Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.4 L+₹53,640 (4.17%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹14.1 L+₹1.2 L (9.49%)Rejected-Finance NEAR KRIPAN GATE PO BINNAGURI DIST JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | L3 | Rejected-Finance Being not L1 |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
20 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Subhro Banerjee CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVISION OF POWER BACKUP FOR CLASSROOM AND 9(T) MESS AT ATS BELAGAVI
2021_MES_480236_3
81188/E8
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Sambra
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Sambra
₹27,000
Yes
8 Feb 2022
23 Dec 2021
22 Jan 2022
23 Dec 2021
20 Jan 2022
8 Jan 2022
23 Dec 2021 - 31 Dec 2021
60 days
Amount
Supply, install, testing and commissioning of acoustic proof diesel engine driven generating set, fully wired, 415 Volts, AC, 3 phase 4 wire, 50Hz having capacity 66KW / 82.5 KVA continous rating at power factor 0.8 (lagging) as per IS-4722 and connections as per IE rules complete with liquid cooled 4 stroke Diesel engine with electric start with 12V DC battery, developing minimum 110 BHP at 1500 RPM under NTP prevailing at Sambra area, Belagavi considering derating factor and shall conform to IS:10000 / 150 3026 / BS-5514 with provisions of 10% over loading for 1 hour for every 12 hours running with A1 class governing and all standard safety type, screen protected, revolving field, self excited, self regulated alternator conforming to BSEN-60034 with IP 23 protection complete with integrated AMF control panel with microprocessor based relays/ MCCB / MCB's / Contactors, multifunction meter showing KWH, KVA, PF, Amps, Volts, frequency, indicating lamps, 12 Volt battery charging unit including 12 Volts battery etc required as per latest standard engineering practices including sound proof canopy designed to meet MoEF / CPCB Norms of 75dBA at 1mtr at 75% load, fabricated from CRCA sheet and a structural / sheet metal base frame , with high quality noise absorbent and fire retardant grade acoustic insulation material conformity to IS : 8183 and integrated fuel tank of capacity not less than minimum 8 hrs running fuel filling arrangement from inside duly painted after necessary pre treatment process complete all as specified and as directed.
Make : Cummins/ Kirloskar/ Greaves Cotton Make of Engine : Cummins/ Kirloskar green Make of Alternator: Stamford / Kirloskar / Crompton Greaves
Note: (i) The cost of PCC foundation as per the recommendation of OEM shall be deemed to be included in the quoted rate. (ii) Cost of fuel and other expenses for carrying out acceptance test of the DG set shall deemed to be included with the quoted rate.
M&L for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level surrounding with adequate quantity of charcoal dust mixed with salts to a packet thickness of 15 cm all around the plate,using GI earth strip 32x6 mm connected to earth plate by means of nut, bolt, check nuts and washer of as directed GI pipe light grade 40 mm bore for strip protection and water pipe medium grade 20 mm from earth chamber to upper edge of earth plate, light grade and connected to main switch board upto 7.5 mtr away from earth electrodeincl excavation,CI funnel with wire mesh fixed on waterpipe and PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in pit chamber and RCC pit cover 50 MM thick precast RCC 1:2:4 type B- I dully reinforced with MS bar 6 MM dia@ 150 CC both way with 10 mm dia MS bar in lifting handle excavation earth work including laying of GI pipe in walls, testing complete etc all as directed in electrical plate No 3 of SSR Part-I complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core all as specified and as directed.
Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in soft / loose soil complete all as specified and as directed.
Supply and spread dry river sand in trenches for cable cushioning all as specified on both top and bottom of cable including ramming all as specified and directed
Supply and laying well burnt sub class B bricks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all specified and as directed.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all specified and as directed.
M&L for GI pipes light grade galvanised with all fitting and fixed complete to poles/route/drains etc and ceillings or laid in floors of 80 MM dia.
RAINBOW ELECTRICALS
N K CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .