| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC Lowest Bidder. | |
| 2 | L2₹31.4 L+₹3.4 L (12.1%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹31.7 L+₹3.7 L (13.2%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹35.5 L+₹7.5 L (26.8%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹36.0 L+₹8.0 L (28.7%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR/REPLACEMENT OF E/M PETTY REPAIRS WORKS AT VARIOUS LOCATION MD ACCN AND OTM ACCN AT KHYBER LINE, CAMS. 1 CBPO, IML, 180 MAHIPALPUR, 35 INF BDE AND 227 FD WKSP UNDER GE (SOUTH) DELHI CANTT-10
2024_MES_660604_1
GE/DS-41/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹90,000
25 Sept 2024
19 Jun 2024
25 Jul 2024
19 Jun 2024
18 Jul 2024
4 Jul 2024
Amount
Attending complaints between 0845 Hrs to 1645 Hrs for checking the existing electrical items for continuous electric supply including carrying out minor repair etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. Attending minor repair such as testing, electric connections, fittings, nut, bolts and screws etc to ceiling fan, exhaust fan at its initial position (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electrical system of main building/block for uninterrupted electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and as directed.
All as per Srl item No. 1 above, but attending complaints in between 1645 hrs to 2345 Hrs.
All as per Srl item No. 1 above, but attending complaints in between 2345 hrs to 0845 Hrs.
Notes for Srl item Nos.01, 02 & 2.1 :- 1. The site for attending complaints are 180 Mahipalpur, 35 brigade,227 Field works shop, Signal company,CAMS,1CBPO, IML, khyber line, BSO office and Contractor shall provide adequate Nos of tradesmen (electrician) alongwith adequate Nos of helper to attend the complaints all the above areas in all working days including holiday and sunday. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 4. A recovery of Rs. 500/- for not attending the complaint upto 04 hours and after 04 hours Rs. 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register , gate pass & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7.The above tradesmen shall not be utilized for the items entered here-in-after as taking down, S&F, M&L, S&F in repairs M&L in repairs etc. and the rate quoted by tenderer are deemed to be included for the same. 8. The store reuired for attending the complaints shall be provided against "Supply Only" items here-in-after.
Supply only switch piano flush type 6 Amps SP one way complete all as specified and as directed.
Supply only switch piano flush type 6 Amps SP 2-way complete all as specified and as directed.
Supply only bell push, flush type 6 Amps complete all as specified and as directed.
Supply only socket outlet 6 Amps flush type 3 pin complete all as specified and as directed.
Supply only switch piano type 16 Amps SP one way complete all as specified and as directed.
Supply only socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and as directed.
Supply only switch socket combination 2-in-1, 6 Amps with gang box flush type complete all as specified and as directed.
Supply only switch socket combination 2-in-1 6 & 16 Amps with gang box flush type complete all as specified and as directed.
Supply only switch socket combination 2-in-1, 6 Amps flush type complete all as specified and as directed.
Supply only switch socket combination 2-in-1 6 & 16 Amps flush type complete all as specified and as directed.
Supply only lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
Supply only switch modular type, 1Module, 6 Amps one way as per sample complete all as specified and as directed.
Supply only socket outlet modular type 2M, 2/3 pin, 6 Amp as per sample complete all as specified and as directed.
Supply only switch modular type 1M, 16 Amp as per sample complete all as specified and as directed.
Supply only socket Outlet modular type 2M combined shuttered, 5 pin 6/16 Amp as per sample complete all as specified and as directed.
Supply only electronic fan regulator, modular type 2M, 4 steps as per sample complete all as specified and as directed.
Supply only ceiling rose surface bakelite 65x25 mm two to three terminals complete all as specified and as directed.
Supply only plug top 15/16 Amps, complete all as specified and directed by Engr-in-Charge.
Supply only PRCD 16 AMP, 30 mA plug Top , complete all as specified and as directed.
Supply only fan regulator electronic, stepped type, Switch type, suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed.
Supply only Tee cover of suitable size as per existing complete all as specified and as directed.
Supply only bell Ding dong type 230 volts single phase complete all as specified and as directed.
Supply only ceiling fan capacitor of 2.5 mfd complete all as specified and as directed.
Supply only ceiling fan capacitor of 3.15 mfd complete all as specified and as directed.
Supply only MS fastner bolt 8 mm dia and upto 150 mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and as directed.
Supply only U clamp with rubber real for hanging ceiling fans of 1200/1400mm sweep as per sample complete all as specified and as directed.
Supply only PVC connection with brass nipple 15 mm x 600 mm long with ISI marked suitable for hot and cold water of 25/50 ltrs capacity of geyser connection with 2 Nos brass/CP nuts as per sample complete all as specified and as directed.
Supply only LED Batten T-5 fitting 20 watt LED White, indoor decorative pvc extruded T5 LED battern -integrated type complete including taking down of old unsv existing 36 Watt tube light fitting, complete all as specified and as directed.
Supply only LED Integrated Batten T-5 10 watt - 2 FT White, indoor decorative pvc extruded T-5 LED battern -integrated type complete with including flexible wire including taking down of old unsv existing 18 Watt tube light fitting complete all as specified and directed by Engr-in-Charge.
Supply only LED Integrated Batten T-5 05 watt - 1 FT White, indoor decorative pvc extruded T-5 LED battern -integrated type complete with including flexible wire including taking down of old unsv existing 18 Watt tube light fitting complete all as specified and as directed.
Supply only LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and as directed.
Supply only surface mounting round/square shaped LED downlighter with PDC pvc housing 12 Watt LED lamp type including taking down of old unsv existing CFL fitting any type from ceiling of stairs/common areas, complete all as specified and as directed.
Supply only wall light fixture any type with Wall mounting fitting City-4, Decorative wall light fixture made up of Polycarbonate, of B-22 base complete all as specified and as directed.
Supply only Recessed/surface mounting 36 watt 2' x 2' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and as directed.
Supply only Recessed/surface mounting 36 watt 4' x 1' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and as directed.
Supply only LED Building security light fitting 45 W on existing bracket in replacement of old unsv existing security light fitting any type complete all as specified and as directed.
S&F in replacement GI pipe's bracket suitable for fixing of bldg security LED light fitting of 45 Watts including grouting and fixing the same on wall for installation of light fitting with necessary clamps, nut, bolts & washer and painting by synthetic enameled good quality paint in white/grey colour over one coat of red oxide primer until unless smoothness of bracket complete all as specified and as directed. Note :- GI pipe should be 25 mm bore with medium grade and the same to be moulded in 45 degree angle at the 1 Mtr height to fix the building security light fitting.
S&F in repairs LED post top lantern fitting with die cast aluminium spigot, spun aluminum powder coated top cover Aluminum PDC heat sink opal PC diffuser clear acrylic IP-65 with 40 Watt power including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete including making a hole in pillar/wall with light grade GI pipe of suitable size for fixing the post top lanter fitting complete all as specified and as directed.
S&F in replacement of LED garden light (Bollard) fitting luminaires of 10 Watt in Mashroom Shape of 3000K with IP 65 complete with all accessories including necessary connection of suitable size wire complete all as specified and as directed.
Supply only LED bulb 12 Watt B-22 Cap, AC 230V, 50 Hz suitable for Batten Holder/wall light fittings in replacement of old unsv lights any type complete all as specified and as directed.
Supply only LED bulb 12 Watt rechargeable B-22 Cap, AC 230V, 50 Hz suitable for Batten Holder/wall light fittings in replacement of old unsv lights any type complete all as specified and as directed.
Supply only MCB SP 06 to 32 Amps 240 Volts, 10 KA, all as per site requirement and complete all as specified and directed by Engr-in-Charge.
Supply only MCB SPN 32 to 40 Amps, 240 Volts, 10 KA, all as per site requirement and complete all as specified and as directed.
Supply only MCB SPN 63 Amps, 240 Volts, 10 KA, all as per site requirement and complete all as specified and as directed.
Supply only MCB TPN 63 Amps 415 volts, 10 KA as per site requirement and as directed of approved make.
Supply only MCCB 4 pole 100 Amp 415 Volt, As per site requirement complete all as specified and as directed.
Supply only MCCB 4 pole 160 Amp 415 Volt, as per site requirement complete all as specified and as directed.
Supply only MCCB 4 pole 200 Amp 36 KA 415 Volts with breaking capacity 36 KA complete all as specified and as directed.
S&F in repairs distribution board V-TPN 4 way for fixing MCCB 200 Amps as incommer and MCBs as out goings with metal door and IP 43 Protections and connecting, in replacement complete all as specified and as directed.
S&F in repairs of sheet metal enclosures for DBs when MCBs to be used SPN-8 Way, 240V with busbar as per site requirement complete all as specified and directed by Engr-in-Charge.
Supply only Circuler PVC Sheet (8 inch x 5 inch) of 3 mm thick (including cutting for 1 nos 15 amps switch and 1 nos 15 amp socket ) including screws and cup washer complete all as specified and directed by Engr-in-Charge.
Supply only Celing fan round sheet 3 mm thick complete all as specified and directed by Engr-in-Charge.
Supply only PVC casing caping of size 20 x 12mm of ISI Mark or as per manufacturer design with all accessories for surface wiring complete all as specified and directed by Engr-in-Charge.
Supply only PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour complete all as specified and directed by Engr-in-Charge.
Supply only PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour complete all as specified and directed by Engr-in-Charge.
Supply only PVC insulated FRLS 3 core with stranded copper cable of size 2.5 Sqmm for any type of wiring as per site requirement and complete all as specified and directed by Engr-in-Charge.
Supply only PVC insulated FRLS 2 core with stranded copper cable of size 1.5 Sqmm for any type of wiring as per site requirement and complete all as specified and directed by Engr-in-Charge.
Supply only PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour complete all as specified and directed by Engr-in-Charge.
Supply only PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour complete all as specified and directed by Engr-in-Charge.
Supply only heating element of 1.5 KW including rubber washers (ISI marked) etc as per site requirement complete all as specified and directed by Engineer-in-Charge.
Supply only thermostat 9/11" (ISI Marked) for 25/35/50 Litres capacity Geyser as per sample complete all as specified and directed by Engineer-in-Charge
S&F in repairs Exhaust fan MS Louvers upto 450 mm Size, as per sample up to Third floor complete all as specified and as directed. Note:- The quoted rates are deemed to be included for necessary scaffolding required.
Supply only Electric BLDC fan controller PCB with short cuircuit protection power 440V suitable for onground BLDC ceiling fan 1200mm Sweep complete all as specified and as directed.
Supply only BLDC ceiling fans Motor with Remote control,1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor complete all as specified and as directed.
Supply only ceiling fan blades (Set of 3 ) suitable for BLDC Fan 1200/ 1400 mm sweep complete all as specified and as directed.
Supply only ceiling fan down rods suitable for BLDC Fan 1200/ 1400 mm sweep complete all as specified and as directed.
Supply only ceiling fan canopy suitable for BLDC Fan 1200/ 1400 mm sweep complete all as specified and as directed.
Supply only Exhaust fan motor Light duty Metal 300 mm Sweep, copper wound,complete all as specified and as directed.
Supply only Exhaust fan metal blades for 300 mm sweeep with Complete frame and all accessories complete all as specified and as directed.
Supply only Exhaust fan motor Light duty Metal 450 mm Sweep,copper wound complete with metal blades and all accessories complete all as specified and as directed.
Supply only Exhaust fan metal blades for 450 mm sweeep with Complete frame and all accessories complete all as specified and as directed.
Supply only PVC body Exhaust fan motor Light duty Metal 230/250 mm Sweep, copper wound complete all as specified and as directed.
Supply only Exhaust fan PVC blades for 230/250 mm sweeep with Complete frame and all accessories complete all as specified and as directed.
Supply only XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- ectional area 16 sq. mm 4 core complete all as specified and as directed.
Supply only XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- ectional area 16 sq. mm 2 core complete all as specified and as directed.
Supply only copper thimbles of size upto 25 sqmm complete all as specified and as directed.
Supply only pvc clamp suitable for LT cable up to size 25 sqmm complete all as specified and as directed.
Supply only brass machine screw size upto 4 inch complete all as specified and as directed.
Supply only single pole and neutral metal clad sheet metal enclosures with 2 pin and earth plug and socket complete with one no MCB SPN upto 32 Amps as per site requirment of existing type for AC's/Geyser complete all as specified and as directed.
Taking down copper point wiring (light, fan, socket or power and fitting) and making good disturbed surfaces of walls, floors etc.
M&L for point wiring complete, standard copper conductor 1.5 Sqmm nominal area PVC insulated FR-LS 1100 volts grade electrical cable in and including suitable size of concealed/surface PVC conduit/ casing caping medium grade and sunk in pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer complete with all accessories including 1.5 Sqmm standard copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified and as directed. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes. (a) One light / fan/bell point controlled by one switch SP, one way,
All as above Srl item No. 82 above but one 3 pin socket outlet 5/6 Amps on same board.
All as above Srl item No. 82 above but one socket outlet 5/6 Amps on independent boardwith cable 1.5 Sqmm for phase & neutral and for earth 1.5 sqmm.
All as above Srl item No.82 above but here-in-before one power socket 15/16 Amp with cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
S&F switch piano flush type 6 Amps SP one way complete all as specified and as directed.
S&F socket outlet 6 Amps flush type 3 pin complete all as specified and as directed.
S&F switch piano flush type 16 Amps SP one way complete all as specified and as directed.
S&F socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and as directed.
S&F in replacement of Sub Main wiring using single run PVC FR-LS grade Insulated unsheathed, multistrand copper conductor cable 2 runs of 6 Sqm for phase and neutral and 1 run of 6 Sqm for earth wire drawn through concealed PVC conduit wiring in wall not less than 32 mm dia with all fittings like tees, bends, junction/ terminal boxes etc as per site requirement and all as directed by Engr-in-charge. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in replacement of Sub Main wiring using single run PVC FR-LS grade Insulated unsheathed, multistrand copper conductor cable 2 runs of 04 Sqm for phase and neutral and 1 run of 04 Sqm for earth wire drawn through concealed PVC conduit wiring in wall not less than 20 mm dia with all fittings like tees, bends, junction/ terminal boxes etc as per site requirement and all as directed by Engr-in-charge. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Note :- The contract sum shall be after deducting the amount of credit shown in Sch of Credit of this tender
SABHARWAL CONSTRUCTION CO.
verma enterprises
Chaudhary Constructions
J V ENGINEERS / JAI SINGH
P R Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .