| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94.9 LAccepted-AOC 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹1.0 Cr+₹6.1 L (6.46%)Rejected-Finance NO 1C CHROMPET KANCHIPURAM TAMIL NADU 600044 INDIA | CHENGALPATTU | TAMIL NADU | 600044 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹1.0 Cr+₹7.1 L (7.50%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹1.0 Cr+₹8.0 L (8.38%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹1.0 Cr+₹8.0 L (8.38%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
21 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
CERTAIN SANCTIONED WORKS IN AFS SULUR
2020_MES_371603_1
8346/E8
Open Tender
Miscellaneous Works
Item Rate
240 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹1.8 L
Yes
9 Oct 2020
24 Aug 2020
22 Sept 2020
24 Aug 2020
21 Sept 2020
14 Sept 2020
24 Aug 2020 - 12 Sept 2020
60 days
Amount
SCHEDULE A BOQ
Supply , installation, testing and commissioning of 11 KV , 800 Amps, 25 kA for 3 sec HT Vaccum Circuit Breaker panel board outdoor type with 01 No incommer, 02 Nos outgoings all as specified and as directed for Main Receiving Station as per the below details :
(A) 11 kV, 800Amps, 25 kA for 3 sec HT Vaccum Circuit Breaker panel for incomer confirming to the IEC 62271 – 200, IAC – AFLR – 25kA for 1 sec, PM LSC – 2B, front accessed comprising of the following equipments :-
(a) 800 Amps continuous rating with Raychem sleeved Aluminum Bus Bar.
(b) Vaccum Circuit Breaker of ABB or equivalent in Siemens/BHEL/Schneider with end sheet, castle lock & rear extension.
(c) Motorised Spring charging mechanism.
(d) Cast resin current transformer, 11 kV, suitable for Incoming (3000 KVA) , 50 Amps/5 +1A, 10VA, CL 5P20 CI-1 – 03 Nos.
(e) Cast resin potential transformer, 11kV/√3/110V/√3, 15VA CL1.0 – 03 Nos with desired capacity PT fuses.
(g) Provn of space for installtion of reverse power protection relay (RPPR) of size 250mm x 200mm on VCB Panel at main receiving station.
(h) Multifunction meter with RS 485 Port for MODBUS Communication, equivalent in L&T/ Rishabh/ Elmeasure/ Secure.
(k) SCADA compatible IEC 61850 Numerical O/C & E/F relay type REF615 of Make ABB or equivalent in Siemens & Schneider having following additional features.
(i) Trip ckt supervision
(ii) Master trip
(iii) Arc flash supervision of circuit breaker, cable and bus bar compartment.
(l) Antipumping relay
Panel shall have following additional features
(i) Continous rated closing/tripping coils.
(ii) Integral spring charging handle.
(iii) Fully internal are tested (25 kA for 1 sec) as per latest IEC 62271 – 200 Norms.
(iv) Racking in/out, manual closing/tripping of the CB with compartment door closed.
(l) Breaker shall be provided with following features
(i) Auxiliary switch with 6 No + 6 NC contacts, mounted on the draw out portion of the switchgear.
(ii) Position/cell switch with 3 No + 1 NC contacts, one each for TEST and SERVICE position.
(iii) Auxiliary switch, with 4 NO + 4 NC contacts, mounted on the stationary portion of the operated mechanically by a sliding lever from the breaker in service position.
(B) 11 kV, 630Amps, 25 kA for 3 sec HT Vaccum Circuit Breaker panel for Outgoing- 02 Nos confirming to the IEC 62271 – 200, IAC – AFLR – 25kA for 1 sec, PM LSC – 2B, front accessed comprising of the following equipment :-
(m) 800 Amps continuous rating Aluminum bus bar. Busbars and droppers shall be Raychem insulated.
(n) Vaccum Circuit Breaker of ABB or equivalent in Siemens/BHEL/Schneider with end sheet, castle lock & rear extension.
(o) Motorised Spring charging mechanism.
(p) Cast resin current transformer, 11 kV, suitable for outgoings ( 2000 KVA -01 No , 1000 KVA -01 No) 50 Amps/5 +1A, 10VA, CL 5P20 CI-1 – 03 Nos for Each outgoing .
(r) Multifunction meter with RS 485 Port for MODBUS Communication, equivalent in L&T/ Rishabh/ Elmeasure/ Secure.
(t) SCADA compatible IEC 61850 Numerical O/C & E/F relay type REF615 of Make ABB or equivalent in Siemens & Schneider having following additional features.
(i) Trip ckt supervision
(ii) Master trip
(iii) Arc flash supervision of circuit breaker, cable and bus bar compartment.
(u) Antipumping relay
Panel shall have following additional features
(i) Continous rated closing/tripping coils.
(ii) Integral spring charging handle.
(iii) Fully internal are tested (25 kA for 1 sec) as per latest IEC 62271 – 200 Norms.
(iv) Racking in/out, manual closing/tripping of the CB with compartment door closed.
(v) Breaker shall be provided with following features
(vi) Auxiliary switch with 6 No + 6 NC contacts, mounted on the draw out portion of the switchgear.
(vii) Position/cell switch with 3 No + 1 NC contacts, one each for TEST and SERVICE position.
(viii) Auxiliary switch, with 4 NO + 4 NC contacts, mounted on the stationary portion of the operated mechanically by a sliding lever from the breaker in service position.
(d) Interpanel barrier to prevent arc propagation from one panel/compartment to other.
(e) Earthing switch rated for full making capacity with provision for safe & reliable position indicator.
The quoted rate shall be inclusive of PCC bedding/foundation etc required for installation of the Panel on ground as per manufacturers recommendation.
Supply, Installation, testing, and commissioning of 11KV Extensible Ring-Main-Unit, Outdoor type with IP65 or higher Fabrication (ensuring outdoor protection to complete RMU, including cable-boxes), SF6 gas insulated compact switchgear, comprising arrangement of 02 load break switches for incoming with suitable mechanical interlocking between two incomers and 01 VCB for outgoing, all of rating 630Amp, and Bus PT Module, cable termination from front, having short-circuit withstand capacity of 20KA/3sec, permanently enclosed in a tank made by sealing non-magnetic / non-ferritic stainless steel sheets, to provide IP67 Degree of Protection to live parts and Internal Arc protection (IAC 20kA/1-sec for tank), duly filled with SF6 gas with leakage rate less than 0.1% and partial discharge tested as per IEC 62271-200, complete with all aceesories as described below and coupling busbars for bus-coupling of two RMUs where necessary, to meet the desired configuration. The earthing busbar should be of aluminium and provided in each cable box & through out the length of the switchgear. (Make: SCHNEIDER / ABB / SIEMENS).
(a) Each Load Break Switch module shall comprise of: (i) Manual operated, 11kV, three position load break switch with snap-action knife blade mechanism, suitable to break upto 630amp of rated current, along with associated earthing switch of making capacity. (ii) True position mechanical indication of switch position ON, OFF and EARTH on the front facia of the panel (iii) “Live Cable “Indicating LEDs energized through Capacitive Voltage Dividers shall be permanently available on the front facia, without requiring any external instrumentation. Whereas the cable bushings shall be enclosed inside hinged door cable-box interlocked with respective Earthing switches. (iv) Right Angle terminal protector boots for covering the cable termination.
(b) Each Vacuum Circuit Breaker Unit Module shall comprise of: (i) Manual operated, fixed-type 11kV Vacuum circuit breaker suitable for breaking short circuit current upto 20kA having two position double spring charging mechanism. (ii) In-series, Three position disconnector/earthing switch on downstream side of vacuum circuit-breaker (iii) Mechanically latched ON/OFF Push Buttons along with True position mechanical indication of Vacuum Circuit Breaker position (ON/OFF) and Disconnector position (ON/OFF/EARTH) shall be available on the front facia of the panel (iv) “Live Cable “Indicating LEDs energized through Capacitive Voltage Dividers shall be permanently available on the front facia, without requiring any external instrumentation. Whereas the cable bushings shall be enclosed inside hinged door cable-box interlocked with respective Earthing switches. (v) Right Angle terminal protector boots for covering the cable termination. (vi) Integrated 3 O/C + 1 E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also Relay shall record minimum 5 fault records with time stamping. (vii) Set of 03 Nos Ring Core Epoxy-cast Protection CTs having suitable ratio, 2.5VA, 5P10 directly mounted on trifurcated but sleeved portion of cable terminated.
Note for item No 2 & 54 : (a) The quoted unit rates deemed to be inclusive of the following:-
(b) The tenderer is advised to visit the site before quoting the tender.
(c) The cost of electrical and mechanical interlocking between VCBs as per site conditions shall be deemed to be included in the quoted rate.
(d) Anything missing out in sch 'A' but technically required for efficent working of VCB and RMU are to be included in the quoted rate.
(e) The quoted rate shall be inclusive of PCC bedding/foundation etc required for installation of the Panel on ground as per manufacturers recommendation.
(f) Drawings of VCB & RMU have to be approved by the accepting officer and on accord of approval only, the contractor has to place the order
(g) All other makes of components pertains to VCB & RMU not specified in the CA to be provided only reputed make as recommended by the OEM only
(h) Pre - commissioning test shall be carried out by the SEI/EI before issue of completion of the work
(j) The rate quoted inclusive of taking out the connection from the existing system wherever applicable and connecting incoming and outgoing HT cable with RMU. However, Cable End termination joints will be measured and paid separately under relevant item of the Schedule.
(k) The contractor will intimate th date of testing of equipments at site before installations. Copies of all documents of routine and type of test certificate of the equipments shall be furnished to Engineer-in-Charge.
Disconnecting HT cable connections from the existing Indoor VCB Panel and taking out HT Cable from indoor sub station, reconnecting the same HT Cable to another existing VCB /RMU located out side of same Sub staion complete all as specified and directed by Engineer-in -charge.
Note :- The unit rate is deemed to be included for :- (a) Excavation for taking down existing cable, shifting of cable as directed by the Engineer-in-Charge and relaying cable in other location. (b) Disposal and return filling (c) Sand cushioning and PCC cover measured separatley
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified.
Returning, filling in, trenches including spreading leveling, watering and well ramming in layers not exc 25 cm.
Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point.
Supply and Laying Riddling Sand (obtained from excavation for taking down cable) for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Dry M-Sand free from fine particles laid to required width of trenche at bottom and top for cable cushioning all as directed. Note : Punned thickness only measured and paid.
Un-reinforced precast concrete cable cover class HV Type 1, flat size 300mm x 180 mm x 40 mm thick.
Supply and laying in trenches/through pipes or bare in road crossings/paths/ drains/ ducts/ floors/along poles/equipments etc. Cable Under ground, cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables with aluminium conductor, earthed,11 KV grade, of cross sectional area 185 Sqmm x 3 core laid all as specified and directed. Make : RPG Asian, Havells, Polycab
Cutting existing road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note :- The unit rate is deemed to be included for the following :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 as in any type of road
Supply only 100 mm bore of pipe high density polyethylene pipes (HDPE) of pressure rating 6 kgf/ cm2 laid in trenches for cable protection passing under road/ floor or for fixing to poles complete all as specified and directed. Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
Out door cable straight through jointing kit (Heat shrinkable) suitable for XLPE under ground aluminium conductor cable, 11 KV (Earthed) grade, of cross sectional area 185 Sqmm 3 core. Make : - Raychem, Denson, M-seal
S&F cable route indicator made of 15cm x 15cm x 6mm thick MS plate welded with 10mm x 30cm long MS rod grouted in PCC block of size 0.2 x 0.2 x 0.3 m and writing HT cable complete all as directed.
Disconnecting incoming/outgoing cable connections of the existing Ring main Unit and taking down complete with all accessories from the foundation and shifting same to the out door location with in the distance of 2 KM and re-install, testing and commissioning of RMU including cable connections with suitable PCC (1:3:6 type C1) foundation up to 45 cm above ground level, complete all as specified and directed.
Boring of hole under road/ hard standing by trenchless technology including S&F HDPE pipe "heavy duty" of size 100mm bore fixed in repairs complete all as specified and directed
M&L for Cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm. Make : - Raychem, Denson, M-seal
Supply and fixing Low Voltage Surge Protector 1P+N, (12.5 KA per pole) 25 KA . Make: Legrand Cat No. 412276 or equivalent in Schenider, ABB.
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two run 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note: (a) 4 runs of 6 sqmm cable along with two run of 6 sqmm cable for earth conductor and PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size of brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F factory made powder coated distribution board SP & N 4 way single door, including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand
S&F metal clad switch socket triple pole and earth encolsure with three pin and earth plug with socket complete with on triple pole 32 Amps, 415 Volts MCB.Make :- Legrand /Siemens/ Schnieder.
S&F Factory made powder coated distribution board TPN, 6 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete and conforming to IS: 8623 all as specified. Make/Model : Siemens or equivalent of Schnieder & Legrand
S&F Triple pole Neutral MCB 63 Amp , 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408683 or equivalent of Schnieder (Multi -9)/ L&T (Hegar).
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25 x 6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, magnesium sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion complete all as per specified and as directed by Engineer-in-Charge.
Note :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) The rate of earthing strip upto 7.5 mtrs shall be included in the quoted rate and beyond 7.5 mtrs shall be measured and paid separately.
(c) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(d) Earth resistance tester should be calibrated from authorised company/ lab.
(e) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Galvanised Earth strip of size 25 x 6 mm fixed on proper post insulator at the instrument end.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: (a) 4 runs of 4 sqmm cable along with two run of 4 sqmm cable for earth conductor and PVC casing capping shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Inverter split unit Indoor/ outdoor complete with smart inverter full HD filter, bio sleep smart server, turbo cooling, twin BLDC compressor, wide air flow blade, antibacterial coating, dehumidification, auto clean quiet mode, auto restart 24 hours timer, auto cooling fan mode, 4 step fan speed, of capacity 1.5 TR, operating on 230 Volt single phase AC supply, with cordless remote control unit and Filter Configuration with, Catechin, Silver Ion, Anti Bacterial/ Anti Acarine/ Active Carbon/ Vitamin C/ Dust Filter complete including installation all as specified and directed. Make: Sumsung cat part No AR18MV5NEWK or eqvt Cat Part No KS-Q18ENZA in LG or HITACHI
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capaciy 4 KVA. Make - V-Guard Model No VG 500 or equivalent in Microtek/ AE
Replacement IP 65 polycarbonate MCCB distribution board of size 200 x 280 x 130 mm with inbuilt hinges, four pole, 125 amp breaking capacity 16 KA MCCB conforming to IEC-61439-1 complete with IP 65 polycarbonate window for easy operation of MCCB. The polycarbonate enclosure should be dust, water and all weather proof for outside mounting, flame retardant UL 94VO, UV resistant, glow wire test 960°, impact IK 08, Halogen free and ROHs complaint,, conforming to IEC 60529, complete all as specified. Make :- L&T/ Schneider/ Hensel/ Grasp Note :- The contractor shall submit test report from the manufacturer to comply with all requirements and specifications given in the contract.
Supply erection, testing & commissioning of High galvanized mast light 15 mtr height suitable for 6 to 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of grade 304 or 316, 6 mm dia 7/19 guage and double drum winch with luminaire mounting arm, pully assembly, LED type singlr, aviation obstruction light, lightning arrester spike including earth work and RCC foundation as directed by manufacturer/ Engineer-in-Charge. Make : Bajaj/ Havells/ Crompton
Note :- (a) Foundation and Supporting accessories of high mast shall be suitable to withstand min 50 KM per hr wind speed.
(b) Winches shall be completely self sustaining without the need of any break/ spring/ clutch, self lubricating by means of oil bath, grooved drums for tidy and smooth rope lay.
Supply and fabrication by using standard mild steel sections like angle iron / flat iron /nut bolts etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable for fixing flood lights at existing poles/structures complete all as specified and directed by Engr in charge.
Supply and fixing Low Voltage Surge Protector 3P, (37.5 KA per pole) 37.5 KA . Make: Legrand Cat No. 412272 or equivalent in Schenider, ABB.
Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and PVC casing capping shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size of brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F factory made powder coated distribution board SP & N 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete and conforming to IS: 8623 all as specified. Make/Model : Legrand/ Siemens/ Schnieder
S&F MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408617 or equivalent of Schnieder, Siemens.
Metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Make : Cat Pt No 607841 of Legrand or equivalent of Schnieder (Multi -9)/ L&T (Hegar).
Supply and fixing in replacement of unserviceable energy efficeint Ceiling fan 1200mm sweep, energy efficient ISI mark with 5 star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No 2 cm height with synthetic enamel paint all as specified and as directed. Make : Havells cat Part No. ES Neo or equivalent in Bajaj/ Orient. Note:- (a) The contractor shall given a written guarantee of minimum two years from completion of work. (b) Old Unserviceable ceiling fan shall be deposited to MES store yard.
Domestic Exhaust Fans for kitchen, 300 mm sweep, 230 volt suqare type, heavy duty, 1400 RPM, corrosion less mild steel body of motor, plastic / fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, including necessary cutting, making holes on stone/brick walls, fixing arrangement with MS pipe 350 mm dia of required length for protect deshape of stone masonery, suitable hold fast with necessary nut, bolts / screws including taking down existing one, writing MES No 2 cm height with synthetic enamel paint all specified and directed. Make- havells model -Ventil Air - DB or equivalent in bajaj, Almonard. Note:- Old Unserviceable exhaust fan shall be deposited to MES store yard
Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No :408587 to 408595 / Siemens/ Schnieder.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 sq mm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Supply and lay fly ash bricks for cable protection
Supply and fix in replacement pole/ wall LED Flood Light luminaire of capacity 160 Watt,system lumen efficacy not less than 90 lumen per watt, total system lumens not less than 16000 lumens, PF>0.90 ,CRI not less than 70, THD not more than 10 %, surge protection not less than 5 KV, colour temp 5700 k to 6500k, operating voltage ranging from 120V to 270 V at 50 Hz AC frequency,Pressure die cast aluminium housing in powder coated finish , heat resistant toughened glass , gasket etc ,luminaire IP 65 Class -I all as specified and directedMake : Bajaj Cat No. 169642 BARFEG 160W LED or Equivalent of Philips Cat Part No : BVP 410 LED 172 CW HE MB FG S3 XT/ wipro.
Notes:- (a) LED chip make shall be Nichia, Osram, Cree, Lumilid. (b) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (c) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (d) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 185 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Havells/ NICCO
Material and labour, earthing complete with copper earth plate electrode of size 600mm x 600x 3.15 mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level),with top edge of earth plate not less than 1.5m below normal ground level, eart plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, magnesium sulphate (1 : 1 : .5), electrode connections using copper strip of size 20 x 3 mm thick (upto body of equipment) by means of brazing / welding conencted to main switch board or main control board or test point, protected by galvanised iron pipe light grade 40mm dia bore nd watering pipe 20mm dia bore GI medium grade with funnel and wire mesh including all neesary(excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in elctrical plate No 3 of MES schedule Part-I (2009), testing on completion, complete all as specified and directed.
Notes:- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80 mm thick reinforced with XPM not less than 4Kg/ Sqm.
(ii) The rate of earthing strip upto 7.5 mtrs shall be included in the quoted rate and beyond 7.5 mtrs shall be measured and paid separately.
(iii) PCC pit cover shall be constructed 500mm away from the edge of eath pit.
(iv) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m lenth required at site shall be measured and paid sepaarately.
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.
(vi) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vii) Earth resistance should be less than 3 Ohm, In case the test results are not found below 3 Ohm, complete earthing will redone without any extra cost to Govt.
Supply and fix in repalcement of unserviceable Water heater with Water heater storage type, vertical, electric single phase 240V,2 KW,capacity 25 litres,BEE 5 star rated including taking down existing one. Havells Model No Monza DX Cat part No GHWAMGTWH025 White colour or Recold, Bajaj. Note:- (a) The contractor shall given a written guarantee of minimum two years from completion of work. (b) Old Unserviceable storage water heater shall be deposited to MES store yard.
PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete including taking down existing one all as specified and as directed.
Pedestal fan complete accessories 230 V,400 mm sweep. BEE 5 star rated including taking down existing one all as directed. Havells Model No Wind Strom or Bajaj/ CG Note:- Old Unserviceable pedestal fan deposited to MES store yard
PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Polycab
Point wiring complete with 4 sqmm copper multi stranded unsheathed 1100 volts gradeFRLS cable drawn through and incl PVC Casing capping with accessories in wall/roof/ceiling/hangar steel frames etc incl MS Modular terminal boxes, concealed/fixed surface to walls covered with modular plates with cover etc and 4 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor controlled by one 15A switch socket independently & connecting to common earth dolly completeall as specified and as directed. Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, cover plate etc will be measured and paid for separetely. (b) Connection of wire with switch, socket shall be through copper thumble (lups) only.
Modular switch 1 way 16 Amps, 1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Modular socket outlet multipurpose 2/3 pin 6/16 amps, 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Modular white cover plate with frame, 3 Module.
Metal flush box 3 module.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 8-10 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation. Make : Model HTSP 3I7 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( The rate of earthing strip up to 7.5 Mtrs is included in the quoted rate).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including dry or rocky soil.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xviii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xix) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete including taking down all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Epoxy base insulators of suitable size 40mm height for fixing copper/ GI earth strip on wall/ceiling/floor/poles etc all as specified. NOTE : Quoted Unit Rate deemed to be included for drilling holes per Metre as specified on GI/Aluminium/Copper Strip of any type and size.
M&L for replacement of old unserviceable BER 12V, 100AH SMF batteries with SMF Batteries of same capacity for the existing 3 phase 50KVA Online UPS. Make of Battery : Exide of Model No. Power Safe Plus or equivalent in Amar Raja (Power Zone)/ Amaron Note :- Old unserviceable batteries shall be deposited to MES store yard.
Feeder protection relay HIGH-END MULTIFUNCTION DEMAND CONTROLLER FOR COMPREHENSIVE ENERGY MANAGEMENT! With following features High / Low recording VLL, VLN, A, Hz, W, VA, PF, VAR value storage with time stamp. Accuracy class 1.0 as per IEC 62053-21, 0.5s option, Class 0.2s User programmable Password Protection. Measures THD and Individual harmonics up to 63rd order with a sampling rate of 512 samples / cycle. Captures and measures power quality events: K factor, Crest factor, Sag / Swell, Interruption and Unbalance in accordance with EN 50160. Display basic, power, energy, demand for both import and export parameters. Representation of waveforms for instantaneous V, I, Sag / Swell. voltage and current harmonics histogram. Records events such as Sag / Swell for voltage with the time stamp in 1s duration CO2, ON Hr, Power Interruptions, Max demand 4 high / 4 low, Flash 6MB, 12am snapshot, 31st day snapshot, Simultaneous sampling of voltage and current, programmable PT & CT ratio, Demand update every second to forecast kVA, kW & kVAR accurately, Clearance and Creepage distance meets UL- 61010. Programmable starting current in % of 5A secondary. Default 10mA Programmable Auto scrolling time - 1 sec. to 10 sec. (Default 5 sec.), Programmable Energy display - Counter based or Resolution based, Energy resetting at 9999999 kVAh x MF, Front LED pulse 16000 imp/kWh., OLD register to store previously cleared Energy & Load hours, Ampere hour (Ah) & PF average parameter. Phase wise Voltage Sag & Swell Wave Forms. LCD 8 parameter display at a time, 8 Digits energy. Power save mode with Enable/Disable option. Available RS485 communication & optional Ethernet communication (factory configurable). Byte order option - Field Programmable Float / Little Endian / Big Endian data format. Also equipped with Digital outputs - 4 potential free contacts with programmable time delay. Hysteresis of 1%. Trip time delay: 1 to 180 sec. Pulse output 300/TR/KWh. Analog Input up to 2. Accuracy of class 1% FS. Individual Harmonics up to 63rd order. Demand Controller with 4 Relay outputs. TOD option (Energy & Demand up to 8 slots). Digital Input up to 4 RTC synchronisation through communication. Analog Output - Two independently programmable to 0-20 mA (or) 4-20 mA Up to 60A or 100A direct measurement. Output configurable to any of the parameters from VLL, A, F, W, PF, VA. Make : C&S/ ABB/ Siemens
LAKSHMI ELECTRICAL ENTERPRISES
SUPER COOL
devan enterprises
KUMAR AGENCIES
Lucky Enterprises
M/S SRI BALAJI ENTERPRISES
K T ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .