Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹22.6 L+₹3.2 L (16.8%)Rejected-Finance | L2 | Rejected-Finance Quoted rate higher than L1 Bidder | |
| 3 | L3₹23.2 L+₹3.9 L (20.3%)Rejected-Finance RONALDSAY ROAD JOYMAGAR BUS STAND AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | L3 | Rejected-Finance Quoted rate higher than L1 Bidder | |
| 4 | L4₹23.5 L+₹4.2 L (21.5%)Rejected-Finance | L4 | Rejected-Finance Quoted rate higher than L1 Bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical NIT criteria not fulfilled |
Tender Value
₹20.7 L
EMD Value
₹41,400
Closing Date
9 Jun 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 137 WE PIN 914 137 C O 99 APO
REPAIR MAINTENANCE OF TRANSFORMER AND HT DISTRIBUTION SYSTEM AT MASIMPUR MILITARY STATION UNDER GE SILCHAR
2020_MES_336765_2
8426/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MASIMPUR
Class E Category b ii
2 documents required · 2 mandatory
₹500
GE SILCHAR
₹41,400
Yes
31 Jul 2020
26 May 2020
11 Jun 2020
26 May 2020
9 Jun 2020
26 May 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth foundation of poles, cables etc not exceeding 10 sqm on plan area and getting out in soft / loose soil complete all as specified and as directed.
All as per item No 1.00 here-in-before but depth exc 1.50m and not exc 3.0m.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed .
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed. (Note: Punned thickness shall be measured for payment purpose)
Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
Taking down existing electric pole any type or size as per existing including demolition of existing concrete for pole foundation complete all as specified and as directed.
Supply and fixing steel tubular swaged pole, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, including painting of red & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and as directed. (Note: Excavation and earth work and PCC shall be measured and paid separately under respective items)
Dismantling of corroded / rusted / defective cross arms of mild steel channel / angle of any section complete all as specified and directed.
Material and labour for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and as directed.
Refixing only Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and as directed. (Items received from Item No. 9 shall be re-used)
Dismantling of old unserviceable insulator, any type / size complete all as specified and directed.
Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed. Make: Jayashree/BHEL/ Mysore/ Rastriya.
Supply and fixing Disc type insulator, porcelain, vitreous, 145 mm high and 255 mm dia ball and socket type, white, brown or green single disc assembly including nuts, bolts as requirred for 11000 volts grade confirming to relevant IS complete all as specified and as directed. Make: Jayashree/BHEL/ Mysore/ Rastriya.
Re- fixing Pin type insulator, complete all as specified and as directed. (Note: Insulator received from item No. 12 shall be re-used)
Re- fixing Disc type insulator, complete all as specified and as directed. (Note: Insulator received from item No. 12 shall be re-used)
Dismantling of old unserviceable damaged stay assembly embedded in concrete including demolition of PCC complete all as specified and directed.
Supply and fixing stay assembly with using 16 mm diameter of stay rod complete with accessories as shown in electrical plate No. 1 all as specified and directed. (Note: loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately)
Supply and fixing galvanised stay strand, 7/3.15 mm complete all as specified and directed.
Supply and fixing cradle guard hexagonal / rectangular fabricated with galvanised steel wire 4 mm dia on road crossing and streching the same with LT / HT overhead lines and binding the conductor with GI binding wire of suitable size including taking down old unserviceable cradle guard complete all as specified and as directed.
Dismantling old unserviceable air break gang operated switches vertical / horizontal mounted including insulators and operating mechanism complete all as specified and directed.
Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, with 9 insulator of rating upto 200 Amps complete all as specified and as directed. Make: Pactil/BHEL/Jaypuria Brothers
Taking down of HT 11 KV cable after disconnecting from both ends, any size complete all as specified and directed.
Supplying, Laying connecting & testing XLPE insulated, PVC sheathed, armoured HT electric power UG cable (heavy duty with stranded aluminum conductor) of size 95 Sqmm, 3 core, 11000 Volts(Earthed) grade, confirming to IS-7098 (Part-II) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item.
Supply and laying unreinforced precast concrete cable cover, class HV type 1, flat, size 300mm x 180mm x 40mm laid flat and dry in trenches over the cable complete all as specified and directed.
Supply and fixing in replacement for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and as directed. Make: Raycem/ Denson/ M-Seal/3M.
Supply and fixing in replacement for LT 11 KV grade heat shrinkable jointing kit straight through type complete with jointing material and accessories suitable for 3 core PVC insulated, sheathed aluminium conductor cable of size 95 sqmm complete all as specified and as directed. Make: Raychem/ Denson/ M-Seal/3M.
Repair to HT 11 KV 4 pole structure of 11 metre height steel / RCC poles including replacement of all perished ACSR conductor (weasel) of horizontal bus bar and down conductor for 4 Nos / 2 Nos GOD systemon structure, jumpering and binding with alluminium conductor to the post insulators / pin insulators and providing PVC sleeves to the down conductor with colour code R, Y & B, replacing all rusted nuts and bolts complete all as specified and directed.
Repair to HT 11 KV 2 pole / 3 pole structure of 11 metre height steel / RCC poles including replacement of all perished ACSR conductor (weasel) of horizontal bus bar and down conductor for 4 Nos / 2 Nos DOD systemon structure, jumpering and binding with alluminium conductor to the post insulators / pin insulators and providing PVC sleeves to the down conductor with colour code R, Y & B, replacing all rusted nuts and bolts complete all as specified and directed.
Supply, install, testing and commissioning of lightening arrestor expulsion type complete with all fitings, transmission class, discharge capacity 65 KA suitable for working voltage of 11000 Volts including all necessary fittings all as per IS-3070 Part-III and IEC 1994 including dismantling of old unserviceable one complete all as specified and as directed. Make: Alpro/Areva/Oblum/Rastriya/Raychem/Bhal /ABB
Supply and laying 80 mm bore dia GI tubing, light grade with all fittings under trenches for passing of cable or fixed to wall by necessary clamps / nuts / bolts etc as requirred including taking down old unserviceable GI pipe complete all as specified and as directed
Disconnecting the HT / LT connection of existing outdoor type transformer of any capacity mounted on plinth and transport to factory for carrying out repairs, opening the transformer, lifting core and reassembling after rewinding and overhauling including dehydration of transformer oil complete and refixing the same after repair / testing at its original position or position as indicated and connecting to HT / LT cable properly including testing of oil before and after complete all as specified and directed. (Note: The cost of Crane charges for loading / unloading of transformer at site and factory premises including transportation, labour charges for loading / unloading from site to factory and back are deemed to be included in the quoted rate.)
Shifting of transformer carefully from the existing pole / plinth / store yard to another location under GE Silchar including including transportation and connecting / disconnecting from HT / LT side complete all as specified and directed.
Supply and fixing as in replacement of HT bushing suitable for outdoor type upto 200 KVA Transformer Conforming to IS-334 complete with nuts, bolts, bruss studs and gasket of synthetic rubber bounded cork sheet for working pressure 11 KV complete all as specified and directed.
Supply and fixing as in replacement of HT bushing suitable for outdoor type from 250 KVA upto 500 KVA Transformer Conforming to IS-334 complete with nuts, bolts, bruss studs and gasket of synthetic rubber bounded cork sheet for working pressure 11 KV complete all as specified and directed.
Supply and fixing as in replacement of HT brass stud suitable for upto 200 KVA transformers complete all as specified and directed.
Supply and fixing as in replacement of HT brass stud suitable for from 250 KVA upto 500 KVA transformers complete all as specified and directed.
Supply and fixing as in replacement of LT bushing suitable for outdoor type from upto 200 KVA Transformer Conforming to IS-334 complete with nuts, bolts, brass studs and gasket of synthetic rubber bounded cork sheet for working pressure 0.433 KV complete all as specified and directed.
Supply and fixing as in replacement of LT bushing suitable for outdoor type from 250 KVA upto 500 KVA Transformer Conforming to IS-334 complete with nuts, bolts, brass studs and gasket of synthetic rubber bounded cork sheet for working pressure 0.433 KV complete all as specified and directed.
Supply and fixing as in replacement of LT brass stud suitable for upto 200 KVA transformers complete all as specified and directed.
Supply and fixing as in replacement of HT brass stud suitable for from 250 KVA upto 500 KVA transformers complete all as specified and directed.
Material and labour in repair for rewinding the unserviceable burnt out copper winding wire for HT side with copper conductor super enamelled / DPC impregnated paper insulated as per existing gauge and turns with necessary insulating materials, varnishing, heating backing complete all as specified and directed.
Material and labour in repair for rewinding the unserviceable burnt out alluminium winding wire for HT side with alluminium conductor insulated as per existing gauge and turns with necessary insulating materials, varnishing, heating backing complete all as specified and directed.
Supply and fixing as in repair old unserviceable drain plug of suitable size for existing transformer complete all as specified and directed.
Supply only new transformer oil of dielectric strength not less than 50 KV and conforming to IS-335 of 1993 for filling / topping up of transformer up to desired level complete all as specified and directed. (Make: Power link / Svita power oil or equivalent as approved by GE.)
Dehydration and filtration of existing transformer / Servo stabilizer oil at different location with filtration machine and heating system to get the minimum di-electric strength of oil 40 KV at 2.5 mm gap minimum without disturbing the power supply system and refilling / topping up / replacement of unserviceable transformer oil conforming IS 335-1993 complete all as specified and directed. (Note: (a) Transformer oil required extra for refilling / topping up shall be measured and paid separately under the relevant item of this schedule. (b) Cost for testing of oil including T&P shall deemed to be included in the quoted rate.)
Taking out unserviceable silica gel breather of transformer and providing new silica gel breather with all accessories filled with silica gel suitable for transformer of 250 KVA capacity of same specification complete all as specified and directed.
Taking out unserviceable silica gel breather of transformer and providing new silica gel breather with all accessories filled with silica gel suitable for transformer of 315 KVA capacity of same specification complete all as specified and directed.
Taking out unserviceable silica gel breather of transformer and providing new silica gel breather with all accessories filled with silica gel suitable for transformer of 2.5 MVA capacity of same specification complete all as specified and directed.
Taking out unserviceable silica gel breather of transformer and providing new silica gel breather with all accessories filled with silica gel suitable for transformer of 1.60 MVA capacity of same specification complete all as specified and directed.
Taking out unserviceable cork sheet gasklet of any description of transformer and providing new cork sheet gasket of 5 mm thick best quality complete all as specified and directed.
Material and labour for spray painting of transformer with two coats of Duco paint (grey0 after cleaning through and preparation of surface of transformer to receive painting for transformer of capacity upto 315 KVA including writing of MES No. / SM No. complete all as specified and directed.
Material and labour for 100 mm thick hardcore of broken stone / boulder, gauge n.exc. 63 mm, spreading, levelling and compacting to a true surface complete all as specified and directed.
Material and labour for repair / overhauling / servicing and testing of 33KV & 11 KV VCB at site including removing incomming and outgoing cable connection, moving and fixed contacts, cleaning the parts with CTC, servicing contactors, checking the of VCB panel healthiness of fault tripping system by using secondary injection method and checking breaker closing coils improving the insulation resistance and re-assembling the same after replacement of unserviceable spare parts and making the VCB fully serviceable condition to the entire satisfaction of GE complete all as specified and directed. (Note: (i) Spare parts shall be measured and paid in relevant items. (ii) Rapair work shall be carried out by authorised service engineer. and the cost for bringing service engineer at site shall be borne by the contractor)
Supply only spring charging motor suitable for 11000 volts indoor type VCB complete all as specified and as directed. (Make: Crompton Greaves or as approved by GE.)
Supply only trip coil suitable for 11000 volts indoor type VCB complete all as specified and as directed. (Make: Crompton Greaves or as approved by GE.)
Supply only close coil suitable for 11000 volts indoor type VCB complete all as specified and as directed. (Make: Crompton Greaves or as approved by GE.)
Supply only master trip relay, 110 Volt suitable for 11000 volts indoor type VCB complete all as specified and as directed.
Supply only master trip relay, 110 Volt suitable for 33000 volts indoor type VCB complete all as specified and as directed.
Supply only HRC fuse grip as per existing sample and with HRC fuses from 2 to 16 Amp complete all as specified and as directed.
Supply only Epoxy resin cast CT having ratio 100.5+5A.15VA CL-5P10 suitable for 11000 volts indoor type VCB complete all as specified and as directed. (Make: Crompton Greaves or as approved by GE.)
Supply only Current transformer having ratio 100/5 and 50/5 suitable for 11000 volts outdoor type VCB, insulation level 70/70 KV complete all as specified and as directed. (Make: KAPA Electric or as approved by GE.)
Supply only digital voltmeter suitable for 11 KV VCB complete all as specified and as directed. (Make: MECO Electric or as approved by GE.)
Supply only digital Ammeter with CT suitable for 11 KV VCB complete all as specified and as directed. (Make: MECO Electric or as approved by GE.)
Supply only high grade rubberised hand gloves for 33 KV HT line complete all as specified and as directed.
Supply only HT tape complete all as specified and as directed.
Supply only fix vaccume interrupter suitable for 11000 volts indoor type VCB complete all as specified and as directed. (Make: Crompton Greaves or as approved by GE.)
Supply only motor charging bearing suitable for 11000 volts indoor type VCB complete all as specified and as directed. (Make: Crompton Greaves or as approved by GE.)
Supply only spring charging motor suitable for 33000 volts indoor type VCB complete all as specified and as directed. (Make: Crompton Greaves or as approved by GE.)
Supply only fix vaccume interrupter suitable for 33000 volts indoor type VCB complete all as specified and as directed. (Make: Crompton Greaves or as approved by GE.)
Material and labour for trimming of various sizes of tree branches which are touching / close to HT over head line at various place and clear the HT over head line upto 3.00 metre from conductor close to tree along pole to pole complete all as specified and directed. (Note: (a) All the safety equipments, cutting materials, ladder etc requirred for the work to be provided by the contractor. (b) Pole to pole distance to be measured in span. (c) The cutting shall be done two times during the contract period as requirred basis.)
Clearing of the shrubs, vegetation grass, bushes, plants and saplings grown below HT line around the stay and all substations in the area and clearing the rubbish materials and dumping at places as directed complete all as specified and directed.
Material and labour for pouring distilled water for battery bank of 33 / 11 KV MRS Sub station complete all as specified and directed.
Dismantling of existing RCC 11 KV two pole structure including insulators, GOD, metering devices,ACSR etc including breaking of PCC foundation and removing to storeyard complete all as specified and directed. (Note: (i) All metering devices / CT / PT shall be deposited at MES storeyard. (ii) Due care shall be taken to avoid any damage to existing electric supply system.)
Dismantling of existing steel tubular / rail type 11 KV two pole structure including insulators, GOD, metering devices,ACSR etc including breaking of PCC foundation and removing to storeyard complete all as specified and directed. (Note: (i) All metering devices / CT / PT shall be deposited at MES storeyard. (ii) Due care shall be taken to avoid any damage to existing electric supply system.)
NAGALAND AGENCIES CO
M/S NIYATI NETWORK
APPLE CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .