Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | L1 | Accepted-AOC The lowest tenderer | |
| 2 | L2₹20.4 L+₹1.6 L (8.38%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹24.6 L+₹5.8 L (30.6%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
23 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
REPAIR MAINT OF HT EQPTS AND ALLIED SERVICES AT SRIGANGANAGAR MIL STN
2023_MES_623906_2
CA NO CWE SGNR T-40 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
GE SRI GANGANAGAR
As per NIT
9 documents required · 9 mandatory
₹500
GE SRI GANGANAGAR
₹54,000
8 Feb 2024
4 Dec 2023
25 Dec 2023
4 Dec 2023
23 Dec 2023
11 Dec 2023
Amount
Supply & fixing in repair aluminium strip 25 x 3.15 mm thick fixed in ducts/on wall/in trenches/floor etc and jointing for interconnection of earthing fixed to equipment, test point including drilling holes and jointing with aluminium nuts, bolts and washers complete all as specified and directed by Engr-in-Charge.
M & L in repair for jointing and testing heat shrinkable, outdoor type, end termination cable jointing kit, suitable for 11KV under ground earthed system 3 core XLPE cable of size 50 to 95 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
M & L for jointing and testing heatshrinkable outdoor type, end termination cable jointing kit , suitable for 11KV under ground earthed system 3 core XLPE cable of size 120 to 185 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
M & L for jointing and testing heat shrinkable outdoor type, end termination cable jointing kit, suitable for 11KV under ground earthed system 3 core XLPE cable of size 240 to 300 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT/HT overhead lines conductors with hack saw/axe to clear the LT/HT line upto 3 metre on each side including disposal of trimmed branches 100 Metre away inside the station area & clearing site complete all as specified and directed by Engr-in-Charge. Note :- 3 metre width on each side (Horizontal/vertical) of LT/HT line shall be cleared.
Cleaning of tree branches/grass not exc 10 cm girth srounding the 2 pole/ 4 pole structrue HT/LT over head lines conductors with hack saw/axe to clear the LT/HT line upto 2 metre on each side including disposal of trimmed branches/grass 100 Metre away inside the station area & clearing site all as specified and directed by Engr-in-Charge. Note :- 2 metre width on each of LT/HT pole structrue. to maintaining of cleare area by using any type of pestisides are the responsibility of contractor. Clearing of Area is inspected by JE E/M .if found not cleared than penalty Rs 200/ per week.
M&L for opening the joints of HT/LT overhead conductor from the end of poles, stretching the overhead aluminum conductor with chain pulley and other T&P machineries, refixing the overhead conductor at the same place such that sagging of conductor is not more than 3% complete all as specified & directed by Engr-in-Charge. Note : Length of each OH conductor to be measured.
Supply and fix in repalacement pin insulator of size 150mm height, 150 mm dia polymer type tested with CPRI Lab, white, brown or green insulator suitable for 11 KV grade including one galvanized mild steel spindles two GI washer & one GI nut complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement disc insulators, vitreous porcelain /polymer type150 mm high and 150 mm dia ball and socket type, white, brown or green of two in series assembly for tension with tension clamps for conductor working pressure 11000 volts grade complete all as specified.
Supply, Installation, Testing and Commissioning of Chemical Earthing in replacement based on 3 meters long 50 mm dia EC Grade 'K' Copper earth pipe as a electrode 50mm bore duly fixed with connector at top for connection of copper strip 32 x 6mm riveted/nut bolt after 12 mm boring. The Electrode is surrounded by mixture of Teksai Electron 22 kg 1 bag & Ultra 10 Kg 1 bag Chemical compund powder including providing of pit cover heavy duty plastic of suitable size all as per manufacturer specification complete all as specified and directed.. Note: (i) Rate included for Testing commissioning including checking of earth continuity and earth result complete all as specified and as directed. (ii) Venders are bound to get earthing result less than 0.5 ohm. If the result of earthing not achieved less than 0.5 ohm by one earthing then another additional earthing will be provided by the contractor as bi-pot including interconnecting with copper strip of same configuration at no extra cost to achieve test result as specified and all as directed by Engr-in -charge. (iii) Rates for copper earth strip of size 32x6 mm up to 7.5 RM will deemed to be included in quoted rates. Copper earth strip beyond 7.50 Mtr shall be measured and paid Separately under relavent items.
M&L in replacement Copper strip of size 32x6mm buried in ground and connected one end to electrode terminal and other end to terminal box with suitable size of G nut, bolt & washers complete all as specified and directed.
Supplying and fix in replacement of air break gang operated switch, triple pole, 11 KV (outdoor type) mechanically operated, suitable for horizontal or vertical mounting fixed type complete with 12 insulators and steel frame, with operating mechanism worked from ground level with fixed contacts of phosphorous bronze and moving control of copper, for current rating upto 200 Amps including GI pipe heavy duty of required size and with locking arrangement including Godrej (Freedom) 50mm pad lock with two keys with fuse mounts, fuse carriers and HT fuse elements having 400 amp rating suitable for HT 11 KV, 50 Hz, AC supply including necessary electric connections, mild steel ISMC-75 of required length fixed with mild steel clamps made out of 50mm x 6 mm flat iron,nut,bolts and washers of required size for fixing GOD complete and painting structural steel surface with 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supplying and fix in replacement of air break gang operated switch, triple pole, 11 KV (outdoor type) mechanically operated, suitable for horizontal or vertical mounting fixed type complete with 12 insulators and steel frame, with operating mechanism worked from ground level with fixed contacts of phosphorous bronze and moving control of copper, for current rating upto 400 Amps including GI pipe heavy duty of required size and with locking arrangement including Godrej (Freedom) 50mm pad lock with two keys with fuse mounts, fuse carriers and HT fuse elements having 400 amp rating suitable for HT 11 KV, 50 Hz, AC supply including necessary electric connections, mild steel ISMC-75 of required length fixed with mild steel clamps made out of 50mm x 6 mm flat iron,nut,bolts and washers of required size for fixing GOD complete and painting structural steel surface with 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supplying and fix in replacement of air break gang operated switch, triple pole, 33 KV (outdoor type) mechanically operated, suitable for horizontal or vertical mounting fixed type complete with 12 insulators and steel frame, with operating mechanism worked from ground level with fixed contacts of phosphorous bronze and moving control of copper, for current rating upto 630 Amps including GI pipe heavy duty of required size and with locking arrangement including Godrej (Freedom) 65mm pad lock with two keys with fuse mounts, fuse carriers and HT fuse elements having 630 Amp rating suitable for HT 33 KV, 50 Hz, AC supply including necessary electric connections, mild steel ISMC-75 of required length fixed with mild steel clamps made out of 50mm x 6 mm flat iron,nut,bolts and washers of required size for fixing GOD complete and painting structural steel surface with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
S & F in replacement lightning arrester expulsion type conforming to IS-3070 Part-II 1989 as amended upto date suitable for 33 KV earth system having discharged current rating 5 KA high current impulse with stand 65 KA for OH 33 KV line including bracket clamps nuts, washers and connecting to earth as specified and directed by Engineer-in-Charge.
S & F in replacement lightning arrester expulsion type conforming to IS-3070 Part-II 1989 as amended upto date suitable for 11 KV earth system having discharged current rating 5 KA high current impulse with stand 65 KA for OH 11 KV line including bracket clamps nuts, washers and connecting to earth as specified and directed by Engineer-in-Charge.
S & F in replacement pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 152mm at top and 102mm x 289mm at bottom, class 10, complying with requirements of IS-1678-1998 errecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and white colour upto 1.5 metre height from top of PCC pedestal/coping of poles and writing/ numbering of poles with synthetic enamel paint Black in 80mm high letters over 150mm x 200mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note :- PCC for foundation, cross arms and earth work shall be measured and paid for separately. Volume of pole embeded in PCC shall be deducted for payment purpose.
Supplying and fixing in replacement cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed by Engr-in-Charge. Note :Exposed steel surface shall be treated with two coats of aluminium paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer. The quoted rate shall be deemed inclusive of the above provn.
Supply, laying, jointing testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 33 KV grade of cross-sectional area 240 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade of cross-sectional area 185 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade of cross-sectional area 95 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
M & L for sand cushioning with dry coarse sand to under ground cable below and around after laying the cable jently punning down complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
Supplying, jointing and testing in replacement cold shrinkable type, end termination cable jointing kit, outdoor type, suitable for 33KV under ground earthed system 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
Maintenance and complete overhauling of 11 KV VCB/RMU` rating upto 800 Amp suitable for repturing capacity 350 MVA and remote control switch including dismantling of operating mechanism parts, well cleaning with petrol & CRC-226 and replacing moving parts including suitable sleeves , filling up suitable Gas, all required suitable nut bolts required at site, reassembling of parts after well cleaning of complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs & PTs and spouts metal parts and making VCB/RMU perfect operating in manual and electric mode including all routine and preventive maintenance including 2 coat of synthetic enamel existing company make paint over a coat of red complete all as specified and directed by Engineer-in-Charge. Note : (i) Spare parts required for replacement obtained approved OEM suitable capacity shall be measured and paid separately under respective items (Srl No.27 to 58) of BOQ. (ii) Labour charges for replacement of spare parts and gas filling shall be inclusive in quoted rate.
Supply only Power Pack for DC supply of VCB 100 VA AC input 90 V -270V, DC Output 24 V with Battery 7AH . Make :- V Tech, V Guard or equivalent.
Supply only microprocessor based relay of IDMT relay including testing, setting of relay for proper tripping according to load all as specified and directed by Engineer-in-Charge. Make : CG14N of Crompton & Greaves or equivalent
Supply only terminal bushing assembly (spout bushing) 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only Tulip contact (isolating contact 630 A) 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only circuit spout RYB (bus bar insulators) 61mm for 11 KV VCB complete all as specified and directed by Engr-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only vaccum interpreter chamber for 11 KV VCB complete all as specified and directed by Engr-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only spring charging gear for 11 KV VCB complete all as specified and directed by Engr-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only operating gear mech 11 KV VCB complete all as specified and directed by Engr-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only trip shaft for 11 KV VCB complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only Tripping coil assembly 230 V AC for 11 KV complete all as specified and directed by Engr-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only Closing coil assembly 230 V AC for 11 KV complete all as specified and directed by Engr-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only trip roller for 11 KV VCB complete all as specified and directed by Engineer-in-Charge.
Supply only vaccum interupter bottles for 11 KV VCB complete all as specified and directed by Engr-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only Trip cross locking assembly for 11 KV VCB complete all as specified and directed by Engr-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only Auxiliary Contactor 11 KV VCB complete all as specified and directed by Engr-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only Auxiliary switch 4 pole for 11 KV VCB complete all as specified and directed by Engr-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only spring charging motor for 11 KV VCB complete all as specified and directed by Engr-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only handle for manual charging of Spring charging mechanism of VCBs consisting of gears grooves complete all as specified and directed by Engineer-in-Charge. Make : Crompton & Greaves or equivalent.
Supply only Digital PT 11 KV/110V AC -01 Set suitable for existing make and capacity all as specified and direceted by Engineer -in - Charge
Supply only Breaker to PT Panel-01 Set suitable for existing make and capacity all as specified and direceted by Engineer -in - Charge
Supply only Right angle bhoot-04 sets suitable for existing make and capacity all as specified and direceted by Engineer -in - Charge
Supply only Primary seconday injection-01 set suitable for existing make and capacity all as specified and direceted by Engineer -in - Charge
Supply only Bushing termination -01 set suitable for existing make and capacity all as specified and direceted by Engineer -in - Charge. .
Supply only Multifunctional meter -01 set suitable for existing make and capacity all as specified and direceted by Engineer -in - Charge.
Supply only Heating system -01 set suitable for existing make and capacity all as specified and direceted by Engineer -in - Charge.
Supply only Indication lamps -01 set suitable for existing make and capacity all as specified and direceted by Engineer -in - Charge.
Supply only Copper bus bar set suitable for existing make and capacity all as specified and direceted by Engineer -in - Charge.
Supply only Bushing set-01 suitable for existing make and capacity all as specified and direceted by Engineer -in - Charge.
Supply only Gas suitable for existing make and capacity all as specified and direceted by Engineer -in - Charge.
M&L for surface dressing not exceeding averaging 15cm deep in soft/ loose soil and getting out including cutting of grass roots, bushes if any and filling of lower portion with soil obtained from cutting or dressing complete all as specified and directed by Engineer-in-Charge. Note :- Disposal of gas roots, bushes and excess soil (if any) shall be as per directed Engineering-in-Charge.
M&L for graded gravel/coarse stone aggregate 40 mm nominal size spread and levelled in layers complete all as specified and directed by Engr-in-Charge.
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for poles, stays & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engr-in-charge
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engr-in-charge
Supply and fixing in replacement stay assembly complete with accessories as shown in electrical plate No 1 using stay rod 20 mm dia x 1.8 metre long, stay bow 14mm dia and stay plate 30 cm x 30 cm x 6 mm including stay wire 8 SWG x 7 strands, loop type insulator, stay clamps and painting to exposed surfaces of mild steel work with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately under respective item of BOQ.
Supply, fixing & stretching in replacement aluminium conductor steel, reinforced (ACSR) of any size fixed on HT/LT poles fixed on insulators and binding with & including binding wire 14 SWG complete all as specified and directed by Engineer-in-Charge. Note : The weight of binding wire shall be inclusive in quoted rate.
Supply & fix continuous earth wire/guard cradle hexagonal rectangular, fabricated out of 3.15 or 4mm dia galvanized steel wire including mild steel wire of 1.63mm dia complete all as specified. Note :- Clips, clamps & eye hooks shall be measured and paid for separately.
Supply and fix in replacement of GI pipe 100 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge.
Supply and fix in replacement of GI pipe 50 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge. Note for Srl Item No 66 & 67 : Excavation & earth work shall be measured and paid separately under respective item of this Schedule.
M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor complete all as specified and directed.
Supply and lay reinforced pre cast concrete cable cover class HV, type 1, flat size 300 x 180 mm x 40mm all as specified and directed.
Disconnecting and taking down old U/S burnt out fixed female contact from the existing position and suply and fix new female contact of hard drawn strips of air break switch 11000 Volts grade up to 400 Amp capacity out door type fixed with suitable size of nuts bolts and washetrs etc and applying petroleum jelly for smooth operation including testing complete all as directed. Make :- JAYSHREE/ VERSATEC/JSI
Disconnecting and taking down old U/S burnt out moving male contact from the existing position and supply and fix new moving male contact of hard drawn strip of air break switch 11000 Volts grade up to 400 Amps capacity out door type fixed with suitable size of nuts bolts and washers etc and applying pertoleum jelly for smooth operation including testing complete all as directed. Make :- JAYSHREE/VERSATEC/JSI
Disconnecting the electric supply and taking down the U/S HT jumpers of bus bar/two/four ple structure and out point and supply and fix new HT jumpers of any length with suitable size of ACSR conductor and lugs PGI clamps and testing complete all as specified and directed.
Cutting the burnt out portion of the HT 11 KV (earthed) grade underground XLPE cable of size 50 to 95 Sqmm 3 core, supply and jointing HT cable straight through joint (Heat shrinkable) 11kV grade of size 50 to 95 Sqmm 3 core including necessary cable and testing complete all as specified and directed.
Cutting the burnt out portion of the HT 11 KV (earthed) grade underground XLPE cable of size 120 to 185 Sqmm 3 core, supply and jointing HT cable straight through joint (Heat shrinkable) 11kV grade of size 120 to 185 Sqmm 3 core including testing complete all as specified and directed.
Supply and fixing in replaccement copper wire 12 core 2.5 sqmm cable for control cable of breaker to control relay panel
Supply and fixing in replacement copper wire 4 core 4 sqmm cable for control cable of breaker to control relay panel.
Disconecting electric supply and Comprehensive maint of existing outdoor type HT 33 KV SF6 breaker from housing and cleaning, rubbing and overhauling the mechanical parts and Servicing, checking, reconditioning, control wiring, Primary test, Secondary test, Transformer protection test at on load/no load at satisfactoriy level of Engr-in-Charge in all respects and commissioing after replacement of the following unserviceable/ damaged components and accessories all as specified and directed by Engr-in-Charge :- (a) Motor assembly unit -01 set (b) Magnesium (c) Closing tripping coil-01 set (d) Indoor control relay -01 set (e) DC 48V FCBC -01 set Note: Relevent T&P and testing equipments/tools and minor accessories are arranged by the contractor and included in the quoted rates.
M & L in repair for fabrication of gates of angle/pipes or any other section with gusset plates, rails, braces etc, complete, drilling for fixing of sheel sheeting to other covering etc to be prepared for hanging or sliding with and including either hooks hinges or steel hanging door fitting also fastening and fixing complete including painting with two coats of approved synthetic enamel paint over a coat of red oxide primer.
M & L in repair for chain link MS galvanised fancing of any size and type including lines wires, straining bolts and binding wires etc complete all as directed by Engr-in-charge. Note : Labour charges for fixing of MS round bar shall be inclusive of quotede rates.
M & L in repair for galvasied mild steel channel, angle section etc for post of chain link fencing including notching for wire etc confirming to Fe 290 ,gradeE-165 complete, embedded in PCC. Note : PCC shall be measured and paid seperately under respective items.
Supply only 10mm dia MS round bar for fixing of chain fencing with post complette including painting with two coats of approved colour over a coat of red oxide primer.as as specified and directed confirming to Fe 290, grade E-165 .
M & L in replacement for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nut of approved size for HT 25x20cm complete all as specified and directed by Engieer-in-Charge.
M & L in repair for anti-climbing device spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole.
M & Laying in replacement HT Rubber Mat 1meter x2meter x19 mm at the HT Installation.
Supply and replacement HT 11 KV Electric Rubber hand gloves for suitable operating HT equipment upto 11KV
Supply and replacement of HT 33 KV Electric Rubber hand gloves for suitable operating HT equipment upto 33 KV.
Supply only soft earth discharge rod 35 KV damping resistance 10 K Ohm, Pultrusion Fiber glass multicolour complete all as specified and directed by Engieer-in-Charge..
Akarsha Enterprises
SRI SAI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .