Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹46.9 L+₹4.1 L (9.54%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹47.1 L+₹4.3 L (10.0%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹47.2 L+₹4.4 L (10.2%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹47.7 L+₹4.9 L (11.5%)Rejected-Finance OPPOSITE GATE NO 2 NORTH BENGAL UNIVERSITY PO N B U DIST DARJEELING WB | DARJEELING | DARJEELING | WEST BENGAL | 734013 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
14 Nov 2022, 6:00 pmClosed
GE BENGDUBI
Bengdubi Military Station, PO-Bengdubi, Dist-Darjeeling, Pin 734424
REPAIR REPLACEMENT OF OLD UNSERVICEABLE STREET LIGHTS AND OTHER ALLIED WORKS AT VARIOUS LOCATION UNDER AGE EM OF GE BEGNDUBI MIL STN
2022_MES_559623_1
8396/E8
Open Tender
Civil Works
Item Rate
180 days
GE BENGDUBI
MES contractor and category b(i) i.e. Low Tension Electric Works (upto 1100 Volts)
8 documents required · 8 mandatory
₹500
GE BENGDUBI
₹90,000
Yes
1 Dec 2022
22 Oct 2022
16 Nov 2022
22 Oct 2022
14 Nov 2022
7 Nov 2022
25 Oct 2022 - 29 Oct 2022
Amount
SCHEDULE 'A'
Excavation of trenches in soft/loose soil n.exc 1.5 metre wide and n.exc 1.5 metre depth and getting out complete all as specified and directed.
Returning filling in approved earth, including spreading leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed
Removing of excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed.
Taking out old U/S underground LT cable of any size, any position from trenches, floors and walls, complete all as specified and directed.
Supply, laying,testing and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade with fixing acessories of 6 Sqmm, 2 Core complete all as specified and directed.
All as per item No. 6 here-in-before but size of cable 10 sqmm, 2 core
All as per item No. 6 here-in-before but size of cable 16 sqmm, 2 core
All as per item No. 6 here-in-before but size of cable 16 sqmm, 4 core
All as per item No. 6 here-in-before but size of cable 25 sqmm, 3.5 core
All as per item No. 6 here-in-before but size of cable 35 sqmm, 3.5 core
All as per item No. 6 here-in-before but size of cable 50 sqmm, 3.5 core
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated ( punned) upto 180mm thickness complete all as specified and as directed.
M&L for horizontal boring under the road below 1 mtr from the road surface and dia of hole not exc 100 mm without damaging the existing road getting out and disposal of soil to a distance not exceeding 50 m from the site of work complete all as specified and as directed.
S&F in repair of GI pipe 50 mm light grade including all necessary fittings to poles/laid under road through boring for protection of under ground cable including making good the disturb surfaces complete all as specified and directed.
S&F in repair of GI pipe 40 mm light grade including fittings to poles/laid under road through boring for protection of under ground cable including making good the disturb surfaces complete all as specified and directed.
Supply & laying Sub-Class old size B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion for UG cable protection complete all as specified and directed.
Relaying only old serviceable brick as in cable protection retrived from taking out of cable complete all as specified and directed.
Relaying of serviceable cable after detecting the fault and making straigth through jointing kit of LT 440 volt under ground system of LT feeder/location of size 6 Sqmm 2 core to 16 Sqmm 2core complete all as specified and directed.
Relaying of serviceable cable after detecting the fault and making straigth through jointing kit of LT 440 volt under ground system of LT feeder/location of size 10 Sqmm 4 core to 95Sqmm 3.5core complete all as specified and directed.
S&F in repair/replacement of energy saving, environmental friendly, long life, pressure die-cast aluminium housing with toughened glass with IP66 protection street light with high power LEDs as light source connecting and testing LED street lights of 90 watts capacity complete all as specified and directed.
All as per item No. 20 here-in -before but of 60 W capacity LED Street light
All as per item No. 20 here-in -before but of 45 W capacity LED Street light
All as per item No. 20 here-in -before but of 25W capacity LED Street light
Supply and fixing in repair/replace of energy saving, environmental friendly, long life, pressure die-cast aluminium housing with IP66 protection flood light with high power LEDs as light source connecting and testing LED flood lights of 200 watts capacity complete all as specified and directed by the Engr-in-charge. Make : Make : Orient/Indiabulls/Havells/Crompton
All as per item No. 17 above but of 120 W capacity LED Flood light
All as per item No. 17 above but of 100 W capacity LED Flood light
All as per item No. 17 above but of 50 W capacity LED Flood light
M&L for 3 core cable 1.5 sqmm FRLSH PVC insulated copper conductor weather proof in existing surface/ recessed/on pole complete all as specified and directed.
M&L for PVC conduit pipe medium grade 20mm dia (ISI Marked) including necessary clamps, nuts, bolts etc. as required complete all as specified and directed.
S&F in repair street light bracket made out of GI tubing 32 mm bore medium grade 1.50 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 50mm x 6mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make: Tata/Jindal/BST
All items as per Ser No 30 here-in-before but 25 mm bore
Cutting and trimming of tree branches, bushes n.exc 5 Mtr girth all along HT/LT overhead lines/guard wire and removing branches out of defence land complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron earth lead wire 4.00 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel, GI earth wire protected by 15mm bore light grade GI pipe and other end connected to earthing test point or main switch board as directed including funnel with watering pipe of 20mm bore light grade GI, wire mesh, charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode PCC (1:3:6) type C-1 earth pit, cast iron cover and frame, including necessary excavation and earth work and refilling of black soil good conductor of earth and necessary testing complete all as specified and directed and shown on electrical plate No 3 of MES Schedule Part I
M&L for preparation of old rusted steel surface of LT steel tubular swaged pole (of any length upto 9 mtr) and applying one coat of black synthetic enamel paint upto 1.2 mtr height as per the existing pattern above the PCC coping and one coat of aluminium paint beyond 1.2 mtr height (for the rest portion) including cross arms brackets and re-writing pole numbers and and cutting vegetation growth all around the pole upto 1 mtr radius complete including replacement of self adhesive fluorescent colour tape as per existing pattern and size complete all as specified and directed
M&L for preparation of surfaces by scrapping of PCC poles of any length and applying two coats of weather coat paint black in colour upto 1.2 mtr height as per the existing pattern above the PCC coping and applying two coats of weather coat paint crimson colour includng applying alluminium paint to cross arms brackets and re-writing pole numbers and cutting vegetation growth all around the pole upto 1 mtr radius complete including replacement of self adhesive florescent copor tape as per existing pattern and size complete all as specified and directed
S&F MCCB 125 Amps, 4 pole,415 Volt adjustable type with breaking capacity 16 KA, and 100 % Icu including spreader terminals and connected acessories complete all as specified and directed.Make: Legrand/L&T/Havells/HPL
S&F MCCB 100 Amps, 4 pole,415 Volt adjustable type with breaking capacity 16 KA, and 100 % Icu including spreader terminals and connected acessories complete all as specified and directed.Make: Legrand/L&T/Havells/HPL
S&F MCCB 63 Amps, 4 pole,415 Volt adjustable type with breaking capacity 16 KA,and 100 % Icu including spreader terminals and connected acessories complete all as specified and directed.Make: Legrand/L&T/Havells/HPL
S&F 1100 volts grade heavy duty cable 4.0 sqmm PVC insulated stranded aluminum conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia suspension wire one twin core cable flat or circular type including taking out unserviceable one complete all as specified and directed.
All items as per Ser No 39 here-in-before but 6 Sqmm
All items as per Ser No 39 here-in-before but 10 Sqmm
M&L for surface dressing averaging 15cm depth in soft/loose soil for cleaning and cutting /removal of green vegetation in and around the installations and removal of the soil outside of the installation including spreading thin layer of anti vegetation chemical to prevent abnormal growth of grass/bushes complete all as specified and directed.
S&F in replacement of junction box made of thermoplastic, IP 66 of size 205mm x 255mm x 112mm consisting of 4 Nos terminal on porceline support inside enclosure,5 way insulated fo cable glands (incl locknut) with MCB SP 6 Amps and using 40 x 6mm size MS clamps of required shape & size with bolts, nuts & washers and making connection by providing suitable size of lugs / binding and testing directed complete all as specified and directed. Make : Hensel /C&S/BCH
Labour only for finding fault in ACSR Conductor including jumpper/wire in street light feeder and remove the carbon in jumper or Street light service wire complete all as specified and directed.
M&L for taking out the loop of any size of cable and checking the cable thoroughtly including cleaning and taking out defective porting including excavation earth work and making connection by providing suitable size of lugs/binding and testing and reconnect the cable to the electrical equipment complete all as specified and directed.
M&L for lowering of high mast carriage carefully from 20 mtr high structure for repairing light luminaries and raising latern carriage after repairing the light luminarises and adjust to its proper postion serving to winch mechanism pulleys steel wire ropes end terminal of SWR and greasing drain gearbox oil and toping up complete all as specified and directed.
S&F in repair Digital timer switch , surface mounting complete all as specified and directed.
S&F analog timer 20 Amps rating for automatic operation of street light complete all as specified and directed
S&F in repair contactor modular type with ON/OFF indicator and label holder 4 pole 230 V 40-63 Amps coil operating voltage 230 volt complete all as specified and directed.
S&F in repair contactor modular type with ON/OFF indicator and label holder 3 pole 230 V 40-63 Amps coil operating voltage 230 volt complete all as specified and directed.
S&F of automatic street Light switch using Astronomical/infrared senser based nature switch for automatic switching of street light. Panel of following Configuration shall be as under:- Phase:3,Max Load 6 kw,Astronomical timer,Contactor: 32 Amps TP, MCB Rating: 40 Amp TPN complete shall be enclosed in pole/wall mountable enclosure made of rust proof electric shock proof, terrmite proof and FR gradeSMCbox/CRCA sheet 2mm thik conforming to IP 54 complete all as specified and directed. Make: Havells/L&T/C&S/HPL or CPRI approved.
Stretching / restringing only ACSR conductor in position on LT over head lines of any size,type, span length with permisiable span sag and binding with pin/shackle insulator with new aluminum binding wire not less than 2mm dia complete all as specified and directed.
Servicing and maintance of Solar water heater plant of Cap 100/150/200/300 ltrs installed at single/duoble/triple story bldgs for carrying out minor leakage, cleaning of flat plate collector glass, cleaning of water tank and make up tank including dismantling inlet and out let connections and refixing the same after cleaning for proper functioning to maintain proper water temperature complete all as specified and directed.
S&F in replacement flat plate collector size approx 1860 mm x 1240mm x 90 mm ISI marked as per site requirement assembly suitable for solar water system of existing size and capacity with copper tube black coat/radiation reflector film , toughed glass, complete all as specified and directed. Make:-supreme /venus/inter solar/umang/sunzone. Note :All the T&P , Hydra , Crane arrangement required for carrying/Displacing material from ground to triple storage building shall be arranged by contractor at his own cost and the cost is inclusive in qouted rate.
S&F in replacement only solar toughened glass plate suitable for collector plate of size approx 1860 mm x 1240mm x 90 mm as per availlability at site complete all as specified and directed. Note:All the T & P , Hydra , Crane arrangement required for carrying/Displacing material from ground to triple storage building shall be arranged by contractor at his own cost and the cost is inclusive in qouted rate.
S&F nytryl rubber suitable for Solar water heater plant of Cap 100/200/300 ltrs Solar water heater plant complete all as specified and directed.
M&L for fixing in replacement Solar water heating element for geysers 2 KW, 230 volts AC any type ISI marked complete with rubber gasket including replacing the bolts/screw if any broken during changing the heating elements complete all as specified and directed.
M&L for fixing in replacement Solar water heating element for geysers 3 KW, 230 volts AC any type ISI marked complete with rubber gasket including replacing the bolts/screw if any broken during changing the heating elements complete all as specified and directed.
S&F in replacement temperature gauge steam type range 25 to 90 degree and above in centigrade as per existing size complete all as specified and directed.
M&L for replacement of insulator water tank made out of 1.25mm thick MS sheet with provision of 15mm dia inlet/outlet arrangement for solar water heater capacity 150/200 ltrs complete all as specified and directed. Make:-supreme /venus/inter solar/umang/sunzone. Note:All the T&P , Hydra , Crane arrangement required for carrying/Displacing material from ground to triple storage building shall be arranged by contractor at his own cost and the cost is inclusive in qouted rate.
M&L for replacement of insulator water tank made out of 1.25mm thick MS sheet with provision of 15/20mm dia inlet/outlet as per groung arrangement for solar water heater capacity 300 ltrs complete all as specified and directed. Make:- supreme /venus/inter solar/umang/sunzone. Note:All the T&P , Hydra , Crane arrangement required for carrying/Displacing material from ground to triple storage building shall be arranged by contractor at his own cost and the cost is inclusive in qouted rate.
M&L for replacement of rubber hose pipe 22 to 25mm dia between hot water tank & collector as per ground requirement complete all as specified and directed.
S&F in replacement top cover suitable for HDPE tank cap 100 to 500 ltrs complete all as specified and directed.
S&F 500 ltrs ISI marked, HDPE rotational moulded polyethlene cylindrical vertical water storage tanks conforming to specification of IS:12701-1996 with amendment No 1 covered by fig 1) hoisted and fixed in position, including disconnecting old tank complete all as specified and directed. Make : Sintex/Polycon/Fusion. Note: All the T & P , Hydra , Crane arrangement required for carrying/Displacing material from ground to triple storage building shall be arranged by contractor at his own cost and the cost is inclusive in qouted rate.
S&F cross arms, bracings supports, clamps and back plates fabricated from structural steel sections including nuts bolts, washers, welding bending cold or hot,drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coat of synthetic enamel paint over a coat of red oxide primercomplete all as specified and directed .
S&F in replacement CPVC tubing medium grade and fixed to walls & ceilling or laid in floors, bore of pipe 20 mm complete all as specified and directed.
S&F in replacement GI tubing medium grade with all fitting and fixed to walls & ceilling or laid in floors, bore of pipe 15 mm complete all as specified and directed.
All as per item No 67 here in before but bore of pipe 20 mm.
All as per item No 67 here in before but bore of pipe 25 mm.
S&F in replacement 15 mm bore gun metal gate/stop valve (ISI Mark) with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
All as per item No 70 here in before but gun metal gate/stop valve 20 mm.
All as per item No 70 here in before but gun metal gate/stop valve 25 mm.
S&F PVC insulated PVC sheathed flexible round stranded copper wire 6.0 sqmm 3 core complete all as specified and directed.
S&F GI union 25 mm for pipe connection any type as per ground requiremet for solar water heater complete all as specified and directed.
S&F GI elbow 25 mm for pipe connection any type as per ground requirement for solar water heater complete all as specified and directed.
S&F GI Tee 25 mm for pipe connection any type as per ground requirement for solar water heater complete all as specified and directed.
S&F CPVC Elbow 20mm for pipe connection any type as per ground for solar water heater complete all as specified and directed.
S&F socket fitting as per ground requirement for connection of pipe and solar plate of suitable size complete all as specified and directed.
S&F float ball valve 25mm size high pressure ,polythene float an flynut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F thermostat of type EST 11/20A, 240 Volt of approved make and having ISI mark complete all as specified and directed.
Stretching / restringing only ACSR conductor in position on LT over head lines of any size,type, span length with permisiable span sag and binding with pin/shackle insulator with new aluminum binding wire not less than 2mm dia complete all as specified and directed.specified and directed.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 89,930.00 (refer Tender Srl Page No 36). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
M/S R. K. INDUSTRIES
GURUNG CONSTRUCTION
M/S POWER ENGINEERS
M/S Vaishno Constructions
S K ENTERPRISE
UNIVERSAL CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .