Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹96.8 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | 1 | Accepted-AOC L1 | |
| 2 | 2₹1.1 Cr+₹7.4 L (7.44%)Rejected-Finance H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | 2 | Rejected-Finance OTHER THAN L1 | |
| 3 | 3₹1.1 Cr+₹7.8 L (7.88%)Rejected-Finance | 3 | Rejected-Finance OTHER THAN L1 | |
| 4 | 4₹1.2 Cr+₹18.1 L (18.2%)Rejected-Finance 5C H M APARTMENT SATI JAYMATI ROAD ATHGAON KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | 4 | Rejected-Finance OTHER THAN L1 | |
| 5 | 5₹1.4 Cr+₹43.5 L (43.7%)Rejected-Finance | 5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
21 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE SHILLONG
HQ CWE SHILLONG SE FALLS SHILLONG MEGHALAYA - 793011
IMPROVEMENT OF HT ELECTRIC SUPPLY SYSTEM AT NARANGI UNDER GE NARANGI
2021_MES_433453_1
8466/NAR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NARANGI
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE NARANGI
₹2.2 L
Yes
8 May 2021
1 Apr 2021
23 Apr 2021
1 Apr 2021
21 Apr 2021
14 Apr 2021
60 days
Amount
Taking down unserviceable/old ACSR conductor any size from over head lines, poles by removing binding wire and removal from site complete all as specified and directed.
M & L for Dismantling unserviceable cross arms, clamps etc and removal from site complete all as specified and directed.
M & L for Dismantling insulator any type, any size from HT poles and removal from site complete all as specified and directed.
Dismantling old steel pole/struts any size and removal from site complete all as specified and directed.
Dismantling old concrete pole/struts any size and removal from site complete all as specified and directed.
Dismantling stay assembly complete, and removal from site complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil all as directed.
M & L for Returning filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick for any type of soil all as specified and directed by Engr-in-Charge.
M & L for Removing surplus soil to a distance not exceeding 50m and depositing at level not exceeding 1.5m above the starting point all as specified and directed by Engr-in-Charge.
M&L for sand cushining / sand covering for under ground cable protection and consolidated and compacted with clean dry sand complete all as specified and directed by Engr-in-Charge.
Supply and laying un-reinforced precast concrete cable cover class HV type-1 of flat size 300mm x 180mm x 40mm complete in trenches all as specified and directed.
M & L Manual boring under road, pavement hard standing by required T&P without disturbing the top surface of the road for throughing the cable in GI Pipe of 80 mm dia all as specified and directed.
Supply and laying 80 mm bore GI pipe light grade with all fittings laid in trenches for cable protection complete all all as specified and directed by Engr-in-Charge.
Supply and fix cable jointing kit for 11 KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 Sqmm all as specified and directed. Make: 3M/Raychem/Denson.
Supply and fix cable jointing kit for 11 KV grade cable for in door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 Sqmm all as specified and directed. Make: 3M/Raychem/Denson..
Supply and fix cable jointing kit for 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm all as specified and directed. Make: 3M/Raychem/Denson.
Supply, laying, connecting and testing XLPE HT UG insulated (Earthed) cable laid in trenches/or fixed on pole etc. with screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 Volt grade, cross sectional area 95 Sqmm, 3 Core conforming to IS-7098 (Part-II)-1985 complete all as specified and directed. Make :Havells,Gloster cables Ltd, KEI, Asian, CCI Polycab, Finolex. Notes: (i) Excavation & earth work will be measured and paid separately.
S&F cable route indicator with precast RCC slab 1:1.5:3 type A using 20 mm graded aggregate of size 75 cm X 30 cm X 75 mm thick duly embossed with "MES HT Cable" on the route of cable with PCC foundation all as directed by Engr-in-charge. Note: - Cost of of earthwork, PCC foundation 8mm dia TMT bar (5 Nos of bar along the length & 9 Nos of bar along width) painting the route indicator slabs with red color synthetic enamel paint deemed to be included in quoted rate .
Supply, intallation testing & commisioning of 630 Amps, 21kA for 3 Sec, non-extensible IP-55 outdoor type SF6 gas insulated 630 Amp aluminium busbar Ring Main Unit (RMU) comprising of 2 load break switch and 01 outgoing VCB as details below. The LBs/VCB shall be enclosed in robotically welded minimum 2 mm thick non -magnetic, non ferrite stainless steel tank filled with SF6 Gas & IP Class IP-67, leak rate less than 0.1%and tested as per latest IEC 62271-200 international standards. The unit shall have side & rear cable entry for ease of installation. VCB should preferable have 5000 operations or more to meet frequent fault condition. RMU should be tested for internal arc test of 21kA for 1Sec. The unit shall include the following with all necessary standard fitting required at site including provision of necessary foundation with PCC (1:3:6), type C-2 complete all as specified and directed. Make : L& T , Schneider/Siemens/ABB/CG. NOTE: - Auxiliary supply for RMUs ie 220 volt AC with 2.5 sqmm PVC insulated unsheathed single core FRLS two run multistranded copper conductor cable 1100 Volt grade drawn through in and including non metalic PVC conduit (ISI marked) of adequate size from nearby LT panel (Max 20 Mtr) included in quoted rate.
(a) Load break switch module - 2 nos (i) Manually operated 12kV, 630 A Load Break switch and Earthing switch with making capacity. (ii) Live cable Led indicators through capacitor Voltage Dividers mounted on the bushings. (iii) Earth fault passage indicator one per LBS. (iv) Mechanical ON/OFF/Earth indication (v) Cable testing facilty without opening the cable covers and without disconnecting the cable termination.Separate test bushings shall be integral part of RMU to carry out cable testing at load Break switch. (vi)Cable door should be arc proof and interlocked with respective earthing switches. For safety of operator it should not be possible to open the cable door unless the earth switch is ON.
(b) Vaccum Circuit Breaker module - 1 nos (i) Motorised operated 630 A Vaccum Circuit Breaker and Earthing Switch with making capacity and having power pack. (ii)Mechanical ON/OFF/EARTH/Spring Charge indication (iii)Live Cable LED indicators through Capacitor Voltage Dividers mounted on the bushings. (iv)3 O/C + 1 E/F self powered relay with LCD display & with Low and High set for Over current and Earth fault (v) GREEN (Close)/RED (Open) push buttons for VCB operation (vi)Protection CT 50/1 A, 2.5 VA , 5P10 or as per actual Transformer full load current
Supply, intallation testing & commisioning of 630 Amps, 21kA for 3 Sec , non-extensible IP-55 outdoor type SF6 gas insulated 630 Amp aluminium busbar Ring Main Unit (RMU) comprising of 2 load break switch and 02 outgoing VCB as details below. The LBs/VCB shall be enclosed in robotically welded minimum 2 mm thick non -magnetic, non ferrite stainless steel tank filled with SF6 Gas & IP Class IP-67, leak rate less than 0.1%and tested as per latest IEC 62271-200 international standards. The unit shall have side & rear cable entry for ease of installation. VCB should preferable have 5000 operations or more to meet frequent fault condition. RMU should be tested for internal arc test of 21kA for 1Sec. The unit shall include the following with all necessary standard fitting required at site including provision of necessary foundation with PCC (1:3:6), type C-2 complete all as specified and directed. Make : L& T , Schneider/Siemens/ABB/CG. NOTE: - Auxiliary supply for RMUs ie 220 volt AC with 2.5 sqmm PVC insulated unsheathed single core FRLS two run multistranded copper conductor cable 1100 Volt grade drawn through in and including non metalic PVC conduit (ISI marked) of adequate size from nearby LT panel (Max 20 Mtr) included in quoted rate.
(a) Load break switch module - 2 nos (i) Manually operated 12kV, 630 A Load Break switch and Earthing switch with making capacity. (ii) Live cable Led indicators through capacitor Voltage Dividers mounted on the bushings. (iii) Earth fault passage indicator one per LBS. (iv) Mechanical ON/OFF/Earth indication (v) Cable testing facilty without opening the cable covers and without disconnecting the cable termination.Separate test bushings shall be integral part of RMU to carry out cable testing at load Break switch. (vi)Cable door should be arc proof and interlocked with respective earthing switches. For safety of operator it should not be possible to open the cable door unless the earth switch is ON.
(b) Vaccum Circuit Breaker module - 2 nos (i) Motorised operated 630 A Vaccum Circuit Breaker and Earthing Switch with making capacity and having power pack. (ii)Mechanical ON/OFF/EARTH/Spring Charge indication (iii)Live Cable LED indicators through Capacitor Voltage Dividers mounted on the bushings. (iv)3 O/C + 1 E/F self powered relay with LCD display & with Low and High set for Over current and Earth fault (v) GREEN (Close)/RED (Open) push buttons for VCB operation (vi)Protection CT 50/1 A, 2.5 VA , 5P10 or as per actual Transformer full load current
M&L for earthing complete with copper earth plate electrode 60 cm x 60cm x 3.15 mm buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with the top edge not less than 1.5 mtr below ground level connected to copper strip 20 X 3 mm as earth lead by means of bolts, nuts, check nuts and washers of steel and other end connected to earthing test point including funnel, 20mm dia GI pipe medium grade for watering pipe and 25mm bore GI pipe, light grade for protection of copper strip, wire mesh, charcoal or coke and common salt in alternate layers all around the earth electrode compacted thickness 15 cm, earthing pit in PCC (1:3:6) type C1, 50 mm thick pre-cast RCC cover slab (1:2:4) type B1 set in CM (1:4), reinforced with 8 mm dia TMT bars @ 10 cm c/c and suitable handle of 10 mm dia MS round bars including earth work in excavation in soft/loose soil, desposal of soil not exc. 50 meter complete and testing on completion all as shown in electrical plate No-3 of MES schedule, part-I complete all as specified and directed. NOTES 1). The unit rate include copper strip from top of earth plate upto 7.5 meter above ground level.
M/S. SUBHAS CONSTRUCTION CO.
M.S. Construction
M/s JK Jangid and Company
Hindusthan Traders and Engineers
KR POWER INFRA INDIA PVT LTD.
EVERLITE ENGINEERING INDUSTRIES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .