| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹34.0 L+₹2.2 L (6.98%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹34.0 L+₹2.2 L (7.05%)Rejected-Finance NETAJI SUBHAS ROAD SUBHASPALLY SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹34.0 L+₹2.2 L (7.07%)Rejected-Finance C O UTTAM BANIK HAIDERPARA OPPOSITE TO WEST BENGAL REPRESENTATIVE REST HOUSE P O HAIDERPARA SILIGURI 06 | JALPAIGURI | WEST BENGAL | 734006 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹34.0 L+₹2.3 L (7.13%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
19 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) HASIMARA
GE (AF) HASIMARA PO HASIMARA DIST ALIPURDUAR PIN 735215 (WB)
REPAIR / MAINTENANCE OF COOLING APPLIANCES AT TECH, DOMESTIC, OMQ AND 10 AFH AREA UNDER GE (AF) HASIMARA
2021_MES_473990_1
C/8489/21-22/E8
Open Tender
Civil Works
Item Rate
330 days
GE(AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) HASIMARA
₹64,000
Yes
21 Jan 2022
9 Sept 2021
20 Oct 2021
9 Sept 2021
19 Oct 2021
28 Sept 2021
60 days
Amount
Taking down and Servicing of defective (outdoor and indoor unit) split type of AC of 1/1.5/2 TR capacity of any type/size/make/model including replacement of unserviceable parts and cleaning, washing condenser assembly by chemical, checking, re-tightening of all electrical connections, replacement of nuts, bolts, screws, washers, drain pipe, internal wiring, gas charging valve, re-assembling, re-alignment/re-fixing indoor and outdoor unit properly, repairing remote kit with parts/re-pairing display panel with parts etc bracket housing of capacitors, relay and re-assembling, refixing properly after repair, complete all as directed by Engineer-in-charge . (Note : (a) Spare parts will be measured & paid seperately under relevent items as supply only. (b) Fixing charges of parts/spares are deemed to be included in the unit rate. (c) Refrigerant gas filled shall be measured and paid seperately under respective items)
Opening for repair of defective deep freezer of capacity 400 Ltrs of any type/make/model including replacement of unserviceable parts and cleaning, washing condenser assembly with chemical, checking, re-tightening of all electrical connections, replacement of nuts, bolts, screws, washers, drain pipe, internal wiring, gas charging valve, repairing/replacement of relay and re-assembling properly after repair, complete all as directed by Engineer-in-charge. (Note : (a) Spare parts will be measured & paid seperately under relevent items as supply only. (b) Fixing charges of parts / spares are deemed to be included in the unit rate (c) Refrigerant gas filled shall be measured and paid seperately under respective items)
Opening for repair of defevtive water cooler of capacity 40 to 150 Ltr of any type/make/model including replacement of unserviceable parts and cleaning, washing condenser assembly, body of water cooler and cleaning, rubbing and washing of storage water tank, draining of dirty water silt, checking, re-tightening, all electrical connections, replacement of nuts, bolts, screws, washers, drain pipe, internal wiring, fixing properly bracket housing of capacitors, relay etc and re-assembling properly after repair, complete all as directed by Engr-in-charge. (Note : (a) Spare parts will be measured & paid seperately under relevent items as supply only. (b) Fixing charges of parts / spares are deemed to be included in the unit rate (c) Refrigerant gas filled shall be measured and paid seperately under respective items)
Taking down and Servicing of defective window type AC of 1.5 to 2 TR capacity, any type/ size/ make/model including replacement of unserviceable parts and cleaning and washing, condenser asembly by chemical, checking and re-tightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring, fixing properly bracket housing of capacitors, relay etc and re-assembling and refixing properly after repair, complete all as directed by Engr-in-charge. (Note : (a) Spare parts will be measured & paid seperately under relevent items as supply only. (b) Fixing charge of parts / spares are deemed to be included in the unit rate, (c) Refrigerant gas filled shall be measured and paid seperately under respective items)
Taking down and opening for repair of defective refrigerators of 165 Ltr to 320 Ltr capacity, any type/size /make /model including replacement of unserviceable parts and cleaning, washing, condenser assembly, re-tighening all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring, fixing properly bracket housing of capacitors, relay etc and re-assembling properly after repair, complete all as directed by Engr-in-charge. (Note : (a) Spare parts shall be measured & paid seperately under relevent items as supply only, (b) Fixing charge of parts/spares are deemed to be included in the unit rate, (c) Refrigerant gas filled shall be measured and paid seperately under respective items)
Material and labour for testing leakage of gas and replacement of damaged portion of copper pipe of any dia upto 30cm length, brazing by oxyaccetelene gas welding and good quality copper brazing rods or soldering damaged portion, flaring copper pipe, replacement of flare nut and pouring the nitrogen gas flushing to check the leakage in copper pipe lines, recharging suitable gas fully after complete removal of nitrogen gas on satisfactorily completion of leak test, re-assembling and testing cooling of whole refrigerator of any capacity/type and make complete all as directed by the Engr-in-charge. (Note :-Refrigerant gas filled shall be measured and paid as supply only under respective items)
All as per serial item No 6 above but with R-22 gas for window AC of any capacity/make/type complete all as directed by the Engr-in-charge.
All as per serial item No. 6 above but with R-134 gas for water cooler of any capacity/make/type complete all as directed by the Engr-in-charge.
All as per serial item No 6 above but AC with R-22 gas for split type of any capacity/make/type complete all as directed by the Engr-in-charge.
Supply and fix in repair power unit with 20 Amps starter incl 4 model plate, 20A plug and socket, PVC box for mounting of power unit suitable for 25 Amps power unit and connection of electric supply and testing, complete all as specified and directed. (Make :- Havell's Crabtree cat no ACTO252504 or equivalent model of make as per list of manufacturer)
M & L Sub main wiring with two runs of 4 sqmm (Nominal area) single core cable FRLS PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through PVC conduits/casing-caping of suitable size, fixed to wall/ceiling etc including 4 sqmm (nominal area) single core, FRLS PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size and taking down/out old unserviceable sub main wiring complete all as specified and as directed by Engineer-in-charge. (Note : PVC Conduits/Casing-caping, two run cables and one run of earth wire shall be measured as one length.)
M & L for Sub main wiring with two runs of 6 sqmm (Nominal area) single core cable FRLS PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through and including PVC conduits/casing-caping of suitable size, fixed to wall/ceiling etc including 6 sqmm (nominal area) single core, FRLS PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size and taking down/out old unserviceable sub main wiring complete all as specified and as directed by Engineer-in-charge. (Note : PVC Conduits/Casing-caping, two run cables and one run of earth wire shall be measured as one length.)
Dismantling and taking down from existing position window type AC 1.5 / 2 Ton capacity and re-fixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position and new position including necessary transportation of the same to new position etc complete all as directed by Engr-in-Charge.
Dismantling and taking down from existing position split type AC of capacity 1/1.5 / 2 Ton and refixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position and new position including necessary transportation of the same to new position etc all as specified and directed.
Taking down and Dismantling the unserviceable blower motor from 1/1.5/2 TR window/split AC of any type including opening all outer case and rewiding, heat varnishing the blower motor with super enamel copper wire of suitablle gauge by taking out burnt winding and cleaning the iron core complete as directed by Engr - in - charge. (Note:-(i) Unit quoted rate shall deemed to be inclusive of cost of transportation from site of work to workshop and back for repair)
All as per serial item No 15 above but for blower motor of water cooler of capacity 40 to 80 Ltr complete as directed by Engr - in - charge.
Supply only Potenital Relay box type suitable for refrigerator of any make/model/capacity, complete all as per existing specifications and directed.
All as per serial item No. 17 above but Auto defrost Thermostat switch complete as directed by Engr - in - charge. (Make:Ranutrol / Indfos / Denfos)
All as per serial item No. 17 above but Pigmay bulb (Thick/Thin Thread) 230 Volt complete as directed by Engr - in - charge.
All as per serial item No. 17 above but Strainer as per sample complete as directed by Engr - in - charge. (Make: Ranutrol / Indfos / Denfos/Godrej/Annapurna)
All as per serial item No. 17 above but Hermetic sealed type compressor suitable for 180/260 Ltr complete as directed by Engr - in - charge. (Make : LG/Samsung/BPL/Hitachi/Emerson)
All as per serial item No. 17 above but Hermetic sealed type compressor suitable for 280/320Ltr complete as directed by Engr - in - charge. (Make : LG/Samsung/BPL/Hitachi)
All as per serial item No. 17 above but Freezer Fan motor (as per sample) single phase 230 Volt, 50 Hz suitable for refrigerator of capacity 280 to 310 Ltr complete as directed by Engr - in - charge. (Make : Marathon Electric / Frac Master / M Bajaj Electric)
All as per serial item No. 17 above but cooling coil assembly suitable for 180 to 310 Ltr capacity of Refrigerator complete as directed by Engr - in - charge.
All as per serial item No. 17 above but Defrost heater suitable for 180 to 310 Ltr capacity of Refrigerator complete as directed by Engr - in - charge.
All as per serial item No. 17 above but Timer switch suitable for 180 to 310 Ltr capacity of Refrigerator complete as directed by Engr - in - charge.
All as per serial item No. 17 above but By-metal unit assembly suitable for 180 to 310 Ltr capacity of Refrigerator complete as directed by Engr - in - charge.
Supply only Overload protector relay as per sample for window type AC of any make/model/capacity complete as directed by Engr - in - charge.
All as per serial item No. 28 above but Potential relay box type as per sample complete as directed by Engr - in - charge.
All as per serial item No. 28 above but Thermostat switch complete as directed by Engr - in - charge. (Make: Ranutrol / Baba)
All as per serial item No. 28 above but Fan motor single phase 230 Volt, 50 Hz as per sample complete as directed by Engr - in - charge.
All as per serial item No. 28 above but Strainer of capillary tube as per sample complete as directed by Engr - in - charge.
Supply only Hermetic sealed type compressor of capacity 1.5 TR complete as directed by Engr - in - charge. (Make : LG/Kirloskar/ Tecumseh BPL/Hitachi)
Supply only Rotary compressor for 1.5 Ton capacity suitable for Split type AC of any make / model 1.5 TR capacity complete all as per exisiting specifications and as directed. (Make : Hitachi / Samsung / LG / BPL)
All as per serial item No. 34 above but Rotary compressor for 2 Ton capacity complete as directed by Engr - in - charge. (Make : Hitachi / Samsung / LG / BPL)
All as per serial item No. 34 above but Harmetic sealed compressor for 1.5 Ton complete as directed by Engr - in - charge. (Make : Kirloskar / Tecumseh / Carrier)
All as per serial item No. 34 above but Harmetic sealed compressor of 2 Ton capacity complete as directed by Engr - in - charge. (Make : Kirloskar / Tecumseh / Carrier)
All as per serial item No. 34 above but Power contactor suitable for 1.5/2 Ton capacity complete as directed by Engr - in - charge.
All as per serial item No. 34 above but Fan motor single phase 230 Volt, 50 Hz as per sample complete as directed by Engr - in - charge.
All as per serial item No. 34 above but Strainer of capillary tube as per sample complete as directed by Engr - in - charge.
All as per serial item No. 34 above but Sensing unit with complete accessories any make / capacity complete as directed by Engr - in - charge. (Make : LG/Samsung / Carrier / Weather Maker )
All as per serial item No. 34 above but Multi terminal capacitor (50+6/50+4mfd) suitable for Split AC (stating, running and fan combined) complete as directed by Engr - in - charge.
Supply & Fixing drain pipe for split AC as per existing complete all as specified and as directed
Supply & Fixing PCB for outdoor unit of invertor AC model and make as per existing complete all as specified and as directed
Supply & Fixing PCB for indoor unit of invertor AC model and make as per existing complete all as specified and as directed
Supply only Blower motor Indoor unit single phase 230 V suitable for Split type AC 1.5 ton complete all as specified and as directed
S & F in repair Copper tube 1/4" as per sample, complete all as specified and as directed
S & F in repair Copper tube 1/2" as per sample, complete all as specified and as directed
S & F in repair Insulation tube 1/4" as per sample, complete all as specified and as directed
S & F in repair Insulation tube 1/2" as per sample, complete all as specified and as directed
S & F in repair Copper tube 5/8" as per sample, complete all as specified and as directed
S & F in repair Insulation tube 5/8" as per sample complete all as specified and as directed
S & F in repair Remote Control suitable for 1.5/2 Ton split / window type AC as per sample, complete all as specified and as directed
Supply only Overload protector relay suitable for 40 to 150 Ltr water cooler complete as directed by Engr - in - charge.
Supply only Potential relay box suitable for 40 to 150 Ltr water cooler complete as directed by Engr - in - charge.
Supply only Thermostat switch suitable for 40 to 150 Ltr water cooler complete as directed by Engr - in - charge.
Supply only Chromium plated brass push cock 1/2" (inner/outer thread) dia suitable for water cooler complete as directed by Engr - in - charge.
Supply only 15mm bore PVC ball valves high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete as directed by Engr - in - charge.
Supply only 15mm bore stop cock, cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete as directed by Engr - in - charge.
Supply only Fan motor, single, phase 230 volts 50 Hz suitable for water cooler of 40 ltr cooling capacity complete as directed by Engr - in - charge. (Make: Marathon Electric / Frac Master / M Bajaj Electric)
Supply only Condenser unit assembly suitable for 40 to 80 ltr capacity water cooler complete as directed by Engr - in - charge. (Make: Universal / Sarada / Keltron)
Supply only Drain pipe PVC medium grade 25mm dia with 23mm GI clamp for water cooler complete as directed by Engr - in - charge.
Supply only 15mm dia PVC cold water pipe with both ends brass / chromium coated socket complete as directed by Engr - in - charge.
Supply only Harmetic sealed compressor suitable for cooling capacity 40-120 Ltr water cooler complete as directed by Engr - in - charge. (Make: LG / Samsung / Carrier/Emersion)
Supply only Condenser unit suitable for Split AC 1.5 /2 Ton capacity complete all as specified and as directed
Supply only outdoor blower fan blade suitable for split AC 1.5/2 Ton complete all as specified and as directed
Supply only deep freezer themostat suitable for 400 Ltr capacity complete all as specified and as directed
Supply only timer of refrigerator suitable for 165 to 320 Ltr capacity, complete all as specified and as directed
Supply only By-metal of refrigerator suitable for 165 to 320 Ltr cabacity, complete all as specified and as directed
Supply only heater of refrigerator suitable for 165 to 320 Ltr capacity, complete all as specified and as directed
Repair / maintenance of voltage stabilizer of capacity 5/4 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+ 1%) and automatic change over circuit etc complete all as specified and directed. (Note : Minor defective parts shall be replaced by the contractor and the rate of the same shall deemed to be included in quoted rate.)
Repair / maintenance of voltage stabilizer of capacity 2/1 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+ 1%) and automatic change over circuit etc complete all as specified and directed. (Note : Minor defective parts shall be replaced by the contractor and the rate of the same shall deemed to be included in quoted rate.)
Supply and filling Refrigerant Gas R- 22 in the factory sealed container where ever required complete all as specified and as directed. (Make : Mafron ,Refron,Floron).
Supply and filling Refrigerant Gas R- 134a in the factory sealed container where ever required complete all as specified and as directed. (Make : Mafron ,Refron,Floron).
Supply and filling Refrigerant Gas R- 32 in the factory sealed container where ever required complete all as specified and as directed. (Make : Mafron ,Refron,Floron).
Supply & Fixing of Split AC outdoor mounting stand as per existing complete all as specified and as directed.
S & F MCB Single Pole and Neutral (SPN) of capacity 6 to 32 Amps, 240 volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position complete all as specified and as directed. (Make: Legrand/Siemens/ABB)..
S & F MCB Single Pole (SP) of capacity 6 Amps to 32 Amps, 240 Volts AC, breaking capacity 10 KA, C Series, fixed in proper position complete all as specified and as directed.(Make: Legrand/Siemens/ABB).
Supply only Starting capacitor 50-100 Mfd complete as directed by Engr - in - charge. (Make : Keltron / Sarada / Usha)
Supply only Running capacity 30-50 Mfd complete as directed by Engr - in - charge.(Make : Keltron / Sarada / Usha )
S & F Factory made board distribution (DB) Double door, sheet metal enclosure with common bus bar at incomming end, SPN , 4 way ,240 Volts suitable for housing MCBs complete all as specified and directed. (Make : Legrand and equivalent model as approved)
S & F Factory made board distribution (DB) Double door sheet metal enclosure with common bus bar at incomming end, SPN , 8 way ,240 Volts suitable for housing MCBs complete all as specified and directed. (Make : Legrand and equivalent model as approved)
M & L for repairing of PCB of split / window AC with change of necessary spare parts/items as required and as directed by Engineer -in-charge.
Dismantiling of MS cross arm bracings, channel, angel sections etc from any position complete all are specified and directed.
Material and labour for cross arm, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers and welding where necessary, bending, drilling holes for bolts in any shape or size including two coats of synthetic enamel paint over a coat of red oxide primer complete all are specified and directed.
S&F flexible PVC insulated, FR, PVC multistranded cables with copper conductor, 3 core for voltage grade upto 1100 V complete all are specified and directed.
Supply only capacitor 5/6 Mfd for fan motor complete as directed by Engr - in - charge. (Make : Keltron / Sarada / Usha) Note: An amount of Rs. 58600.00 on account of credit schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
KD SAHA and CO.INDIA
SARKAR ENGINEERING CO.
M/s. STRUCTURES INDIA
BEEPEE AND COMPANY
Shree Ram Construction
M/S BIJAY KUMAR SHIVA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .