CWE Bathinda
HQ CWE Bathinda, Bathinda Military Station
REPAIR MAINTENANCE OF VOLTAGE STABILIZER/ UPS ETC AND ALLIED WORK AT BATHINDA MIL STN
2021_MES_477038_1
CWE BTD 8221/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Bathinda
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (U) Bathinda
₹14,500
Yes
23 Oct 2021
22 Sept 2021
20 Oct 2021
22 Sept 2021
18 Oct 2021
6 Oct 2021
22 Sept 2021 - 6 Oct 2021
60 days
Amount
M & L servicing and cleaning of oil cooled servo voltage stabilizer of capacity 10 to 20 KVA, 3 Phase including by transporting to workshop if necessary, carefully lifting of core from the tank by opening cover, cleaning of tank, removing of sediments, cleaning of coils/ electrical connections, filtration of transformer oil , fixing the core back in the tank, making electrical connections by replacing the consumable spares such as gaskets, rubber oil seals complete etc including electric connection and testing on load complete all as specified
All as per item No 1 here in before but capacity 50 KVA.
All as per item No 1 here in before but capacity 100 KVA.
All as per item No 1 here in before but capacity 250/300 KVA. Note for ser item No. 1 to 4:- (i) Spare parts required to make serviceable of above oil cooled servo voltage stabilizer shall be measured and paid separately under relevant item here-in-after. (ii) Rewinding of barrier assembly and transformer assembly will be measured and paid separately.
S & F in replacement voltmeter ( digital) complete all as specified
S & F in replacement Ammeter with CT ( digital) complete all as specified
S & F in replacement of microprocessor based control card for each phase complete all as specified
S & F in replacement PCB holder complete all as specified
S & F in replacement rotary switch 5 Amps for RYB phase complete all as specified
S & F in replacement servo motor 3 Kg torque complete all as specified
S & F in replacement servo motor 10 Kg torque complete all as specified
S & F in replacement servo motor 20 Kg torque complete all as specified
S & F in replacement of carbon brush (20 Amps to 200 Amps) complete all as specified
S & F in replacement of carbon holder and spring complete all as specified
S & F in replacement servo motor gear pinion complete all as specified
S & F in replacement RC Net work for 3 Kg motor complete all as specified
S & F in replacement RC Net work for 10 Kg motor complete all as specified
S & F in replacement RC Net work for 20 Kg motor complete all as specified
S & F in replacement drive assembly 20 KVA to 50 KVA per phase complete all as specified
S & F in replacement drive assembly 100 KVA per phase complete all as specified
S & F in replacement drive assembly 250 KVA per phase complete all as specified
S & F in replacement of digital control panel with circuit board for high / low voltage cut phase suitable for 3 phase voltage stabilizer of capacity 20 KVA to 250 KVA complete all as specified
S & F in replacement of front control with wiring kit complete all as specified
S & F in replacement of dimmer starter ( barrier) for 50 KVA 3 phase servo- stabilizer with super enamel copper wounded complete all as specified
S & F in replacement of dimmer for 100 KVA 3 phase servo- stabilizer with super enamel copper wounded complete all as specified
S & F in replacement of dimmer for 250/300 KVA 3 phase servo- stabilizer with super enamel copper wounded complete all as specified
S & F in replacement of transformer assembly for 50 KVA 3 phase servo- stabilizer with super enamel copper wounded complete all as specified
S & F in replacement of transformer assembly for 100 KVA 3 phase servo- stabilizer with super enamel copper wounded complete all as specified
S & F in replacement of transformer assembly for 250/300 KVA 3 phase servo- stabilizer with super enamel copper wounded complete all as specified
Supply and filling for toping up transformer oil of approved quality having dielectric strength not less than 60 KV tested in 2.10 mm gap, ISI marked for filling in transformer for topping up complete all as specified
S & F in replacement of lead acid battery 12 Volts DC 26 AH complete all as specified
S & F in replacement of lead acid battery 12 Volts DC 42 AH complete all as specified
S & F in replacement of lead acid battery 12 Volts DC 65 AH complete all as specified
M & L servicing and cleaning of UPS and transporting to workshop if necessary, checking , testing and locating faults capacity upto 5 KVA including repair to same by replacing new spares and reconnection complete all as specified Note:- cost of spare parts shall be measured and paid separately.
M & L servicing and cleaning of UPS and transporting to workshop if necessary, checking , testing and locating faults capacity 10 to 30 KVA including repair to same by replacing new spares and reconnection complete all as specified Note:- cost of spare parts shall be measured and paid separately.
S & F in replacement of PCB suitable for 1 to 5 KVA UPS complete all as specified
S & F in replacement of transformer suitable for 1 to 5 KVA UPS complete all as specified
S & F in replacement of IGBT suitable for 1 to 5 KVA UPS complete all as specified
S & F in replacement of SER suitable for 1 to 5 KVA UPS complete all as specified
S & F in replacement of PCB suitable for 10 to 30 KVA UPS complete all as specified
S & F in replacement of transformer suitable for 10 to 30 KVA UPS complete all as specified
S & F in replacement of IGBT suitable for 10 to 30 KVA UPS complete all as specified
S & F in replacement of SER suitable for 10 to 30 KVA UPS complete all as specified
S & F in replacement battery charger cum inverted (UPS) input / out put voltage 220 Volts 50 Hz single phase complete with DC bus bar rating 24 volts 150 AH complete all as specified
M/s Kataria Construction Company
M/s VISHAL ELECTRIC STORE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .