Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC H NO 767 NEAR OLD POST OFFICE NEW VADDEM VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹1.3 Cr | L1 | Accepted-AOC ACCEPTANCE |
| 2 | L2₹1.4 Cr+₹4.8 L (3.66%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.4 Cr+₹4.8 L (3.66%) | L2 | Rejected-Finance HIGHER BIDDER |
| 3 | l3₹1.4 Cr+₹7.0 L (5.31%)Rejected-Finance FLAT NO 7 MHAMBRE BLDG DR FRANCISCO LUIS GOMES ROAD VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹1.4 Cr+₹7.0 L (5.31%) | l3 | Rejected-Finance HIGHER BIDDER |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Recommended as wrong DD Uploaded |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
10 Apr 2024, 6:00 pmClosed
COL BHUPINDER SINGH CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO AIR STORE WEST BLDG No P 279 AT INS HANSA
2024_MES_635553_2
85734/E8
Open Tender
Civil Works
Item Rate
270 days
CWE NAVY VASCO
AS PER TENDER DOC
9 documents required · 9 mandatory
₹1,000
GE (NW) VASCO
₹2.2 L
Yes
8 Jun 2024
20 Mar 2024
12 Apr 2024
20 Mar 2024
10 Apr 2024
27 Mar 2024
Amount
Schedule 'A' Part I - B/R Portion
Chipping loose concrete and Exposing existing RCC columns,beams,slabs,lintels,pardis etc.including plaster beyond main reinforcement carefully by means of chisel and hammer or mechanically including necessary double scaffolding ,erecting horizonal platforms at working levels to collect the debris, proping with top and bottom runners as directed stacking the debris in the compound as directed and caring away the same outside the premises etc. complete all as specified and as directed by Engr-in-Charge
M&L for Relieving structural members such as column,beam and slabs of their superposed loads partially or fully by provison of adjustable steel props, frams etc. including providing necessary timber runners,bracing , jacking up arrangement all complete to the satisfication of Engineer incharge (Removing and redoing of brickwork, if required ,shall be paid separately).
M&L for Chipping of existing loose,damaged concrete from RCC members of all affected RCC Columns,Beams, Slabs and Chajjas on External and internal facades etc beyond main reinforcement (if requried in the opinion of the Consultant),carefully with chisel and hammer providing and applying ' Rusticide SS' Rust passivater or equivalent as specified in the Brand Names to existing reinforcement bars including wire brushing of reinforcement,cleaning washing of concrete etc complete as directed.Providing and applying two coats of rust preventor slurry made out of " Polyalk Fixoprime"or equivalent as specified in the Brand Names and cement in proportion 1:1:5 to existing reinforcement bars as directed complete.Providing and applying bonding coat of slurry made out of "Polyalk EP" or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and reinforcement substrates complete as directed Providing and applying "Polyalk EP" or equivalent as specified in the Brand Names,Polymer modified cement mortar in Required proportion(1:5:15) to RCC members including hand packing,curing and making the surface rough for plastering complete all as specified and as directed by Engr-in-Charge
FILLING AND REINSTATING OF SEPARATION CRACKS (a) M&L for Opening the Separation cracks at the Juction of RCC and Masonry where ever directed and instructed into "V" Grooves 2" to 3" from the either side of the cracks by carefully marking the areas to be opened up using a cutting machine and skillfully Chiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete Substrata and masonry wall with water jet to the surfaces thus prepared to the entire satisfication of the Consultant as instructed and directed.
(b)M&L for Moistening the cracks ,providing and applying primary/bonding coat of slurry made of "Polyalk EP" and cement(or equivalent as specified in the list of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed.Filling the cracks Grooves by Providing and applying "Polyalk EP" Polymer modified cement mortar (or equivalent as specified in the list of Brand names) in Proportion of 1:5:15 (Polyalk EP: Cement:Graded sand/quart/sand ) on the prepared surfaces and finishing it in the level with the existing plaster including hand packing curing and making the surface similar to the external plastering using wooden floats/punch etc.complete as per specified and directed.
M& L for Drilling holes of required size upto 16mm Diameter and up to 50mm depth in concrete and cleaning the same as directed.
M&L for 12mm diameter aluminium/PVC injection nipples and securing the same as directed & and injecting cementitious grout using CEBEX-112 additive of 'Fosroc' at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete all as specified and as directed
M&L for epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns before jacketing Micro concreting as per Consultants instructions and directions complete all as specified and as directed
M&L for cutting,bending and fixing Additional reinforcement in position, steel reinforcement of specified required sizes and shapes in the form or main rebars, stirrups & rings,distrubtion rebars etc.and tying them to shear connectors using GI Binding wire.The additional rebars should be coted with TWO coats of Anti Corrosive protective coating & dry sand to be sprinkles on second coat , including tying with Annealed Binding wires,providing cover blocks of appropriate sizes etc complete as specified and instructed by the Consultants.
Providing and laying super fluid Microconcrete -Roffe crete repairs (or equivalent as specifed in the list of Brand names) in beam bottoms, columns,slab etc including mixing with 5mm to 10mm size aggregates, waterproof plywood/ steel plate shuttering,pouring,temping,Consolidating,curing etc complete as per Manufacture's specification and Consultants instructions. The item shall be paid on actual consumption of Micro concrete.
M&L for laying in slabs,beams,pardise,RCC wall etc postion of RCC M-25 design mix grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying and the cost of centering,shuttering form work,finishing and excluding reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete,improve workability without imparing strength and durability as per direction of Engineer-in charge.The Mix design as per particular specifications shall be got approved by Enginner -in charge before execution of the item. The rate shall include cost of all specified materials and operations at all levels and heights,including the cost of centering ,shuttering and form work excluding reinforcement which shall be paid under relevent item complete all as specified and as directed (Note:- Cement content considered in this item @ 300 kg/cum as per IS 456 table showing minimum cement content.No extra will be paid nor any amount will recovered on account of variation of cement in mix design as per specifications for controlled )
M&L for applying Glass Fiber sheet wrap at structural members including .surface prepartion: Grinding/Moulding concrete substrate ,cleaning it with wire brush,removing oil,laitance if present,rounding sharp edges to min 25mm radius etc,complete incl Applying PRIMER on prepared substrate,filling holes and uneven surface with PUTTY etc, complete.Wrapping the Glass fibre wrap to voids etc.Repeat the same procedure for multiple layer with interval of 8 hours. Sand pasting:Applying saturant,rectify air voids if any , paste the river sand on it to make surface rough to take any further finishes complete all as specified and as directed. (Mode of Measurement:Per Sq.Mt of fiber consume and not application and not application of surface area.)
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and as directed by Engr-in-Charge
Dismantling mild steel work of any description not otherwise provided for complete all as specified and as directed by Engr-in-Charge
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-W including cleats,distance pieces etc complete all as specified and as directed by Engr-in-Charge
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
S&F PVC Rain Water Pipe 150 mm dia including all fittings, head , shoes, branches all as specified fixed in wall including joint with PVC adhesive complete all as specifed and as directed
S&F PVC plain bends 150 mm bore omplete all as specifed and as directed
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as specified and as directed
Supply & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with ANF (Board) edge tiles with Armstrong 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 90%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 34%.The tile shall be laid on Armstrong Prelude38 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. The Tile & Grid system used together should carry a 10 year warranty all as directed by Engineer in Charge.
Dismantling timber scantling framed work in fillets, rails, posts, rafter purlins, etc. under 40 Sqcm in section complete all as specified and as directed
S& F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified
S& F solid PVC Wall Lining consisting of 5 mm thick single side prelam PVC sheetincluding of solvent cement and fixing at site on PVC frame as per manufacturer specifications complete all as specified and directed
Taking down chowkat or frames n. exc 1.5 sqm each (without taking of shutters from the frame ) complete all as specified and directed.
Taking down chowkat or frames exc 1.5 sqm but n. exc 4 sqm each (without taking of shutters from the frame ) complete all as specified and directed.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm comlete all as specified and directed.
S&F 30 mm thick Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats complete all as specified and as directed
M&L for preparation of new or previously untreated surfaces of anydescription, not otherwise described,over 10cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed
S&F powder coated aluminium door and window shutter and frame any type (sliding or openable) and other similar work etc 60 micron section, fabricated by using the JINDAL / INDAL / HINDAL CO / CENTURIAN sections including all necessary roller wheels for window, cleats , handle, door stoper, handle, locking arrangement, Mortice lock and arrangements to received glass/ prelaminated particle board with aluminium beading and stainless steel screw incl cost of rubber gasket beadings etc complete sealing between frame & wall with epoxy sealing compound. (The weight of rubber gasket beading will not be measured and paid, glass and prelaminated particle board will be measured and paid seperately) All sections as approved by GE
S&F Powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including standed aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and directed
S&F solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, fixed in position complete all as specified and as directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face including 20 mm thick PVC lining around all 4 edges of shutter, supplying & fixing in frame at site as per specification & drawing all as specified and directed.
S&F Factory made 100% solid wood plastic(WPC) Decorative Door Frame,single rebate of size 75mm x 50mm made from wood plastic composite(single extruded process) material with density 780 Kg/Cum complete all as specified and directed.
S&F Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber/aluminium frame work in cup board shutters, partitions, shelves, pelmet boxes or narrow widths and similar works complete all as specified and as directed
S&F 18 mm thick single side prelaminated woodgrain solid PVC sheet suitablely fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work with all fittings and locking arrangements all as specified and directed.
S&F 200 mm long Aluminium anodised,barrel tower bolts of extruded section complete all as specified and as directed
S&F butt hinges medium weight stainless steel 100 mm size complete all as specified and directed
S&F 150 mm long Extruded aluminium alloy,handles, fabricated type,anodised complete all as specified and as directed
S&F Aluminium alloy, anodised,sliding door bolt 300 mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
S&F in repairs Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of cover plate 140 mm complete all as specified and as directed
S&F in repairs Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless wire staples complete all as specified and as directed.
S&F in repairs Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed .
S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed.
S&F in repairs aluminium (die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed
Dismantling/Taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled complete all as specified directed by Engr-in -charge.
M&L for Rendering 10mm thick in CM 1:4 mixed with integral water proofing compound over roof top surface incl filling all cracks by forming groove of 5mm x 5mm finished to even & smooth w/o using extra cement complete all as specified and as directed Note :- Integral water proofing compound will be measured and paid seperately
M&L for Applying evenly a priming/tack coat with oil bound bituminous primer at 0.4 Ltr per 10 sq metre complete all as specified and as directed
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as directed
Demolition of unreinforced cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed
M&L for 25 mm thick Cement concrete type B-1,1:2:4 using 20mm graded granite aggregate ) in roof for maintaining proper slope to avoid waterlogging complete all as specified and directed.
M&L for 100 mm thick Cement concrete type B- 2, 1:2:4 using 40mm graded coarse aggregate complete all as specified and as directed
M&L for 75 mm thick Cement concrete type C- 2, 1:3:6 40mm graded stone aggregate in subbase,plinth protections, finished even and smooth w/o using extra cement complete all as specified and as directed
Taking down Stone slabs and tiles of any description or thickness in floors/ dado etc. laid beded and pointed in any mortar
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 18-20 mm thick over 20 mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed
M&L for Machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar incl 10 mm thick backing coat in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed
M&L for Rubbing and mirror polishing to old kota stone flooring complete all as specified and as directed
M&L for Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed
M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and incl Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 complete all as specified and as directed by Engineer in Charge
M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting/ dado set and jointed in neat cement slurry and pointed in white or coloured cement to match incl backing layer of mortar 10 mm thick in CM 1:3 complete all as specified and as directed by Engineer in Charge
M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and incl Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 complete all as specified and as directed by Engineer in Charge
M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting/ dado set and jointed in neat cement slurry and pointed in white or coloured cement to match incl backing layer of mortar 10 mm thick in CM 1:3 complete all as specified and as directed by Engineer in Charge
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and incl Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 complete all as specified and as directed by Engineer in Charge
M&L for coloured Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl backing layer of mortar 10 mm thick in CM 1:3 complete all as specified and as directed by Engineer in Charge
M&L for 2 mm thick PVC tiles/ sheets,laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors complete all as specified and as directed
Dismantling water tanks and removing to store exc 500 ltrs but n exc 1000 ltrs complete all as specified and directed
Dismantling water tanks and removing to store exc 250 ltrs but n exc 500 ltrs complete all as specified and directed
M&L for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 Ltr capacity hoisted and fixed in position all as specified in SSR Part I incl 20 mm bore PVC float valve complete all as specified and as directed
M&L for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 Ltr capacity hoisted and fixed in position all as specified in SSR Part I incl 20 mm bore PVC float valve complete all as specified and as directed
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 20 mm dia complete all as specified and directed
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 25 mm dia complete all as specified and directed
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fitting in trenches/wall/floor complete all as specified and as directed
Supplying and laying of 25 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fitting in trenches/wall/floorcomplete all as specified and as directed
S&F in repair Stop valves/ angle cock fancy type, chromium plated 20 mm bore ,cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repair Vitreous China wash basin, white, flat back, size 550x400 mm incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe (32 mm) but including waste fittings complete all as specified and as directed
S&F in repair PVC valveless, syphonic action type, flushing cistern, 10 Ltr capacity low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed
S&F in repair Vitreous China wash down water closet pan (Pedestal pattern) white, incl seat and cover, flush pipe incl all joints complete all as specified and as directed.
S&F hand shower (Health faucet) dia 8mm 1 mtr long flexible tube and wall hook Cat No ALD 573 of Jaquar or equivalent in Parko/Kohler complete all as nspecified and as directed
S&F in repairs Soap dish, of material brass with glossy finish,Cat No. BA-45 of Prayag or equivalent complete all as nspecified and as directed
S&F in repairs Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed
S&F in repairs Vitreous China half stall urinals, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, magnum urinal spreader, pointing around urinal back in cement; flush pipe, grating and Union for discharge pipe complete all as specified and as directed
S & F in repairs PTMT 15 mm bore Push taps cast copper alloy high pressure screwed for iron/CPVC pipe for urinal complete all as specified and directed.
S & F PVC Connections 15mm size with PTMT nuts of length 600 mm complete all as specified and as directed
S&F in PVC (SWR) floor trap 75 mm, plain with CP grating including joining with solvent cement complete all as specified and as directed
S & F Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms) 32mm bore complete all as specified and as directed
S&F in repair 15 mm bore, chromium plated bib taps cast copper alloy with crutch or butterfly handle screwed down for iron/PVC pipe complete all as specified and as directed
S&F fancy type pillar taps, long neck, 20 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed as in repair complete all as specified. (Cat No 9204 of Prayag or equivalent of Jaquar/Marc complete all as specified and as directed
S&F in repair Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union alongwith arm 225mm and flange. complete all as specified and as directed
S&F grating round 125 mm size of PTMT (min weight 40 grms)complete all as specified and as directed
S & F Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long.) complete all as specified and as directed
Demolition of stone /boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed
M & L for Pre - cast cement concrete masonry with Grade C-1, 1:3:6 (20mm graded stone aggregate) with solid blocks wall built in cement mortar 1:6 complete all as specified and as directed
Taking down cement plastering of any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed. complete all as specified and as directed
M&L for rendering 5 mm thick in CM 1:3 in ceiling finished even and smooth (without using extra cement) complete all as specified and as directed
M&L for Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid seperately. complete all as specified and as directed
Supply only integral water proofing compound
M&L for rendering 15 mm thick in CM 1:6 on concrete solid block wall internal surface finished even and smooth without using extra cement complete all as specified and as directed
M&L for Preparing new plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling. complete all as specified and as directed
M&L for Preparing new plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall complete all as specified and as directed
M&L for complete removal of existing treatment and Preparing old plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, on ceiling complete all as specified and as directed
M&L for complete removal of existing treatment and Preparing old plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, on walls complete all as specified and as directed
M & L for preparation of new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as specified and as directed
M & L for preparation by complete removal of existing treatment of painted walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm all as specified and as directed. complete all as specified and as directed
S& F in repair Ball brass valve, high pressure, with polythene float horizontal plunger type, IS-1703-2000 marked screwed to iron pipe or brass ferrule of size 25 mm bore complete all as specified and as directed.
S & F in repair Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handle, thickness of lath 1.25mm complete all as specified and as directed.
S & F Ball bearing for rolling shutters complete all as specified and as directed.
M & L for Preparation of new steel surfaces and applying two coat of aluminium paint over a coat of aluminium redoxide primer complete all as specified and as directed.
M&L for Preparation of new steel surfaces and applying two coats of epoxy anti corrossive paint over a coat of zinc primer complete all as specified and as directed.
Schedule 'A' Part II - Sewage Disposal
Demolition and breaking up drain pipes , 150 mm dia (Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar. complete all as specified and directed by Engr-in-Charge.
M & L concrete bed to drain pipe and including packing under haunching against the sides & pipe and after they laid and tested in cement concrete 1:4:8 type D2 bore of pipe 150 mm dia. complete all as specified and directed by Engr-in-Charge.
Supplying and laying of UPVC pipe bearing ISI mark, 150 mm dia heavy duty minimum incl jointing with coupler complete laid in trences or floors complete all as specified and directed by Engr-in-Charge.
Schedule 'A' Part III - Lightening Arrester
M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia upto 7.5 mtr from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed by Engr-in-charge including demolish existing earth pit taking out old materials.. complete all as specified and directed by Engr-in-Charge.
M & L for Earth Continuity conductor as Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engr-in-charge.
S & F Galvanised iron strip 32 x 6mm with saddles and fixing screws etc. for roof conductors and down conductors above ground incl taking out old one complete all as specified and directed by Engr-in-charge.
M & L for Air termination, single pointed, Alluminium rod 12 mm dia and 300 mm long , mounted on alluminium base plate of size 100mm x100mmx 12mm rigid fixed on top roof height complete and insulated from base and taking out old unserviceable complete all as specified and directed by Engr-in-charge.
M & L for Air termination, single pointed, Alluminium rod 12 mm dia and 300 mm long , mounted on alluminium base plate of size 100mm x100mmx 12mm rigid fixed on top roof height complete and insulated from base and taking out old unserviceable complete all as specified and directed by Engr-in-charge.
M & L for test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled and scrwed including 3 Nos. 8 mm dia 25 mm long hex. Head screw complete all as specified and directed by Engr-in-charge.
Supply and lay pipe galvanized, “ Light grade ”, including fittings 40 mm dia. complete all as specified and directed by Engr-in-charge.
Schedule 'A' Part IV - External Electrification
Supply and lay Double walled corrugated pipe (DWC ) confirming to IS 14930 heavy duty 63/50 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
M & L for LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade 120 Sq mm, 3½ core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and as directed.
M & L for LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade 70 Sq mm, 3½ core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and as directed.
M & L for LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade 50Sq mm, 3½ core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and as directed.
Supply and fix or laying in trenches / on wall / poles / structures in repairs GI tubing light grade for road crossing for cable protection of the sizes 80 mm dia including necessary suitable size MS flat fixing clamps, fixing screws complete all as directed.
S & F Perforatted cable Tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, complete all as specified.
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 400 Amps Alcapacity, out door cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings. (Bldg Panel)
INCOMING
(a) MCCB with microprocessor based release, 4 pole, 320 AMPS, 50 Hz, 415 Volt, 36 KA - 1 No (Incoming)
OUTGOING
(a) MCCB 3 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 25KA -04 Nos (Lighting load)
(b) MCCB 3 Pole, 415 V, Adjustable type, 63 AMPS, 18 KA= 01Nos, Spare-01 No
(c) MCCB 3 Pole, 415 V, Adjustable type, 32 AMPS 18 KA -01 Nos
f) CT ratio of 600/5 Amps - set of 3 - 01 set
g) RYB 3 phase indicator lamps set of 03 - 01 set.
Note: Items no. (a) to (g) are deemed to be included in the quoted rate.
M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
Sch 'A' Part V : AIR CONDITIONING
Supply,install, testing and commisioning of vertical pack type units indoor/outdoor complete with cordless remote control unit, twin rotary compressor, single phase units 220V -240V, 50 Hz of capacity 3.5 TR capacity of Non star rating complete all as specified and directed .
Supply and fix Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 5 KVA complete all as specified and as directed
S&F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps complete 'C 'series,415 Volts complete all as specified and irected.
Sch'A' Part VI: Internal Electrification
M & L Point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable in and including PVC concealed conduit 20 mm dia medium grade ISI marked including fittings and accessories with continues PVC insulated copper cable with copper conductor of same size as in phase/neutral/earth cable connecting to common earth dolly including metal flush box and white cover plate with frame complete all as specified and as directed
(a) for light , fan point controlled by one way switch.
b) for 5 Amp Socket point on same board
c) for 5 Amp point on independent board
S/F ceiling rose 3 terminal 230 volts, PVC polycarbonate, isolated body completed all as specified and directed.
S & F Modular switch 1 way 6A, 1 module all as directed.
S & F Modular switch 1 way 16A, 1 module all as directed.
S & F Socket, 6A - 2/3 pin combined 2 module, all as directed.
S & F Socket 6A/16A - 2/3 pin combined 2 module, all as directed.
M&L for point wiring with FRLS cable size 2.5 Sq mm nominal area PVC insulated and unsheathed cable single core multistranded, copper conductor in PVC concealed conduit for one 3 pin, 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed by Engr-in-Charge.Make(cable) - Havells/Plaza/Finolex
M&L for Point wiring with FRLS cable size 4 Sqmm (nominal area) PVC insulated unsheathed multistranded copper conductor cable in and including PVC concealed conduit medium grade ISI marked including fittings and accessories with continues PVC insulated copper cable with copper conductor of same size as in phase/neutral/earth cable connecting to common earth dolly for geyser/Ac point. Make(cable) - Havells/Plaza/Finolex
S & F MCB TPN 63 Amps 415 volts all as specified and directed by Engr-in-charge. (Make- L& T ,Legrand, C & S, Havells).
S & F MCB TP 63 Amps 415 volts all as specified and directed by Engr-in-charge. (Make- L& T ,Legrand, C & S, Havells).
S & F MCB SP 6 to 32 Amps 240 Volts all as specified and directed by Engr-in-charge. (Make- L& T ,Legrand, C & S, Havells).
S & F MCB SPN 6 to 32 Amps 240 Volts all as specified and directed by Engr-in-charge. (Make- L& T ,Legrand ,C & S, Havells).
S & F MCCB 4 Pole 125 Amps 415 Volts 18 KA including incloser complete all as specified and directed by Engr-in-charge. (Make- L& T ,Legrand ,C & S, Havells).
S&F MCB DB TPN double door 4 way 415 volts all as specified and directed.
Supply and fix SPN 12 way DB with 200 amps rated bus bar Double door sutaible for 230 V , 50 HZ
S & F MCCB DB VTPN, 4 way, (MCCB + 12 way O/G) double door, vertical type icluding one MCCB of 63 amps breaking capacity 16 KA , 4 pole without MCB complete all as specified and as directed
S&F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified.
S & F in repairs wall mounting Plug and socket DBs TPN 32 Amp Complete all as specified. (Make :- CG/ C & S / Legrand)
S & F in repairs wall mounting Plug and socket DBs TPN 63 Amp Complete all as specified.
M & L for sub main wiring in replacement with 4 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith two run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through PVC conduit as reqds size confiming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area.
All as per item No 151 here in before, but four run of single core 6 sqmm and two run of 4 sqmm cables as earth continuity conductor all as directed.
All as per item No 151 here in before, but two run of single core 4 sqmm and one run of 2.5 sqmm cables as earth continuity conductor all as directed.
S & F Energy efficient surface Mounted LED Luminire 20 watts 4' long, with acrylic cover aluminium exeruded body complete all as specified and directed by Engr-in-Charge. Make :- bajaj/C&S/Cromton greaves
S & F in repairs Energy efficient surface Mounted LED Luminire 10 watts 2' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr all as directed.
S & F in repairs LED panel 2' X 2' recess mounting luminaire suitable for armstrong/grid/ Pop ceiling complete with separate electronic driver & high brighteness SMD Leds complete all as specified and directed by Engr-in-charge. Make: Philips, Bajaj, wipro
S&F in repairs stepped type electronic fan regulator flush type as per exisitng model on the existing board all as directed.
Supply and Fix in repair Ceiling Fan motor with body complete suitable 1200 mm Sweep matching to blade of existing ceiling fan complete with taking down all as specified and as directed.Make :- Bajaj/Philips/C&S
Supply and Fix in repair Fan Blade set of three suitable of any make and sweep up to 1200 mm sweep matching to existing ceiling fan all as specified and as directed.Make :- Bajaj/Philips/C&S. Note:- Fan Blade make and size shuld be supply with the mach of under relivent item of Sch A serial No 158 as above.
Removing old unserviceable Motor assembly from exhaust fan and supply and fix exhaust fan Motor assembly suitable of size 300 mm to 450 mm sweep and including locking nuts and testing complete all as specified and directed.
Removing old unserviceable blade assembly from exhaust fan and supply and fix exhaust fan blade assembly suitable of size 300 mm to 450 mm sweep and including locking nuts and testing complete all as specified and directed.
Supply and fix in repairs new wall mounted fan of existing make and type all as directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed by Engr-in-Charge
Supply and fix copper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade, 3 core ;2.5 sqmm and including connection to geyser and plug outlet and inlcuding removing old unserviceable item complete all as specified and directed Make :- Havells/Finolex/Plaza
Supply and fix copper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade, 3 core ;2.5 sqmm and including connection to geyser and plug outlet and inlcuding removing old unserviceable item complete all as specified and directed Make :- Havells/Finolex/Plaza
Supply and fix non metallic rigid PVC junction boxes 1 to 4 way 32 mm dia, concealed in wall/ceilling for TV/Telephone cable all as specified and directed
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
Installation of 10 KVA UPS at air store building , provission of UPS charging conection of 24 Hrs and output supply is connected to DB complete all as specified and as directed by engineer -in - charge. Note :-requrement of wiring is measerd and paid separeatly under relivent items.
Dismantling carefully the existing split type AC (indoor & outdoor unit) 1.5/2.0 TR capacity from its position, keep in safe custody and refixing with new bracket and in serviceable condition after renovation of bldg, incl gas filling complete all as directed. (Note :- After taking down will be in contractor costudy to keep in safe condition)
S & F in repairs copper pipe for discharge 5/8'' & 3/8" dia complete for split Acs all as directed.
S & F in repairs copper pipe for suction 1/2'' & 1/4" dia complete for split Acs all as directed.
S & F in repairs Energy efficient LED street Light Luminaire 90 unsheathed wire multistranded from LT over head line to the connector of fitting, connection wires not to be less than 2.5 metre in length duly run through GI bracket complete all as specified and directed by Engr-in-charge.
S & F in repairs for Street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc.
Taking down of existing UNSV flood light fitting of any type and S&F LED flood light fittings 180 Watts incl fixing arrangement incl connections with 3 run of 2.5 sqmm aluminium unsheathed wire multistranded, necessory connections complete all as specified and as directed.Make : Bajaj or equivalent in Philips/CG/Shakti
Sch 'A' Part VII : External Water Supply
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all ccessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and as directed by Engr-in-Charge
Supply and lay pipe galvanized, “'medium grade”, including fittings, 20 mm dia complete all as specified and as directed.
Supply and fix Valve, stop, ,20 mm dia fancy type, chromium plated complete all as specified and as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings 15 mm (1/2”) dia. complete all as specified and as directed.
Sch 'A' Part VIII: FLAME PROOF LIGHT AND FAN
M & L for Point wiring with 1.5 sqmm (nominal area ) PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with stranded copper conductor in and incl stove enamelled steel concealed conduit (medium grade) and conduit accessories along with continuous earth wire 1.5 sqmm PVC insulated and unsheathed single core FRLS cable 1100 volts grade stranded copper conductor and connected to common earth dolly, with 1.6 mm thick cadmium plated sunk MS pressed steel terminal box for one flame proof light point controlled by one flame proof swicth.
M & L for Point wiring with 2.5 sqmm (nominal area ) PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with stranded copper conductor in and incl stove enamelled steel concealed conduit (medium grade) and conduit accessories along with continuous earth wire 2.5 sqmm PVC insulated and unsheathed single core FRLS cable 1100 volts grade stranded copper conductor and connected to common earth dolly, with 1.6 mm thick cadmium plated sunk MS pressed steel terminal box for one flame proof light point controlled by one flame proof swicth.
M & L for Cutting chases, pinning in, making good to facings where required in stone concrete block or slab walls and pointing in cement mortar 1:3 to ends or edges of landings, steps, sunsheds, shelves, lintels etc and cutting chases for reqd size concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete as specified & directed
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V all as specified.
S & F Flame proof exhaust fans AC single phase 230/240 V of size 305 mm sweep including necessary wall opening and fixing arrangement all as specified.
S & F Flame proof Louvers suitable for 305 mm exhaust fan all as specified.
S & F Flame Proof T /L fittings 4' Long 40 Watt single flurescent fixture in aluminium alloy LM6 with wire guard
S & F Flame Proof Celing Fan 1200 MM Sweep
S & F Flame Proof Celing Fan Regulator
S & F Flame Proof three Phase and neutral plug and socket 16 Amps capacity
Taking down old serviceable / unseviceable flame proof light and servieable lights refixing the new location all as specified and as directed by Engr-in- charge.
Taking down old serviceable / unseviceable flame proof exhaust fan and servieable exhaust fan refixing the new location all as specified and as directed by Engr-in- charge.
Taking down old serviceable / unseviceable flame proof ceiling fan and servieable ceiling fan refixing the new location all as specified and as directed by Engr-in- charge.
Sch 'A' Part IX Excavation and Earth Work
Excavation in trenches n. exc 1.5 M wide & n. exc 1.5 M in depth for foundation in soft/disintegrated rock and getting out complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n. exc 1.5 M wide & n. exc 1.5 M in depth for foundation in hard/dense soil and getting out complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25 Cm thick in hard/dense soil complete all as specified and as directed
Removal of excavated rock/soil to a distance n. exc 50M and deposited where directed at a level n. exc 1.5 M above the starting point.
Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge.
Shree Ayyappa Engineering
M/s J.D. DESAI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .