SPECIAL REPAIR TO BLDG NO P-71 AT 262 TRANSIT CAMP OF OLD BASE HOSPITAL IN THE AREA OF AGE B/R-III UNDER GE (WEST) DELHI CANTT-10
2021_MES_481443_6
CWE/WEST-31/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE West Delhi Cantt
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE WEST DELHI CANTT
₹1.1 L
Yes
27 May 2022
22 Apr 2022
16 May 2022
22 Apr 2022
14 May 2022
30 Apr 2022
Amount
M&L for repairing of spalled concrete from ceiling in the following stages:- 1. Preparation of existing surfaces like chipping of unsound weak/loose concrete with electric hammer of manually including tapering all edges,making square shoulders of cavities etc.n.exc 50 mm thickness removal of debries,complete all specified and directed by the Engineer-in-charge. 2. Applying rust remover cum passivator Sika rustoff 100@ 0.20 Kg/Sqm/per coat or as per manufacturer's specifications to remove rust from existing reinforcement (Make : Sika or equivalent) 3. Applying a expoxy based zinc rich rebar corrosion protection system of products : Fiazin (R) R @ 0.15 Kg/Sqm/ coat or as per manufacturer's specification (Make : Sika or equivalent) 4. Mixing & applying two component Epoxy resin concrete Bonding coat of Sikadur(R)-32LP A & B @ 0.40 Kg/Sqm/(Mixing proportion as per manufactuer's instructions) on prepared RCC surfaces as per manufacture specification including preparaion of surface by chipping and throughly cleaning of surface complete whereever requrired over new reinforcement (if required) and as directed by the Engineer-in-charge (Make: Sika or equivalent) (Reinforcement will be measured and paid separately). 5. Apply a pre-batched one component polymer modified cementions patch repair mortar n. exc 50 mm in layer of 15 mm thick each of Product : Sika Mono Top -122 F as per manufacturer instructions and as directed.
M&L for providing rebar of required length & dia with Sika Anchor Fix - 3/ Mungo/FISV 390/Hilti RE-500 expoxy resin whereever required in RCC members including power drilling for holes(of size 16mmx160mm), cleaning of holes, fillled with epoxy to ensure the bond as per bond as per manufacturers instruction, complete all as specified and directed by the Engr-in-Charge. (Make : Sika/FosroC/Hilti Re-500 or equivalent)
M&L for applying one part plastio -elastic coating based on UV-curing acrylic dispersion with excellent crack-bridging properties, protective coating system to achieve DFT(Dry Film Thickness) of 150 microns in two coats after application of one coat of Silane Siloxane modified Primer on concrete surface including Surface preparation by high pressure water jet or manually as per direction of Engineer-In-Charge in recommended RAL Shades. Primer: Sikagard -551 S @ 0.2kg/m2. Coating: Sikagard - 550 W Elastic @ 0.2 Kg/m2/coat in 2 coats. (Make : Sika/Fosroc/Pidilitie or equivalent)
Making "V" groove of 15 mm wide and 15mm deep over crack line by electrically operated angle grinder with diamond concrete saw blade and cleaning it by air blower and sealing it with polymer modified mortar as directed by the Engineer-in-Charge (Make :Sika or equivalent)
Drilling and fixing NRV injection packers in RCC members including, (a) Drilling Holes: Drilling holes in structural members at the intervals as per recommenddation of engineer in charge. (b) Cleaning of holes: Clean the holes by air blower prior to fixing nozzles.Fixing of Packers: Insert 12 mm dia., 50-75 mm log injection packers in cleaned holes with solvent free, moisture insenstive epoxy resin based putty or equivalent. (c) Cutting or Packers: Cut the packers by cut of wheel after completion of grouting without damaging structural elements.
M & L for shrinkage free low viscous epoxy resin based injection grout. Product sikadur@-52 as per manufacture instructions and as per directed by the Enge in chargeMake:-Sika/Fosroc/pidilite or equivalent
M&L for mixing & applying two components epoxy resin concrete bounding coat of sikadur® 32 LP A&B @0.40 kg/Sqm(mixing propotions as per manufacture instructions ) on prepared RCC surface complete wherever required over new reinforcement (if required) and as directed by the Engineer -in-Charge.(Reinforcement will be measured and paid separately ). ( Make : Sika/Fosroc/Pidilite or equivalent)
Dismantling of brick tiles or terracing tiles single layer on roof complete all as specified & directed.
M&L for cement concrete tiles 25cmX25cmX22 mm thick macjine pressed set jointed and pointed in neat cement slurry with grey cement over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Demolition of mud phuska on roof slabs, any thickness including cleaning of roof surfaces and removing the debris upto the distance exceeding 1.00 Km but not exceeding 1.5 Km complete all as specified and diected.
Scrapping of old tar felt roof treatment over concrete padding of any thickness etc from roof including finishes or junction or parapet and cleaning the surface ( buy mechanical means like grinder etc ) complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (Using 20mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as specified and directed (Rate of WPC shall be included in this unit rate).
M&L for water proofing treatment in following stages:- 1. Rendering in CM 1:3 with waterproofing liquid as per manufacturer's instruction over concrete surface finished even and smooth without using extra cement. 2. First coat of bitumen primer confirming to IS-3384@ 0.40 Kg/Sqm over plastered surface.(Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd). 3. Second coat of binding material using blown type bitumen confirming to IS-702 Gde 85/25 @ 1.2 Kg/Sqm applied over bitumen primer. 4. Third layer of APP polymeric water proofing membrane, minimum 3 mm thick and weighing not less than 3.0 Kg/Sqm with a centre core of 90 micron high density polyethylene film protected on both sides with a high quality polymeric asphaltic mix, the polymeric asphaltic mix will be protected on both sides with thermo fusable HMHDPE film of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish.torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends complete all as specified and as directed. 5. Final coat of binding material using blown type bitumen confirming to IS-702 Gde 85/25 @ 1.2 Kg/Sqm applied over APP membrane. Over this layer stone dust @ 0.50 Kg/Sqm shall be applied uniformly.
M&L for providing cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) in roof ,kerb,mud slope rounder or chamfered on edges coping kerb water tough and like incl weathering ,slightly roundered or chamfered angles and thtroating directed incl necessary formwork complete all as specified and directed.
Taking down cement plaster from stone,bricks walls incl racking out joints,hacking for key and scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in ready mix plaster on fair face of brick work/ concrete surfaces and finished fair and even complete all as specified and directed.
M&L for rendering 15mm thick in cement plaster on fair faces of brick work or concrete surfaces in ready mix plaster with water proofing compound finished even and smooth surface without using extra cement complete all as specified & directed.Note:-WPC shall be measured and paid separately as supply only.
Material and labour for rendering 10 mm thick in ready mix plaster on concrete surfaces of ceiling etc and finishing the surfaces even and smooth without using extra cement including taking down old plaster complete all as specified and directed.
Supply only intergal water proofing compound.
M&L for preparation of newly plastered surfaces of walls and applying birla white putty min 1mm thick on wall even and smooth surface and applying two coat of oil bound distemper over a coat of alkali resistant (of approved quality and tint) on wall using painting roller complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior acrylic emulsion paint over a coat of alkali resistant primer incl min 1mm thick exterior wall care putty where ever directed.
M&L for complete removal of old existing treatment preparation of surface walls and applying two coats of exterior acrylic emulsion paint over a coat of alkali resistant primer incl 1 mm thick exterior wall care putty where ever directed EIC to level the undulations complete all as specified and directed.
M&L for complete removal of existing treatment by brooming down or steel wire brushing, scrapping down smoke, mass, efflorescent salt and oil and greesy spot etc. washing rubbing down distemper surfaces and applying birla white putty 1 mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as specified and directed.
S&F TMT bars 6mm to 8mm dia and over, cut to lenght, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as specified and directed.
Taking down chowkats or frames not exc. 1.5 sq. m with shutters (without taking off shutters from the frames) , complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 sq. m but not exc 4 sqm each with shutters (without taking off shutters from the frames) , complete all as specified and directed.
Dismantling of wall and ceiling boards(Fibre,pulp,insulation etc) or insulation boards/labs/blankets any thickness incl cover filters complete all as specified and directed
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S & F 35 mm thick 2nd class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated incl one shop coat of pink primer all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces over 10 cm in width or girth including preparation of new or previously untreated surfaces of wood complete all as specified and directed.
M&L for two coat of synthetic enamel painting on new steel surfaces over 10cms width or girth over a coat of red oxide primer including preparation of newly or previously untreated surfaces of steel complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles, complete all as specified and directed.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed.
M&L PCC 1:2:4 type B1 (20mm graded aggregate) as in anchoring hold fast, bed plate etc complete all as specified and directed.
S&F 100mm long PVC butt hinges for PVC doors complete all as specified and directed.
S&F 125mm long PVC handle for PVC doors complete all as specified and directed.
S&F 200mm long PVC tower bolt for PVC doors complete all as specified and directed.
S & F stainless steel butt hinges 100mm long medium weight etc complete all as specified and directed.
S & F 200mm long aluminum, anodized barrel tower bolts of extruded section complete all as specified & directed.
S&F 250mm long aluminium alloy,anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S & F aluminum anodised handle 150 mm long cast type complete all as specified and directed.
S&F floor door stopper 150mm of brass body and tongue, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F solid PVC Door Frame of size 50mm x 95mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F factory made solid PVC moulded door shutter 28 to 30mm thick(stiles) with 2,4 or 6 raised panel design with 2mm thick 3D wood grain moulded PVC sheet polyurethane painted on the front face & 2mm plain colour PVC sheet on back face complete all as specified and directed.
S&F in repair vitreous china single piece WC of size 690x360x640mm with softclose seat cover (PP), brass higes, fixing assessories set, cistern fittings, traps distance (MM) S-110, complete all as specified and directed (Make : Jaquar Cat Part No. SLS-WHT-0208BS for single piece WC and ZPS-WHT-1028 for seat cover or equivalent of Hindware)
S&F PVC connetion of size 15x600mm with PTMT nuts complete all as specified.
M&L for cast iron floor trap of 75mm dia,plain with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F cast iron gully trap 125/110mm, setting and jointing with cement concrete type B-1 (1:2:4) complete all as specified.
S&F Cast iron vent cowl of 100mm dia complete all as specified.
S&F for 100mm bore cast iron "P" or "S" trap complete all as specified.
S&F in repair for 15mm bore bib taps cast,copper alloy,chromium plated with capstan head hand with long shank &cup complete all as specified and directed.
S&F in repairs 15 mm bore angle valve, cast copper alloy screwed down high pressure with capstain head with long shank & cup complete all as specified and directed. Make-Hindware Cat No F-330039 or equivalent.
M & L for chromium plated toilet paper holder complete all as specified and directed. Make : Jaquar or equivalent of Marc/Ess Ess
M & L for hand shower (health faucet) (ABS chromium plated ) with 8mm dia, 1m long flexible tube and wall hook complete all as specified and directed. Make : Jaquar or equivalent of Marc/Ess Ess
M & L for chromium plated bottle trap (with internal partition ) 32mm size with 250mm and 190mm long wall connection pipes & wall flange complete all as specified and directed. Make : Jaguar or equivalent of Marc/Ess Ess
M & L for chromium plated jet spray including connection pipe comlete all as specified and directed. Make : Jaguar or equivalent of Marc/Ess Ess
S & F 15 mm dia two way angle valve cast copper alloy chromium plated with capstan head handle, screwed down high pressure screwed for iron pipe or for brass ferrule complete all as specified & directed.
S&F CPVC pipe 20mm internal dia with all fittings and fixed complete to walls ceilings or laid in floors of medium grade including dismantling old GI pipes complete all as specified and directed.
S&F CPVC 25mm internal dia with all fittings and fixed complete to walls ceilings or laid in floors of medium grade including dismantling old GI pipes complete all as specified and directed.
S&F of 1000 ltr capacity rotational moulded polythene water tank hoisted & fixed in position incl pvc float valve 20mm dia including dismantling old water tank complete all as specified and directed.
Dismantling floor hearth or wall tiling incl cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc set and joined in neat cement slurry and pointed in white or colour cement to match colour tiles including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for glazed ceramic coloured tiles (350x250x7mm/450x350x7mm ) thick on vertical surfaces such as skirting and dado set and joint in neat cement slurry and pointed in white or coloured cement to match including 10mm thick plastering in cement mortar 1:4 rough to receive tiles complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n.exc 15CM thickness (below or above ground level) complete all as specified and directed.
M&L for Plinth protection 75 mm thick in PCC 1:3:6 type C-1(using 20 mm graded crushed stone aggregate) laid in alternate bays(not exc 2 Sqm each) finished even and fair at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 graded and three parts of sand by weight complete all as specified and directed.
S&F 100mm dia cast iron (spun cast) soil, waste and vent pipe in any length with or without ears with lead joints laid in trenches or in floor including all fittings including demolition old CI pipes , complete all as specified and directed.
S&F 75mm dia cast iron (spun cast) soil, waste and vent pipe in any length with or without ears with lead joints laid in trenches or in floor including all fittings including demolition old CI pipes , complete all as specified and directed.
S& F Solid PVC Wall Lining Panelling consisting of 5mm thick wood grain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
Supply and fixing for aluminium powder coated sliding window made of the following specifications :- (Note : external size of window shall be measured. Following items are included in this unit rate.) (a) Aluminium frame powder coated all around of hollow section 100 mm x 44 mm x 1.60 mm thick. (b) Provn of 03 trade runners of size 92 x 31.75 x 1.10 mm. (c) Provn of glazed sliding shutters (02 Nos) of section 44 mm x 18 mm x 1.25 mm provided with 4 mm thick heat obseving glass with suitable EPDM beading and locking clips arrangement. (d) Provn of 01 No gauzed shutter of Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm with suitable EPDM beading arrangement of Section 44 mm x 18 mm x 1.25 mm . (e) Aluminium powder coated grill of weight not less than 1.60 Kg/Sqm on external side with suitable frame/aluminium runner to be fixed on the window frame. Note :- Opening for windod type AC shall be made in Alumunium window in Each room and rates if required shall deemed to be included in this item.
Dismantling loose concrete cover of RCC columns, beams, slabs, chajjas, and the like as directed, roughening and cleaning concrete surfaces with steel wire brushes, washed with water and allowed to dry, including derusting of steel reinforcement, providing fabric mild steel wire mesh 75mmx75mmx2mm dia as reinforcement to concrete surfaces, applying adhesive/admixture over steel mesh and providing 40mm thick (average thickness) guniting mix (using 1 part of cement and 2 parts of ghaggar sand mixed with adhesive/ admixture at the rate as directed) with a pressure of 2 to 2.5 Kg per sqcm by guniting machine and surfaces finished even and fair, including necessary padding, shuttering/ formwork, complete all as specified and directed (Guniting work is to be carried out upto 15m height). Notes:- Wherever steel reinforcement is required to be provided the same shall be measured separately under relevant item) (ii) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with brushes, washed with water and alloy to dry. To this surface apply chemistic polycrete admixture at the rate of 2% by weight of cement or all as per manufacturer’s instructions. (iii) When polymix coating is in tackey condition guniting is done with polycrete admixture at the rate of 2% by weight of cement or all as per manufacturer’s instruction. Polycrete admixture shall be procured from Chemical Adhesive Pvt Ltd Co or their authorized dealer. (iv) Cost of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. (v) Only steel shuttering/formwork to be used only.
M&L 18-20mm thick black granite of size in single pieces with full width of wall (tabled rubbed, polished and moulded) as in columns, steps, window cills and like laid over 15mm screed bed or plastering in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with the shade of granite including dismantling of stone slab complete all as specified and directed by the Engr-in-Charge.
M&L Reinforced cement concrete (1:11/2:3), type A-2 (using 20 mm graded stone aggregate), as in slab supported on wall, complete all as specified.
M & L for form work to soffits of suspended slab such as roof slabs, roof beams, chhajja, floor slabs cover slab, shelves, landings and similar works not exc 200mm thick finished rough (horizontal or sloping) rough finished surfaces complete all as specified and directed.
M&L for Brick work with sub class’B’ bricks having compressive strength of 100 kg/Sq cm straight or curved on plan to any radious in half brick thick walls built in cm 1:4 complete all as specified & directed.
S&F in repair grating doom 125mm dia of PTMT complete all as specified.
S&F in repair 20mm gun metal globe or gate valves with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed. .
S&F in repair vitreous china wash hand basin, white flat back, size 580 x 450mm excluding taps, waste pipe chain and plug and porcelain but including brackets, waste coupling complete all as specified and directed. Make: Parryware/Cera/Hindware
S&F in repair vitreous china squatting pan(Orrisa pattern ) long pan size 580x440 mm white with integral foot rest with P or S traps (excluding flushing cistern and flush pipe ) complete all as specified and directed.
S&F in repair looking mirror fitted to wooden plug with CP brass screws complete all as specified and directed.
S&F in repair chromium plated pillar tap fancy type with fly nuts capstan head screwed for 15mm dia pipe complete all as specified and directed.
S&F in repair flushing cistern 10ltr capacity syphonic action type low clevel with inlet ball valve ,float valve and handle including bracket,flushing pipe etc. complete all as specified and directed.
Chipping of unsound/ weak concrete material from slabs, beams, columns etc. with standard power driven percussion type or pneumatic chisel of standard make including tapering all edges, making square shoulders of cavities etc of average depth of 100mm complete and disposal of debris up for all lifts and leads complete all as specified and directed.
Cleaning of reinforcement from rust including from behind the reinforcing bars to give it a totally rust free finished steel surface by hammering the rebar, using wirebrushes, chiseling and using applyng rust remover cum passivator Sika rustoff 100 or requirement of Fosroc/ BASF @ 0.20 kg/Sqm/percoat with brush or as per manufacturer's specifications to remove rust from existing reinforcement and removing loose particles after 24 hrs of its application with wire brush and thoroughly washing with water and allowing it to dry, applying a epoxy based zinc rich rebar corrosion protection system @ 0.15 Kg/ Sqm/ per coat or as per manufacturer's instruction complete all as specified and directed.
Supply, mixing and applying bonding coat, including cost of material, on prepared non-metallic surface of parent material as per specifications and direction of Engr-in-Charge complete. SBR polymer ( @10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per Sqm of surface area with its proportion as specified and directed.
M&L for ready mix concrete (RMC) of design mix M-25 (using 20mm graded stone aggregate) as in slabs supported on walls and beams, roof slabs landings, balconies canopies, deck slabs and the like structure including necessary form work complete all as specified and directed.
M&L for cutting of upward facia/ fins 100-150 mm thick aprox 1.0 M height of RCC roof slab over building with diamond ctter and making good all disturbed surface in CM 1:3 and removalof rubbish ,debaries beyound MOD land complete all as specified and diretected by engineer in charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for concealed point wiring with PVC FRLS insulated multi stranded unsheathed cable 1.5 sqmm size with stranded copper conductor, 1100 volts grade conforming to IS-: 694 drawn in and including concealed PVC rigid conduits 20 mm dia incl cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed with concealed sunk in pressed steel terminal boxes of 1.6mm thick factory made and painted with stove enameled black paint covered with 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washers including single core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for the following :-
One light/fan/bell point controlled by one way switch 5 amps.
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
All as per item No. 91.00 here in before but with 2x2.5 Sqmm and 1x 2.5 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed
S&F of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
S&F of switch piano flush button type 15 amps single pole one way complete all as specified and directed.
S&F of socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
S&F of socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S&F in repair bell push flush type 5 amps complete all as specified and directed.
S&F of electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers all as specified and directed.
S&F of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed.
S & F in repair of decorative wall light fixture city-3 made up of polycarbonate, suitable for 15 watt LED bulb complete all as specified and directed. Cat part no- LHDL06160099 Make- Havells
Supply, laying and drawing in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 4.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking down all as specified and directed.
Taking down ceiling fan ,sealing cable end, dismantling blades and removing fan and blades and apply two coats of painting and numbering thereafter deposited to MES store yard for refixing complete all as specified and directed.
Hanging only celing fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.only celing fan and connector
S&F in repair of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. Including taking down of unserviceable MCBs complete all as specified and as directed.
Supply and fixing 40 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. Including taking down of unserviceable MCBs complete all as specified.
Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.including taking down of unserviceable lights complete all as specified and as directed.
S&F in repair of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and Single Pole MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F of MCCB 125 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burieddirectly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point and PCC CI cover.funnel with watering pipe wiremese,and copper lugs etc,GI protection pipe of size,test point extra length of main earthing lead 7.5 mtrs ,connectiong lead from last point to main switch or switch board.or equipment to be earthed on testing after complete the earth resistance and earth will be done at no extra testing on completion all as specified and directed.
S&F ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers including cutting suitable size of holes as directed in round shape including taking down old unserviceacble exhaust fans and deposited to MES store Yard complete all as specified and directed
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers including cutting suitable size of holes as directed in round shape including taking down old unserviceacble exhaust fans and deposited to MES store Yard complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
S&F in repair of single pole MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed.
Baljeet Builders & Interior Decorators
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .