Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC 620 DIAMOND HARBOUR ROAD BEHALA INDUSTRIAL ESTATE PLOT NO F A KOLKATA 34 | KOLKATA | WEST BENGAL | L1 | Accepted-AOC Accepted as L1. | |
| 2 | L2₹14.4 L+₹1.4 L (10.8%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L2 | Rejected-Finance Quoted higher rate than L1. | |
| 3 | Rejected-Technical | - | Rejected-Technical Technically disqualified. | |
| 4 | Rejected-Technical | - | Rejected-Technical Technically disqualified. | |
| 5 | Rejected-Technical | - | Rejected-Technical Technically disqualified. |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
16 Nov 2022, 5:00 pmClosed
The Divisional Manager, KFCD, WBFDCL
Office of The WBFDCL, Kolkata Forest Corporation Division, Aranya Bikash, Salt Lake City, Kolkata - 700 106.
Design, fabrication, shop testing, supply, installation, site testing, commissioning and 3 years AMC of HVAC System at Heritage Cafe, Alipore Zoo, Kolkata.
2022_FDCL_418546_1
89/29-18/2022-23 (3rd Call)
Open Tender
Miscellaneous Goods
Item Rate
20 days
Heritage Cafe, Alipore Zoo
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹26,000
Yes
5 Apr 2023
2 Nov 2022
18 Nov 2022
2 Nov 2022
16 Nov 2022
2 Nov 2022
Amount
VRF / VRV Out Door Units
14 HP Side Discharge Type ODU
Floor Standing VRF Indoor Unit: Capacity - 2.0TR
Wireless Remote
Inter Connecting Y - Joint / Refnets
REFRIGERANT PIPING
Supply, installation, testing and commissioning of copper refrigerant piping for the above VRF indoor and outdoor units, copper piping shall be properly supported and it shall include the cost of all the fitting, insulation and all required fittings, joints etc.. The insulation shall be closed cell nitrile rubber tubular insulation (19/13 mm thick). Nominal diametres of pipes in mm as per final design. (Rate will be incuding of all taxes)
CONDENSATE DRAIN PIPING Supply, Installation, Testing and Commissioning of insulated PVC condensate drain water piping with bends reducers tees, supports etc. The insulation shall be nitrile rubber as per drawings. (Rate will be incuding of all taxes)
25 mm (with 6mm insulation)
32 mm (with 6mm insulation)
Supply, installation, testing & commissioning of CU Flexible control cable 3C X 1.5 Sqmm.
Miscellaneous Items:
Supply, testing and commissioning of above systems including topping refrigerent gas as per site requirements. Refrigerant shall be environmental friendly R410A gas. (Rate will be incuding of all taxes)
Supply and Testing of N2 Pressure Gas Charge with proper flushing and leack test of all ref-copper pipe including joints. (Rate will be incuding of all taxes)
Supply, erection, testing & commissioning of electrical power cabling (with copper core) and distribution works. (Rate will be incuding of all taxes)
Comprehensive Annual Maintenance Contract. (AMC will include = Service Charge + Visit Charge + Spare's cost, complete) Contractor have to maintain the installed air-conditioning system on their own for 3 years. During the AMC period contractor will be solely resposible for proper functioning of the entire air-conditioning system. If any problem arises they should be capable to resolve the issue/issues within 16 hours from the time of raising any such complaint/complaints. AMC will be applicable after completion of 1st year of comprehensive brand warranty.
Lyric International
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .