Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance A 18 GR FLOOR SITA ESTATE AZIZ BAUGH MAHUL ROAD CHEMBUR E MUMBAI 400 074 | MUMBAI SUBURBAN | MAHARASHTRA | 400074 | Admitted-Finance |
Tender Value
₹73.5 L
EMD Value
₹1.7 L
Closing Date
9 Dec 2024, 6:00 pmClosed
Chief Engineer and Head, CSS
Chief Engineer and Head, CSS, TSD Building, BARC Trombay 400085
Maintenance of Diesel Generator Sets and Diesel engine of Fire Hydrant Pumps installed at various BARC facilities in Mumbai and Mumbai Suburban
2024_BARC_836911_1
BARC/CSS/ET/40/2024-2025
Open Tender
Electrical Works
Item Rate
1095 days
Mumabi and Mumbai Suburban
As per the NIT
8 documents required · 8 mandatory
₹0
₹1.7 L
Anushaktinagar, Mumbai
7 Jan 2025
28 Nov 2024
12 Dec 2024
28 Nov 2024
9 Dec 2024
28 Nov 2024
28 Nov 2024 - 5 Dec 2024
3 Dec 2024
Amount
Maintenance/Servicing of 625 KVA DG sets along with AMF panel as per TSS 1
Maintenance/Servicing of 250 KVA & below 320 KVA DG sets along with AMF panel as per TSS 1
Maintenance/Servicing of 120 BHP and below Diesel Pump in BARC Trombay. as per TSS 1
B-check of 625 KVA and above DG sets as per TSS 2
B-check of 200 KVA to 250 kVA DG sets as per TSS 2
B Check of 127 BHP and below Diesel Pump in BARC Trombay as per TSS 2
C-check of 200 KVA DG sets to 625 KVA DG sets as per TSS 3
Load test of 200 KVA to 625 KVA DG set with resistive load bank as per TSS 4
Supply, installation, testing and commissioning of battery bank of 180AH,12V as per TSS 5
Supply, installation, testing and commissioning of maintenance free battery bank of 65AH,12V as per TSS 6
SITC of extension of existing Engine silencer & its exhaust pipe with glass mineral insulation and its all required fittings supports and all accessories as per TSS 7
SITC of automatic voltage regulator(AVR) suitable for 125-500KVA KEL/Stamford alternator as per TSS 8
SITC of 12/24V, 15/20 Amp. automatic float cum boost battery charger as per TSS 9
SITC of control contactor 12V/24V DC with 2NO +2NC contacts with inbuilt surge suppression as per TSS 10
SITC of Magnetic pickup unit (MPU) suitable for various cummins make engine & KOEL Engine as per TSS 11
SITC of Power command unit (PCC1301 or equivalent Cummins make) suitable for 6CTAA 8.3 Engine control assembly and assembly control unit as per TSS 12
SITC of PCC 3.3 display Unit with base board for Cummins Make engine as per TSS 13
SITC of AMF controller (Easygen 350X woodwork or equivalent) suitable for 200 to 625 KVA AMF Panel as per TSS 14
SITC of Generator Control Unit for KG 745 KOIL / DSE MAKE TYPE-DSE 7320 MK II for DV 12 TAG1 Engine as per TSS 15
Supply Installation, testing and commissioning of Starter Motor 24 V DC REIL Make series R-50 Type 400 suitable for DV 12 KOIL Engine as per TSS 16
Supply Installation, testing, commissioing of AC Volt meter Range 0-500 V Analog 96mm Flush Mounting as per TSS 17
Phasing and calibration of PT pump of Cummins make including injector nozzle servicing including auxiliaries supply (such as washers, O-Ring , Injector Nozzle etc.) as per TSS 18
Calibration & servicing of Fuel pump & injector for DV12 Kirloskar engine including auxiliary supply (Such as washers, O-ring, Injector Nozzle) as per TSS 19
Supply and filling of Engine coolant as per specifications as per TSS 20
Supply , refilling of lube oil- Multigrade (Grade-15W40) as per TSS 21
SITC of lube oil pressure sensors suitable for various cummins make engine & KOEL Engine as per TSS 22
SITC of Coolant temperature sensors for 125KVA to 500 KVA cummins engine as per TSS 23
SITC of DC Coil 24V 4ST for Engine Cranking as per TSS 24
SITC of 12V/24V DC Solenoid coil for Starter Motor as per TSS 25
SITC of 24V DC Fuel solenoid switch/coil suitable for NTA,NTC, 6BTA,6CTA, QSB5.9, QSL9 cummins engine as per TSS 26
SITC of starting motor 12/24V DC ON delay/ OFF delay timers suitable for DG sets and Diesel Pumps as per TSS 27
SITC of 12V/24V DC Relays , plug in base module type suitable for DG sets and Diesel pumps installed in various facilities of BARC, Mumbai as per TSS 28
SITC of Voltage Monitoring Relay 3 phase as per TSS 29
SITC of V-belt set for various cummins make engine & KOEL Engine as per TSS 30
SITC of Hose pipe with clip set for various cummins make engine & KOEL Engine as per TSS 31
SITC of brass check valves for diesel fuel line of DG sets of 30 KVA to 500 KVA installed in various facilities of BARC as per TSS 32
SITC of MS 25mm Schedule 40 fuel piping work from fuel tank to engine (supply and return) including bends flanges, supports and painting works as per TSS 33
Supply, and installation of High pressure pipe set for fuel and Lube-oil for various Cummins engine & KOEL Engine as per TSS 34
SITC of Hydro meter for specific gravity measurement of battery
Supply, installation of AMF panel door lock with key
Supply, installation of SS door lock for acoustic canopy door
Supply, installation and testing of SS door hinges (150 mm x 50 mm x 3mm) for acoustic canopy door along with SS nut and bolts
SITC of 20W LED lamp with holder and bulk head as per TSS 35
SITC of Heavy duty brass Battery terminals suitable for 180AH battery
Aluminium HT600 Painting work for exhaust silencers as per TSS 36
Leakage arrest of coolant from radiator tube for DG stes with dismantling & reassembling of water pump, fan guard etc as per TSS 37
Leakage arrest of lub oil from oil cooler/ fuel injection pump for DG set as per TSS 38
Items fabricated out of CRCA carbon steel sheet as per TSS 39
Items fabricated out of carbon steel structural members (channel, angle etc) as per TSS 40
Kalpaka Power Control (BID ID -3129124)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .