COL SANTOSH PANDEY CWE(A) MUMBAI
Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
REPAIR/REPLACEMENT OF FIRE ALARM SYSTEM, FIRE HOSE REEL, DRUM, HYDRANTS, CONNECTED ITEMS AND PERIODICAL TESTING OF FIRE FIGHTING SYSTEM AT S AND T COMPLEX, TILOTAMA, MENAKA UNDER GE WEST COLABA MUMBAI.
2021_MES_431649_1
84016/W/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE (west) Colaba Mumbai
REFER THE TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (west) Colaba Mumbai
₹60,000
4 May 2021
18 Mar 2021
16 Apr 2021
18 Mar 2021
15 Apr 2021
3 Apr 2021
18 Mar 2021 - 8 Apr 2021
Amount
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at TILOTAMA Building (G+12) comprising following:- (a) fifteen Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections (d) Lead acid battery 12V/9AH Capacity. (e) 120HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) Testing of Electrical control panel of Fire Fighting System Water Pumps. (g) Testing of Pressure switch & Pressure Guage. (h) Testing of all Sluice Valve, NRV & Air Release Valve. P.M.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at MENAKA Building (G+12) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections. (d) Lead acid battery 12V/9AH Capacity. (e) 100HP Main Fire Hydrant Pump Servicing & Testing (01 Nos.). (f) 10HP Jockey Pump Servicing & Testing (01 No.). (g) Testing of Electrical control panel of Fire Fighting System Water Pumps. (h) Testing of Pressure switch & Pressure Guage. (i) Testing of all Sluice Valve, NRV & Air Release Valve.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at CHITRALEKHA Building (G+10) comprising following:- (a) fifteen Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections. (d) Lead acid battery 12V/9AH Capacity. (e) 100HP Main Fire Hydrant Pump Servicing & Testing (01Nos.). (f) 10HP Jockey Pump Servicing & Testing (01 No.). (g) Testing of Electrical control panel of Fire Fighting System Water Pumps. (h) Testing of Pressure switch & Pressure Guage. (i) Testing of all Sluice Valve, NRV & Air Release Valve.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at S & T COMPLEX Building (G+8) Both 02 wings comprising following:- (a) Ten Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections. (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (01 Nos.). (f) Testing of Electrical control panel of Fire Fighting System Water Pumps. (h) Testing of Pressure switch & Pressure Guage. (i) Testing of all Sluice Valve, NRV & Air Release Valve.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at Agastya Building (G+12) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections. (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) 10HP Jockey Pump Servicing & Testing (01 No.). (g) Testing of Electrical control panel of Fire Fighting System Water Pumps. (h) Testing of Pressure switch & Pressure Guage. (i) Testing of all Sluice Valve, NRV & Air Release Valve.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at Suvarna Building (G+6) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections. (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) 10HP Jockey Pump Servicing & Testing (01 No.). (g) Testing of Electrical control panel of Fire Fighting System Water Pumps. (h) Testing of Pressure switch & Pressure Guage. (i) Testing of all Sluice Valve, NRV & Air Release Valve.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at Brahmaputra Building (G+14) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections. (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) 10HP Jockey Pump Servicing & Testing (01 No.). (g) Testing of Electrical control panel of Fire Fighting System Water Pumps. (h) Testing of Pressure switch & Pressure Guage. (i) Testing of all Sluice Valve, NRV & Air Release Valve.
Supply only transformer AC/DC for fire alarm system panel of electronic type
Supply only battery duly charged 12 V, 7.2 AH. Make: EXIDE/Amron/Panasonic
Supply only Zone cards Make : HITESH/Gurutronic/Minal Engineer
Supply only power cards Make : HITESH/Gurutronic/Minal Engineer
Replacement of manual call point suitable for addressable system duly painted in red colour paint with front glass (to be broken in case of fire ) complete with test key to check the response with out breaking the glass and die cast aluminum housing with IFD indicator all as specified. Make : HITESH/Gurutronic/Minal Engineer
Supply only electronic hooters. Make : HITESH/Gurutronic/Minal Engineer
Detectors Complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination Photoelectric /Optical with base with self built intelligence as per IS: 11360. Make : APOLLO / MORLEY
Supply only hydrant valve wheel complete.
Supply only hydrant gun metal female coupling 63 mm dia
Supply only rubber hose drum adopter connection (shank reducer).
Supply only brass lock pin (lugs) for 63 mm dia.
Supply only hydrant valve spindle.
Supply only rubber hose pipe 20mm dia, plain 2 ply rayon braided high pressure. Make : DEEP JYOTI / DUNLOP
Supply only Aluminium nozzle suitable for 20 mm dia rubber hose pipe.
Supply only 100 mm sluice valve wheel.
Supply only brass hydrant valve nut as per existing size.
Supply only blank flange of size 100mm made out of MS 12 mm thick including flange joint.
Supply of PVC blank cap of hydrants with GI chain.
Supply & Fix Factory fabricated MS fire cabinet box as per give design made out flat CRCA of appropriate size and thickness all as directed including two coat of powder coated approved colour synthetic enamel paint over a coat of red oxide primer & fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle complete all as specified & directed by Engineer-in-Charge. Make-(a) LUXOL (Berger paint) (b) BROLAC (Johnson & Nicholson) (c) SUPERLAC (Shalimar Paints) (d) NEROLAC (Goodlass Nerolac) (e) APCOLITE (Asian Paints)
Supply and fix MS plate in short pieces of appropriate size & thickness required as per site requirement to existing fire cabinet box by means of welding including two coat of synthetic enamel paint (approved colour) over a coat or red oxide primer complete all as specified & directed by Engineer-in-Charge.
Supply only canvas fire hose 63mm dia bore 15 metre long confirming to IS Having male/female brass coupling both end complete all as specified.
Supply only brass Nozzle 25 mm bore suitable for 63mm dia canvas pipe complete all as specified.
Excavation in trenches n.ex.c 1.5 meter wide and n.exc 1.5 meter in depth for laying of pipe/cable etc and getting out in soft / loose soil.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Returning, filling is including spreading, leveling, watering and well ramming in layers n.exc. 25cms(Soil).
Cutting out concrete blocks, slabs, brickwork or stone masonry(in alternate course) forming toothings for and bonding new work in mortar into old work, including new materials entering old wall.
Taking down existing double acting valve of size 100 x 65mm for servicing including replacement of unserviceable spares ie gland, nut, bolt, lock pin, CI hand wheel with chain, etc complete and re-fixing in position in high rise bldg not exceeding 15 stories.
Supply & Fix Gun metal double acting fire hydrant valve of size 100 x 65mm conforming to IS – 5290/71 with all fitments such as cap cover instantaneous coupler for making flanged joint 100mm dia bore. Make- Leader, Kirloskar. L&T, Audco, Upadhyay, Zoloto, Advance
Repairing to MS front door of size not exceeding 1.5 mtr x 1.5mtr including welding locking arrangement including providing pad lock 50mm all as specified and as directed. Make : GODREJ/NAVTAL
Preparing old painted surface of CI/MS pipe 100mm dia and applying two coats of synthetic enamel paint (Red colour) including a coat or red oxide primer Make-(a) LUXOL (Berger paint) (b) BROLAC (Johnson & Nicholson) (c) SUPERLAC (Shalimar Paints) (d) NEROLAC (Goodlass Nerolac) (e) APCOLITE (Asian Paints)
Servicing of hose reel drums by applying greasing, oiling etc and making free rotation to hose drum all as specified and directed all as specified.
Removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer on fire fighting cubical box fitted inside bldg on each floor. Make-(a) LUXOL (Berger paint) (b) BROLAC (Johnson & Nicholson) (c) SUPERLAC (Shalimar Paints) (d) NEROLAC (Goodlass Nerolac) (e) APCOLITE (Asian Paints)
Supply and replacement, installation, testing & commissioning of Micro processor based 2 wire fault tolerant loop, required loop networkable type 5 Loop (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output. The Panel shall support 24 zones Addressable 2 way Talk Back fire fighter communication, in case of emergency. The panel shall have ability to get integrated with PA System for zone wise annoucements. The panel shall support both Loop Powered & conventional Notification devices for emergency responses. the Panel shall support Auto learn feature. The panel should support networking upto 99 panels with maximum distance of 12 Km between 1 & last & 1.5 KM between adjacent panels on RS485. Tha Panel shall support IP connectivity if requred to connect on LAN or WAN network. the panel shall support BMS connectivity through Bacnet/Modbus moduels. The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have 24 Zones with Individual LEd Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/ LPCB/ VDS/ UL/BSA complete all as specified and directed by Engineer-in-Charge, Voice Alarm controller with USB, MP3, AM/FM player )with 1000 watts Power Amplifier. Make :- Cease fire / Apollo / Hardik Engineer / Gurutronic
Supply & Fix in repairs MS pipes 100mm dia conforming to IS 1239 (Part-I) medium grade with both ends flanged and drilled with standard MS fitting including 02 coats of synthetic enamel painting over one coat of red oxide primer in any length and fixed on walls, complete all as specified and directed in high rise buildings Note : MS flanges including welding to MS pipes and all flanged joints shall be measured and paid separately under respective item of Sch ‘A’. Make- (a) Tata (b) Swastik (c) Jindal (d) Surya (e) Prakash (f) Indian Tube Company (g) Zenith (h) BST (j) GST (Gujrat Steel Tube)
Material and labour for MS flanges duly drilled including welding to MS pipes, nuts, bolts, washer etc complete all as specified.
Supply only Gun metal fire hydrant single acting of size 80x63mm for stand post. Make- Leader, Kirloskar. L&T, Audco, Upadhyay, Zoloto, Advance
Supply & Fix in repairs sluice valve, 100mm size, both ends flayed with high tensile brass spindle,cast iron body, as per IS-14826 & ISI Marked,PN-1.6 pressure rating including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified. Make- (a) Kirloskar (b) BIR (c) Leader (e) Upadhyay (g) L&T (h) BVI
S&F in repairs mild steel,conforming to Fe-410-0 or Fe-310-0,as in framed brackets of angles,cut to shape,drilled and counter sunk for screw including bending and welding as necessary guest plate, riveting complete.
S&F Non return valve, ball type, conforming to IS, Model B-05, of size 100mm. Make- Leader, Kirloskar. L&T, Audco, Upadhyay, Zoloto, Advance
Supply and fix in repairs FOOT valve, 150 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc. complete all as specified. Make- Kirloskar, Beacon, Leader, BIR, Venus, BVI
Supply, fixing and testing of 1.5 Sqmm x 6 Core Copper Armored Cable duly shaddled in walls, cable glands complete all as directed. Make- 1.Cable Corporation of India 2. Asian Cable Co 3. Finolex Cable Ltd 4. Polycab 5. Gloster 6. Universal 7. RPG Cables Ltd 8. Havells india ltd 9. RR Kabel 10. KEI Industries Ltd(KEI)
Minal Engineers
Shetty Construction Co
Hardik Engineers
M/S GLOBAL FIRE PROTECTION SYSTEM
Shree Ayyappa Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .