| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.9 L+₹1.0 L (4.80%)Rejected-Finance | L2 | Rejected-Finance Quoted amount is more than L1 | |
| 3 | L3₹24.5 L+₹3.6 L (17.2%)Rejected-Finance 119 LANE NO 4 DAYA NAND NAGAR LAWRENCE ROAD AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L3 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹19.4 L
EMD Value
₹39,000
Closing Date
29 Mar 2022, 6:00 pmClosed
Major S Rakesh
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
SPECIAL REPAIR TO KOTE BLDG AND CONVERSION OF OVERHEAD LINE TO UNDERGROUND NETWORK IN ADM AREA AT 23 INF DOU AT NAMKUM UNDER GE RANCHI
2022_MES_503732_3
8200/1389/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class E Cat a (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹39,000
Yes
23 May 2022
16 Mar 2022
31 Mar 2022
17 Mar 2022
29 Mar 2022
17 Mar 2022
Amount
Dismantling AC/ CGI/ translucent ( corrugated, semicorrugated,etc), as in roof covering, complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section in any position, complete all as specified and directed.
Dismantling of roof trusses, purlin, rails fastening, etc, of steel section, complete all as specified and directed.
M&L roof trusses (framed ), trussed, purlins, rails & fastening and heavy bracket framing (beam, tee, angle, channel, flat, etc) incl distance pieces, cleats , holdfast etc, complete all as specified and directed.
M&L for MS flat (wind tie) as roof sheet securing incl distance pieces, cleats etc, complete all as specified and directed.
M&L 6 mm thick asbestos cement, corrugated or semi corrugated sheets in roof, walls etc fixed with L type or J-type or cranked hook bolts etc, complete all as specified and directed.
All as per item No 6 above but exept sheet
M&L asbestos cement two piece adjustable plain wing ridge 6 mm thick fixed with 'J' type hook bolts etc, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, Chhaja, etc fixed with self tapping screws, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridge,etc with self tapping screws, complete all as specified and directed.
Dismantling of wall/ceiling boards (fibre, pulp, insulation, etc) of any type including cover fillets, complete all as specified and directed.
M&L for providing aluminium snap Grid frame work for false ceiling with of size 605X605 mm ,using Main and cross tee of size 36.5mmX25mmX1.4mm,weighing 0.24 kg/RM and 23.5mmX26.4mmX1.4mm weighing 0.191Kg/RM respectively. the snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia MS wire/GI wire, J bolts, nuts and washers as per manufacturer's, complete all as specified and directed.
M&L 4mm thick non asbestos fibre designer cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws, complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frames) n.exc 1.5 Sqm each, complete all as specified and directed.
All as per item No 14 above but exc1.5 Sqm but n.exc. 4 Sqm.
S&F steel windows with side hung shutters incl projecting type hinges with one no MS flat iron 25x3 mm of appx 200mm length and two nos MS Tower bolt 150mm long and one peg stay on each leaf complete with glazing bars, dovetailed or welded complete
All as per item No 16 above but without glazing bars, complete all as specified and directed.
S&F framed work as in doors or gates of angle or other section with guesset plates complete doors etc to be prepared to hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging, incl hings also fastening and fixing, complete all as specified and directed.
S&F 1.00mm thick Mild steel, plain, black sheet in covering to door shutters; covering to door chowkats (frames) cut to size edges beaded if directed, holes punched;incl round headed screws, clout nails or rivets and fixed to wood or steel members, etc.,with plain 40 mm lap joints or welded/riveted seams including bending, turning up,mitred angles, stopped ends, outlets, etc, complete all as specified and directed.
M&L for hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe -290 Gde E-165, complete all as specified and directed.
M&L cement concrete type C - 1 (1:3:6) using 20 mm graded stone aggregate as in bed blocks,fillings for holdfast etc, complete all as specified and directed.
S&F framed work such as grills gratings etc with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars, barred iron doors, ladders framed, baluster walk ways, railings, framework of water tanks & similar wk conforming to Fe410-0 or Fe310-0.
S&F in repair Galvanised mild steel wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks etc, complete all as specified and directed.
Hacking out old boken glass(any thickness, size, quality or description) from wooden frames/steel frames glazed with oil putty or fixed with beads, complete all as specified and directed.
S& F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane, complete all as specified and directed.
M & L preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer, complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, complete all as specified and directed.
M&L rendering 10 mm thick in cement mortar 1:4 on chajjas/lintel etc and finished even and fair without using extra cement in patches, complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:6 in on surface of walls and finished even and fair (without using extra cement) in patches, complete all as specified and directed.
M & L preparation of new plastered surfaces of walls/chajja/lintel and applying three coats of white wash, complete all as specified and directed.
M&L preparation of old plastered surfaces of walls/chajja/lintel and applying one coats of white wash, complete all as specified and directed.
M&L preparation of new plastered surfaces of walls/chajja/lintel and applying two coats of cement based paint white or tinted over a coat of alkali resistant primer, complete all as specified and directed.
M&L preparation of new plastered surfaces of walls and applying two coats of oil bound distemper on walls, white or tinted over a coat of chalk whiting, complete all as specified and directed.
M&L for complete removal of existing surface and applying two coat of cement base paint on walls, etc white or tinted, complete all as specified and directed.
Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with 2mm thick wall care putty and preparation of surfaces for further treatment and applying two coats of distemper, oil emulsion white or tinted, complete all as specified and directed.
M&L preparation of old painted wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint), any colour, complete all as specified and directed.
Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete all as specified and directed.
M&L brick work with sub class 'B' brick straight or curved on plan exc 6m means radius build in cement mortar 1:6, complete all as specified and directed.
All as per item No 38 above but except bricks.
Demoliton of cement concrete in ground floor paving n exc 15cm thickness (below or above ground level), complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), complete all as specified and directed.
M&L Cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base etc, complete all as specified and directed.
M&L Cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in levelling course, coping, window cill etc, complete all as specified and directed.
M&L 40 mm thick PCC type B - 1 1:2:4 using 20 mm graded stone aggregate as in flooring finish even & smooth using extra cement, complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 20mm graded stone aggregate including finished surface even & fair without using extra cement as in plinth protection/hard standing including necessary form work of edge all as specified and directed. Note: 10mm wide and 75mm deep joints shall be made at 3 mtr intervel and at each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio 1:3, complete all as specified and directed.
M&L for non skid coloured ceramic tiles 300 x300 x7mm thick in floors etc over & including 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match, complete all as specified and directed.
M&L machine cut kota stone slab flooring 18-20mm thick over & including 20mm screed base in CM 1: 4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed.
All as per Item No 47 but as in Skirting with 10mm thick rendering in CM 1:3, complete all as specified and directed.
M&L for antifungal Chequered cement concrete tiles 30cm x 30cm x 22 to 25mm thick with grey cement and pigment over & including 20mm thick screed bed in CM 1:6, set, jointed and pointed in neat cement slurry in floors, complete all as specified and directed.
M&L for joint free non skid coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc over & including 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match, complete all as specified and directed.
All as per Item No 47 but as in Skirting with 10mm thick rendering in CM 1:3, complete all as specified and directed.
M & L machine pressed precast concrete coloured Inter locking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment, over sand cusion, over compacted surface, complete all as specified and directed.
M&L sand filling under paver including watering and consolidation, complete all as specified and directed.
S&F in repair MS conduit curtain rod with PVC coating fancy type drafry rod 20mm dia of any colour as approved design and fixed to wall, complete all as specified and directed.
S&F fancy type sofia brakcet for the curtain rod (suitable for 20mm dia curtain rod) of any approved colour and design, complete all as specified and directed.
Taking down carefully aluminium point wiring (light, Socket or power) complete including fittings and fixtures such as switches, ceiling roses pendents, regulators, sockets etc for re use to be measured separetly including making good the disturbed portion/surface, complete all as specified and directed.
M&L for point wiring complete as specified with 1100 V grade with 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor FRLS, multistranded passing through including heavy duty steel conduit surface type with all accessories surface type on wall with earth conductor 1.5 sq mm, complete all as specified and directed.
S&F FLP/WP switch flame proof rotary type with termination box in LM6,16 amp single pole 250V, complete all as specified and directed.
S&F LED light fitting 1X30W Flame proof weather proof CMRI certified recommended for gas/Vapour and IP 65 protection with diecast aluminium Housing with heat resistence toughned galss with LED tubelight fixtures driver holder connector complete with accessories pre wired and including connecting up eith 3 core flxible copper condutor cable with suitable size, complete all as specified and directed.
M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including concealed PVC conduit of size 20/25mm ISI marked inclusive of tees, bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- (a) One light point controlled by one, one way switch 5 Amps
All as per item No 61 above but for one 3/5 pin socket 5 Amp on independent board.with 1.5sqmmwire with 1.5sqmm earth wire.
All as per item No 61 above but for one 3/5 pin socket 5 Amp on same board, with 1.5sqmmwire with 1.5sqmm earth wire.
All as per item No 61 above but for 3 pins socket outlet 15 Amps independent with 4 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sqmm, complete all as specified and directed.
S&F for LED bulk head fitting 1x 9 Watt, complete all as specified and as directed.
S&F switch piano flush type/Bell push, 5 Amps, single pole one way. Make : Anchor/Havells/Legrand ( ISI marked)
S&F socket 5 pins, 6 Amp, flush type piano (multi purpose). Make : Anchor/Havells/Legrand ( ISI marked)
S&F Socket 15 Amps flush type 230 Volts , AC, complete all as specified and directed. Make : Anchor/Havells/Legrand ( ISI marked)
S&F switch 15 Amps flush type 230 Volts , AC, complete all as specified and directed. Make : Anchor/Havells/Legrand (ISI marked)
Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of size, complete all as specified and directed 2 core x 10 Sqmm.
S&F for sheet metal enclosure MCB DB 6 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4 mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 20 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion.
S&F MCB SPN 32 to 63Amps 415V incl all termnials, fitting etc. Make:-Indoasian/Havells / Legrand / L&T.
S&F MCB SP 6 to 40 Amps 415V incl all termnials, fitting etc. Make:-Indoasian/Havells / Legrand / L&T.
Excavation in trenches n. exc 1.5 m wide & n. exc 1.5 m in depth for laying under ground cables/erection of pole and getting out in hard/dense soil, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
Removal of excavated surplus material (Soil) to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above the starting point, complete all as specified and directed.
S&F GI pipe light grade100 mm dia as protection to cable along the pole / across road crossing/through culvert/passing through ceiling/walls with necessary clamps-02 nos(Flat iron 50x6mm) with, nuts and bolts, complete all as specified and directed.
Taking down old unserviceable and Supply , installation testing and commisioning of LT MCCB Panel Board of suitable size cubical weather, dust and vermin proof fabricated out of CRCA sheet steel suitable size thicness complete, MCCB panel board should be manufactured and supplied by ISO 9001 certified OEM of MCCB. The Busbar system should be duly type tested at NABL lab for short time with stand current of 1 Sec. it should be suitable for wall or floor mounting with Double door option, Panel board enclouser should be robust contruction and corresion resistance powder coated with seven tank process with locking arrangement fixed on suitable size foundation 60 Cm above the GL by providing angle iron of size 50 x 50 x 6 mm welded on all the four corners embedded in PCC 1:2:4 using 20 mm graded stone aggregate up to 30 Cm including electrical connection with lugs & glands complete comprising the the following :- (a) Copper busbar of high conductivity 400 Amps capacity 4 wire system - 01 set (b) MCCB , 250Amps , 35 KA, 04 Pole-01 Nos (Incoming) (c) MCCB , 200Amps , 35 KA, 04 Pole-01 Nos (Outgoing) (d) MCCB , 160 Amps , 25 KA, 04 Pole-02 Nos (outgoing) (e) Digital type panel mounted Voltmeter 0-500 volts. (f) Three phase Indication lamp LED type, - 01 Set {Set of three Nos (RYB) } (g) Digital type frequecy meter ,50 Hz, panel mounted Note: All Internal connection of MCCB from BUS Bar made By using copper busbar of rated Capacity. (g)
Supply and laying or fixing or passing through pipe testing and commissioning of 1100 Volts grade 'Heavy duty" PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed of size 150 Sqmm nominal cross sectional area 3.5 core confirming to IS specification. (Make : HAVELLS/GLOSTER CABLE LTD /CCI /NICCO/Finolex)
Supply and laying or fixing or passing through pipe testing and commissioning of 1100 Volts grade 'Heavy duty" PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed of size 95Sqmm nominal cross sectional area 3.5 core confirming to IS specification. (Make : HAVELLS/GLOSTER CABLE LTD /CCI /NICCO/Finolex)
Supply and laying or fixing or passing through pipe testing and commissioning of 1100 Volts grade 'Heavy duty" PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed of size 35Sqmm nominal cross sectional area 3.5 core confirming to IS specification. (Make : HAVELLS/GLOSTER CABLE LTD /CCI /NICCO/Finolex)
S&F Duct pipe double wall, corrugated HDPE 100mm dia outer dia, conforming to IS:14930 (Part- II) of approved colour with fittings for cable protection, complete all as specified and as directed. Make: Dutron/SFMC Pipe/Finolex
M/s Pramod Kumar Singh
india trading company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .