Nirman Sadan 2nd Floor Civil Line Gurugram
Sub Health centre at Village Wazirpur and Sub Health centre at Village Jatola
2020_HRY_118150_1
PWD/PD2GGN/12/02/2020-3
Open Tender
Civil Works
Item Wise
90 days
Gurugram
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Provincial Division No 2 PWD BR
₹28,000
Yes
23 Dec 2020
13 Feb 2020
28 Feb 2020
13 Feb 2020
26 Feb 2020
13 Feb 2020
Amount
Scraping-White wash and colour wash (HSR-8.32 a )
Removing door and windows (wood and steel) with chowkats by making Recesses in walls when the wall is not to be dismantled (HSR-8.18 a)
Removing door and windows (wood and steel) with chowkats by making Recesses in walls when the wall is not to be dismantled (HSR-8.18 b)
Factory manufactured solid flush door shutters, with block board core as per I.S. No. 1659-1669 bonded with water proof type phenol formaldehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part-I and II, fixed in position, including iron hinges, screws chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position):- (Note) :- Commercial veneering with vertical grains or cross bands and face veneer on both sides commercial facing with laminated core and lipped edges. (Duro, Green) 25 mm. thick (HSR 17.93 (a) (i)- note I under 17.18))
Factory manufactured solid flush door shutters with block board core as per I.S no. 1659-1669 bonded with water proof type phenol formaldehyde synthetic resin, hot-pressed, conforming to I.S 2202 part-I anf II fixed in position, including iron hinges, screws, chocks/cleats, and stops etc. (Excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position) -(Note) : - Commercial veneering with vertical grains or cross bands and face veneer on both sides commercial facing with laminatyed core and lipped edges. (Duro, green) 35 mm thick (HSR 17.93) (a) (iii))-Note I under 17.18.
Factory manufactured panelled door or glazed window, shutters of commercial hard wood, such as hollock, champ, chikrassy & chaplash etc. (Non-coniferous timber other than teak, conforming to IS specification no. 1003, Kiln-seasoned) with 100 mm wide vertical styles, 150 mm wide lock rail, 200 mm wide bottom rail and 100 mm ide other rails and 100 mm wide other rails with panels of 15 mm thick tongued and grooved of commercial hrd wood and including costof iron hinges, screws, chocks, cleats, stops, nails etc. complete fixed in position (Excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position) -(b)- 35 mm thick (HSR 17.90) (b)-Note I under 17.18.
Plastering on walls 12 mm thick cement plaster 1:4 (HSR 15.5)
Plastering on walls 12 mm thick cement plaster 1:2 (HSR 15.3)
Dismantling-tile terracing dismantled form tile work in lime or cement (HSR- 8.32 g)
Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and another layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of RCC slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13)
Distempering with washable oil bound distemper (of approved manufacture) two coats on old distempered work.(HSR-16.60) (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, drum of paint shall be opened in presence of Engineer-in-charge).
WHITE WASHING-Two coats (HSR-16.47)
Finishing walls with exterior decorative cement based paints such as snowcem, Robbiacem etc. on new work, two coats to give an even shade.(HSR-16.61)
Preparation of ply wood surface for painting inlcuding sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. Painting on wooden surfaces etc. (HSR 16.1)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.2).
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.3).
Providing and laying granular sub base consisting of drainage layer confirming to Table 400.1 Grading –VI of MORT&H 5th edition, mixing in a mechanical mix plant at OMC, carriage of mix material to the site of work, spreading in uniform layer with motor grader on prepared surface and compacting with vibratory power roller to achieve desired density complete as per clause No.401 of MORT&H specifications for road & bridge (5th Revision) of 2013
Providing and laying 80mm thick ISI marked interlocking paver blocks confirming to IS : 15658:2006/IRC SP 63-2004 of all shapes and colours in design mix M-40 over a bed of 30 mm thick fine sand complete in all respects. [HSR 10.159]
First class brick work laid in cement sand mortar 1:6 in foundation and plinth (HSR 11.2)
Wrought iron and mild steel (using angles, flats, square bars, tees and channels), ladders, grills gratting frames, window guards, iron doors openable or fixed staircase or parapet or any other type of railing, gates and tress guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position (HSR 18.12)
Providing and fixing rectified ceramic tiles/ anti skid tiles of size 400x400mm of approved make in floors laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK & SIMPOLO (HSR 14.91)
Providing & Fixing Ist Quality ceramic glazed wall tiles conforming to IS. 15622 ( thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry including ointing in white cement mixed with pigment of matching shades complete. (a) size of ceramic glazed tiles 200 x 300 mm of reputed manufacturer like:- RAK, N"ITCO, Kajaria, SIMPOLO & ORIENT BELL shall be used as approved by Engineer-in-charge (HSR 14.92) (a) Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material
Earth filling under floors with tibba sand non plastic under floors with good earth taken from outside of campus area with all lead and lift including loading, unloading, laid in 15 cm layer including ramming, watering, consolidating, compaction, and compensation of earth etc. complete in all respect as per the direction of engineer in charge (For any lead lift) (N.S Items)
Dismantling/removing of existing interlocking paver blocks pavement including transporting and stacking usable block along road side and dispose unusable blocks outside PWD land or desired by Engineer (NS)
Relaying old 80 mm thick interlocking paver blocks over 30 mm thick fine sand including transportation from road side where stacked excluding cost of interlocking paver blocks and complete in all respect as per specifications (NS).
Public Health item :- Providing and fixing G.I pipes complete with G.I fitting and clamps, i/c cutting and making good the wall etc. internal work -Exposed on wall (DSR-18.10)--(i) 15 mm internal diameter of pipeline
20 mm internal diameter of pipeline
Providing, Fixing gun metal peet valves with C.I wheel of approved quality (Screwed end) (DSR-18.17) 20 mm nominal bore
Providing & fixing G.I Union in G.I pipe including cutting and threading the pipe and making long screws etc complete (New work) DSR-18.46) 15 mm internal diameter
20 mm internal diameter
Providing & fixing PVC rainwater pipe 6 kg. pressure of ISI mark in cement mortar during masonary work (b) 150 mm dia PVC pipe 6 kg pressure (Note:- Reputed make PVC pipe such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge (HSR. 13.89) (b). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material --
Providing and fixing PVC bend ISI mark (b) 150 mm dia PVC bend (Note:- Reputed make PVC bend such as Supreme, Finolex, prince will be used as approved by Engineer-in-charge. (HSR 13.90)(b) Note The Agency to whom the work ia alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material
Providing and fixing HDPE water storage tanks of sintex, Diplast, O.K. supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing Iin position, making connections with inlet and outlet pipes, providing overflow and scour provisions with suitable plug on scour pipe including cost of nipples, washers, flanges for connections in tanks complete in all respects to the satisfaction to the Engineer. (HSR-30.119)----500 Ltr. Cap.
1000 Ltr. Cap.
Providing and fixing in position best Indian make (to the approval of the Engineer-in-charge). Indian type orissa or orya water water closet suite for sinking into floor, with raised foot treads complete with 100 mm HCI 'P' trap with or without vent as required and all other necessary fitting as fully described in item no. 30.1. (HSR-30.2)a) Size 580mm (i) White.
Providing and fixing in position best Indian make European type water closet suite with concealed 'P or 'S trap with or without vent (as approved by the Engineer-in-charge) and all other necessary fitting as fully described in item no. 30.3 above. (HSR-30.6)(i) white
Providing and fixing 15 liters capacity low level vitreous china ware cistern complete with flush bend all other necessary fitting instead of C.I high level cistern complete with fitting.(HSR-30.12)(i) white
Providing & fixing in position best Indian make white lavatory suites (with full anti splash rim in vitreous chinaware and all other necessary fittings as fully described in item no. 30.41 above (HSR-30.42)
Providing and fixing in position best quality stainless steel sinks with complete fittings as fully described in utem no 30.51 above (HSR-30.53)a) 600 mm x 450 mm x 200 mm
Providing and fixing in position 15 mm I/d C.P. brass bib cocks of best quality (as required by the engineer I charge)(HSR-30.75)(a) Bib cock long body
Providing and fixing HCI floor traps ISI marked of the self cleaning design with C.P brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors etc. minimum depth of water should be 150 mm with a minimum seal of 50mm (HSR-30.89)b) With 75mm I/d outlet.
Recovery Items:-Bidder have to quote rate for recovery items at least or more than reserve price. The rate quoted against recovery items will not be included in the total amount rather it will be deducted while calculating financial statement of the agency.T Note:- The reserve rate/amount is minimum amount to be used as base for quoted purchase rate by the agency. No rates/amount below the reserve price will be entertained and reserve price will be considered for all purposes in case the agency quotes lesser than reserve price.--Door @ 100/-Each
Window @ 50/-Each
Tile @ 4.50/-Each
Brick bats @ 400/-per cum Note:-In case of any difference in the unit & nomenclature of any of the HSR items of Civil, P.H and E.I depicted in this DNIT and that given in HSR, the unit and nomenckature given in HSR shall be applicable.
P C Gupta and Co
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .