| 1.00Inspection & rectification of Sifang make SAS installed at 220 KV Sub-station Mallawan. The following works are including for healthy SCADA communications:- | ||||||
| 1.01Replacement of defective armored optical fiber cable it if required anywhere in the ring. | ||||||
| 1.02Replacing the defective FO multimode ST-ST port patchcord. | ||||||
| 1.03Checking & rectifying the healthiness of LIU sandits Communications port. | ||||||
| 1.04Checking & rectifying the healthiness of IBC 61850-7 ethemet switches. | ||||||
| 1.05Replacing of defective CAT-5/LAN cable and checking its healthiness. | ||||||
| 1.06Rectifying communication healthiness MOD bus RTU of various MFM meters. | ||||||
| 1.07Rectifying & checking healthiness of GPS systemandits synchronization with all relays. | ||||||
| 1.08Checking of healthiness of all protection relays. | ||||||
| 1.09Re-installation of old backup to SCADA communication to SCADA. | ||||||
Tender Value
Refer Docs
EMD Value
₹3,000
Closing Date
23 Mar 2026, 6:00 pmClosed
SE ETC Shahjahanpur
Electy Trans Circle Shahjahanpur
Work
2026_UPTCL_1126618_1
88 ETC(S)/2025-26
Open Tender
Electrical Works
Fixed-rate
60 days
Hardoi
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No. 0423002100107147 IFSC Code No. PUNB0042300
₹3,000
18 Jun 2026
17 Mar 2026
24 Mar 2026
17 Mar 2026
23 Mar 2026
17 Mar 2026
17 Mar 2026 - 23 Mar 2026
Inspection & rectification of Sifang make SAS installed at 220 KV Sub-station Mallawan. The following works are including for healthy SCADA communications:-
Replacement of defective armored optical fiber cable it if required anywhere in the ring.
Replacing the defective FO multimode ST-ST port patchcord.
Checking & rectifying the healthiness of LIU sandits Communications port.
Checking & rectifying the healthiness of IBC 61850-7 ethemet switches.
Replacing of defective CAT-5/LAN cable and checking its healthiness.
Rectifying communication healthiness MOD bus RTU of various MFM meters.
Rectifying & checking healthiness of GPS systemandits synchronization with all relays.
Checking of healthiness of all protection relays.
Re-installation of old backup to SCADA communication to SCADA.
Checking of all required event, alarm, numerical dates, status and Signals to SCADA from various bays and feeders.
Checking the SLD of S/S SCADA HMI
Checking of all required operations of equipment of SCADA.
Configuration of ethernet switches/modems/RTU etc. if required.
Installation of new window for Sifang automation software instand by PC andre-installingthe oldbackupofHMI-2 making both HMI-Iin all respect at the time of rectification all required material and computer parts shall be arranged by contractor.
Supply:-
Fiber optical multimode patch card for ST-ST port (each 5 meters)
Fiber optical multimode patch card for LC-ST ports (each 10 meters)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.15 MB
BOQ_2101009.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .