Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 51 KHAWAJA PORA NOWSHERA NOWSHERA SRINAGAR JAMMU KASHMIR 190011 | SRINAGAR | JAMMU AND KASHMIR | 190011 | Admitted-Finance |
Tender Value
₹17.9 L
Closing Date
5 Jan 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical SKIMS
SKIMS Soura
Balance work of Store Block at SKIMS Soura.
2021_SKIMS_153836_1
eNIT NO.SIMS/HEE/E/ET/37 of 2021-22 Dt. 17-12-202
Open Tender
Electrical Works
Item Rate
45 days
SKIMS Soura
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,500
Yes
Convener, purchase committee, Directorate of ISM
Exempted
31 Jan 2022
17 Dec 2021
7 Jan 2022
17 Dec 2021
5 Jan 2022
17 Dec 2021
270 days
Amount
Providing and laying of spans of 3 ½ core XLPE Al. cable Armored of various sizes as mentioned below size of 1.1KV grade from new ESS block
240 mm sq. 3 ½ core
Supplying and making end termination with and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 240 sq. mm (45mm)
Supplying and embedding 150mm dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
Fabrication , supply erection 50x50x6 mmangle iron structures/cross-Arms of sizes including drilling holes for insulator pins & nuts and bolts and painting one coat of red Oxide and minimum two coats of Paint as required at site.( To be fabricated as per drawing /requirement at site)
Providing & fixing of fresh lighting point (5-6 amp) exposed/recessed surface with using double locked PVC channel 25x2 mm thick with accessories to be fixed on the surface of the wall with rowel plugs, saddles, screws, using multi-strand 3 x1.5 mm sq. pvc insulated copper wire (P+N+E) (Havells/Finolex/ Polycab/ Paramount/ KEI make FR equivalent ) complete with P/F of switch 5/6 amps F/T to be fitted on 3mm Bakelite sheet suitable size,M.S/Wooden box, rowel plugs & screws etc. complete Point. (Lighting Points)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling/ chieseling as required.
Providing and fixing of LED 4feet long batten 6000/6500k Light having extruded aluminium body with anti-glare diffuser with energy efficient electronic driver CRI ≥ 80 with minimum sytem lumens 2000 and maximum wattage 20 , IP 20 , surge proctection 2KV or more including connection with multistrand copper conductor 3 core cable etc as required at sitewith burning hours greater than 50000 Hours.
Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supply installation testing and commissioning of dia 900/1600 RPM exhaust fans with plastic shutters and including the cost of wall opening and making good etc complete as required. a) 300 mm dia (Exhaust Fans)
Wiring for AC points with 2X4 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed PVC conduit along with 1 Nos 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supply and fixing of following size of medium class PVC conduit 2mm thick along with accessories like with rowel plugs ,screws ,sadlles ,bends etc complete as required at site
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve,10 KA SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
Circuit wire to be laid as per site requirements using multi strand pvc insulated FRLS copper wire excluding the cost of conduit.
a) 3x 1.5 mm 2 multi strand pvc insulated copper.
b) 3x 2.5 mm 2 multi strand pvc insulated copper.
c) 3x6 mm 2 multi strand pvc insulated copper.
d) 3x10 mm 2 multi strand pvc insulated copper.
Supplying and fixing following rating, 240/415 volts, “C”curve,10KA miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc (MCBs)
a) MCB single pole 6 A -32 A
b) MCB Double Pole 10 - 32 A
c) MCB DB 40 A
d) MCB DB 63A
Supply, Installation, Testing and Commissioning of 1200 mm sweep, Ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019),THD less than 10% and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulationresistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
SITC of 35 litres Electric Heater / Geyser of capacities as mentioned below with following parameters . 1.Energy saving. 5 Star Certification by BEE 2. Provision of Temperature regulation by means of external Knob 3. Power Rating:- 220/ 230V, 50 Hz, Single Phase. 4. Maximum Rated Pressure.= 8 bar 5. Installation Type Vertical / Horizontal mounted as per site requirement 6. Body Type:- Rust, water proof and Shock Proof outer body with attractive looks and corrosion resistant inner tank made of cold rolled steel ,resistant to hard water. 7. Element Type:- glass coated heating element to prevent from corrosion and hard water. 8.Safety Valve maximum pressure =8 bar maximum 9. Energy efficiency feature:- Should have high density PUF insulation for energy Saving 10. Anti syphon system to prevent back flow of water. 11. Should have Indicating Lamps for ON & CUTT OFF. 12. Confirming to :IS 2082:2018 , IS 302-1, IS 302-2-21
Providing & making RCC foundation of 1300mm(H)X600mmX600mm size with 1:1.5:3(1Cement, 1.5 Coarse, 3 Stone aggregate) complete with 12mm dia. M.S. bar for reinforcement along with centering & shuttering i/c supplying & fixing 600mm long , 16mm dia J type G.I, coated foundation bolt/ Anchor bolt with template suitable for 6.0mtr octogonal Pole 100mm dia 600mm length corgated pipe complete with excavation the soil & refilling, ramming, curing etc. as reqd. a) 06 meter Octogonal Galvanized Pole (Foundation)
Supply & errection of flange mounted 6mtrs long hot dip galvanized Octangonal Pole of following height made from 3 mm thick HT Steel plate, having top dia-70mm & bottom dia of 130 mm complete with average coating thickness of atleast 65 micron.( Subham poles. The galvanizing shall be done in single dipping. There shall not be any circumferential welding. Pole shall have door of approximate 300 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. Pole shall have galvanized base plate of size 220 mm x 220mm x 12 mm thick with provision of holes for 4 no. 20mm dia bolt. including supplying and fixing the following in the window box provided for cable termination a) Supplying and fixing 6mm thick laminated mounted sheet inside the window mounted on and including providing and welding 02 nos G.I. strips 3mm thick of suitable length and having suitable size tapped holes as reqd. (S L Poles)
Supply fixing of galvanized pole bracket (arms) of approved design suitable for above mentioned /existing pole completed in all respects with proper fabrication for installation of above street lighting fittings on the top of steel tubular poles. a) Double arm 1 meter long with an angle as per requirement. (Arm)
a) Single arm 1 meter long with an angle as per requirement. (Arm)
Providing, installation, testing and commissioning of LED Street light luminaire as per following specification 1. Input voltage : 150 V to 270 V 2. LDE lamp efficiency : Min 95 to 110 lumens/watt 3. Power factor : >0.90 4. Life expecting : 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 70-80 W 7. Luminous flux : 7000 to 8000 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture (Lumenaires S.L.)
Providing and laying of spans of 2 core XLPE Al. cable Armored of various a) 10 mm sq. (S. L. Cable)
SITC of LED Flood Light Lumenaires as per following Specfications: 1. Input voltage : 150 V to 270 V 2. LDE lamp efficiency : Min 95 to 110 lumens/watt 3. Power factor : >0.90 4. Life expecting : 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 70-80 W 7. Luminous flux : 7000 to 8000 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture (Lumenaires S.L.)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable.
Supply and fixing of 25mm dia medium class PVC conduit 2mm thick along with accessories like with cable ties ,bends etc complete as required at site .
Providing and laying of 25mmsq 3 ½ core/PE Al. cable Armored as fresh ones. 1.1KV grade. The job includes cost of excavation complete as required at site.
Wiring for light point/ fan point/ exhaust fan point point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
SITC of 10 Watt lED Bulkhead luminaire with burning hours greater than 40000 Hours.
SITC Of LED 4feet long batten 6000/6500k Light having extruded aluminium body with anti-glare diffuser with energy efficient electronic driver CRI ≥ 80 with minimum sytem lumens 2000 and maximum wattage 20 , IP 20 , surge proctection 2KV or more including connection with multistrand copper conductor 3 core cable etc as required at sitewith burning hours greater than 50000 Hours.
Wiring for light/ power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
100 mm X 100 mm X 60 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
a) 6 pin 15/16 A socket outlet
b) 15/16 A switch
Supply installation testing and commissioning of 300 mm Bird guard to pretect fan in running condition ,Double ball bearing with Heavy duty motor Rated speed = 1400 RPM . RAte voltage -220 to 240 Volts Air delivery 1600 Mhr/min
Making of earthing point with 2 inch dia GI pipe , B class , caged in 6 inch GI pipe class B in CCM compound and 10 feet Deep, as earthing electrode . The pit is to be dug using borewell and covered with 10''X10'' inch manhole cover .
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
M/S SHAH ELECTRICALS and MECHANICAL WORKS
M/s KASH ENGINEERS AND ASSOCIATES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .