Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LQualified AWFIS SPACE SOLUTIONS GESCO 70 THE GREAT EASTERN CENTRE NEHRU PLACE BEHIND IFCI TOWER NEW DELHI SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | ₹48.9 L | L1 | Qualified MSE, MII, Category: General |
| 2 | L2₹60.6 L+₹11.8 L (24.0%)Qualified A2 73 UPSIDC KASNA SITE V CONWAVE POWER SOLUTION KASHNA VILLAGE TOWN GAUTAM BUDDHA NAGAR CITY GAUTAM BUDDHA NAGAR | ₹60.6 L+₹11.8 L (24.0%) | L2 | Qualified MSE, MII, Category: General |
| 3 | Disqualified SF 3 2ND FLOOR RELIABLE ARCADE JAIPURIA ENCALVE KAUSHAMBI GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | - | - | Disqualified MSE, MII, Category: General |
Tender Value
₹59.0 L
EMD Value
₹1.2 L
Closing Date
26 Dec 2024, 3:00 pmClosed
SITC of Retrofit Emission Control Device etc.
3core 4 SQMM armoured power cable
Supplying and fixing 20 amps SPN industrial type etc
Structural steel work riveted etc
Extension of exhaust pipe of Exisiting 2 X 750 DG Set etc
Cost for providing and operating of crane having capacity 50MT etc
Providing and laying in position specified grade of reinforced cement concrete etc
Steel reinforcement for R.C.C work including straightening etc
7202428
GEM/2024/B/5664836
Two Packet Bid
SITC of Retrofit Emission Control Device etc.,3core 4 SQMM armoured power cable,Supplying and fixin
75 days
Jammu And Kashmir; Budgam
Total value wise evaluation
BOQ
10 documents required · 10 mandatory
3 yrs
₹3
80%
₹1.2 L
26 Dec 2024
5 Dec 2024
26 Dec 2024
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | SITC of Retrofit Emission Control Device etc. | Supplying, Installation, Testing & Commissioning of retrofit Emission control device on following capacities DG sets to reduce particulate matter, Hydrocarbon and Carbon Monoxide emission by at least 70% in 5 mode D2 cycle. Device should be Type Approved as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021- 22 Adhering to this, RECD to be Type Tested for equivalent kVA rating from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/ laboratories as given below (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar)(c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar) RECD should not consume additional electricity/power either from the main supply or DG set for emission reduction. RECD should be installed on the top of the DG set, with available space. No extra space to install RECD will be provided around DG set considering the constraint of the space and its cost. (Make Chakr Shield/ SRG Solution/ Vihi RECD).(i) 750 KVA | 2 | No | [email protected] | 75 |
| 2 | 3core 4 SQMM armoured power cable | Supply of following sizes of Copper Conductor XLPE insulated PVC innersheathed, 1.1 KV grade power cables conforming to IS 7098 (Part-I) 1988 and as per specification as required. a) 3C X 4 Sqmm Cu Armoured | 100 | Meter | [email protected] | 75 |
| 3 | Supplying and fixing 20 amps SPN industrial type etc | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | 4 | No | [email protected] | 75 |
| 4 | Structural steel work riveted etc | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (a) Size of 100mm x 100mm x 5mm & (b) Size of 75mm x 40mm & (c) Size 50mm x 50mm x 5mm iron angle etc. | 4,000 | KG | [email protected] | 75 |
| 5 | Extension of exhaust pipe of Exisiting 2 X 750 DG Set etc | Extension of exhaust pipe of Exisiting 2 X 750 DG Set with MS C Class of 300 mm Dia pipe with aluminium sheet clading on glass wool insulation of 5mm thick inclusive of welding and cutting of pipe etc complete as required as per specification. | 35 | Meter | [email protected] | 75 |
| 6 | Cost for providing and operating of crane having capacity 50MT etc | Cost for providing and operating of crane having capacity 50MT to lift and install iron structure for supporting for exhaust pipe line for DG sets including driver, helper diesel etc complete as per direction and satisfaction of Engg-in-Charge. | 5 | Day | [email protected] | 75 |
| 7 | Providing and laying in position specified grade of reinforced cement concrete etc | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1 2 4 (1 cement 2 caorse sand (zone-III) derived from natural sources 4 graded stone aggregate 20 mm nominal size derived from natural sources) . | 10 | Cum | [email protected] | 75 |
| 8 | Steel reinforcement for R.C.C work including straightening etc | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (including foundation bolt 25mm dia and minimum 1.2 m long) Thermo Mechanically Treated bars of grade Fe-500D or more. | 80 | KG | [email protected] | 75 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_7202428.pdf
GEM_BID
nitrecd_2024-12-05-15-38-50_13703b65cc2e261d20550797eaf2003c.pdf
BOQ
boqrecdf_2024-12-05-15-38-50_e65a723ef142e78c6ce3014e15f6e5d6.csv
BOQ
NITRECD_57a546de-8cab-47fc-91e71733393750941_vipinm21@aai.aero.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .