Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹20.3 L+₹33,975.40 (1.70%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹20.9 L+₹90,323.60 (4.52%)Rejected-Finance 4 KRISHNANJALI BUILDING TAI PINGALE CHOWK DOMBIVALI EAST | DOMBIVALI | THANE | MAHARASHTRA | 421201 | L3 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
28 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
PROVN OF SPECIAL REPAIR REV AND MINOR EM WORKS AT MATHURA UNDER GE (EAST) MATHURA
2023_MES_588008_1
8200-1333/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE EAST MATHURA
₹44,000
9 May 2023
1 Apr 2023
1 May 2023
1 Apr 2023
28 Apr 2023
15 Apr 2023
1 Apr 2023 - 21 Apr 2023
Amount
Supply, install, testing & commissioning of hi wall split type Air conditioner indoor/outdoor unit (compressor) complete 2TR capacity with cordless remote controler unit and with inbuilt air Ioniser and Plasma filter 5 star rated suitable for working on 230 Volts, single phase, 50 Hz supply, complete including cutting/drilling in wall for inserting cooling pipe & drain pipe including providing stand for outdoor unit and making good disturbed surface of walls to match the existing surface etc complete all as specified and directed.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and as directed.
Supply & Fixing single pole and neutral sheet metal enclosures with a 2 pin and earth plug and socket with 20 Amps MCB including making all connections complete all as specified and as directed.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade 10 Sqmm 4 core cable with aluminium conductor laid in trenches/pipes, fixed to poles/walls, fixing with suitable saddle/clamps complete all as specified and as directed.
Supply & Fixing Powder coated CRCA mild steel sheet MCB distrbution board, IP-43 IK-09 protection, double door recess mounted, triple pole and neutral 4 way with 200 Amps rated copper bus bar complete all as specified and as directed.
Supply & Fixing Sub main wiring with two run of single core 4 Sqmm cable PVC insulated unsheathed (FRLS) cable with multistrandard copper conductor, 1100 votls grade drawn through and including concealed PVC conduit 25 mm dia medium duty including all its acessories such as Tee, bend, elbow etc ISI marked with and concealed in wall/roof including necessary cutting/chase and making good distured surface including 4 Sqmm PVC insulated unsheathed stranded (FRLS) cable for earth wire complete all as specified and as directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire & 25mm PVC Conduit shall be measured as one unit length.
Excavation in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of underground cables, erection of poles and for stays in any type of soil and getting out complete all as specified and as directed.
Returning, filling in excavated soil including spreading, levelling,watering and well ramming in layers not exceeding 25 cm thick each after cables have been laid and tested complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material & Labour for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and as directed. Note : For payment punned depth shall be measured.
Material & Labour for laying unreinforced precast concrete cable cable cover class LV type 1, flat size 250mmx150mmx40mm complete all as specified and as directed.
Supply & Fixing isolator DP 40 Amps, 240 volt C curve MCB repturing capacity 10 KA complete all as specified and as directed.
Supply & Fixing MCB SP 6 - 32 Amps, 'C' series, breaking capacity 10KA, 240V complete all as specified and as directed.
Supply, installation, Commissioning of water cooler partially stainless steel, electric driven single phase having approx storage capacity 80 ltrs and nominal cooling capacity 40 ltrs per hours complete all as specified and as directed.
Supply and fixing, installing, testing and commissining Reverse Osmosis water purifier with TDS Adjester auto shut off stainless body of Plant of out put capacity of 50 Litres per hour (RO,UV,UF), 230 Volt AC, including filter removes ions, unwanted molecules and larger particles from drinking water using a partially permeable membrane complete all as specified and as directed.
Material & Labour for point wiring for 5/15 Amp socket outlet on independent board with PVC insulated unsheathed 4 Sqmm PVC insulated, unsheathed single core multistranded copper conductor cable FRLS 1100 Volt grade drawn through and including rigid PVC conduits in walls/ceiling including all connected accessories complete concealed in wall/roof including cutting & chases (making good all to the disturbed surfaces as per existing) including factory made sunk cast iron/pressed steel/terminal boxed for mounting flush type switches/sockets etc with 3mm thick phenolic laminated sheet covers alongwith provision of 2.5 sqmm insulated multistranded copper conductor cable FRLS 1100 volt grade as earth continuity wire complete all as specified and as directed.
Supply and Fixing switch socket combination multi purpose 5/16 Amps 5 in 1 flush type 230 volts AC complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated, unsheathed, multistranded, 1100 Volts grade single core copper conductor cable FRLS, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall/roof including cutting & chases (making good all to the disturbed surfaces as per existing) including factory made sunk cast iron/pressed steel/terminal boxed for mounting flush type switches/sockets etc with 3mm thick phenolic laminated sheet covers and including contineous earth wire of PVC insulated (FRLS) multistandered copper conductor cable of 1.5 Sqmm size in green colour complete all as specified for followings:-
One 5 pin 5 Amps socket point controlled by one way switch on independent board complete all as specified and as directed.
S&F Switch socket combination 2-in-1, 5 Amps flush type complete all as specified and as directed.
M&L for laying 15mm bore mild steel tubing, medium grade galvanised with all fittings fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
All as per Serial item No 21.00 here-in-before but 25mm bore pipe complete all as specified and as directed.
S&F stop valve/Angle cock cast copper chromium plated with crutch or butterfly handle, screwed both ends for 15mm dia bore iron pipe or unions and fixed complete all as specified and as directed.
S&F rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) white colour triple layer 1000 Liters capacity hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for 20mm bore iron pipe or union complete all as specified and as directed.
S&F ceiling fans copper winding with blades Aerodynamically design blades made of compounded ABS to gives less air friction for silent operation complete with down rod, and accessories, 230 volt, 1200mm sweep min air delivery 210 CFM with service value 6.00 BEE Five Star rated with brushless direct current motors (BLDC) complete all as specified and as directed.
Supply and fixing exhaust fan steel body AC single phase, 230 volt of size 300mm sweep with blades, frame and louvers including connecting up with twin core twisted flexible copper conductor cable of suitable size 0.75 sqmm complete all as specified and as directed.
Supply, installing, testing and commissioning of pressure booster pump single phase, capacity 1 HP, 220-240 volt, 50 Hz head range upto 50 M, discharge range upto 80 LPM, type of insulation B class including protection against over current, low voltage with all required accessories complete all as specified and as directed.
Supply and fixing aluminium flat cable of size 4.0 sqmm 3 core from pump/motor to MCB/DB point in and including 20mm dia rigid PVC conduit pipe and accessories complete all as specified and as directed. Note : One run of cable & PVC pipe and accessories shall be measured as one RM.
Ms Kamal Kant Agarwal
subhash construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .