Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.4 LAccepted-AOC 29 7 KACHERI ROAD NEAR DISTRICT HOSPITAL PRATAPGARH PRATAPGARH UTTAR PRADESH 230001 | PRATAPGARH | UTTAR PRADESH | 230001 | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹32.6 L+₹31,428.95 (0.97%)Rejected-Finance 60 310A 3 KHERIA MOD JAGNER ROAD AGRA 01 | AGRA | UTTAR PRADESH | 282001 | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹36.5 L+₹4.2 L (13.0%)Rejected-Finance | L-3 | Rejected-Finance Being other than lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
27 Sept 2021, 6:00 pmClosed
GE (AF) TECH AREA AGRA
GE (AF) TECH AREA AGRA
PETTY/ESSENTIAL REPAIRS TO WATER SUPPLY SYSTEM AT MAP ANC AND MAP 4 AREA, SWIMMING POOL UNDER GE(AF) TECH AREA AGRA AT AF STN AGRA
2021_MES_471911_1
8200/1356/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE (AF) TECH AREA AGRA
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) TECH AREA AGRA
₹92,000
Yes
9 Dec 2021
1 Sept 2021
29 Sept 2021
1 Sept 2021
27 Sept 2021
15 Sept 2021
1 Sept 2021 - 7 Sept 2021
Amount
Taking up/down GI/HDPE/PEALPE tubing including fitting from trenches, walls, ceilings for relaying/replacement for the following sizes all as specified and directed :-
(a) 15 mm bore tubing
(b) 20 mm bore tubing
(c) 25 mm bore tubing
(d) 40 mm bore tubing
(e) 50 mm bore tubing
(f) 80mm bore tubing
(g) 100mm bore tubing
Laying only in trenches after cleaning water tubing & connections with steel water/HDPE/PEALPE tubing as retrieved from item No 1 here-in-before after cleaning, washing or removing old screw thread as required & providing new fittings, as required, complete all as specified and directed for the following sizes :-
(a) 15 mm bore tubing
(b) 20 mm bore tubing
(c) 25 mm bore tubing
(d) 40 mm bore tubing
(e) 50 mm bore tubing
(f) 80mm bore tubing
(g) 100mm bore tubing
Laying only, after cleaning water tubing & connections with steel water/HDPE/PEALPE tubing as retrieved from item No 1 here-in-before, fixed to wall, ceiling or laid in floor after cleaning, washing or removing old screw thread as required & providing new fittings, wherever required, complete all as specified and directed for the following sizes :-
(a) 15 mm bore tubing
(b) 20 mm bore tubing
(c) 25 mm bore tubing
(d) 40 mm bore tubing
(e) 50 mm bore tubing
(f) 80mm bore tubing
(g) 100mm bore tubing
Supply, laying, testing in renewal GI tubing medium grade in trenches including required GI fitting complete all as specified and directed for the following bore :-
(a) 15 mm bore tubing
(b) 20 mm bore tubing
(c) 25 mm bore tubing
(d) 40 mm bore tubing
(e) 50 mm bore tubing
(f) 80mm bore tubing
(g) 100mm bore tubing
Supply, fixing, testing in renewal GI tubing medium grade on walls/ ceiling or laid in floor including GI fitting complete all as specified and directed for the following bore :-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
M&L in renewal for drilling & tapping cast iron mains in position for branch connection of 20mm bore GI pipe with MS clamps complete all as specified and directed.
Supply & fixing in renewal gun metal globe gate valve with iron wheel head, screwed both ends ISI mark for the following sizes all as specified & directed :-
(a) 50mm bore
(b) 40 mm bore
(c) 25 mm bore
(d) 20 mm bore
(e) 15 mm bore
S&F in renewal bib tap 15mm bore standard of PTMT any colour screwed for iron pipe and fixed complete all as specified and directed.
M&L in renewal for lead joints including spun yarn & taking out old lead by burning etc for the following bore of CI pipe /fittings complete all as specified and directed :- Note: Quoted rate shall deemed to include necessary excavation and earth work and taking out old lead which shall be reused in making of lead joint.
(a) 300 mm bore
(b) 200 mm bore
(c ) 150 mm bore
(d) 100 mm bore
(e) 80 mm bore
Dismantling, opening head of sluice valve, taking out wedge nut/spindle with nut/wedge for replacement and refixing after replacement of GM wedge nut and stainless steel spindle and refacing/regrinding sheet etc for the following size of sluice valve including nuts, bolts, washer, rubber packing and gland complete all as specified and directed.
(a) 200 mm bore
(b) 150 mm bore
(c) 100 mm bore
(d) 80 mm bore
Supply & fixing in renewal of cast iron body sluice valve ISI marked PN 1.6 and conforming to IS 14846 with stainless steel spindle of following sizes all as specified and directed :-
(a) 200 mm bore
(b ) 150 mm bore
(c) 100 mm bore
(d) 80 mm bore
M&L in renewal for ‘D’ joints complete with collars, rubber ring, nuts & bolts etc for following bore complete all as specified and directed :-
(a) 300 mm bore
(b) 200 mm bore
(c) 150 mm bore
(d) 100 mm bore
(e) 80mm bore
(f) 50 mm bore
Supply & fixing in renewal of cast iron body non return valve ISI marked including complete fixing accessory of following sizes all as specified and directed :-
(a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore
Supply, lowering and testing in renewal 32 mm dia high density polythylene column pipe in bore well, ISI marked, pressure rating 6 kgf/ cm2, with and including jointing material including taking down old U/S HDPE pipe complete all as specified and directed.
Supply laying and testing in renewal PVC insulated and PVC sheathed copper conductor cable 2.5 Sqmm, 3 core flat for 1100 volts AC including connecting with submersible motor to starter panel complete all as specified and directed.
Taking out submersible pumping set of 1.5 / 2.0 HP and lowering after repair with replacement of bushes, sleeves, shaft, PVC impeller and rewinding of motor including testing all as specified and directed.
Supply and fixing in renewal wall mounted cubical type panel board with locking arrangement, suitable for comprising of starter, condenser, volt meter, indicator lamp, Amp meter, MCB/cut out of suitable capacity for 1.5/2 HP single phase submersible pumping set including fixing arrangement complete all as specified and directed.
Supply & fixing in renewal Cast iron pipes with flanged ends, centrifugally cast, class B, in any length laid in trenches/over head reservoir with Nut bolt and all fitting arrangments of following dia complete all as specified and directed . Note - Working height will be upto 21 mtrs. All T&P and risk will be of contractor.
(a) 80 mm dia
(b) 100 mm dia
(c) 150 mm dia
Demolition of PCC/Black bitumin road of any description and in any position not otherwise specially provided for complete all as specified and directed.
M&L PCC (1:2:4) type B2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
M&L PCC (1:2:4) type B2 (using 40mm graded stone aggregate) as in foundation, filling and mass complete all as specified and directed
M&L for Brick work with subclass `B` bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 Complete including demolition of existing old brick work built in cement mortar complete including demolition of existing old brick work built in cement mortar complete all as specified and directed
M&L for rendering 10mm thick in CM 1 : 6 finished even smooth without using extra cement on fair faces of brick work or concrete surface complete all as specified and directed.
M&L for MS sheet cover including angle iron frame with handle of MS round/square bar including painting with two coats of synthetic enamelled paint over one coat of red oxide primer complete for valve pit chamber in FE 410-W grade-E-250 quality A complete all as specified and directed.
M&L for rotational moulded polyethylene water storage tanks tripple layer of following capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
(a) 500 ltrs
(b) 1000 ltrs
Excavation in trenches in soft/loose soil n. exc 1.5 Mtr wide and not exc. 1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick complete all as specified and directed.
Removal of excavated material to a distance not exc 50 Meter and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed.
M&L in renewal for Cutting of cast iron pipe in position for insertion of new tee, coller etc for the following bore all as specified and directed: -
M & L in renewal for flange joints with rubber sheet 3mm thick, including nuts, bolts, washers etc for the following bore all as specified and directed:-
Supply, fixing, jointing & testing in renewal cast iron fittings such as bends (any types radius and angle) tappers, collers, tee , Y junction, plugs, caps and connecting pieces or any other special required at site for the flanged/spigot and socketed pipes upto 150 mm dia complete all as specified and directed.
Supply, fixing, jointing & testing in renewal cast iron fittings such as bends (any types radius and angle) tappers, collers, tee , Y junction, plugs, caps and connecting pieces or any other special required at site for the flanged/spigot and socketed pipes upro 200 mm to 300 mm dia complete all as specified and directed.
Taking up cast iron water mains (including all fittings), with flanged/spigot and socket ends and lead joints including burning out joints and recovering lead of following dia complete all as specified and directed :-
(a) 100 mm dia
(b) 150 mm dia
(c) 200 mm dia
(d) 300 mm dia
Relaying of CI/DI pipe of following dia obtained from item No 33 herein before including jointing complete all as directed :-
(a) 100 mm dia
(b) 150 mm dia
(c) 200 mm dia
(d) 300 mm dia
M&L for DI pipes ISI marked of make as specified with spigot and socket ends suitable for tyton joints, centrifugally cast, class K-9, in any length confirming to IS: 8329(2000) as per latest amendments, laid in trenches with & including making rubber gasket joints (Tyton joint) and testing on completion complete all as specified and directed for the following sizes:-
(a) 100mm bore
(b) 150mm bore
(c) 200mm bore
(d) 300 mm bore
Taking out U/S submersible pump set including motor from bore well of capacity 1.5HP after disconnecting all electrical connections & supply, fixing, lowering, commissioning & testing in replacement including wiring from motor to panel of new submersible pump set of discharge capacity 70 LPM at 57 metre head single phase , 230 volt AC electric driven 2900 RPM of 1.5 HP complete all specified and directed.
S&F in repairs cast iron foot valve, flanged type with flanged, ISI marked, including making flanged joints with & including 3mm thick rubber sheet, nuts & bolts etc of suitable size for following bore complete all as specified and directed.
(a) 80mm bore
(b) 100mm bore
M & L for construction of brick masonry valve pit with sub-class 'B' brick built in cement mortar (1:6), of size (90 x 90 x 90) cm (internal dimension) with one brick walling and150 cm x150 cm x 10 cm base foundation with PCC (1:3:6), type C2 with cement plastering 10 mm thick with cement mortar (1:4) on internal & exposed surfaces, including MS cover of size 01mtr x 01mtr made out from 3 mm thick MS sheet including (40 x 40 x 5) mm angle iron framing on MS cover as well as on top wall of the valve pit & painting of the steel surfaces with two coats of synthetic enamel paint (first quality) over a coat of red oxide primer, including necessary earth work including demolition of the existing old valve pits, complete all as specified and as directed.
M&L for earthing complete with galvansided steel earth plate electrode 600 x 600 x 6.0mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50M below the ground level, connected to GI strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe medium grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS bolts & washers as required and connection from earth test point to earth electrode with same GI strip alongwith protection pipe (upto max distance of 7.5 mtr is included in unit rate) complete all as specified and directed.
M&L for cutting of existing HDPE/ GI pipe of 40/50mm bore for cleaning/ leakage repairing and re-jointing the same in existing position with & including jointing rings and heating process including all necessary excavation & earth work if required and making good the surfaces as per existing complete all as specified and directed.
M&L for cutting of existing HDPE/ GI pipe of 25mm bore for cleaning/ leakage repairing and re-jointing the same in existing position with & including jointing rings and heating process including all necessary excavation & earth work if required and making good the surfaces as per existing complete all as specified and directed.
M&L for cutting of existing polyethylene aluminium polyethylene (PE-AL-PE) pressure/ GI pipe of 15/20 mm dia for cleaning/ leakage repairing and re-jointing the same in existing position with & including jointing rings and heating process including all necessary excavation & earth work if required and making good the surfaces as per existing complete all as specified and directed.
S&F in repairs HDPE fittings i.e reducer/ tee/ ring suitable for HDPE/ polyethylene aluminium polyethylene (PE-AL-PE) pressure pipe for stoppage of leakage at different locations/ areas including all necessary excavation & earth work if required and making good the surfaces as per existing complete all as specified and directed for the following sizes:-
(a) HDPE Tee 50x 50 X 16-20 mm bore
(b) HDPE tee of 16-20x16-20x12-16mm dia
(c ) HDPE tee of 20-25x20-25x16-20mm dia
(d) Jointing/ copper rings of 20/25mm dia
Taking out submersible pump set including motor of capacity up to 15.0 HP with column pipe from bore well after disconnecting all electrical connections and lowering the same after necessary repair/ replacement of wornout/ damaged parts of pumps/ motors/ pipe joints including transportation to work shop and back after repair and making all electrical connections and testing on completion complete all specified and directed. Note:- Repair/ replacement of wornout/ damaged parts of pumps/ motors/ pipe joints shall be measured and separaterly under respective items of BOQ
Dismantling/opening of submersible pump of capacity 10.0/ 15.0 HP for complete servicing with materials including cleaning & reassembling the same and testing on completion all as specified and directed with replacement of the following items/parts:-
(a) Replacement of GM bushes & sleeves of pump of existing size & make complete.
(b) Replacement of SS coupling with key of existing size & make complete.
Dismantling/opening of submersible motor of capacity 10.0/15.0HP for complete servicing with materials including cleaning & reassembling the same and testing on completion complete with replacement of the following items/parts all as specified and directed:-
(a) Rewinding with & including PVC insulated copper winding wire of same gauge & quantity and sealing the winding by using sealing compound including cutting and taking out existing burnt winding complete.
(b) Replacement of thrust plate and bushes of existing size & make complete.
Taking out monoblock pump set including motor of capacity 10/ 12.5 HP from foundation after disconnecting all electrical connections and refixing the same on foundation after necessary repair/ replacement of wornout/ damaged parts of pumps/ motors including making all electrical connections and testing on completion complete all specified and directed. Note:- Repair/ replacement of wornout/ damaged parts of pumps/ motors shall be measured and paid separaterly under respective items of BOQ.
Dismantling/opening of monoblock pump including induction motor of capacity 10.0/ 12.5HP for complete servicing with materials including cleaning & reassembling the same and testing on completion complete with replacement of the following items/parts all as specified and directed:-
(a) M&L for rewinding of motor with & including super enamelled copper winding wire of existing gauge & No of turns, re-insulating, two coats varnishing & heating including cutting and taking out existing burnt winding complete.
(b) Replacement of bearings of motor & pump of existing size & make complete.
(c) Replacement of GM bushes of pump of existing size & make complete.
(d) Rematling of shafts of pump complete.
Cleaning of pressure filter plant including taking out of all material from filter plant and cleaning with anti bacterial solution including painting out side with replacement of new rubber gasket complete all as specified and directed.
Supply and filling filter media suitable for existing pressure filter at swimming pool as per existing qty of charcole and gravels of required sizes all as specified and directed
Dewatering of the swimming pool, cleaning the ceramic tiles with suitable chemicals & acid and rubbing the tiles with soft nylon brush to remove all the stains deposited on the tiles for complete glow to the entire satisfaction of Engineer-in-Charge- all as specified and directed.
Dewatering of the springs (fountain) as directed, cleaning the ceramic tiles with suitable chemicals & acid and rubbing the tiles with soft nylon brush to remove all the stains deposited on the tiles for complete glow to the entire satisfaction of Engineer-in-Charge all as specified and directed.
Supply and laying or fixing or passing in well/ borewell in replacement, 1100 volts grade heavy duty, PVC insulated and PVC sheathed mutistranded copper conductor submersible cable of size 6.0sqmm 3 core flat including connection to submersible motor/ starter panel with & including necessary jointing materials if required and testing on completion complete all as specified and directed.
Supply and laying or fixing or passing in well/ borewell in replacement, 1100 volts grade heavy duty, PVC insulated and PVC sheathed mutistranded copper conductor submersible cable of size 10.0sqmm 3 core flat including connection to submersible motor/ starter panel with & including necessary jointing materials if required and testing on completion complete all as specified and directed.
Cutting of sapling with their roots, vegetation of any type & height etc, girth not exceeding 30 CM up to 5 Mtr around the periphery of the pump house and surrounding area of OHT/ UG sumps and making the area neat and clean by removing/ throwing the rubbish to a distance not exc. 50 mtr complete all as specified and directed.
Carryout day to day rectification of water supply complaint such as repair, reconnection and replacement of unserviceable items such as elbow, tee socket, union, clamps etc including excavation & earthwork to detect the leakage / faults returning / filling excavated material to match the surface / around level as per existing level etcall as specified and directed
Note: (a) 01 x Pipe fitter and 02 x helper will be detailed by the contractor for attending above complaints on daily basis. Cost of which shall be deemed to be included in quoted rates. (b) Replacement of major items shall be measured and paid under relevant items of schedule and cost of all other fittings/ material required to complete the job shall deemed to be included in quoted rate. (c) Pipe fitter and helper so detailed by the contractor will report to MES complaint cell at 0845 hrs morning to receive complaint slip from department and complaints shall be rectified within 08 Hours. If contractor fails to detail above tradesmen a panel recovery@ Rs. 500.00 per day shall be made to contractor and shall be recovered from RAR/Final bill. (d) Repairing upto 06 Complaints at different water supply system without any other material will be considered as one job.
rohan traders
M/s S.M. Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .