Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
31 Jul 2021, 6:00 pmClosed
GE Kapurthala
GE Kapurthala
Provn of Certain LBW, Special repair and Revenue works at Mil Stn Beas and Jandiala Guru under GE Kapurthala
2021_MES_417611_3
GE KPT-39/2020-21
Open Tender
Civil Works
Item Rate
270 days
Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kapurthala
₹96,000
2 Aug 2021
9 Jul 2021
2 Aug 2021
9 Jul 2021
31 Jul 2021
15 Jul 2021
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed by Engineer-In-Charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed by Engineer-In-Charge.
-Ditto- all as per item No 02 above but except bricks etc. Complete all as specified and directed by Engineer-In-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. Complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 on walls, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-In-Charge.
M & L for 15mm thick plaster in two layers (10mm+5mm) rendering in cement mortar 1:4 on other than fair faces of brick work and finishing surface even and smooth without using extra cement complete all as specified & directed.
M&L for 10mm thick rendering in cement mortar 1:3 on ceiling surfaces, finished surface even and smooth without using extra cement, complete all as specified and directed by Engineer-In-Charge.
M&L for Brick work with sub class 'B' bricks using old size bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
M&L for fly ash brick work using old size bricks built in cement sand mortar 1:6 , straight or curved on plan, exc 6m mean radius. Complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over and including a coat of chalk whiting/priming on plastered surfaces of walls, complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces and distempering walls with two coats of distemper oil emulsion, white or tinted over and including 1mm thick wall care putty including primer, complete all as specified and directed by Engineer-in-charge.
M&L for preparation of Newly plastered surfaces and applying two coats of White Wash over a coat of chalk whiting/priming on plastered surfaces of walls etc complete all as specified and directed.
M&L for three coat of white wash on plastered/unplasterd surface on ceiling including preparation of new plastered surface. Complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified & as directed.
Taking down chowkats or frames with shutters not exceeding 1.5 sqm each (without taking off shutters from the frames), complete all as specified and directed by Engineer-In-Charge.
Taking down chowkats or frames with shutters exceeding 1.5 sqm but not exceeding 4 sqm each (without taking off shutters from the frames). Complete all as specified and directed by Engineer-In-Charge.
M&L for framed work as in doors or gates and chowkhats of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening conforming to GdeFe 290(Gde E-165). Complete duly welded, bended and or molded all as specified and directed by Engineer-In-Charge.
S&F Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube and fixing in opening as per specification & drawing given in SSR 2004(Part-II) etc. Complete all as specified and directed by Engineer-In-Charge.
S&F Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width & stuck inside with solvent cement for stile and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing etc.Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 20 above but wire gauzed i.e. panel will be of wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly. Complete all as specified and directed by Engineer-In-Charge.
S&F 2nd class hard wood 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engineer-In-Charge.
S&F 2nd class HW 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F Mild steel pressed handles of size 150mm, oval type, stove enamelled black, complete all as specified and directed by Engineer-In-Charge.
S&F Extruded aluminium alloy handles, fabricated type, anodised 100mm size, complete all as specified and directed by Engineer-In-Charge.
S&F Extruded aluminium alloy handles, fabricated type, anodised 150mm size, complete all as specified and directed by Engineer-In-Charge.
S&F Mild steel barrel tower bolts 200mm long, stove enamelled black, with bright bolt and fixed, complete all as specified and directed by Engineer-In-Charge.
S&F 200mm long Aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engineer-In-Charge.
S&F 150mm long Aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engineer-In-Charge.
S&F Butt hinges 100mm size, medium weight, cold rolled mild steel, and fixed, complete all as specified and directed by Engineer-In-Charge.
S&F Mild steel sliding door bolts 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed by Engineer-In-Charge.
S&F 100mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed by Engineer-In-Charge.
S&F floor door stopper, overall length of cover plate 150mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed by Engineer-in-Charge.
S&F steel window 1.25mm thick box type (primer coated) ERW hollow P section of size 60mm x 25mm, 1.25 thick sheet single rebated comprises glazed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T-section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:2:4) type B-1 Four Nos for each window including following fitting welded to frame shutter : (a) Hold fast, 150mm long of 12mm square bar made to shape-04 Nos per window (b) Handles of z section 100mm long (c) Stopper - 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mm x 63mm welded to hinges - 01 No per leaf (e) MS Pintal hinges of size 75mm x 75mm x 12mm-02 Nos per leaf (f) Fabrication & fixing arrangement as per drg No CEJZ/TD-7/07 sheet 1/3 to 3/3. Note : Glass and painting shall be measured and paid separately under appropriate item etc complete all as specified and directed.
S&F steel window 1.25mm thick box type (primer coated) ERW hollow P section of size 60mm x 25mm, single rebated comprises gauzed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T-section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:3:6) type C-1 Four Nos for each window including following fitting welded to frame shutter : (a) Mild Steel Hold fast, 150mm long of 12mm square bar made to shape-04 Nos per window (b) Handles of z section 20mm x 100mm long (c) Stopper - 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mm x 63mm welded to hinges - 01 No per leaf (e) MS Pintal hinges of size 75mm x 75mm x 12mm-02 Nos per leaf (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note : Wire mesh and painting shall be measured and paid separately under appropriate item etc complete all as specified and directed.
S&F Steel Ventilator 1.25mm thick Box Type fixed type prepared for fixing of gauzed and glass ( primer coated) ERW hollow P section of size 60mm x 25mm including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each vent ) including following fitting welded to frame shutter: (a) Mild Steel Hold Fast,150mm long of 12mm Square bar made to shape – 04 Nos per vent (b) Handles of Z Sec 20mm x 100mm long (c) Stay (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note: Wire mesh/glass pane and painting shall be measured and paid separately under appropriate item etc. Complete all as specified and directed by Engineer-In-Charge.
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane, complete all as specified and directed by Engineer-In-Charge.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm, complete all as specified and directed by Engineer-In-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thicknness, including cover fillets, complete all as specified and directed by Engineer-In-Charge.
S&F anodised aluminium snap grid of size 605 x 605mm in frame work for false ceiling, complete all as specified and directed by Engineer-In-Charge.
Providing and fixing Gypsum Board 8mm thick of size (600x600)mm in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed by Engineer-in-charge (frame work for ceiling shall be measured and paid separately).
Dismantling taking down framed trusses of span not exceeding 10m, complete all as specified and directed by Engineer-In-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by Engineer-In-Charge.
Erection and fixing only steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240. Complete all as specified and directed by Engineer-In-Charge.
Erection and fixing only steel tubular work as in purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240. Complete all as specified and directed by Engineer-In-Charge.
S&F rolled sections (angle, pipe,tee, square pipe, plate etc) Fe-410-W(Gde E-250) quality-A, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates . Complete all as specified and directed by Engineer-In-Charge.
S&F steel work in tubular trusses including special shaped washer etc. Complete using ERW or induction butt welded tubes confirming to I.S.1161-1998 Grade St-240 complete all as specified and directed by Engineer-in-Charge.
Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings including ridges, complete all as specified and directed by Engineer-In-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-In-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-In-Charge.
S&F wind tie for roof including securing bolts: flat iron fillets including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe 410-0 or Fe 310-0 etc, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over and including a coat of red oxide primer. Complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of new wood surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed by Engineer-In-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness below or above ground level including tiles, terrazzo/stones etc. complete all as specified and directed by Engineer-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engineer-In-Charge.
M&L for joint free Non - skid Ceramic coloured tiles 7 to 8 mm thick square/ rectangular) laid over and including 15mm thick screed bed in cement mortar 1:4, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by engr-in-charge.
M&L for joint free non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:6. Complete all as specified and directed by Engineer-in-charge.
Ditto- all as per item No 60 above but as in skirtings, laid over and including 10mm thick rendering in cement mortar (1:4). Complete all as specified and directed by Engineer-in-charge.
M&L for coloured glazed ceramic tiles in vertical surface 300mm x 200mm & 7mm thick laid over and including 10mm thick screed bed in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified and directed by Engineer-In-Charge.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, complete all as specified and directed by Engineer-In-Charge.
M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 20mm thick cement screed base in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, treating the surface with bees wax polish, complete all as specified and directed by Engineer-In-Charge.
M&L for kota stone slab 20-25mm thick in riser of steps, skirtings, dado and pillar, laid over and including 15mm thick cement screed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, treating the surface with bees wax polish, complete all as specified and directed by Engineer-In-Charge.
M&L for grinding and polishing the kota stone flooring/skirting with machine grinder and treating the surface with bees wax polish, complete all as specified and directed by Engineer-In-Charge.
M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in plinth protection finished even and smooth (without using extra cement), complete all as specified and directed by Engineer-In-Charge.
M&L for sand filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering. Complete all as specified and directed by Engineer-in-charge.
M&L for 75mm thick cement concrete type C2 1:3:6 (40mm graded stone aggregate) in sub base. Complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick PCC 1:2:4 type B-1 with 20mm graded stone aggregate as in flooring, finished even and rough to receive the topping layer. Complete all as specified and directed by Engineer-in-Charge.
Surface dressing not exceeding 15cm deep and getting out in soft/loose soil. Complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5 m depth for foundation & getting out, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for plain cement concrete (1:4:8), type D-2, (using 40mm graded stone aggregates) in foundations, filling, mass concrete etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for Design mix M-25 concrete (using 20mm graded stone aggregate), as in Foundations, including rafts, footings, foundation beams; plinth beams; base for columns, etc.; basement slabs, under-reamed piles and mass concrete. Complete all as specified and directed by Engineer-in-Charge.
M&L for Design mix M-25 concrete (using 20mm graded stone aggregate), as in Columns, pillars, piers, posts and struts. Complete all as specified and directed by Engineer-in-Charge.
M&L for Design mix M-25 concrete (using 20mm graded stone aggregate), as in roof beams, cantilevers, bressummers, lintels upto and over 1.5 m clear span. Complete all as specified and directed by Engineer-in-Charge.
M&L for RCC design mix M-25 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. Complete all as specified and directed by Engineer-in-Charge.
M&L for RCC design mix M-25 (using 20mm graded crushed stone aggregate) as in suspended chajjas and the like. Complete all as specified and directed by Engineer-in-Charge.
Use & waste formwork to chullah hoods, chajjas, troughs and similar items including edges. Complete all as specified and directed by Engineer-in-Charge.
Use and waste formwork to square/reactangular sides of pillars, posts, struts, piers, columns, and stanchions fair and finished surface. Complete all as specified and directed by Engineer-in-Charge.
Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. Complete all as specified and directed by Engineer-in-Charge.
Use & waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping). Complete all as specified and directed by Engineer-in-Charge.
Use & waste formwork to sides and soffits of floor or roof beams, beam, RCC coping fair and finished surface. Complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm. Complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 6 to 8mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia. Complete all as specified and directed by Engineer-in-Charge.
-Ditto- all as per ser item No. 84 above but 5mm dia and over as in stirrups, spacers and binders. Complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete cast in situ Type B-1, 1:2:4 ( 20 mm graded stone aggregate) as in lintels upto 1.5m clear span including necessary formwork complete all as specified and directed by engr in charge.(Note : Reinforcement shall be measured and paid separately)
M&L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded stone aggregate) as in chajjas, complete all as specified and directed by Engineer-in-Charge.
Material and labour for pre-construction antitermite treatment by treating the bottom and sides of excavation at the rate of 5 litres of ATT emulsion per Sqm of surface area. Complete all as specified and directed by Engineer-in-charge.
Material and labour for pre-construction antitermite treatment by treating the back fill in contact with foundation at the rate of 7.5 litres of ATT emulsion per Sqm of vertical surface area in contact. Complete all as specified and directed by Engineer-in-charge.
Material and labour for pre-construction antitermite treatment by treating the top surface of filled earth at the rate of 5 litres of ATT emulsion per Sqm of surface area. Complete all as specified and directed by Engineer-in-charge.
Material and labour for pre-construction antitermite treatment by treating the soil under plinth ptotection at the rate of 5 litres of ATT emulsion per Sqm of surface area. Complete all as specified and directed by Engineer-in-charge.
Material and labour for pre-construction antitermite treatment by treating the soil alongwith external perimeter of bldg at the rate of 2.25 litres of emulsion per metre of the wall. Complete all as specified and directed by Engineer-in-charge.
M&L Hardcore of guage exceeding 63mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled/rammed to a true surface true surface. Complete all as specified and directed by Engineer-in-charge.
M&L for hardcore of broken bricks of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface. Complete all as specified and directed by Engineer-in-charge.
M&L for 40 mm thick Damp proof courses to horizontal or vertical surfaces in cement concrete 1:2:4, Tye B-0 including necessary formwork, complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
Returning filling in, including, spreading, levelling, watering, and well ramming in layers not exceeding 25cm. Complete all as specified and directed by Engineer-in-charge.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point. Complete all as specified and directed by Engineer-in-charge.
Spreading, leveling, watering and well ramming in layers not exceeding 25cm for soft/loose soil. Complete all as specified and directed by Engineer-in-charge.
S&F harrison rails, curtain rod of mild steel, chromium plated with fixing brackets, stops, rollers etc. Complete all as specified and directed by Engineer-In-Charge.
Dismantlling water tank of capacity exceeding 500 ltrs and not exceeding 1000 ltrs and removing to store of any description. Complete all as specified and directed by Engineer-In-Charge.
S&F rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified including 20mm dia ball brass valve, complete all as specified and directed by Engineer-In-Charge.
S&F rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified including 20mm dia ball brass valve complete all as specified and directed by engr-in-charge.
S&F vitreous china squatting pan (Orissa pattern), size 580 x 440mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding as in repairs, complete all as specified and directed by Engineer-In-Charge.
S&F vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging devices with recessed bottom, jet spray, etc. Complete all as specified and directed by Engineer-In-Charge.
S&F Low Level Flushing cistern PVC valveless syphonic action type, 10 ltrs capacity including supply pipe & fixing brackets of M.S. angle of size (25mmx25mmx3mm), 30 cm long in PCC (1:2:4) type B-1, block of size (10cmx10cmx10cm) on walls, as in repairs etc. Complete all as specified and directed by Engineer-In-Charge.
S&F Vitreous China Wash Basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or eracting stand & waste pipe, coupling etc as in repairs, complete all as specified and directed by Engineer-In-Charge.
S&F in repairs, waste coupling, bore dia of discharge pipe 32mm of PTMT (half or full threaded) (Minimum weight 45gms), complete all as specified and directed by Engineer-In-Charge.
S&F waste coupling, bore dia of discharge pipe 32mm of PTMT (half or full threaded) (Minimum weight 45gms), complete all as specified and directed by Engineer-In-Charge.
Supply only 15mm dia Pillar taps, cast copper alloy with capstan heads Chromium Plated, screwed down high pressure, with or without lettered with long screwed shanks and fly-nuts, screwed for iron pipe but fancy type and fixed etc. Complete all as specified and directed by Engineer-In-Charge.
S&F CP soap dish, any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed by Engineer-In-Charge.
S&F PVC connection 15mm size with PTMT nuts of length 450mm etc. Complete all as specified and directed by Engineer-In-Charge.
S&F 15mm dia angle stop valve of PTMT any colour pressure screwed for iron pipe and fixed (minimum weight 15mm - 90 gms) as in repairs, complete all as specified and directed by Engineer-In-Charge.
S&F 15 mm dia angle stop valve of PTMT any colour pressure screwed for iron pipe and fixed (minimum weight 15mm - 90 gms), complete all as specified and directed by Engineer-In-Charge.
S&F 15mm dia stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 15mm - 90 gms) as in repairs, complete all as specified and directed by Engineer-In-Charge.
S&F 15mm dia fancy type, chromium plated with long shank and cup (concealed type) stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer-In-Charge.
Taking up or down steel tubing and connections and removal to store, bore of pipe 15mm. Complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections and removal to store, bore of pipe 20mm. Complete all as specified and directed by Engineer-in-Charge.
S&F Steel Tubes Medium Grade Bore of tube in 15mm galavanised with all fitting laid in trenches, walls, ceiling or laid in floors etc.Complete all as specified and directed by Engineer-In-Charge.
All as per item No 121 above but of size of 20mm bore. Complete all as specified and directed by Engineer-In-Charge.
S&F gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to steel pipe or union, 20mm bore dia of pipe complete as in repairs. Complete all as specified and directed by Engineer-In-Charge.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to steel pipe or union, 20mm bore dia of pipe, Complete all as specified and directed by Engineer-In-Charge.
S&F Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union. Complete all as specified and directed by Engineer-In-Charge.
S&F Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union as in repairs. Complete all as specified and directed by Engineer-In-Charge.
S&F, Hand Shower (Health Faucet) with 1 Meter Long Easy Flex Tube in Chrome Finish and Wall Hook with N.R.V (Back Flow Preventer) with clamp (Cat Part No. ALD-CHR-563 of Marc or equivalent of Jaquar)
S&F PVC (SWR) P trap 100/110mm bore. Complete all as specified and directed by Engineer-In-Charge.
S&F 110mm bore PVC (SWR) bends any radius, complete all as specified and directed by Engineer-In-Charge.
S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer-In-Charge.
S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls as a vent pipe, complete all as specified and directed by Engineer-In-Charge.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed by engr-in-charge.
M&L for PVC (SWR) floor trap, plain with grating 75mm diameter of outlet, setting and jointing with solvent cement complete all as specified and directed by engr-in-charge.
S&F grating doom 125mm dia with waste hole of PTMT (minimum weight 40 gms) etc complete all as specified and directed by engr-in-charge.
S&F 75 mm bore PVC (SWR) vent cowl, complete all as specified and directed by Engineer-In-Charge.
S&F 110mm bore PVC (SWR) WC connector with lip ring, complete all as specified and directed by Engineer-In-Charge.
S&F 15mm dia fancy type chromium plated bib tap cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe and fixed to 15mm bore pipe fixed including taking down old tap of any description, complete all as specified and directed by Engineer-In-Charge.
S&F 15mm dia Chromium plated bib tap cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe and fixed to 15mm bore pipe fixed as in repairs including taking down old tap of any description, complete all as specified and directed by Engineer-In-Charge.
M&L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-In-Charge.
Excavation in post holes(or similar holes ) each not exceeding 0.50 Cum, and getteing out, returning filing in and ramming earth with broken rubble mixed with earth around in layers not exceeding 25cm, watering etc and removing surplus soil not exceeding 50m and making good surface in loose/soft soil, complete all as specified and directed by Engineer-In-Charge.
M&L for Cement concrete type C-2, 1:3:6 (40mm Graded agg) as in foundation, filling and mass concrete, complete all as specified and directed by Engineer-In-Charge.
S&F MS Pipes as in vertical posts, fixed with angle cleats or other connecting plates, rivets ,nut bolts etc, complete all as specified, conforming Fe 410W (Gde E-250) Quality B.
S&F MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate. complete all as specified and directed by Engineer-In-Charge.
Cutting chases, pinning in, making good to facinngs where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth complete all as specified and directed.
Use and waste formwork to shelves including supports,overhangs, etc also splays between floor and beams complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 Type B-1 ( 20 mm graded stone aggregate) as in bed blocks, coping, etc. Complete all as specified and directed by Engineer-In-Charge.
Preparation of new concrete surfae and apply water proofing treatment to roof with APP (Atactic poly propylene) modified prefabricated five layer 3mm thick water proofing membrance super therolay of STP limited wth non-woven polyster male reinforcement of 160gm, weight of membrane @3.6kg/sqm over a solvent based bitumen primer, shalitex primer @ 0.3 lt/sqm by the same manufacturer conforming to IS-3384-1986.Apply two coat of alumnium paint on top of membrane surface after laying the membrane incl all cleaning Note : The membrane shall be laid using butane torch. The end lap should be 100 mm and the side lap must be minimum 75 mm. The membrane shall be first laid upto the parapet wall junction and then shall be overlapped with naother membrane (flashing) with and overlap covering upto a distance of 300mm. In case of parapet height is less than/ upto 500 mm membrane shall be terminated at the top of parapet. (Water ponding test should be carried out for 72 hrs of water proofing treatment).
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil. Complete all as specified and directed by Engineer-in-Charge.
M&Lfor soling with broken boulders or quarried stone (granite/trap/basalt) 75mm spread thickness interstices filled, surface formed and rolled and consolidated to required gradient and camber, complete all as specified and directed by Engineer-in-Charge.
M&Lfor broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layer not exceeding 12 cm thick, watered and rammed to true surface. Complete all as specified and directed by Engineer-in-Charge.
M & L 100 mm thick cement concrete 1:4:8 type B–2 using 40mm graded stone aggregates as in flooring finished even and smooth without using extra cement all as specified and directed by Engineer - in - Charge .
M&L for 75mm thick cement conc type C2, 1:3 :6 (40mm graded stone aggregate) as in sub base. Complete all as specified and directed by Engineer-in-Charge.
M&L for Machine pressed precast concrete interlocking paver block, 60mm thick, any shape and size, confirming to IS-15658-2006, M-35 Grade, with grey cement and no pigment complete all as specified and directed.
(a) Performing 'Standard Penetration Test (SPT)' where directed, as per IS:2131 by sinking bore hole, 125 to 150mm dia upto a depth of 7m below GL or refusal whichever is earlier. Collecting samples at every 0.5m and reporting their index properties. Carrying out "Triaxial compression Test" on rthe samples collected, reporting their 'C-Ø' characteristics, and working out and reporting 'Safe Bearing Capacity (SBC) at various depths at intervals of 0.5m based on "Triaxial Compression Test and SPT". The data shall be properly presented showing bre log charts, site plan, calculations and clear recommendations on SBC of soil. The complete report shall be submitted in duplicate. NOTE :- 1. The rates quoted inclusive of the cost of three photographs per each hole in presence of MES staff, when the work is being carried out and including the same in the report.
Rough excavation not exceeding 1.5m deep and getting out in hard dense soil. Complete all as specified and directed by Engineer-In-Charge.
M&L for construction of soakage well including excavation, in any type of soil, foundation in PCC 1:3:6, wells of honeycombed masonary with top ring of M-25 Concrete, including intercepting chamber and screen chamber brick work in CM, RCC cover slabin M-25/SFRC cover including reinforcement with 12mm TMT bar & 6mm dia stirrups, interconnecting pipe of RCC/DWC complete filled with brick bats, complete of size 1.8m dia X 3m effective depth. Complete all as specified and directed by Engineer-in-Charge.
Supply & lay in position on site Hume pipe septic tank designed to carry sewage and sullage water, including excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc. complete for 10 users, complete all as specified and directed by Engineer-in-Charge.
Supply & lay 150mm bore reinforced concrete pipes, class NP3, laid and jointed complete with collars,complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6 type C-2 as in concrete bed to drain pipes for bore dia of 150mm including packing under, and haunching against the sides of pipes after they are laid and tested; in, complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class 'B' bricks using old size bricks straight or curved on plan exceeding 6m mean radious built in CM 1:4 etc complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type B-1, 1:2:4 (20mm graded stone aggregate as in surface channels and drains, complete all as specified and directed by engr-in-charge.
M&L for precast cement concrete type B-1, 1:2:4 as in cover slabs over drain/manholes etc. including necessary formwork, complete all as specified and directed by engr-in-charge.
Taking down carefully aluminium point wiring on casing caping/through conduit (light fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, regulators, box type tube light fittings, removing the materials from site except fittings etc which shall be reused in the work and making good the disturbed surfaces of walls/ceiling/ floors etc complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring for one light or one fan point controlled by one switch or with one switch and regulator with PVC unsheathed single core multistranded copper conductor (FRLS) cable of size 1.5 Sqmm (nominal area) in and including PVC conduit 20 mm bore by cutting chases in wall by cutter and making good the surface in cm 1:3 and to the original specification and cast iron /pressed steel concealed terminal boxes including providing 3mm thick plastic laminated sheet cover (Hylem) including one run of PVC insulated copper conductor (FRLS) cable of size 1.5 sqmm with green insulation as earth wire and connected to earth dolly complete all as specified. (Switch/Socket outlet to be measured & paid for separately). Make of cable: Finolex/Anchor/Havell’s
All as per Srl item No 164here in before but for 3 pin socket outlet 5 Amps on same board.
All as per ser item 164 above but for 3 pin socket out let 5 Amps on independent board.
All as per srl item No 164 here in before but for 3 pin socket outlet 15 Amps on independent board with PVC unsheathed copper conductor cable of size 2.50 Sqmm including copper earth wire of size 1.50 Sqmm and connected to common earth dolly complete all as specified. (Switch/socket to be measured & paid for separately)
Supply & fixing switch piano flush type 5 Amp single pole one way. Complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing switch piano flush type 15 Amp single pole one way.
Supply & fixing socket outlet 5 pin 5 Amps flush type multipurpose.
Supply & fixing socket outlet multipurpose 2 in one, 3 pin 5/15Amps flush type.
Taking down old unserviceable FTL fitting 36/40Watt and S & F surface mounting energy saving LED tube light fitting/ Batten with LED T8 Tubelight with PC body, 1x20W, 230V , Cat Part No of Batten DMLN1LT8-16 & Cat Part No LT8-20-865-2 for LED T8 Tube light Make- Crompton or equivalent complete with all accessories. Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB single pole 6 to 32 Amps 240 Volts, B Series Product Code CSMBS1B6 to CSMBS1B32 Make- C&S or equivalent in Havells/GE/ L &T/Legrand. Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB single pole 32 Amps 240 Volts SPN , B Series Product Code CSMBS1B6N to CSMBS1B32N Make- C&S or equivalent in Havells/GE/L&T/Legrand). Complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing sheet metal enclosures with double door, detachable gland plates flush/ mounting for MCB’s fitted with bus bar, earth wire and neutral link, 8 ways, 240 volts. ( Make- Havells/Legrand). Complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing sheet metal enclosures single door, detachable gland plates flush/ mounting for MCB’s fitted with bus bar, earth wire and neutral link, 4 ways, 240 volts. ( Make- Havells/Legrand). Complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing sheet metal enclosures DB Single Pole and Neutral 4 way with double door, detachable gland plates flush/ mounting for MCB’s fitted with bus bar, earth wire, 220 volts including taking down of existing DB at site all as specifed and directed.. Make-Havells/L&T/Indo Asian
Supply & fixing ceiling rose surface bakelite 65 x 50mm three terminal complete all as specified and as directed by Engineer-in-Charge. Make – Anchor/Leader/Bajaj
Supply & fixing Angular lamp holder insulated body with back plate suitable for batten fittings including 1 x 9 W LED Lamp Make- Havells LED ADORE 9 W B22 WW 3 STAR LAMP Cat No LHLDEUEEMC8R009 or equivalent all as specified and directed by Engr in Charge.
Supply & fixing Angular lamp holder insulated body with back plate suitable for batten fittings with 1 x 9 Watt LED lamp of approved make . ( Make-Anchor/SSK/Bajaj). Complete all as specified and as directed by Engineer-in-Charge.
Hanging only ceiling fan retreaved from Srl No 1, and connecting up including provision of flexible copper conductor cable from ceiling rose / connector to fan and GI pipe/ steel rod, nuts, bolts, clamps etc as required at site all as specified and directed by Engr-in-charge.
Supply and fix Economy Plain Ceiling fan 1200 mm sweep, 240 Volts Colour- Opal White Make- Crompton Model Cool Breez or equivalent in Bajaj/Havells/Orient, and connecting up including provision of flexible copper conductor cable from ceiling rose / connector to fan and GI pipe/ steel rod, nuts, bolts, clamps etc as required at site all as specified and directed by Engr-in-charge.
Supply & fixing fan regulator electronic step type and making connections. (Make : Anchor/Leader/Bajaj). Complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix Metallic exhaust fan 150 mm sweep, 240 Volts Colour- Grey Make- Crompton Model Transair 6" single phase ,230/240 V,AC including making of hole on wall for passing out air and provision of flexible three core copper conductor cable of 23/0.0076 up from ceiling rose to fan and grouting 04 Nos bolts in wall. Complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix exhaust fan 250 mm sweep, PVC Body, single phase ,230/240 V,AC with louvers including making of hole on wall for passing out air and provision of flexible three core copper conductor cable of 23/0.0076 up from ceiling rose to fan and grouting 04 Nos bolts in wall. Complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix in replacement Metallic exhaust fan 150 mm sweep, 240 Volts Colour- Grey Make- Crompton Model Transair 6" single phase ,230/240 V,AC including making of hole on wall for passing out air and provision of flexible three core copper conductor cable of 23/0.0076 up from ceiling rose to fan and grouting 04 Nos bolts in wall. Complete all as specified and as directed by Engineer-in-Charge.
S&F surface mounting energy saving LED tube light fitting/ Batten with LED T8 Tubelight with PC body, 1x20W, 230V , Cat Part No of Batten DMLN1LT8-16 & Cat Part No LT8-20-865-2 for LED T8 Tube light Make- Crompton or equivalent complete with all accessories. Complete all as specified and as directed by Engineer-in-Charge.
Supply and fix LED self ballasted fitting 20 watt extruded aluminium body with PC diffuser 240 degree wide distribution Cat part No PCGLB DLX 20 30 Product Code LDO0103106 of Make : Polycab or equivalent in C&S electric cat part No LTDC30120WLED/WD and Crompton Greaves cat Part No DMLN1LT8-16 for Box type fitting and LTT8-20 for LED rod 20 watt along with all accessories, pre-wired fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed by Engineer-in-charge..
M&L of earthing complete with galvanized steel earth plate trode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level connected to GI earth wire 4mm dia by means of bolts, nuts and washers (earth plate covered with charcoal dust and common salt in alternate layers) GI earth wire protected by galvanized steel pipe light grade of 15 mm dia upto switch board and connected to main switch board, including provision of 20mm dia GI tubing light grade watering pipe with funnel and wire mesh PCC earth pit (1:3:6) type C-1 covered with CI cover hinged with frame including excavation and earth work complete all as specified and shown in electrical plate No 5 of SSR Part I including testing on completion.
Supply and fixing in replacement sub main wiring with two single core FRLS insulated cable with copper conductor stranded and sheathed of size 6 Sq mm in and including PVC conduit including 1 x 6 Sq mm FRLS copper earth wire to common earth and connected to earth dolly complete all as specified and directed. Make of cable : Finolex/Havells/Plaza/Indo Asian
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for ltaking out old cable/laying of under ground cable/foundation of poles/stays including segregation of old serviceable bricks complete all as specified and directed by Engineer-in-Charge.
M&L for brick protection using old size sub class 'B' bricks, laid flat dry but adjoining to each other laid lengh wise perpendicular to the axis of cable complete all as specified and directed.
Supplying, filling in trenches spreading, leveling sand cushioning 8 cm below and 15 cm above the cable for under ground cable complete all as specified & directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core. Complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core. Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED bldg security light fitting 15 watt Powder coated pressure die cast aluminium compact LED security light including 1.5 mtr long 40 mm bore GI pipe mounting bracket made to shape for fixing on wall with 40 mm x 6 mm flat iron clamp 02 numbers with 16 mm dia bolts, nuts and washers all as specified and directed by Engineer-in-Charge.Make- Crompton Cat Part No LSTS-15-CDL or equivalent in Bajaj/Philips/C&S/Havells : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
M/L for GI Pipe 'light grade' galvanized with all fitting laid in trenches/on pole/road crossing of size 40mm. Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED Recessed full open 2 x 2 Tile 36 Watt,glare free uniform illumination having white powder coated extruded aluminium body suitable for armstrong and grid ceiling Product code LCTLRN-36-FO-CDL (Polaris I) of Crompton or equivalent in Bajaj/Havells/C&S/Halonix/Polycab. Complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix PVC Ventilation Fan 150 mm sweep, 240 Volts Colour- White Make- Crompton Model Mountair 6" single phase ,230/240 V,AC including making of hole on wall for passing out air and provision of flexible three core copper conductor cable of 23/0.0076 up from ceiling rose to fan and grouting 04 Nos bolts in wall. Complete all as specified and as directed by Engineer-in-Charge.
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated
S&F PLUG AND SOCKET ENCLOSURES IN SHEET STEEL ENCLOSURES (WITHOUT MCBs) Cat No DSDPUSN020 Make- Standard or equivalent in Havells/L&T/Legrand
S&F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or round of 10 sqmm cable. Complete all as specified and as directed by Engineer-in-Charge.
S&F House service bracket (Hook type) complete with 3.0 Mtr long G.I pipe 40mm dia Med grade two Nos 90 degree bends, MS hooks and stay or guy. Complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated. Complete all as specified and as directed by Engineer-in-Charge.
Gurjit const co
s.v and co
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .