioning of Full HD PTZ type IP Colour
Camera along with 128 GB or Higher SD Card,
housing and mount and all accessories
required for installation purposes as per
RDSO Spec No RDSO/SPN/TC/65/2021, Rev
6.0 with amdt. 1,2 & 3 or latest. (It should be
compatible with existing system of VSS).
Inspection Authority: RDSO
3 03 Supply, Installation, Testing and Numbers 10.00 14609.22 146092.20
Commissioning of Full HD Fixed Dome type IP
Colour Camera along with 128 GB or Higher
SD Card, Housing & Mount and all accessories
required for installation purposes as per
RDSO Spec No RDSO/SPN/TC/65/2021,Rev 6.0
with amdt. 1,2 & 3 or latest. (It should be
compatible with existing system of VSS).
Inspection Authority: RDSO
4 04 Supply Installation, Testing and Numbers 40.00 3896.18 155847.20
Commissioning of Software for VMS and
Video Recording software. (Per camera
License means Video Management and video
recording at multiple locations such as
Station, RPF Post & DC Server room covered
by the same license) as per technical spec.
and functional requirementas per RDSO Spec
No RDSO/SPN/TC/65/2021 Rev.6 with amdt.
1,2 & 3 or latest.(It should be compatible with
existing system of VSS). Inspection Authority:
5 05 "Supply Installation, Testing and Numbers 5.00 794553.41 3972767.05
Commissioning of Server Hardware for Face
Recognition Complete with all accessories as
per Clause No. 10.1.1.3 Spec No
RDSO/SPN/TC/65/2021, Rev.6.0 with amdt.
1,2 & 3 or latest. Inspection Authority: RDSO"
6 06 Supply, Installation, Testing and Numbers 25.00 214075.67 5351891.75
Commissioning of FRS software complete
with all accessories (License per camera
basis), by same license, Face Recognition can
be possible at multiple locations such as
Station, RPF Thane and security control room
as per Clause No.19.0 Spec No
RDSO/SPN/TC/65/2021,Rev 6.0 with amdt. 1,2
& 3 or latest. Inspection Authoruty: RDSO
Commissioning Analytic Hardware and all
accessories required for installation purpose
As per Clause No. 10.1.1.3 RDSO Spec No
RDSO/SPN/TC/65/2021 with amdt. 1,2 & 3 or
latest. Inspection Authoruty: RDSO"
BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
8 08 "Supply, installation Testing & Commissioning Lot 40.00 9847.48 393899.20
of Storage System for 30 days recording at
Station/ RPF/GRP Thane/Post/Sites for
recording of Cameras from cluster of station
along with all accessories required for
installation purposes . Note: Bidders are
required to quote price for complete storage
as a LOT at each RPF Thana of Division for all
types of Cameras mentioned in the Schedule
as per RDSO Spec No. RDSO/SPN/TC/65/2021,
Rev 6.0 with amdt. 1,2 & 3 or latest.
Inspection Authority: RDSO"
9 09 "Supply, installation Testing & Commissioning Numbers 25.00 7492.65 187316.25
of Panic Switch (IK10 and IP 66 Rated) with
Mushroom Cap Push-Button in Red Color,
DPDT contacts 2 Amps , Stainless Steel Face
Plate with GI Junction Box of suitable size and
flasher cum strobe of min. 100dB including
fixing arrangements and suitable protection
and all accessories required for installation
on each platform at stations or as per site
requirement. Inspection Authority: RDSO "
10 10 "Supply Installation Testing and Numbers 5.00 278298.37 1391491.85
Commissioning of PC Work Station suitable
for Viewing, Monitoring and System
Management as per RDSO Spec No
RDSO/SPN/TC/65/2021, Rev.6.0 with amdt.
1,2 & 3 or latest.(It should be compatible with
existing system of VSS) Inspection Authority:
11 11 "Supply Installation & Commissioning of Layer Numbers 25.00 47498.60 1187465.00
2 Manageable, 24 Port POE, 24
GE10/100/1000 BaseX Ethernet port with
POE+ support and 4x1GE SFP Port for uplink
with 4 no of 1GE BX SM SFP modules fully
loaded, with all accessories as per
RDSO/SPN/TC/65/2021, Rev.6.0 with amdt.
1,2 & 3 or latest. (Switch Should be TTP
approved). Inspection Authority: RDSO"
12 12 "Supply, Installation, Testing and Numbers 5.00 82176.18 410880.90
Commissioning of 24 port manageable Layer
3 switch with 4 Nos of 10G SFP port (fully
loaded) and 24 Nos of GE port (fully loaded
with 12 optical and 12 electrical SFP's) with
all accessories as per Spec. No:
RDSO/SPN/TC/65/2021, Rev.6.0 with amdt.
1,2 & 3 or latest. (Switch Should be TTP
approved). Inspection Authority: RDSO "
13 13 Supply, Installation, testing and Numbers 10.00 10953.34 109533.40
commissioning of 8 port POE manageable
field switch with two fiber ports(1G SFP
loaded)as per RDSO Spec No
RDSO/SPN/TC/65/2021,Rev 6.0 or latest with
amdt. 1,2 & 3 or latest. (Switches to be
procured from TTP approved sources)
Inspection Authority: RITES.
14 14 "Supply of STP Cat 6 cable it should be Metre 5000.00 49.18 245900.00
compliant with latest EIA/TIA-568-B.2-1
standard Make-D-link/syrotech/Digisol or
similar. Inspection Authority: Consignee."
15 15 "Supply of CAT6 UTP cable 4 pair in box of Boxes 20.00 4430.73 88614.60
1000 feet. it should be compliant with latest
EIA/TIA-568-B.2-1 standard Make -D-
link,Delton/Finolex, Havells or similar.
Inspection Authority: Consignee."
BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
16 16 Supply of power cable 3 core copper (PVC Metre 7500.00 47.62 357150.00
insulated flexible) 3 core X 2.5 Sq. mm.
multistrand power cables should conform to
specification no. IS: 694:1990 reaffirmed
1995 or latest. Make: D-link,Delton/Finolex,
Havells or similar. Inspection Authority:
17 17 Supply and wiring of 3 core 4 sq mm, multi Metre 2000.00 197.40 394800.00
strand copper conductor, PVC insulated
armoured power cable, confirming to IS:1554
Part-I with OEM test report Make:
Finolex/polycab/Orbit or similar. Inspection
Authority: Consignee.
18 18 "Supply of OFC single mode 6 fiber armoured Metre 5500.00 36.08 198440.00
cable. This shall comply standards ISO: 11801
and TEC specification 85010:2003 or latest
Make: finolex/polycab/Paramount or similar.
Inspection Authority: Consignee."
19 19 Supply and installation of 19" 6U Rack of Numbers 15.00 4541.82 68127.30
size: 600mm width x 500 mm deep with
hinge door cooling fan, 6 Socket power
extension board of 230V/5A, cable manager,
partitiontray and accessories with locking
arrangement on both door and wall mount
arrangement, front section with glass door
and lock. Make: Comrack, Rittel,APW,
President, HCL, D-link or similar. Inspection
Authority: Consignee.
20 20 Supply and fixing of outdoor 6U cabinet/rack Numbers 10.00 7852.00 78520.00
IP66 suitable for fixing switch/UPS etc . The
cabinet should be fixed in the out door pole.
necessary power adapter and all accessories
required for this work shall be supplied by the
contractor. Make : Rackom or similar.
Inspection Authority: Consignee.
21 21 "Supply, Installation and Commissioning of Numbers 4.00 639176.20 2556704.80
2x10 KVA UPS at least 2 Hour Back up in full
load condition, connected in parallel
redundant mode. with complete all
accessories, as per specification attached as
Annexure A. This also includes supply of two
set MF batteries of suitable AH capacity, rack,
one set compatible MCBs complete with cover
& fixing materials and one earth leakage
circuit breaker arrangement. Inspection
Authority: RITES"
22 22 "Supply of 6 port rack mount LIU loaded with Numbers 15.00 28579.57 428693.55
LC/SC/FC coupler and suitable patch chord as
per site requirement. Inspection authority:
RDSO/SPN/TC/45/2013 Rev.2.0 with latest
amendments as available. For each KM of
HDPE DUCT following items are to be supplied
a) End plugs-2no b) Cable sealing plugs-2 no.
c) Plastic couples slip fit/pushfitb type-2 no d)
End plugs to be provided along with drum-2
nos. Inspection Authority: Consignee
Schedule 02-Schedule B (Execution- Augmentation of Video Surveillance system at 05 station (HD,
SCI, BAQ, GUNA, SVPI) of Bhopal Division.)
Item- 01 Total of Sch B (Execution)
S No. Item Description of Item Unit Qty Rate Amount
BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
1 01 Supply and fixing of PVC casing caping 25mm Metre 12500.00 31.91 398875.00
(1 inch) with all accessories. This includes
drawing/laying of telecom cables/OFC/Power
cable through casing caping and termination
of wire at end point and work should be
carried out as per the instruction of Railway
site engineer. (Inspection authority:
2 02 Laying of Power cable through PVC conduit Metre 5500.00 19.17 105435.00
pipe/Capping casing with all required
accessories, as per instruction of Site
3 03 Splicing/ Dropping/ Termination/ Fixing of Numbers 625.00 159.70 99812.50
each fiber/ pigtail in the LIU/IO Box/Terminal
joint through fusion splicing for termination of
OFC cables. The fiber terminated shall be
tested & test report (Hard copy & Soft Copy)
shall be submitted to the Railway for records.
Each fiber shall be properly marked with
necessary ferrules/ tags.
4 04 Supply and Erection of 15 feet Stainlesssteel Numbers 10.00 3958.23 39582.30
(SS) pipe of 4'' dia of 304 grade (3mmthick
+/-5% tolerance) Having SS base plate 10mm
thick 30cm x 30cm weld at the bottom of the
pipe with 4 supports of SS bars of size 10 mm
dia. The 3 feet pipe shall be buried in the
ground and 12 feet shall be above the
ground. The work includes digging of pit on
platform, laying of cable, erection of pole,
filling the pit with 1:3:4 cement, concrete and
sand. Final plastering should be done on the
surface. The SS bracket on the top of the pole
shall be provided for the fixing of CCTV
camera and metal junction box/6U outdoor
cabinate with locks and key arrangement
with IP66 rating to avoid water entry, to
accommadate FMS,5/15A Power sockets of 3
No.s, Media converter etc. (Necessary fixing
and other materials including supply of FMS,
Splicingof fibers, 5/15A socket with switches
3No.sand termination of power cable etc.
required for fixing should be borne by the
contractor). Inspection by Consignee.
5 05 Supply & Installation of PVC Box water proof Numbers 10.00 606.39 6063.90
at Camera end. Inspection by Consignee.
6 06 Excavation of trench as per cable route plan Kilometre 2.00 65305.64 130611.28
1.2 mtr deep, 300mm wide at the bottom
along main line in normal soil. This work
includes covering of cable laid in trenches by
loose soil for a layer of 50 mm thickness
approximately clearing of route, bushes etc
and refilling of the trench by excavated soil
and ramming after laying of the required
quantity of cables as per instructions of
Engineer at site. If it is not possible to reach
the required depth at any location then the
contractor shall obtain prior approval of
Engineer-in-charge before commencement of
cable laying process and only then their shall
be the proportionate payment be made to the
7 07 Cutting of all types of platform, trenching & Metre 200.00 250.00 50000.00
excavation to depth of 300mm X 300mm
wide approx. and refilling after laying of
RCC/DWC/GI pipes and repairing after laying
of RCC/DWC/GI pipes and repairing the
platform to restore to original condition. The
work shall be done as per extant practice on
W.C Rly and as per instruction of Rly Engineer
BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
8 08 Cutting of all types of Roads prepratory to Metre 50.00 217.56 10878.00
trenching & excavation to depth of 1 Mtr x
300 mm wide approximately and refilling
after laying of DWC/GI pipes and restore to its
original condition. The work shall be done as
per extant practice on W.C.Rly & instruction
of Rly engineer at site.
9 09 Transportation and laying of HDPE pipe as Kilometre 4.00 5838.67 23354.68
per approved cable route plan in the
excavated trench taking due care while
transporting and laying the same in the
tranches or other protective works. Both the
end of duct should be sealed with end plugs
10 10 Blowing/Drawing of OFC cable in HDPE/DWC Kilometre 2.00 13400.00 26800.00
duct and in protective work as per instruction
of site engineer.
11 11 Laying of various cables (Telecom Metre 2000.00 6.14 12280.00
cable/Power cable) as per the approved cable
route plan in the excavated trench, inside
GI,DWC pipes etc. and inserting the cable in
building taking due care while transporting
and laying. The cable are to be laid as per
extant practice of West Central Railway and
as per instructions of Engineer.
Schedule 03-Schedule C (Supply- Provision of CCTV for yard coverage of mainline facing points at
Misrod, Kurwai Kathora and Nishatpura station of Bhopal Division.)
Item- 01 Total of Sch C (Supply)
S No. Item Description of Item Unit Qty Rate Amount
1 01 Supply of Full HD PTZ type IP Colour Camera Numbers 8.00 36176.98 289415.84
along with 128 GB or Higher SD Card,
housing and mount and all accessories
required for installation purposes as per
RDSO Spec No RDSO/SPN/TC/65/2021, Rev
6.0 with amdt. 1,2 & 3 or latest. (It should be
compatible with existing system of VSS).
Inspection Authority: RDSO
2 02 Supply of 12 core OFC cable with armoured Metre 2000.00 17.11 34220.00
ECCS tape (single mode fiber-OS1 ) as per
conforming to IEC 60793-1, IEC 60793-2, and
to confirm other normative specifications as
specified in IEC:60793 Part 1 and Part 2.
Make: Network cables or similar. Inspection
Authority: Consignee
RDSO/SPN/TC/45/2013 Rev.2.0 with latest
amendments as available. For each KM of
HDPE DUCT following items are to be supplied
a) End plugs-2no b) Cable sealing plugs-2 no.
c) Plastic couples slip fit/pushfitb type-2 no d)
End plugs to be provided along with drum-2
nos. Inspection Authority: Consignee
4 04 Supply and wiring of 3 core 4 sq mm, multi Metre 2000.00 197.40 394800.00
strand copper conductor, PVC insulated
armoured power cable, confirming to IS:1554
Part-I with OEM test report Make:
Finolex/polycab/Orbit or similar. Inspection
Authority: Consignee.
5 05 "Supply of STP Cat 6 cable it should be Metre 610.00 49.18 29998.73
compliant with latest EIA/TIA-568-B.2-1
standard Make-D-link/syrotech/Digisol or
similar. Inspection Authority: Consignee."
6 06 Supply and Installation of 5 Mtrs length CAT6 Numbers 18.00 351.71 6330.78
UTP patch chord (RJ45) factory crimped
Make: D-Link, DAX, MOLEX, KRONE or similar.
Inspection Authority: Consignee.
BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
7 07 Supply of patch chord 3 meter long of CAT 6 Numbers 12.00 218.00 2616.00
UTP Cable factory crimped. Make: D-link,
syrotech, Digisol or similar of reputed make.
(Inspection authority: Consignee)
8 08 Supply of fiber optic patching cord 5 Mtrs Numbers 16.00 315.00 5040.00
length LC-SC/SC-SC//LC-LC , as per
requirement Make: D-link, syrotech, Digisol or
similar of reputed make. Inspection authority:
9 09 Supply of RJ-45 Connectors. Make: D Link, Boxes 20.00 379.02 7580.40
Digisole, Spectra, Dax, Megabyte, Opti link or
similar. (1 Box=100 Nos.)
10 10 "Supply Installation & Commissioning of Layer Numbers 2.00 47498.60 94997.20
2 Manageable, 24 Port POE, 24
GE10/100/1000 BaseX Ethernet port with
POE+ support and 4x1GE SFP Port for uplink
with 4 no of 1GE BX SM SFP modules fully
loaded, with all accessories per
RDSO/SPN/TC/65/2021, Rev.6.0 with amdt.
1,2 & 3 or latest. (Switch Should be TTP
approved). Inspection Authority: RDSO"
11 11 "Supply, Installation, Testing and Numbers 2.00 82176.18 164352.36
Commissioning of 24 port manageable Layer
3 switch with 4 Nos of 10G SFP port (fully
loaded) and 24 Nos of GE port (fully loaded
with 12 optical and 12 electrical SFP's) with
all accessories as per RDSO Spec No
RDSO/SPN/TC/65/2021,Rev 6.0 or latest with
amdt. 1,2 & 3 or latest. (Switch Should be TTP
approved). Inspection Authority: RDSO"
12 12 Supply, Installation, testing and Numbers 16.00 10953.34 175253.44
commissioning of 8 port POE manageable
field switch with two fibre ports(1G SFP
loaded)as per RDSO Spec No
RDSO/SPN/TC/65/2021,Rev 6.0 or latest with
amdt. 1,2 & 3 or latest. (Switches to be
procured from TTP approved
sources).Inspection authority: Consignee
13 13 Supply of on-line UPS 1 KVA with battery Numbers 4.00 33981.36 135925.44
backup of 60 minutes with minimum spec.
are as under: Technology: IGBT-PWM. Input
Power: Three phase, 300 V - 450,sinewave:
50Hz, out power: Single phase 230Volt,
warranty: 3 years. Make/Brand: APC,
Luminous, AMCO or similar. (Inspection
authority: RITES)
14 14 Supply & Installation of PVC Box water proof Numbers 8.00 606.39 4851.12
at Camera end. (Inspection authority:
15 15 Supply and fixing of PVC casing caping 25 Metre 250.00 31.91 7977.50
mm (1 inch) with all acessories. This includes
drawing/laying of telecom cables/OFC/Power
cable through casing caping and termination
of wire at end point and work should be
carried out as per the instruction of Railway
site Engineer. (Inspection authority:
16 16 "Supply and fixing of different size PVC casing Metre 400.00 27.62 11048.00
and capping in slotted channel through
confirming to IS standard as required by
Railways at size 47/50 mm . By
fixing/clamping at a regular interval to the
wall for indoor wiring Make Sudhaker /Modi
/Sun / Finolex/AKG or similar. (Inspection
authority: Consignee) "
17 17 Supply of earth electrode assembly as per Numbers 4.00 902.52 3610.08
Drg. Nos.CR/SK-753. (Inspection authority:
BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
18 18 Supply of DWC pipe made of polythene of Metre 24.00 326.48 7835.52
size 103.5 mm inner dia and 120 mm outer
dia. in 6 m length as per IS 14930 part-II
along with 1coupler per pipe as per
specification IP 67 grade for every 6 mtrs.
(Inspection authority: Consignee)
19 19 Supply and Provision of multi pin power Numbers 4.00 2385.00 9540.00
socket with switch of 5A/15A (6 nos.) wired
with 2.5 Sq.mm copper multistrand wire as
per site requirement and instruction of site
incharge. (Inspection authority: Consignee)
20 20 Supply of 6A, Double Pole with 2PP 240V Numbers 4.00 587.45 2349.80
MCB, Make: Havells, Anchor or similar
(Inspection authority: Consignee)
21 21 Supply of Aluminium Platform single pole step Numbers 2.00 10800.00 21600.00
ladder of total extended height of 12 feet,
Retracted Height 2 feet, step width 2.5
inches, Gap between Step 1 feet, Maximum
Load Capacity kg 140 kg, Maximum Weight of
Ladder 10 kg. (Inspection authority:
Schedule 04-Schedule D (Execution-Provision of CCTV for yard coverage of mainline facing points at
Misrod, Kurwai Kathora and Nishatpura station of Bhopal Division.)
Item- 01 Total of Sch D (Execution)
S No. Item Description of Item Unit Qty Rate Amount
1 01 Excavation of trench as per cable route plan Kilometre 1.40 65305.64 91427.90
1.2 mtr deep, 300 mm wide at the bottom
along main line in normal soil. This work
includes covering of cable laid in trenches by
loose soil for a layer of 50 mm thickness
approximately clearing of route, bushes etc
and refilling of the trench by excavated soil
and ramming after laying of the required
quantity of cables as per instructions of
Engineer at site. If it is not possible to reach
the required depth at any location then the
contractor shall obtain prior approval of
Engineer-in-charge before commencement of
cable laying process and only then their shall
be the proportionate payment be made to the
2 02 Excavation of cable trench as per cable route Kilometre 0.40 116079.60 46431.84
plan, 1 mtr. Deep and 300 mm wide along
side the track in hard soil, confirming to
distances as per cable route plan and refilling
after cable laying. This work includes covering
of cable laid in trenches by loose soil for a
layer of 50 mm thickness approximately
,clearing of route, bushes etc and refilling of
the trench by excavated soil and ramming
after laying of the required quantity of cables
as per instructions of Engineer at site. The
work shall be done as per extant practice on
W.C.Rly. & instruction of Rly. engineer at site.
In case depth of trench not achievable due to
site conditions proportionate payment will be
3 03 Excavation of cable trench 1 mtr. deep and Metre 100.00 185.73 18573.00
300 mm wide across the track, for track
crossing and refilling after laying of
DWC/RCC/GI pipes and restore the track to its
original condition. The work shall be done as
per extant practice on W.C. Rly & instruction
of Rly engineer at site.
BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
4 04 "Cutting of all types of Roads prepratory to Metre 80.00 217.56 17404.80
trenching & excavation to depth of 1 Mtr x
300 mm wide approximately and refilling
after laying of DWC/GI pipes and restore to its
original condition. The work shall be done as
per extant practice on W.C.Rly & instruction
of Rly engineer at site."
5 05 Cutting of all types of platform (Tiles/slab), Metre 465.00 250.00 116250.00
trenching & excavation to depth of 300mm X
300mm wide approx. and refilling after laying
of RCC/DWC/GI pipes and repairing after
laying of RCC/DWC/GI pipes and repairing the
platform to restore to original condition. The
work shall be done as per extant practice on
W.C Rly and as per instruction of Rly Engineer
6 06 Transportation and Laying of GI/DWC/RCC Metre 24.00 73.20 1756.80
pipes along with collars in trenches at places
wherever required asper the instruction of
the engineer at site.
7 07 "Transportation and Laying of HDPE pipe as Kilometre 2.00 5838.67 11677.34
per approved cable route plan in the
excavated trench, taking due care while
transporting and laying the same in the
trenches or other protective works. Both the
ends of the duct should be sealed with end
plugs before laying and should remain sealed
till blowing is done"
8 08 Blowing/Drawing of OFC cable in HDPE/DWC Kilometre 2.00 13400.00 26800.00
duct and in protective work as per instruction
of site engineer.
9 09 Laying of various cables (Telecom Metre 2000.00 6.14 12280.00
cable/Power cable) as per the approved cable
route plan in the excavated trench, inside
GI,DWC pipes etc. and inserting the cable in
building taking due care while transporting
and laying. The cable are to be laid as per
extant practice of West Central Railway and
as per instructions of Engineer.
cable/Power/OFC in one inch dia PVC conduit
pipe or HDPE pipe as per site condition. The
rate includes laying and installation/clamping
charges of PVC pipe/HDPE pipe with
protective arrangements.
11 11 Splicing/Dropping/Termination/Fixing of each Numbers 48.00 159.70 7665.60
fibre/pigtail in the LIU/IO Box/ Terminal joint/
straight joint through fusion splicing of
termination of OFC cables The fibre
terminated shall be tested & test report (Hard
copy & Soft Copy) shall be submitted to the
Railway site for records. Each fiber shall be
properly marked with necessary ferrules/tags.
12 12 Supply and Termination of FMS Rack Numbers 8.00 5500.00 44000.00
mounting type 19"size for 12F with SC-PC
connector loaded with pigtails and
termination and splicing of OFC cable as per
Rly requirement and fixing in Rack as
directed by Engineer representative at site
(OTDR readings to be taken and to be
submitted for 1310 & 1550 nm) (This includes
Transportation of materials from Nominated
stores to site). (Inspection authority:
BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
13 13 Installation, Testing and Commissioning of Numbers 8.00 627.01 5016.08
Full HD P/T/Z/ (Pan/Tilt/Zoom) IP Colour
Camera with ceiling mount kit as per RDSO
Specification No. RDSO/SPN/TC/65/2021,Ver.
6 with Amdt. 1 & 2 or latest along with
housing, mounting, fixing and All the
accessories required for the installation are to
be supplied by the contractor (The camera
shall be fixed with stainless steel clamps of
304 grade of suitable dia 50 mm (min)/50mm
square with 3mm +- 5% tolerance and
thickness as decided by railway
representative at site)
14 14 Supply and Erection of 15 feet Stainless steel Numbers 4.00 3958.23 15832.92
(SS) pipe of 4'' dia of 304 grade (3mmthick
+/-5% tolerance) Having SS base plate 10mm
thick 30cm x 30cm weld at the bottom of the
pipe with 4 supports of SS bars of size 10 mm
dia. The 3 feet pipe shall be buried in the
ground and 12 feet shall be above the
ground. The work includes digging of pit on
platform, laying of cable, erection of pole,
filling the pit with 1:3:4 cement, concrete and
sand. Final plastering should be done on the
surface. The SS bracket on the top of the pole
shall be provided for the fixing of CCTV
camera and metal junction box/6U outdoor
cabinate with locks and key arrangement
with IP66 rating to avoid water entry, to
accommadate FMS,5/15A Power sockets of 3
No.s, Media converter etc. (Necessary fixing
and other materials including supply of FMS,
Splicing of fibers, 5/15A socket with switches
3No. sand termination of power cable etc.
required for fixing should be borne by the
contractor). Inspection by Consignee.
15 15 Supply & Fixing of Stainless steel (SS) pipe Metre 96.00 465.00 44640.00
with suitable SS couplers (50 mm dia
3mmthick +/- 5% tolerance. SS304 grade)
from floor to Roof/FOB with suitable Stainless
steel clamps for every one meter and
construction of masonary work for closing
gap in the cable entry of pipe from floor for
every Roof/FOB (Masonry work in
1Fx1FX1Fdimension) (The work shall be
carried out as per the instruction of Railway
Engineer at site) (The SS pipe, cement, sand,
stone chips, bricks and all other materials
required for the work shall be supplied by the
16 16 Supply and fixing of outdoor 6U cabinet/rack Numbers 4.00 7852.00 31408.00
IP66 suitable for fixing switch/UPS etc . The
cabinet should be fixed in the out door pole.
necessary power adapter and all accessories
required for this work shall be supplied by the
contractor. Make : Rackom or similar.
17 17 Installation & fixing of earth electrode Numbers 4.00 3440.61 13762.44
assembly as per drg. No. CR/SK-753 including
earth wire connected through GI wire 8SWG
supported on M.S. flat of size 6mm x 40mm
to earth electrode for S&T equipment such as
lever frames, apparatus cases, signals, relay
racks, block instruments etc. as per RE
manual. The earth value should be
documented and painted on earth enclosure
made of concrete (only earth electrodes will
be supplied by Rly.) Contractor will bring
Earth enclosure and all other material
required for provision for earthing.
BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .