Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.8 LAccepted-AOC | ₹57.8 L | L1 | Accepted-AOC OK |
| 2 | L2₹58.3 L+₹49,340 (0.85%)Rejected-Finance | ₹58.3 L+₹49,340 (0.85%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹58.4 L+₹57,620 (1.00%)Rejected-Finance | ₹58.4 L+₹57,620 (1.00%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹59.7 L+₹1.8 L (3.15%)Rejected-Finance | ₹59.7 L+₹1.8 L (3.15%) | L4 | Rejected-Finance Not being L1 |
Tender Value
₹63.5 L
EMD Value
₹1.2 L
Closing Date
4 Jul 2020, 6:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
PROVN OF BORE WELL INCLUDING PUMP HOUSE BUILDING AND ALLIED WORKS AT DAMTAL UNDER GE(SOUTH) PATHANKOT
2020_MES_322899_2
CWE/P-50/2019-20
Open Tender
Civil Works - Water Works
Lump-sum
270 days
Pathankot
Class C category a ii
9 documents required · 9 mandatory
₹1,000
Yes
GE(South) Pathankot
₹1.2 L
Yes
13 Aug 2020
30 May 2020
6 Jul 2020
30 May 2020
4 Jul 2020
20 Jun 2020
Amount
Lumpsum price worked out by the contractor for Building work as listed in Schedule 'A' Part-I.
Lumpsum price worked out by the contractor for Internal water supply as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for Plumbing work as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for Internal electric Supply as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for Path Work as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the contractor for as listed in Sewage Disposal Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for External Electrification work as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for Bore well and connected work as listed in Schedule 'A' Part-VIII.
M&L Point wiring for light/fan/bell point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings including galvanised pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and including 1.5sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specfied and directed. Note : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green) (b) On RCC roof ceiling PVC conduit shall be provided on surface for fan with proper fixing clips all as directed.
All as per item No 9 here-in-before but for one 3 pin socket outlet 5 Amps independent.
All as per item No 9 here-in-before but for one 3 pin socket outlet 5 Amps on the same board with other switches.
M&L Point wiring for 15 A switch socket controlled by one switch with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings including galvanised pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specfied and directed. Note : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green)
Supply and laying submain wiring alongwith two single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of size 6 sqmm drawing into and including concealed PVC rigid non metallic conduit of 20mm dia , 1.8 mm wall thickness and single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of 6 sq mm as earth wire including cutting chases in brick wall, rendering in cement mortar 1:4 and making good the disturbed surfaces to match existing complete all as specified & directed. Note: (i) Two runs of 6 Sqmm single core PVC insulated copper conductor cable(FRLS) and one run of 6 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of 20mm dia , 1.8 mm wall thickness wiil be measured as a one unit. (ii) Proper colour coding is to be followed as per IS Specification.
MCB SP, 240 Volt, 50 Hz with 10 KA , C curve type breaking capacity rating 6 to 32 Amps all as specified and directed.
MCB SPN, 240 Volt, 50 Hz with 10 KA , C curve type breaking capacity rating 6 to 32 Amps all as specified and directed.
M & L for 1200 mm Sweep Ceiling Fan, energy saving 5 star rated, complete with canopy, blades, down rod, split pin etc complete of approx wattage 50 Watt rated suitable for operation on AC 220-240 V AC, 50 HZ, Air delivery approx 210 cum/min suitable for 5 speed control.
Ventilation fan AC sinlge phase 230/240 volts of size 200 mm sweep having plastic body with louvre including connecting to ceiling rose all as required or directed including connecting to ceiling rose all as required or directed.Note: Test report and Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment.
Supply and Fix LED tube light fitting complete 20W with decorative type fitting 4 feet long aluminium extruded housing,IP-20 ,rated voltage 230 V, 50 hz, system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed. Notes: (i) LM79 report from third party (instead of company in house lab) NABL/UL accredited lab (ii) LM 80 report from LED manufacturer (iii) Test certificates to be submitted before commencement of work/ claiming for payment . (iv) Warranty certificate for minimum 2 years to be submitted from OEM.
Supply and fix bldg security light fittings with LED security light fittings 45 watt, IP 65 having pressure die cast aluminium alloy housing, prismatic polycarbonate cover complete including making connection with 3 core copper flexible cable of suitable size including galvanised iron pipe bracket 0.90 metre long of 40 mm dia and fixing with bldg for fixing of street light fitting all as directed. Notes :- (i) Contractor shall produce LM79 & LM 80 test report from OEM owned NABL accredited laboratory. (ii) Contractor shall give guarantee/ warranty of complete fitting/ fixture for minimum 2 years from the date of completion. (iii) Contractor shall arrange complete material at site for approval of GE before incorporation in the work. (v) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt.
Earthing complete with galvanized steel earth plate electrode 60cmx60cm and 6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Material and labour earthing with steel earth plate electrode of size 600x600x6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in electrical plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing)
Transportation of suitable RIG machine & all necessary machinery/T&P for mechanical percussion method and dual rotary system complete and Material and Labour for drilling of bore holes in any strata by mechanical percussion upto minimum 100 m depth and further by dual rotary system complete or depth below ground level pipe in any kind of strata soils /rocks, disposal of surplus soil with in 100 m, keeping space for pea gravel packing with system as recommended by CGWB report submitted by contractor and including lowering and extraction of casing pipes of suitable thickness as per IS 4270:2001 after lowering of assembly of ERW pipes complete all as specified and directed. Note:- a) For laying casing pipe include all mechanical equipment shall be arranged by the contractor and the same shall remain property of the contractor after completion of the job/contract. b) In case of non extraction of casing pipe due to failure of borewell the contractor will have no claim what so ever on this account. (a) 600 mm (24 inches) Bore hole:-
(i) From GL to 20 m Below ground level
(ii) From 20 m Below ground level to 40 m Below ground level
(iii) From 40 m Below ground level to 60 m Below ground level
(b) 450 mm (18 inches) Bore hole:-
(i) From 60 m Below ground level to 80 m Below ground level
(ii) From 80 m Below ground level to 100 m Below ground level
(c) 380 mm (15 inches) Bore hole:-
(i) From 100 m Below ground level to 140 m Below ground level
(d) 300 mm (12 inches) Bore hole:-
(i) From 140 m Below ground level to 200 m Below ground level
Supply , assembling, fixing & lowering of the liner tubewell asembly or strainer in position complete (net effective length shall only be measured and paid) all as specified and directed by Engr-in-charge as mentioned below :-
(a) Mild steel ERW screwed and socketed housing pipes 300 mm (12 inch) nominal bore having minimum 8 mm wall thickness conforming to IS : 4270-2001 & all around welded with 4 Nos stiffeners of flat iron 40 x 6 mm, 300 mm long.
(b) Mild steel ERW screwed and socketed housing pipes 200 mm (8 inch) nominal bore having minimum 8 mm wall thickness conforming to IS : 4270-2001 & all around welded with 4 Nos : stiffeners of flat iron 40 x 6 mm, 300 mm long.
(c) Mild steel ERW screwed and socketed slotted pipes 200 mm (8 inch) nominal bore having minimum 6.4mm wall thickness conforming to IS : 4270-2001 having slot sized 1.6mmx75mm & all around welded with 4 Nos : stiffeners of flat iron 40 x 6 mm, 300 mm long.
M & L for providing & fixing of 12" x 8" sleeve joint (reducer of approprate size ) complete all as specified and directed.
M & L for housing pipe clamp (to hold well assembly) made of MS flat 150 mm x 20 mm 1.5 metre long (each Flap) made to shape suitable for 12 inch bore pipe including making two nos holes of 25 mm dia on both sides of flap and fixing with and including suitable size of nuts and bolts & washers complete all as specified and directed.
Supply and laying Pea Gravel of size 2 mm to 6 mm around the liner assembly from bottom to ground level including continuous watering during development complete all as specified and directed by Engr-in-charge
Providing & fixing of well cap for 300 mm bore pipe made out of MS pipe of suitable size 300 mm long duly internally threaded and covered with MS round MS flat not less than 6 mm thick duly welded 300 mm long 100 mm wide and 10 mmm thick MS flat on two sides of well cap fabricated complete all as specified and directed.
Development of Tube well by means of pumping by air compressor of minimum pressure 10 Kg/cm, untill sand free and clean water is obtained at optimum yield complete all as specified and directed by Engr-in-charge below :- (Yeild Testing)
(a) First 24 hours of develompent
(b) Subsequent development beyond 24 hours (if required)
Supplying wooden (made out of IInd class hard wood )strata sample box with glazed shutter and pigeon holes not less than 100 mm for samples at every interval of 3 m complete all as specified and directed.
Supply and fixing of 8"dia bail plug complete all as specified and directed by Engr-in-charge
Supply and fixing of 50mm x 6 mm centre guides of required size including welding to casing pipe complete all as specified and directed.
Construction of foundation to tubewell of size 1 m x 1m having 45 cm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) over 75 mm thick PCC 1:3;6 type C-2 with GI pipe 80 mm dia medium grade 4 Nos having length not less than 1 metre each complete as per site requirement embedded throughout the block with GI plug complete all as specified and directed.
S&F for Cl swing check NRV conforming to IS-5312, sutiable for 80 mm bore pipe consisting Cast iron Body, door as per IS 210, Bronze body ring as per IS 318, natural rubber door face, hinge pin SS ASTM A276 type 410, fasteners as per IS 1367, Natural rubber gasket, etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
M&L of making column pipe fabricated out of 80 mm dia heavy grade GI pipe 3 metre long duly welded with MS flange on both sides ( MS Flanges thickness not less than 10 mm having 2 nos groove cuts to accommodate submersible cable , minimum 4 Nos holes drilled of suitable size) including fixing with suitable size of rubber gasket having thickness not less than 3 mm and jointing with and including suitable size of bolts & nuts and washers complete all required at work site.
S&F for Cl sluice valve, non-rising type conforming to IS-14846, suitable for 80 mm bore pipe consisting of SS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210, greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheel etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
Material and labour GI tubing light grade 50 mm bore for cable protection including jointing complete all as specified and directed.
Material and labour flat 3 core 1100V grade submersible PVC insulated and seathed 16 Sqmm nominal area strandard copper conductor water proof submersible cable suitable for submersible pump motor including connection cable to starter complete all as specified and directed by Engr-in-charge.
Material and labour steel wire rope 3/8" dia with clamps of suitable size for securing the pump motor assembly complete all as specified and directed by Engr-in-charge.
Supply, fixing and laying ductile Iron pipe, socket & spigot type with bulb type rubber tyton gasket and jointing material as per standard complete of Class "K-9" complete in trenches/ on pedestals etc complete of 200 mm bore dia size all as per IS: 8329 and with internal Cement Mortal Lining (CML) and outside black bitumen coating etc all as specified and directed by Engr-in-Charge.
S&F for Cl sluice valve, non-rising type conforming to IS-14846, sutiable for 200 mm bore pipe consisting of SS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210, greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheel etc complete double end flanged and drilled, of Class PN-1.0 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
Supply, installing, testing and commissioning of LT feeder pillar box factory made cubical indoor type, fabricated out of 2.00 mm thick CRCA sheet with angle iron base frame made of 40 x 40 x 6mm , 45 cm height, floor mounted with nut/bolts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-42 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands and including provn of the following:- Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
a) Aluminium Bus bar 100-A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulation. b) MCCB TP 32 Amp 415 volt 50HZ AC supply 18 KA (Thermal magnetic release) Ics=100%Icu - 1No c) MCCB TP 25 amp 415 volt 50HZ AC supply 18 KA (Thermal magnetic release) Ics=100%Icu - 1 No d) MCCB TP 63 amp 415 volt 50HZ AC supply 18 KA(Thermal magnetic release) Ics=100%Icu - 2 No. e) MCB SPN 415 Volts 20 Amps – 01 No (Outgoing) Plant Room f) Digital type Volt meter, range 0 to 500 Volt with slector switch and PT. - 1 No g) Digital type Ameter , range 0 to 600 Amp with slector switch and CT - 1 No h) Indicator lamp RYB. - 01 set j) Change over on load of minimum cap 63 Amp FP -01 Nos k) Submersible pump controller starter with overload, single phasing, phase reversal, phase imbalance protection and all safety devices suitable upto min 30 HP 3 phase motor with relay max range 28 to 42 A.
M&L for Carrying out physical, chemical & Bacteriological analysis all as per IS 10500:2012 for water sample of the borewell from approved laboratory from auth Govt Lab Note: The rate qouted deemed to inclusive of collecting water sample in PVC container & submitting the same for testing.
Supply and fixing Chain pully of 2 ton capacity as per IS 3832 for lifting of borewell complete all as specified and directed.
S&F Elastomer Insulating Mats for Electrical Purposes Class A/voltage grade upto 3.3 KV (AC) as per IS : 15652:2006 with ISI mark of thickness 2.00 mm+ 10% of approx with 1 mtr along with suitable adhesive/chemibound resin waterproofing compound and sealing material all as per manufacturers' recommendations and as specified & directed. Make : Electromat/ Insulatica 2000 or equivalent.
Supply and fix tripod stand of capacity 3 Ton 18 feet long made out of MS pipe heavy grade complete all as specified and directed. Make: Hira Product Code 31743 or equivalent model in Taparia/Bosch
M&L for DI Fittings of class K-12 as per IS: 9523 / 2000 with Inside Cement Mortar lining (CML) with Slag Cement or Ordinary Portland Cement (OPC) and outside black bitumen coating like tee's bend sockets, collar's of juinctioning coupling etc of any type with rubber gaskets complete all as specified for sizes upto 200 mm dia CI/DI pipe line all as directed
Material, labour , testing & commissioning of cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 sqmm 3½ to 4 core with working voltage 1100 volts complete all as specified and as directed.
M/s. Public Tubewell Drillers Co
M/S SONI DRILLERS
JAGDISH SINGH ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .