Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC | ₹13.6 L Quoted ₹14.1 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹14.4 L+₹32,500 (2.30%)Rejected-Finance | ₹14.4 L+₹32,500 (2.30%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹14.5 L+₹43,020 (3.05%)Rejected-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | ₹14.5 L+₹43,020 (3.05%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹16.5 L+₹2.3 L (16.6%)Rejected-Finance 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | ₹16.5 L+₹2.3 L (16.6%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹18.4 L+₹4.3 L (30.2%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹18.4 L+₹4.3 L (30.2%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
8 Jun 2022, 6:00 pmClosed
GE West Agra
Garrison Engineer West 62 Station road Agra cantt
REPAIR AND MAINTENANCE OF CENTRAL AC PLANT AT OFP, SIGNAL CENTER AND MH UNDER AGE E/M (W) OF GE (W)AGRA
2022_MES_522923_1
8012/892/E8
Open Tender
Civil Works
Item Rate
330 days
GE West Agra
please refer tender document
8 documents required · 8 mandatory
₹500
Garrison Engineer west Agra
₹40,000
Yes
25 Jul 2022
10 May 2022
11 Jun 2022
10 May 2022
8 Jun 2022
25 May 2022
Amount
Checking/ detecting and arresting/ rectifiying of the leakage by putting nitrogen and oxygen gas in central type AC system comprising of compressor, condenser unit, gas piping system and AHU complete cycle system having compressor's capacity 1x9.5 TR and material & labour for repairing the leakage if detected, vacuum & checking for vacuum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed.
Checking/ detecting and arresting/ rectifiying of the leakage by putting nitrogen and oxygen gas in central type AC system comprising of compressor, condenser unit, gas piping system and AHU complete cycle system having compressor's capacity 1x14 TR and material & labour for repairing the leakage if detected, vacuum & checking for vacuum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed.
Checking/ detecting and arresting/ rectifiying of the leakage by putting nitrogen and oxygen gas in central type AC system comprising of compressor, condenser unit, gas piping system and AHU complete cycle system having compressor's capacity 1x23 TR and material & labour for repairing the leakage if detected, vacuum & checking for vacuum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. Note for item No. 1 to 3:- Refrigerant gas (M-22) and compressor oil shall be measured and paid separately under respective item herein after.
M&L for dismantling electric motor, strip opening, taking out the old worn out/unserviceable winding wire and rewinding the electric motor/mono-block with superior quality copper winding wire of suitable size including insulating material (PVC insulation sleeve, tape, film paper, varnish, cotton) required and re-fixing in position and testing complete all as specified & directed of following capacities :- NOTE : Quoted rates includes loading / unloading, transporting from site to trade workshop and back after repair.
M&L for taking out the mono-block pump 5 HP shaft, remetalling, welding, turning and fixing new bush and sleeve and re-fixing in position complete all as specified and directed.
S&F in repair ball bearing double collar type complete all as specified and directed for following capacities of electric motor/mono block motor :-
S&F in repair refrigerant gas pressure gauge of suitable size with adopter flair work and brazing work of the following range complete all as specified and directed.
HP - 30 to 300 Lbs
LP - 30 to 150 Lbs
OP - 30 to 150 Lbs
S&F in repair dial type water pressure gauge 4'' dia of working pressure 5 Kg/Sqcm complete with adopter complete all as specified and directed.
S&F in repair HP/LP cut off switch including control valve & brass flare nuts and making electric connections complete for any capacity of AC plant complete all as specified and directed.
S&F in repair OP cut off switch including making electric connections complete for any capacity of AC plant complete all as specified and directed.
Taking out oil filter assembly by opening up all the bolts of side cover and replacing the unserviceable oil filter by new one, re-assembling the same and fixing in to its original position by tightening the all bolts & making the system leak proof including providing the side cover gasket for the following sizes :-
Repair of LT electric control panel board, cleaning inside with blower, servicing tightening all electrical connections/ contacts points, replacing defective locking clips thimble and making it serviceable with inter locking wiring including replacement of the defective parts and refixing back in its existing position complete all as specified and directed. Note : Defective parts will be measured and paid separately.
Supply only the following parts of panel board to be fixed under respective items here in above or before complete all as specified and directed:-
Electronics timers type ET-100, 110 V to 240 V, 50 Hz, 3 Sec to 10 Sec.
Electronics timers type ET-100, 110 V to 240 V, 50 Hz, 9 Sec to 30 Sec.
Contactor ML 1.5 Make :L&T
Contactor ML 2 Make: L&T
Contactor ML 3 Make: L&T
Power contactor ML 4 Make :L&T
Bimetallic over load relay ML type 9 to 14 Amps Make : L&T
Bimetallic over load relay ML type 20 to 32 Amps
Bimetallic over load relay ML type 28 to 48 Amps
Volt meter 0-500V make : AE (Digital type)
Ampere meter of any range Make : AE (Digital type) suitable LT up to 100 Amp
PVC insulated stranded single core copper cable conductor wire 1100 Volts grade of size 10 Sqmm
PVC insulated stranded single core copper cable conductor wire 1100 Volts grade of size 16 Sqmm
MCB TP 63 Amp,50 Hz,, 10 KA rupturing capacity, 240 volts (C-series) 10 KA.
MCB TP, 40 Amp,50 Hz, 10 KA rupturing capacity, 240 volts (C-series) 10 KA.
Connector 4 pole, 240 volts complete all as specified and directed.
S&F in repair strip heater 3 KW single phase complete all as specified & directed.
Dismantling air filter section any size of air handling unit and M&L for overhauling/servicing of AHU by cleaning the AHU complete, cooling coil with coil shine, by spraying the chemical on the fins of coil and let the chemical remains on the fins for 04 hours then clean the chemical with fresh water till the chemical flushes out entirely by pressure of water & wash completely including stoppage of air leakage by using gasket clothing and PGI sheet with nut , bolts and cleaning air handling room with bleaching powder solution/chemical/acid & cleaning of air filter wire mesh/5 micron filter with above solution complete all as specified and directed.
S&F in repair by replacement of fan belts of following size complete all as specified and directed :-
B-72 Compressor Motor 20HP
B-84 Compressor Motor 12.5 HP
B-96 Compressor Motor 30 HP
Repair to old existing safety release valve comprising for renewal of Teflon sheet and adjustment of valve for AC plant of any capacity complete all as specified and directed.
S & F in repairs three phase motor connector plate suitable for 3 HP to 5 HP complete all as specified and directed.
S & F in repairs three phase motor connector plate suitable for 12.5 HP to 30 HP complete all as specified and directed.
Supply and fix in repairs water spray header, suitable for 2 x 9.5 TR capacity AC plant and connected items etc. complete and necessary water pipe lines connection, commissioning and testing complete all as specified and directed.
Supply and fix in repairs water spray header, suitable for 2 x 14 TR capacity AC plant and connected items etc. complete and necessary water pipe lines connection, commissioning and testing complete all as specified and directed.
Supply and fix in repairs water spray header, suitable for 2 x 20 TR capacity AC plant and connected items etc. complete and necessary water pipe lines connection, commissioning and testing complete all as specified and directed.
Supply and fix in repairs water spray header, suitable for 2 x 23 TR capacity AC plant and connected items etc. complete and necessary water pipe lines connection, commissioning and testing complete all as specified and directed.
Supply and fix in repairs PVC fills of size 300x300x150 mm complete all as specified and directed.
S & F in repairs solenoid coil (for any size of solenoid valve or loader- unloader) and making necessary electric connection complete all as specified and directed
S&F in repairs thermostatic expansion valve flange type of size suitable for 3x9.5 TR (R-22) AC plant as per and making necessary connection complete all as specified and directed.
S&F in repairs thermostatic expansion valve flange type of size suitable for 3x14 TR (R-22) AC plant and making necessary connection complete all as specified and directed.
S&F in repairs thermostatic expansion valve flange type of size suitable for 3x23 TR (R-22) AC plant as per and making necessary connection complete all as specified and directed.
Supply and fixing PVC water protection cover / jali for protection from birds, leaf etc to cooling tower tank.
M & L for installing, commissioning & testing of the filter section consists of pre-filter should be made of 14 gauge stainless steel to remove 99.90% of dust, pollen, mold, bacteria and any airborne particles with a size 0.1 micrometer at 85 liters per minute, 90% efficiency complete all as specified and directed. The pre-filter having the following sizes :
S&F in repair GI steel tubing 'medium grade' on wall/floor including cutting, threading of required size suitable for connection to condenser, mono block pump, cooling tower, gate valve including all GI fittings complete all as specified and directed for the following bores:-
80 mm bore
40 mm bore
25 mm bore
S&F in repair gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified & directed:-
80 mm dia
40 mm dia
25 mm dia
S&F in repair cast iron non return valve of 80 mm bore with flanged end, ISI marked complete with jointing materials complete all as specified and directed.
Supply only refrigerant gas M-22 in cylinders of required capacity including transportation, loading and unloading charges for collection of empty cylinders from MES store yard of AGE E/M, returning the same cylinder or other cylinder after refilling and testing of cylinders including test certificate by authorised agencies complete all as specified and directed.
Supply only non freezing compressor oil in sealed standard sized containers complete all as specified and directed.
De-scaling the entire water circulation system including condenser but excluding mono block pump set from existing AC plants by circulating de scaling solution with the help of de -scaling pump circulating acid independently in each tube by gravity cleaning the condenser tubing with brush including renewal of worn out gasket, nuts and bolts complete all as specified and directed for following capacity AC Plants.-
3 x 23 TR AC Plant
3 x 20 TR AC Plant
3 x 14 TR AC Plant
3 x 9.5 TR AC Plant
Supply and fixed in repairs, air break (power) contactor 3 TF30 31-0A complete all as specified and directed.
Supply and fixed in repairs, air break (power) contactor 3 TF30 10-0A complete all as specified and directed.
Supply and fixed in repairs, HRC cartridge fuse 20A, (IS9224) complete all as specified and directed.
Supply and fixed in repairs, HRC cartridge fuse 63A, AC complete all as specified and directed.
S&F in repair, 25 mm dia gun metal stop valve with iron wheel head screwed both ends for iron pipe complete all as specified & directed.
S&F in repairs, 20mm dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipes or for unions complete all as specified and directed.
M&L for opening side cover of compressor by descrewing nuts, bolts etc and replacing shaft seals assy, refixing side cover with replacement of packing gaskets and leak testing and rectifying if found complete all as specified and directed of following capacity:-
Suitable for SMC 3-65 of Make- ACCEL
Suitable for SMC 4-65 of Make- ACCEL
Suitable for SMC 8-65 of Make- ACCEL
M& L for replacement of temperature gauge suitable for fixing on existing water line of AC plant of range 0 to 60 degree centigrade complete all as per existing sample including filling of oil in mounting pocket all as directed by Engr-in- Charge.
S&F in repairs water flow control switch suitable for fixing on chilled water type central AC plant condenser/chiller pipe line, suitable for max pressure 10 bar, model HFS-25, Make Synergy or equivalent as approved by GE complete all as specified and directed.
M/S J J ENTERPRISES
M/S SHARADA ASOCIATE
Gupta Automobiles
Flint India
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .