Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC L1 QUOTED | |
| 2 | L2₹17.0 L+₹1.1 L (7.08%)Rejected-AOC KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L2 | Rejected-AOC L2 QUOTED | |
| 3 | L3₹17.4 L+₹1.6 L (9.86%)Rejected-AOC | L3 | Rejected-AOC L3 QUOTED | |
| 4 | L4₹18.9 L+₹3.0 L (19.0%)Rejected-AOC | L4 | Rejected-AOC L4 QUOTED |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
4 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Srinagar
GE (AF) Srinagar, AF STN SRINAGAR - 190007
REPAIR TO JOINT PAVEMENT PU REPAIR JOINT FILLING, DRAIN CLEANING, EARTH FILLING, SHOULDERS CLEARANCE AT AIR FORCE STATION SRINAGAR
2020_MES_355767_2
GE (AF)-10/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Srinagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF Srinagar
₹40,000
Yes
7 Sept 2020
15 Jul 2020
6 Aug 2020
15 Jul 2020
4 Aug 2020
22 Jul 2020
15 Jul 2020 - 18 Jul 2020
60 days
Amount
M&L for grass cutting by Jungle Jim on vehicle ridden machine both sides of Runway/PTT as on requirement basis and timing as feasible by the user complete including taking out all necessary grass shrubs saplings wild bushes and any type of vegetation and removing away from MOD land complete all as specified and as directed by Engineer-in-Charge.
M & L for grass cutting by manually or mechanically (Bush Cutter) on the both side of runway/PTT as per requirement basis and timing as feasible by the users, complete including taking out all necessary grass shrubs saplings wild bushes and any type of vegetation and removing out of MOD Land complete all as specified and as directed by Engineer-in-Charge.
M & L for preparation of old concrete/ bituminous surfaces by brushing and applying one coat of paint with water based paint in pattern of lines/arrows/letters etc on road or pavements exc 10cm width or girth, complete all as specified and directed by Engineer‐in‐Charge.
M&L for preparation of surfaces and applying one coats of synthetic enamel paint on wooden/steel/ concrete surfaces complete all as specified and as directed by Engineer-in‐Charge.
Cleaning of storm water drain by excavating mud/ soil manually and removing the exacavated material to a distance n.exc 50 mtr the inner girth of drain 0.5 mtr to 1.5 mtr and depth of excavated material n. exc 20 cm complete all as specified and directed by Engineer-in-charge.
Cleaning of storm water drain by excavating mud/soil manually and removing the exacavated material to a distance n.exc 50 mtr the inner girth of drain 0.5 mtr to 1.5 mtr depth exc 20 cm complete all as specified and directed by Engineer-in-charge.
M & L for ploughing the old sand filling in soft ground arrester, complete all as specified and as directed by Engineer-in-Charge.
M & L for Repair to patches exc area 300 Sqcm and n exc 500Sqcm, depth n.exc 80mm including sweeping free from dust and mud or water with wire or jute brush scoring sunken surfaces in runway pavement , cutting arround edge to at least full depth of carpet layer making proper rectangular or square shape patch and making good by applying tack coat with bituminous primer (catonic emulsion RS) premix asphaltic dense concrete 50 to 80mm (Consolidated thickness) with 6% binder content by weight of total mix with coarse sand and aggregate 6mm down grade using polymeric modified bitumen rollled and compacted to required camber and gradient with hand roller complete and claening the surface by brooming and making FOD(Foreign object debris) free surface to runway, Complete all as specified and directed by engineer in charge.
Cutting and racking out old sealing compound from the old joints cleaning with kerosene oil, drying with blow lamp, cleaning the joints portion throughly to ensure dust free using compressed air, trimmeing of edges of joints with diamand cutter and cleaning the joints atleast 40mm wherever required, remove all dust/ debris out of runway and filling the existing joints with polyurethene based sealant after applying a coat of primer to vertical surfaces of concrete which are in contact with the compound and finishing the joint properly leaving 3mm gap from top surface of concrete over and including backup rod complete all as specified and directed by Engineer-in-Charge for the following joint size:- Note: Any damage to the existing backup rod shall be made good by the contractor without any extra cost. Make: Rallithane 872 of Pavetech/Bostic/New Guvinder Industries.
(a) Joints of size 1cm to 1.5cm wide and 1.5 to 3.0 cm deep
(b) Joints of size 2cm to 2.5cm wide and 1.5 to 3.0 cm deep
M & L repair to broken spalled edges of joints, pot holes etc of existing concrete slab by cuting 'U' grooves with mechanical cutter, cleaning the joint portion throughly to ensure dust free using compresser air removing all dust/debris out of runway applying compound of hardener Aradur-140 and Araldite GY-257 primer in the ration of 1:2 by weight and filling the joint with epoxy mixture of Aradur-140, Araldite GY-257 and quartz sand & silcon flour mix No 10 in the ratio of 1:2:15 by weight and finishing the top surface smooth all as per manufacturers instructions and complete all as specified and directed by Engineer-in-Charge for the following joint size:- Make: M/s Huntsman Advanced Materials (India) Pvt. Ltd or equivalent as approved by Garrison Engineer
(a) Joints of size 1 to 2cm wide and depth n.exc 2.0 cm
(b) Joints of size 1 to 2cm wide and depth exc 2 and n exc 4.0 cm
M&L for preparation of old decorated or unplastered surfaces of walls including cornices, pilasters and applying Two coat of white wash complete all as specified and directed by Engineer-in-Charge
Raking out joints/ pointing to random rubble stone masonary uncoursed or brought up to courses built in cement mortar, complete all as specified and directed by Engineer-in-Charge.
M & L for Flush pointing to random rubble stone masonry uncoursed or brought up to courses in cement mortar 1:3 complete all as specified and directed by Engineer-in-Charge
Demolition of cement oncrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L Cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating to finished even and smooth complete all as specified and as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc, complete all as specified and directed by Engineer-in-Charge.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 but except stone, complete all as specified and directed by Engineer-in-Charge
Demolition of concrete of any description and in any position not other wise specifically provided for and demolished material thrown out of runway premises complete all as specified and directed by Engineer-in-Charge
M&L for polythene film 150micron thickness for separation layer under concrete complete all as specified and directed by Engineer-in-Charge
M&L sand cushion layer under polythene film complete all as specified and directed by Engineer-in-Charge
M&L Cement concrete work in pavement / hard standing of flexural strength 40kg/Sqcm in field using minimum 400Kg of cement per cum for thickness of concrete 25cm or less complete all as specified and directed by Engineer-in-Charge
M&L forming 25mm wide expansion joints through the full thickness 250mm of the slab filled with 25mm thick synthetic compressive filler board HD-100 and cleaning 50mm deep left over to top cavity and top 10mm primed with N-49 primer and filled with polyurethane based sealant over 30mm dia polyethylane back up rod complete all as specified and directed by the Engineer-in-charge.
Note for items No.3,4,8,9 & 10:- The work is to be carried out in operational runway where air traffic plays regularly.Therefore the site shall be made available as per the availability and as decided by the airforce authority. Contractor shall not have any claim whatsoever on this account at any belated stage.Contractor shall arrange man and material accordingly and shall quote his rates accordingly.
M/S RATHER CONSTRUCTION CO
M/S ABDUL REHMAN WANI
M/s MAQBOOL BHAT AND SONS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .