Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC | ₹2.1 Cr | L1 | Accepted-AOC order issue to agency |
| 2 | L2Rejected-Finance 2177 SECTOR 21 C CHANDIGARH | - | L2 | Rejected-Finance Lowest 2 |
| 3 | L3Rejected-Finance | - | L3 | Rejected-Finance Lowest 2 |
Tender Value
₹2.3 Cr
EMD Value
₹4.6 L
Closing Date
11 Jun 2018, 5:00 pmClosed
Incharge Civil
SCO 153 155 Sector 34A Chandigarh
Interior works including Additions Alternations in the existing buildings for Retail Sweets Sales Point cum Restaurant and Procurement Building at Verka Mohali Dairy
2018_Coop_15704_1
PSF/XEN/4607
Open Tender
Civil Works - Buildings
Item Rate
240 days
Verka Corporate Office
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
TIA
₹4.6 L
2 Nov 2020
8 May 2018
12 Jun 2018
8 May 2018
11 Jun 2018
8 May 2018
Amount
SUB HEAD-1 DISMANTLING
Dismantling/removing of existing Alluminium/ M.S. glazing/window/ ventilator (fixed/ openable) alongwith M.S. hold fasts embedded in cement concrete and hoop iron bars from the wall/ between the columns etc. including removing of glass panes and returning to the stores as directed including finishing the broken surface to match with the existing as per site requirement complete in all respects as directed by the E-in-C.
Dismantling/removing existing Alluinium/ Steel/wooden Doors/windows/cub board alongwith door clousers and with chowkhats by making recesses in walls when the wall is not to be dismantled or with welding set and returning to the stores as directed including finishing the broken surface to match with the existing as per site requirement complete in all respects as directed by the E-in-C.
Dismantling of existing Brick work/ tile masonry in cement mortar, as per actual site conditions/ requirements, finishing the broken surface to match with the surrounding, removing the debris etc. from site of work to dumping ground/yard - approved by the M.C., Mohali , Including cutting the reinforcement if any and cleaning & stacking of dismantled bricks and bats for re-use in new work, complete in all respects as directed by the E-in-C. NOTE:- I.Recovery of dismantled bricks to be reused will be made @50% of quantity of dismantled brick work as per provisions of CSR-2010 and premium list, applicable at the time of tender. II. Recovery of dismantled brick bats to be reused, will be made @ of 50% quantity of dismantled brickwork as per provisions of CSR-2010 and ceiling premium, applicable at the time of tender.
Dismantling of reinforced cement concrete for all types of R.C.C. work including cutting of reinforcement and finishing the broken surface to match with the surrounding and removing the debris from site of work to dumping ground/yard - approved by the M.C., Mohali ,as directed by the E-in-C.
Dismantling of existing terrazo flooring and skiriting of all thickness excluding base coarse, complete in all respects, including removing the debris from site of work .
Dismantling of vetrified /glazed tiles (to be carefully removed) flooring, skirting and dado to at any height including cleaning of surface and disposal of debries from site of work to dumping ground - approved by the M.C., Mohali as directed by the E-in-C.
Dismantling of existing Tile Terracing from the roof, including mud phuska and mud plaster of all thicknesses, as per existing/actual site conditions/ requirements including cleaning of RCC slab surface with wire brushes etc. and removing the debris etc. within site/campus, cleaning and stacking of dismantled brick tiles and bats to be deposited to the stores of Milk Plant, Mohali complete in all respects as directed by the E-in-C. NOTE:- I.Recovery of dismantled brick tiles to be reused will be made @75% of quantity of dismantled tile terracing as per rates mentioned in the CSR-2010 + premium list, applicable at the time of tender. II.Recovery of dismantled tile bats to be reused, will be made @ 25% of quantity of dismantled tile terracing as per rates mentioned in the CSR-2010 + premium list, applicable at the time of tender.
Dismantling of existing HCI soil pipes, specials including dismantling of lead joints and returning the same to the stores of Milk Plant, Phase-6, Mohali, as directed including finishing the broken surface to match with the existing as per site requirement complete in all respects as directed by the E-in-C.
a) 150mm i/d HCI Pipe
b) 100mm i/d HCI Pipe
c) 75 mm i/d HCI Pipe
Dismantling, disjointing, removal of G.I.pipe lines, specials, valves and fittings including returning the same to the stores of Milk Plant, Phase-6, Mohali, as directed including finishing the broken surface to match with the existing as per site requirement complete in all respects as directed by the E-in-C.
a) 15mm internal diametre pipe line.
b) 20mm internal diametre pipe line
c) 25mm internal diametre pipe line
d) 32mm internal diametre pipe line
e) 40 mm internal diametre pipe line
Dismantling/removing (carefully) of existing chinaware sanitory fittings, fixtures and specials etc. as directed including finishing the broken surface to match with the existing as per site requirement complete in all respects as directed by the E-in-C.
a) European/Indian type water closet Suit including flushing cistern and fitting etc. complete job
b) Urinal pots alongwith autometic flushing cistern and fitting etc. complete job
c) Lavatory suites (wash hand basin) and fittings complete job.
Dismantling/removing (carefully) of existing stainless steel sinks (of any size) alongwith fittings, fixtures and specials etc. , as directed including finishing the broken surface to match with the existing as per site requirement complete in all respects as directed by the E-in-C.
Dismantling/scraping of old cement plaster of all thicknesses and any ratio (at any height) including cleaning of surface for re plastering, disposal of debries within campus complete in all respect as directed by the E-in-C.
Dismantling of lean concrete of any ratio and removing the debris within campus as directed by the E-in-C.
Dismantling of existing Inspection chamber of size as per actual site requirements including RCC top slab, CI cover with frame and returning the servicable material to the stores of Milk Plant, Mohali, complete job as directed by the E-in-C
Dismantling of existing Gully Trap of size as per actual site requirements including RCC top slab, CI cover with frame and returning the serviceable material to the stores of Milk Plant, Mohali, complete job as directed by the E-in-C
Dismantling of existing Katni/Marble flooring and skirting/dado of all thickness excluding base coarse, complete in all respects, including removing and disposal of the debris within campus as directed by the E-in-C.
Dismantling/removing of existing false ceiling consisting of Bison panels, G.I. cradlings and electrical fittings/fixtures and returning the same to the stores with in campus as directed including finishing the broken surface to match with the existing as per site requirement complete in all respects as directed by the E-in-C.
SUB HEAD-2 EARTH WORK
Earth work in excavation for all type of foundations, footings, trenches, lift well etc. in all kinds of soil where pick-jumper work is not involved and not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent refilling around masonary/concrete etc. in 15cms layers with compaction/ consolidation, including disposal of all surplus soil as directed, within campus / site.
Earth filling under floors/in plinth with surplus soil excavated from foundations (as per above) and taken only from outside the building plinth, in 15cms layers including ramming, watering and consolidating as directed by the Engineer-in-Charge.
Earth filling under floors with approved earth brought from outside (any lead) and filling in 15cms layers including carriage, loading & unloading, ramming, watering and consolidating, complete in all respects as directed by the Engineer-in-Charge.
Providing and filling in plinth and under floors approved local river sand including carriage loading, unloading, spreading, watering, ramming, consolidating, etc. complete as directed by the Engineer-in-Charge.
Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS-6313-2001 (Part-2) & using Chemical containing chloropyrifos systemic insecticide diluted to manufacturer’s specifications i.e. 1 Ltr. of choropyrifos and 19 ltr. water:- (i)In foundation pits, by treating the bottom & sides up to height of 300mm by uniformly spraying solution @ 5 litre per sqm. (ii)In the refill earth on both sides of all built up walls @ 7.5 litre / Running meter (width -300mm, depth -450mm).(iii)Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 litre solution per sqm.
SUB HEAD-3 CENTERING AND SHUTTERING
Providing and fixing steel shuttering for faces of all type of concrete foundations, footings, strips, pedestals, foundation beam, plinth beams (vertical, or battering) and columns etc. Complete in all respects as directed by E-in-C.
a) In foundation and plinth upto ground level
Providing and fixing steel shuttering and centering for RCC columns (square or rectangular). Complete in all respects as directed by E-in-C.
a) upto 4 meters ht. above plinth level.
Providing and fixing steel shuttering and centering for sides and soffits of beam, beams launchings girders bressumers, lintels etc. Complete in all respects as directed by E-in-C.
a) upto 4 meters ht. above plinth level.
Providing and fixing steel shuttering and centering for flat surfaces such as suspended floors, roof, landings, chajjas, shelves. Complete in all respects as directed by E-in-C.
a) upto 4 meters ht. above plinth level.
Providing and fixing steel shuttering and centering for carbles, parapet, facias and other similar items including edges. Complete in all respects as directed by E-in-C.
a) upto 4 meters ht. above plinth level.
Providing and fixing steel shuttering and centering for stair cases with sloping with soffits etc. Complete in all respects as directed by E-in-C.
a) upto 4 meters ht. above plinth level.
Extra rate for shuttering where any single storey height exceeds 4 metres in height for every additional height of 2 metres or part thereof
SUB HEAD-4 CONCRETE WORK
Providing and laying plain cement concrete 1:5:10 using concrete mixture volumetric type with stone aggregate (1 cement: 5 coarse sand: 10 stone aggregate 40mm gauge) for all types of foundations, footings, below rafts, extension columns, plinth beams/under floor etc. including spreading, laying, ramming and consolidating as per requirements and curing etc. but excluding centering and shuttering, complete in all respects as directed by E-in-C.
Providing and applying HILTIE arrangement for making necessary holes to inserting steel reinforcement bars in the existing RCC columns, slab etc. and upto required depth for after using “HILTIE” chemical HY-150. Complete as per structrual drawings and to the entire satisfaction of the E-in-C.
a) For 20mm dia steel reinforcement bars.
b) For 16mm dia steel reinforcement bars.
c) For 12mm dia steel reinforcement bars.
Providing & laying Reinforced cement concrete M-25 mechanically mixed using batch type concrete mixture as per IS 1791 and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering, for all types of RCC works i.e. column, footings, strips, pedestals, tie beams & plinth beams etc. as per structural drawings/ design including laying, spreading, ramming, watering, consolidating &curing etc., Complete in all respects as directed by the E-in-C.In foundation and upto plinth level
In foundation and upto plinth level
Providing & laying Reinforced cement concrete M-25 mechanically mixed using batch type concrete mixture as per IS 1791 and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering, for all types of RCC works i.e. column, beams, slabs and fascias etc. as per structural drawings/ design including laying, spreading, ramming, watering, consolidating & curing etc., Complete in all respects as directed by the E-in-C. In super structure
a)Upto 4 m ht. above plinth level.
Providing and fixing/placing in position Ribbed/Tor/T.M.T. Steel Bars, for R.C.C. works, where not including in the complete rate of R.C.C. included bending, binding and placing in position as per structural design/ drawing including cost of binding wire. Complete in all respects as directed by the E-in-C.
Providing and laying 40mm thick damp proof course with machine mixed PCC 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm down) including 2 coats of bitumen (25/85 grade for building works) penetration @ 1.65 kg/M2, laid hot and sanded, bitumen to be applied uniformly and after proper curing of concrete, complete in all respects as directed by the E-in-C.
Providing and laying 20mm thick cement plaster in damp proof course 1:3 including 2 coats of bitumen (25/85 grade for building works) penetration @ 1.65 kg/M2, laid hot and sanded, bitumen to be applied uniformly and after proper curing of concrete, complete in all respects as directed by the E-in-C.
Providing and laying PCC 1:2:4 screed/leveling course under floors as per site requirements Compete in all respects to the entire satisfaction of E-in-Charge.
Supplying, fabricated, cutting, welding and fixing in position structural steel work consisting of ISMB, ISMC and plates in coloumns and beams etc. as per structural drawings and details etc. including painting with one coat of red oxide and two coats of enamel paint of approved quality and shade. complete in all respects.
SUB HEAD-5 BRICK WORK
Providing & constructing Ist Class burnt brick work laid in cement sand mortar 1:6 (1 cement: 6 coarse sand) including scaffolding, watering, curing etc. complete in all respects, as directed by the E-in-C.
a) In foundation and upto plinth level
b) In super structure upto 4 meters ht. above plinth level.
Extra rate for brick work done in additional storey upto 4 meters above the top of structural roof of lower storey as directed by the E-in-C.
Providing & constructing Ist Class burnt brick work - 115mm thick wall without reinforcement course laid in 1:5 cement sand mortar including watering, curing etc. complete in all respects, as directed by the E-in-C.
a) In foundation and plinth.
b) In super Sturucture upto 4 m above plinth level
Providing & constructing Ist Class burnt brick work - 115mm thick wall with evrey fourth course with hoop iron laid in 1:4 cement sand mortar including scaffolding, watering, curing etc. complete in all respects, as directed by the E-in-C.
a) In super structure upto 4 meters ht. above plinth level.
Extra rate for 115 mm thick brick wall for additional storey upto 4 meters above the top of structural roof of lower storey as directed by the E-in-C.
SUB HEAD - 6 ROOFING
Providing and fixing/embedding PVC rain water pipe 110mm o/d of 6kg. / Sqcm. make DIPLAST/FINOLEX/SUPREME including jointing with solution and providing and fixing necessary specials etc. Complete in all respects to the entire satisfaction of E-in-C.
Providing and laying Terracing to proper slope consisting of brick tiles 22.86cm x 11.43cm x 3.83cm laid over 25mm mud plaster, 75mm mud filling on another layer of 25mm mud plaster including two coats of bitumen grade 85/25 laid hot at 1.65kg/M2 on top of RCC slab, including grouting with cement sand mortar 1:4 (1 cement:4 course sand) and top surface to be left clean after wire brushing etc. Complete in all respects as directed by the E-in-C.
Extra for providing and applying flush cement pointing 1:2 (1cement: 2 sand) to tile terracing. Including curing etc. Complete in all respects as directed by the E-in-C.
Providing and laying cement concrete 1:2:4 gola 10cm. X10cm. concave quadrant along junction of roofs with parapet wall, finished smooth where specially specified, complete in all respects as directed by the E-in-C.
Providing and constructing Top khurra 0.6M x 0.6M for Rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16, complete in all respects as directed by the E-in-C.
Providing and fixing C.I. grating 100mm dia for rain water pipe. Complete in all respects as directed by the E-in-C.
Providing and constructing Bottom khurra on ground 1.2M x 0.6M consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3 complete in all respects as directed by the E-in-C.
Providing and laying 2’-6’’ wide plinth protection consisting of 2’-3’’ wide brick on edge laid in cement sand mortar 1:4 on 75mm thick cement concrete 1:8:16 and 100mm thick sand filling and cement pointing 1:2 on top including excavation re-filling and disposal of surplus earth within campus.
SUB HEAD-7 FLOORING AND DADOS
Providing and laying vitrified floor tiles 600x600mm size premium quality, manufactured using double charge Technology, with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand ) for new flooring laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per sqm of tile area in average 3mm thickness over existing base, including grouting the joints (Tiles to be laid with 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout) with Cement base grout and matching pigments etc., complete in all respect as directed by the E-in-C. ( Make Johnson / Kajaria/ AGL to be got approved before arranging )
Providing and laying vitrified floor tiles 600x600mm size premium quality, manufactured using double charge technology with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on existing new flooring laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per sqm of tile area in average 3mm thickness over existing base, including grouting the joints (Tiles to be laid with 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout) with Cement base grout and matching pigments etc., complete in all respect as directed by the E-in-C. ( Make Johnson / Kajaria/ AGL to be got approved before arranging )
--do-- for skirting and dado etc. (size as per site requirements)
Providing & laying of Vitrified Tile flooring (1200mmx800mm) (spec. indiacted in the drawings) of approved make & shade with 4mm grooves over necessary leveling of screed with 1:4 cement mortar (20mm thick)with proper slope wherever required including pointing of the joints with LATICRETE® SP100 grout and matching pigments, curing etc. complete in all respects.
Do- but for skirting/dado etc.
Providing and laying Rectified Porcelain Bathroom wall & floor tiles, size 600mmx1200mm (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 (Make Kajaria/ Johnson/Orient or equivalent approved make) in all colours laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Fine sand) for new flooring/dado or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete in all respects add directed by the E-in-C.
Provding and laying machine cut Granite stone 19mm thick of approved shade and required sizes in flooring, counters skirting, treads and risers of steps, dado walls and pillars etc. laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing, nosing in steps etc. including labour for fixing dowel pins and cramps. Compete in all respects to the entire satisfaction of E-in-Charge.
Providing and laying Kota stone tile flooring 20mm to 30 mm thick (to be got approved before fixing) over 12.5mm thick base of cement mortar 1:3 (1 cement, 3 Sand) laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing, complete in all respects as directed by the E-in-C.
Providing and laying Kota stone tiles 20mm thick (to be got approved before fixing) in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing, complete in all respects as directed by the E-in-C.
Providing and fixing Ist quality ceramic glazed wall tiles ( 300mmx300mm) conforming to IS : 15622 (thickness to be specified by the manufacture ) of Johnson make orange colour/dark colour as approved by Engineer‐in‐Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete in all respects as directed by the E-in-C.
Providing and fixing wall tiles (600x300mm) (spec. indiacted in the drawings) conforming to IS : 15622 (thickness to be specified by the manufacture ) of Nitco make- Acrowhite as approved by the Engineer‐in‐Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete in all respects as directed by the E-in-C.
Providing and fixing Travertine finish wall tiles (1200x600mm) spection indiacted in the drawings .The tiles to have a layer of travertine stone in 2.5mm thickness with non filled holes as in natural stone. laid as approved by Engineer‐in‐Charge in skirting, dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.(Basic rate of tile=230/‐per sft)
Providing and laying 60 mm thick cement concrete interlocking paver block of M-40 grade machine made rubber moulded smooth finish by strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design/shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick complete in all respects as per specifications and to the entire satisfaction of E-In-C.
Providing and fixing UNI-Brick tiles smooth size 230x40mm, 12mm thick (Red Colour) of Unistone or equivalent, clading on walls, (design/make to got approved before arranging) in specified pattern laid in 12.5 mm thick cement sand mortar 1:3(1 cement and 3 sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone tiles , including rubbing and polishing wherever required complete in all respect as directed by the E-in-E
SUB HEAD-8 PLASTERING
Providing and applying cement plaster in cement sand mortar 1:5 (1cement: 2.5 fine sand: 2.5 coarse sand) to the walls, columns etc. including providing groove, drip course, scaffolding, finishing, curing etc. Complete in all respects for all heights as directed by the E-in-C.
a)12.5mm thick for all heights.
b) 20mm thick for all heights.
Providing and applying cement plaster on under side of ceiling 10mmm thick in cement sand mortar 1:4 (1cement: 2 fine sand: 2 coarse sand) including scaffolding, finishing, curing etc. Complete in all respects for all heights as directed by the E-in-C.
SUB HEAD-9 GLAZING
Providing and fixing aluminium work colour coated and approved shade, for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :
a) For fixed portion and chaukhats
b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and necessary Alumn. fittings wherever required including the cost of PVC Plug / neoprene gasket etc. complete in all respects as directed by the E-in-C.
Extra for providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. Complete in all respects as directed by the E-in-C.
Extra for providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading is included in the basic item)
a ) Plain/float glass pane of 4 mm thickness.
b ) Plain/float glass pane of 5 mm thickness.
c) Plain glass 8 mm thickness
SUB HEAD-10 INTERIOR WORKS
Providing and fixing of underdecking with thermocol sheets of 50mm thick on roof of Forth floor, before doing the celling work compelte as per drawings, specifications and to the entire satisfications of Architech and E-in-C .
Providing & applying Plaster of Paris (gypsum anhydrous) suspended false ceiling up to any height above floor level, including fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive). Consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts. Other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size. The other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre. This shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval and reinforced with rabbit wire mesh of 100mmx16mm gauge fixed to it. complete in al respect.
Providing and fixing open cell ceiling of Armstrong or equivalent approved make of.016" thick metal of panel size 24"x24"x1.5" blade height and 9/16" blade width and interior cell of size 4"x4" in powder coated surface finish of approved color as directed by E in C. complete in all respect . (Basic Rate of 2x2 Panel upto Rs.340/sqft) .
Providing and fixing of false ceilings at all heights of Gypsum board 12 mm thick as per the standard norms laid by India Gypsum Ltd., which includes providing and fixing G.I. per Perimeter channel of size 27 mm & 0.5 mm thick having one glace of 20mm and another flange of 30mm alongwith perimeter of the ceiling, screw and rawl plugs. Then suspended G.I. intermediate channels of size 45 mm x 9mm thick with two gauges of 1.5mm each from the soffit at 1200mm center with still G.I. hangers of which 25mm x 5mm thick fixed to soffit with G.I. cleat and steel expansion fasteners ceiling section of 5mm thickness having knurled wedge of 51.5mm channel with the help of connecting to clips and in direction perpendicular to the intermediate channel at 45mm centre , 12.5mm taped adge Gypsum board to be screw fixed to ceiling section with 25mm drywell screw at 230mm centers. Screw fixing to be done mechanically. The taped and the square edges of the board are to be jointed and finished to flush finish with requisite jointing compound, paper tapes, finisher and primer, suitable for Gypsum plaster boards . Cutouts have to be made for light Fittings, Ac grills diffusers etc. with the frame of perimeter channels as per designs. The rate shall include making good the damages with cement mortar. Complete as per drawings, specifications and to the entire satisfaction of Architech and E-in-C.
P/F ply wooden ceiling with 11-12mm thick Commercial ply/MDF mounted on GI frame with screws . which includes providing and fixing G.I. per Perimeter channel of size 27 mm & 0.5 mm thick having one glace of 20mm and another flange of 30mm alongwith perimeter of the ceiling, screw and rawl plugs. Then suspended G.I. intermediate channels of size 45 mm x 9mm thick with two gauges of 1.5mm each from the soffit at 1200mm center with still G.I. hangers of which 25mm x 5mm thick fixed to soffit with G.I. cleat and steel expansion fasteners ceiling section of 5mm thickness having knurled wedge of 51.5mm channel with the help of connecting to clips and in direction perpendicular to the intermediate channel at 45mm centre , 12mm thick MDF to be screw fixed to ceiling section with 25mm drywell screw at 230mm centers. Screw fixing to be done mechanically.Ceiling to be further finished with 1mm thick laminate of approved make and colour.fixed with adhesive. complete in all respect .
Providing and fixing of false ceiling at all heights of 600mmx600mmx15mm ARMSTRONG Mineral Fibre ceiling tiles of type DUNE RH-99 laid in grid system. The frame work comprise of made of Gl, 120 GSM coating with minimum 0.3mm thickness main runner spaced at 1200mm centre to centre securely fixed to the structural soffit by approved hangers at 1200mm maximum centres. Hangersa (Gl wire of 4mm dia) to be fixed by approved roof plug, level adjusters and screw etc. The last hanger at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees (with double stiching) to be interlocked between main runners at 600mm centres to form 1200x600mm modules. Cut across tees longer than 600mm to be supported independently. 600x600mm modules to be formed ay fitting 600mm long flush fitting cross tees centrally between the 1200mm cross tees. Perimeter trim to be Armstrong wall angle secured to walls at 450mm maximum centres complete in all respects as per specifications and to the entire satisfaction of E-In-C.
Providing and fixing wall panelling upto ceiling height with 40mmx40mm kail wood frame at 2'-o" c/c in both directions, finished with 4mm commercial ply & 1.0mm laminate in two or more colour. Panelling to have 50x35mm cedar wood moulding on top edge. Panelling finished in melamine polish complete with 100mm x 12mm skirting. Complete as per drawings, specifications and to the entire satisfaction of Architech and E-in-C. .
Providing and fixing full height (frameless) glass patch fitting partitions from floor level to false ceiling level with 12mm thick toughened glass and with DORMA fittings. Complete as per drawings, specifications and to the entire satisfaction of Architech and E-in-C. .
Providing and fixing frameless glass doors (push and Pull type) with 12mm thick toughened glass with fittings and floor spring of DORMA make including cost of Stainless Steel (SS) handles 600mm long and with locking system/arrengment etc. Complete as per drawings, specifications and to the entire satisfaction of Architech and E-in-C. .
Providing and fixing 3M glass film of Birla or equalant approved make and shadeas per design on glazed partitions and toughened glass. Complete as per drawings , specifications and to the entire satisfaction of Architect and E-in- C.
Providing and fixing partitions from floor level to ceiling level and low height with frame work of kail wood of size 50 x 50mm at spacing 600mm c/c with 9mm thick commercial plywood/MDF including grooves as per design, finished with 1mm thick laminate on both sides. Partitions to have 100mm x 12mm thick wooden skirting, the partition to have glass wool filled for sound insulation including coating of anti termite paint, partition to have 50mm x 35 mm cedarwood moulding on top edge , finished in melamine polish . Complete as per drawings , specifications and to the entire satisfaction of Architect and E-in- C.
Providing and fixing 62mm partitions in 11-12mm th. commercial plywood/MDF on both sides of approved make with 45mmx45mm kail wood battens to proper line and level and finished with 1mm thick laminate on both sides. Partitions to have 100mm x 12mm thick wooden skirting, including coating of anti termite paint, partition to have 50mm x 35 mm cedarwood moulding on top edge , finished in melamine polish . Complete as per drawings , specifications and to the entire satisfaction of Architect and E-in- C.
Providing and fixing 11-12mm plywood/MDF base with paratal wood frame for signage using plywood of approvedmake mounted to line and level on the wall, complete with all fixing arrangements. This is to be finished in PU Paint ‐ colour indicated in the drawings (SIRCA or ASIANmake
Providing and fixing of 19-20 mm th. engineerded stone/Kalinga Stone (Augusto/Amelia) on columns/walls to be fixed over 10mm th. Bison Board/E board of everest make with adhesive and providing and fixing 1"x1" M.S. Angle framework etc as shown in drawings complete in all respects as directed by the E-in-C.Basic rate of stone upto Rs.450/- per sqft
Providing and fixing of 12mm thk. acrylic Solid Surface (Blue staron) complete with 1"x1" thk SS grade 304 Framework with the manner as shown in drawings complete in all respect as directed by the E-in-C. (DUPONT CORIAN,LG or SAMSUNG STARRON make)
Providing and fixing of 4mm thk. Laquered Glass (spec. indiacted in the drawings) complete with ply boxing/base with the manner as shown in drawings complete in all respect. (SAINT GOBAIN or ASAHI make)Providing & Fixing of lacquer glass as per approval in any color fixed with clear neutral silicon of make GE windily 20/ slipup or Dow Corning 995 on a perfectly leveled MDF of minimum 12mm thickness mounted on the RCC wall/any other structure. The Lacquered glass shall be highly durable, humid resistance, polyurethane lacquer glass. The glass to be manufactured by industrial curtain coating process. It should meet quality standards as per BS EN 1036 1999 & conform to persoz hardness test of at least 220 oscillations. The substrate of the glass should confirm to Standard BS EN 572 1995 parts 1 & 2. Lacquered glass to be manufactured to tight specifications, relating to consistency of color,opacity and homogeneity throughout production campaigns and also to the ageing properties,mechanical resistance, and resistance to humidity and to chemical agents of the lacquer. The color of the lacquer should remain stable when exposed to normal levels of ultra-violet light in interior applications.
Providing and fixing of Titanium coated Stainless Steel sheet ( 1mm thk., Grade 304) (colour and spec. indicated in the drawings) complete with ply boxing with the manner as shown in drawings complete in allrespect. (MAPLE or FABRINOX make) . The sheet to be machine bent in desired shape and size.
Providing and fixing of Titanium coated Stainless Steel sheet ( 1mm thk., Grade 304) (colour and spec.indicated in the drawings) mounted on MDF Beeding 40mm*40mm complete with the manner as shown in drawings complete in allrespect. (MAPLE or FABRINOX make). The sheet to be machine bent in desired shape and size.
Providing and fixing 12mm thick toughened glass in/above the partitions . Complete as per drawings, specifications and to the entire satisfaction of Architech and E-in-C. .
Providing and fixing wooden/flush doors in wooden partition with same specifications as per partition with necessary hardware of ss finish. The door to include the cost of wooden chaukhat of size 125mm x 75mm. Complete as per drawings , specifications and to the entire satisfaction of Architect and E-in- C.
Providing & fixing 35mm thick solid flush door shutters with block board core as per I.S. No. 1659‐1969 bounded with water proof type phenol fromaldehyde synthetic resin hot pressed, Conforming to I.S 2202 part I and II fixed in position, including iron hinges, screws, godrej locks, door closer, handle stoper, cleats and 1 mm Laminate on both sides & polish on chowkat of matching color etc. (excluding the cost of any fittings other than specified, but including labour for fixing the same in position decorative veneering with vertical grains cross bands and face veneer on both sides teak facing and edges lipped with commercial hard wood with laminated core including cost of hardwood chowkat as specified in the drawing and as directed by the E-in-C.
Providing and applying POP punning upto 12mm thick layer of superfine POP applied over plastered surface of walls and columns finished smooth including surface preparation by hacking , sand papering including all incidentals, making grooves as directed, pattas, sills etc. The finished surface to be smooth and in perfect plumb, line and level, Complete as per drawings , specifications and to the entire satisfaction of Architect and E-in- C.
Providing and applying 3 or more coats of special quality plastic paint of approved manufacturer on ceiling, walls and other surfaces evenly to produce even surface. The cost shall include providing and applying 3 coats of Birla /Acrylic putty and paint coats to finished with roller to give impression of small granules. Complete in all respects as directed by the E-in-C.
Providing and fixing 3mm thick Aluminum composite paneling (ACP) of required shade i.e. silver/blue/off white for false celling, on walls /columns/pillars etc. over 1.5 inch x 1 inch Alum. tube including section tube for celling, including 6mm thic grovving after every 2 ft. wide panel and filling the groves with silicon. Including cutting for fency lights complete as per drawings , specifications and to the entire satisfaction of Architect and E-in- C.
Providing and fixing cabinet in 19mm thk. ply finish with laminate approved make behind cash counter as per as architectural drawings complete in all respect, as directed by the E-in-C.
Providing and fixing of 12 mm thick glass shelves on wall panneling finished with 4 mm thick mirror clading and making grooves in ply to hold as per the architectural drawings complete in all respect .
Providing and fixing the cash counter (1800x600mm) finished and complete in all respects as per drawing. Making a 12mm plywood structure fully laminated 21091 CMR with fevicol SH, including cash drawers as per size on hettich telescopic channels, Proper space for CPU's and wire managers. Making the 12mmAcrylic solid surface top (as per spec in drawings) on a 12mm plywood base (of approved make and shade) and side.
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respects as per drawings and to the entire satisfaction of the E-in-C
Providing and applying 2-3 coats of Birla /Acrylic putty wherever required with smooth finished Complete in all respects as directed by the E-in-C.
Providing and applying 2-3 coats of special quality plastic emulsion paint of approved manufacturer on ceiling, walls and other surfaces evenly to produce even surfaceand finished smooth . Complete in all respects as directed by the E-in-C.
Finishing walls with textured exterior paint of required color and shade of approved make with two coats applied @ 3.28 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm Complete in all respects as directed by the E-in-C.
Providing and applying Distempering with Acrylic washable oil bound distemper (of approved manufacturer to the approval of Engineer Incharge to coats over one priming coat to give an even shade including preparartion of surface etc complete in all respects and directed by the Engineer Incharge.
SUB HEAD-11 WATER SUPPLY
Providing and laying, jointing, fixing, testing G.I. Pipe Lines B- Class of approved quality, dully painted with synthetic enamel paint in all shades, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in walls/under floor/trenches etc. at any floor. Complete in all respects as per drawings and to the entire satisfaction of the E-in-C.
a) 15mm i/d
b) 20mm i/d
c) 25mm i/d
d) 32mm i/d
e) 40mm i/d
f) 50mm i/d
Providing, fixing and jointing Union Couplings in G.I. pipe lines as directed by the E-in-C.
a) 15mm i/d G.I. Union
b) 20mm i/d G.I. Union
c) 25mm i/d G.I. Union
d) 32mm i/d G.I. Union
e) 40mm i/d G.I. Union
f) 50mm i/d G.I. Union
Providing, fixing and jointing gun-metal ball valves (Heavy Pattern) with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings. Complete in all respects to the entire satisfaction of the E-in-C.
a) 15mm i/d Gun Metal ball valve heavy pattern.
b) 20mm i/d Gun Metal ball valve heavy pattern.
c) 25mm i/d Gun Metal ball valve heavy pattern.
d) 32mm i/d Gun Metal ball valve heavy pattern.
e) 40mm i/d Gun Metal ball valve heavy pattern.
f) 50mm i/d Gun Metal ball valve heavy pattern.
Cutting holes upto 23cm square for pipes in flooring and roofs of bricks, tiles with lime concrete or cement concrete and making good including repointing, replastering and colour or white washing where required. Complete in all respects to the entire satisfaction of the E-in-C.
a) Through floor or roof 7.5cm thick
b) Through floor or roof 11.5cm thick
c) Through floor or roof 15cm thick
Cutting holes upto 23cm square for pipes in floor and roofs of cement concrete, reinforced concrete or reinforced brick work and making good including repointing, replastering, replacing bitumen and colour or white washing where required.
a) Through floor or roof 7.5cm thick
b) Through floor or roof 11.5cm thick
c) Through floor or roof 15.00cm thick
SUB HEAD-12 SAINTERY INSTALATIONS
Providing and fixing in position SWR UPVC (TYPE-B) soil waste vent or antisyphonage pipes as per IS-13592 of approved make- Supreme (to the approval of E-in-C) including cutting, jointing, wastage, including cost of jointing complete in all respects.
a) 160 mm o/d SWR UPVC pipe line laid complete
b) 110 mm o/d SWR UPVC pipe line laid complete
c) 90 mm o/d SWR UPVC pipe line laid complete
d) 75 mm i/d SWR UPVC pipe line laid complete
Providing and fixing PVC Floor traps conforming to I.S.I. Specification of reputed firm of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. minimum depth of water should be 150mm with a minimum seal 50mm. Complete in all respects as directed by the E-in-C.
a) With 75 mm o/d outlet deep seal
b) With 90 mm o/d outlet deep seal
c) With 110 mm o/d outlet shallow seal
Providing and fixing in position Chinaware (White Colour) Wall hunged European type water closet suite single symphonic type (Make Hindware/Cera/Perryware) with P trap or S trap( to the approval of Enginner-in-Charge ) with 10 ltr. Chinaware matching flushing system including cost of solid white cover and lid complete in all respects and to the entire satisfaction of Engineer in Charge.
Provding and fixing in position best Indian make lavatory suit (wash hand basin) size 49 cm. dia (above counter - round) of white colour (Make Hindware/Cera/Perryware) glazed earthen ware including C.P. brass waste 32mm dia in walls, CP bottle trap, CP brass pillar tap, stop cock/angle valve of Ess Ess make, PVC connection etc. complete in all respects with necessary fittings including cuttings/ making good the walls and floors and painting of fittings ete. Complete in all respects as directed by E-in- C.
Providing and fixing in position CERA make vitreous Chinaware urinal snow white (model cicly 5025 of size 320mmx300mmx325mm) Senso urinal including sensor. Complete in all respects as directed by E-in-C.
Providing and fixing glass partitions of size 910mm long and 460mm from top reduced to 300mm at bottom for urinals with patch fittings complete in all respects as directed by E-in-C.
Providing and fixing in position towel rails / ring fixed in with rawl plugs embedded in walls with brass screws, complete in all respects including cutting and making good the walls etc. C.P. Brass towel Rails size 20mm dia 450mm long
Providing & Fixing in position 6mm thick mirror (make ASAI/SAINT GOBIN OR equalent approved quality with necessary fittings /fastners complete in all respects as directed by the E-in-C.
Providing & Fixing in position 15 mm i/d bib cock of best quality (as approved by the Engineer-in-charge).
a) C.P. brass Bib cock long nose
b) C.P. brass Bib cock
c) C.P. brass Pillar cock
Providing and fixing in position C.P. Brass 15mm concealed stop cock with flange. Complete in all respects as directed by the E-in-C.
Providing and fixing in position C.P. Brass 15mm concealed Angle Valve. Complete in all respects as directed by the E-in-C.
Providing & Fixing in position liquid soap container of best quality (as required by the Engineer-in-charge).
a) C.P. brass liquid soap container (Heavy type)
Supplying & fixing in position stainless steel sinks 1mm thickness grade 304 (Neelkanth make) Double bowl sink overall size 1100mmx475mm, bowl size 463mmx388mmx200mm including waste coupling complete in all respects including cutting in granite etc and making good the walls and floors. complete as directed by E-in-C.
Supplying & fixing in position SS sink size 530mmx450mmx175mm (Single bowl) of Neelkanth make to be got approved before arranging complete in all respects including, waste coupling etc and cutting, making good the walls and floors, painting of fittings etc. complete as directed by E-in-C.
Providing and fixing vainty counter (with hand wash basin) of size 800x400x460mm with stainless steel shutter and body, including the cost of neccsary fitting complete in all respects, as per manufacturer's specifications .
Providing and fixing in position snow bite Hindware make wall hang EWC with concealed flusing system push plate, white seat cover with lid extra complete in all respects ,, as per manufacturer's specifications .
Providing and fixing in position white colour 15mm thick engineered stone for counter slab for fixing and wash basins in toilets including other necessary material required for fixing complete in all respects
Providing and fixing in position stainless steel made from 40x40x5mm angle and 40x40mm square pipe for supporting granite stone slab in the pantery complete in all respects
Providing and fixing in position MS for supporting engineered stone slab for fixing and wash basin in toilets and man hole cover frame etc complete in all respects
Construction of brick masonary inspection chambers of size as given below upto 0.60 Meter average depth, in 1:5 cement sand mortar, cement concrete 1:8:16 in foundation, cement concrete 1:2:4 benching, 12.5mm thick cement plaster 1:2 with a floating coat of 1 mm thick neat cement, R.C.C. 1:2:4 slab 100 mm thick, cement concrete 1:2:4 topping 50mm thick, with 455mmx455mm , 455mx610mm in light duty C.I. inspection chamber cover and frame (weight as per I.S.I. specifications) painted with three coats of black bitumastic paint conforming to I.S.I. specifications complete as per standard design.
a) Size 450mmx 600mm inside with RCC 455mm x 610mm cover and frame medium duty double seal.
b) Size 600mmx 900mm inside with RCC 455mm x 455mm cover and frame medium duty double seal.
Extra for every 0.30metre depth of inspection chamber
a) Size 450mmx 600mm inside
b) Size 600x900mm inside
Providing and fixing ( health faucet) hand shower with 1mtr long easy flex tubein crome finish and ball hook of Jauger / approved make complete in all respects
Providing and fixing soap dish fixed into walls with CP brass screews complete in all respects
Providing and fixing paper hold of approved make fixed into walls with CP brass screews complete in all respects
Providing, lowering, cutting & jointing salt Glazed Stone ware Pipes and Specials ISI marked as per IS 651-2007 class Sp-1 into Trenches for all depths and Laying out the same to correct alignment, Gradients, levels etc., In Trenches including all dressing and trimming of bed and sides of trenches, including excavation and PCC 1:6:12, supporting the pipes and specials, in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching, haunching and envelopes are completed. The sewer shall rest on the bed at every point through-out its length and to ensure this, it shall be grouted in without extra charge by the contractor with 1:3 cement sand mortar including jointing of pipes and specials in trenches, using cement sand mortar 1:1 and best white italian spun yarn, finishing and trowelling of each joint at an angle of 45degree with the longitudinal axes of pipe, watering, keeping the joint covered and wetted till the same are cured, testing the sewerage line for leakage and making all leakages and defects good as laid in the contract specification, complete in all respects.
150 mm i/d SW pipe sewer laid complete.
100 mm i/d SW pipe sewer laid complete.
Providing and fixing in position gully traps fixed in c.c.1:4:8 complete with grating 150mm X150mm, cover and frame clear opening 300mm X300mm and out of side330mmX330mm and chamber including cost of bricks work in cement morter 1:5 ,cc 1:2:4 in coping around cover and frame etc. with three coats of black bitumatic superior pain lf approved manufacture on all C.I. work as per standard deign minium depth of water should be 150mm with minimum seal 50mm complete in all respects.
a) 100mm internal dia S.W. gully trap with HCI grating and cast iron cover weighing approximately 7.26 Kg and frame clear opening 300mmX300mm and out of side size 330mm x330mm
Supplying & fixing in position stainless steel Drain Jali 2mm thickness grade 304, size as per site requirements ( To be got approved before arranging) complete as directed by E-in-C.
SUB HEAD-13 ELECTRICAL INSTALLATION SURFACE CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: MAKE- Havells, Legrand/approved
Wiring in PVC insulated copper conductor single core FR cable (ISI marked), 1100volts grade to be laid in heavy gauge, PVC, fire retardant conduit pipe 20mm/25mm dia. (2mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules, for having electronic fan regulators, bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20Amp. Sockets and 6Amp./16/20Amp. Switches (Screw Type Modular Accessories) etc., and covered with Frame Plate etc., & including the cost of required number of modular switches/sockets, step type electronic fan regulator 100watts, PVC connector (For Fan Box and Electronic Buzzer), Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) PVC conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of changes. Complete in all respects as directed by E-In-C.
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm,1100volts grade. with single control switch.
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with double control switches(two way switch).
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm,1100volts grade complete without control switch.
Wiring Fan point- controlled by one switch in PVC insulated copper conductor single core FR cable (ISI marked to the approval of E-in-C). overall 1.5 sq. mm, 1100volts.
Wiring call-bell point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with bell push and electronic buzzer 230 volts AC (including the cost of bell push, electronic buzzer & powder coated concealed metal box for electronic buzzer).
Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FR cable (ISI marked) overall 1 sq. mm, 1100volts grade.
Wiring 3 Pin 6 Amp. Plug control comprising wall socket(shuttered) and switch including bonding to existing earth with PVC insulated copper conductor single core FR cable (ISI marked) overall 1 sq. mm, 1100volts grade complete.
Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch.
Wiring TV sockets and Telephone socket points in powder coated/anodized concealed metal boxes recessed in wall/under floor required for suitable number of modules, for having TV sockets, Telephone sockets RJ11 & RJ45 (one module) etc., and covered with Frame Plate etc., & including the cost of required number of modular TV sockets, Telephone sockets RJ11 & RJ45 (one module) and other petty material etc. including the cost of cutting and filling up of chases complete as directed by the E-in-C.
a) Wiring of TV socket point (one module) including T.V. Jack .
b) Wiring Telephone socket point (one module) including Telephone Jack RJ - 11.
c) Wiring Computer socket point (one module) including Computr Jack RJ -45.
Supplying and erection of P.V.C. insulated single core FR copper conductor cable (ISI marked - to the approval of E-in-C) left bare in pipe or casing of suitable size, excluding the cost of supply and erection of pipe or casing. Complete in all respects. Note:- (Extra rate will be payable only beyond the individual point’s control panel/ board to main D.B. panel)
a) PVC insulated copper conductor single core FR cable overall 1 sq.mm, 1100volts grade.
b) PVC insulated copper conductor single core FR cable overall 1.5 sq.mm, 1100volts grade.
c) PVC insulated copper conductor single core FR cable overall 2.5 sq.mm, 1100volts grade
d) PVC insulated copper conductor single core FR cable overall 4 sq.mm, 1100volts grade
e) PVC insulated copper conductor single core FR cable overall 6 sq.mm, 1100volts grade
f) PVC insulated copper conductor single core FR cable overall 10 sq.mm, 1100volts grade
g) PVC insulated copper conductor single core FR cable overall 16 sq.mm, 1100volts grade.
Supplying and erection of Miniature circuit breaker (MCB’s) single pole 6 to 32 amp (Breaking capacity 10 kA, Curve-C) suitable for 240/415 volts 50 cycles AC supply, to be fixed in the new/ existing MCBD’s including necessary connections, testing and commissioning etc. complete in all respects as directed by the E-in-c. Make Havells/ Legrand/ Schneider or equivelant approved
Supplying and Erection of heavy gauge PVC conduit pipe, fire retardant for wiring purpose - 25mm dia (ISI marked recessed in wall/ on surface) of an approved quality. Including the cost of bends, sockets, inspection boxes etc. complete in all respects as directed by the E-in-C. Note:- (Extra rate will be payable only beyond the individual points control panel/board to main D.B. panel).
Supply and erection of G.I. Pipe- (B Class to the approval of E-in-C) for wiring/Cable purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010 complete in all respect as directed by the E-in-C.
a) Galvanized iron pipe 32mm dia flushed / under floor etc.
b) Galvanized iron pipe 40mm dia flushed / under floor etc.
c) Galvanized iron pipe 50mm dia flushed / under floor etc.
Supply and fixing single pole blanking plate in the switch board complete as directed by the E-in-C
Fabricating and installing following size of perforated MS galvanised cable trays including horizontal and vertical bends, reducres, tees, cross members and other accessories as required and duly suspended from the ceiling with suspenders etc. as required and directed by the E-in-C
a) 40 x 200x40x2mm thickness MS, zinc galvanized cable tray
b) 40 x 150x40x2mm thickness MS, zinc galvanized cable tray
c) 50 x 100x50x2mm thickness MS, zinc galvanized cable tray
d) 75 x 400x75x2mm thickness MS, zinc galvanized cable tray
e) 50 x 300x50x2mm thickness MS, zinc galvanized cable tray
Supply and laying PVC DLP channel 100 x50mm consisting of internal angle, external angle, Tee, cable divider, cable retainer end cap and cover etc. with all calping and fixing accessories for networking cable system complete in all respects as directed by the E-in-C.
Supply and fixing of call bell / buzzer A.C. 230V, Single Pole. Make Anchor/Havel/ or equivalent approved by the E-in-C.
Supply and erection of PVC flexible pipes (fire retardant) for wiring purposes including bends, inspection boxes etc., where necessary including other petty material as per PWD General Specifications 2010 complete in all respects as per site requirements.
a) Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) On Surface
b) Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) On Surface
Supply and laying of voice / data wires in existing conduits / raceways and terminating with RJ-45 terminals for data & RJ-11 terminals for voice as indicated on site / drawing.
a) Cat 6 cable for voice outlet for internet facility and networking station and terminating with RJ-45 and RJ -11 terminals for networking and voice data. Make :- Legrand/Systimax or equivalent approved .
SUPPLY AND LAYING OF LT CABLES ON CABLE TRAYS or in PVC CONDUIT / PVC DLP TRUNKING ETC.:- XLPE INSULATED ARMOURED CABLES make RR cable / Rallison / Havels
a) 2 Core x 2.5 Sq. mm Copper Conductor Armd.
b) 4 Core x 4 Sq. mm Copper Conductor Armd.
c) 4 Core x6 Sq. mm Copper Conductor Armd.
d) 4 Core x 10 Sq. mm Copper Conductor Armd.
SUPPLY AND FIXING OF LIGHTING LUMINARIES CONSISTING OF LIGHTING FIXTURES, TUBE ROD / CFLS/LED LAMP AND ALL INTERCONNECTED WIRING. MAKE PHILIPS/WIPRO /HALONIX OR EQUIVALENT MAKE APPROVED BY THE E-IN-C BEFORE FIXING, DETAILS GIVEN UNDER:- Supply and fixing of recessed mounted600x600mm, 35 Watt high power led fixture having256 nos. of led, p.f. >0.9, view angle 120 deg.,smps based constant driver and complete as per manufacturer's specifications, drawings, and to the entire satisfaction of Architect and E-in-C.
Supply and Erection of Green LED – 900 ( 15 watt ) light panel (Cool white) Philips make complete in all respects as directed by the E-in-C.
Supply and fixing of fluorescent tube fitting T-5-28 Watt complete with rod, copper choke, starter, capacitor, click-fix holders etc. complete with all accessories, make Surface type . complete as per manufacturer's specifications, drawings, and to the entire satisfaction of Architect and E-in-C.
SUPPLY AND FIXING CEILING FANS - DOUBLE BALL BEARING TYPE MAKE HAVELS/USHA/BAJAJ ULTIMA/CROMPTON HIBREEZE MODELS Supply and fixing of 48” (1200mm) sweep ceiling fan, double ball bearing suitable for operation on 230 volts, 50 Hz single phase A.C. supply complete and with necessary down rod with fan regulator etc. , complete in all respects, as directed by the E-in-C.
Supply and fixing of wall mounted cabin fan 450 heavy duty OSE type with tilt angle adjustment having 3 speeds including built-in regulator suitable for operation on 230 volts, 50 Hz single phase A.C. supply complete in all respects as directed by the E-in-C. make: Havells/USHA/Crompton Hibreeze model.
SUPPLY AND FIXING - EXHAUST FANS DOUBLE BALL BEARING, TYPE POWDER COATED WITH SUITABLE LOUVERS MAKE HAVELS/USHA/BAJAJ ULTIMA/CROMPTON HIBREEZE MODELS
a) Supply and fixing exhaust fan 9" (225mm sweep)
b) Supply and fixing exhaust fan 12" (300mm sweep)
c) Supply and fixing exhaust fan 18" (450mm sweep)
Supply and erection of 3 core PVC copper insulated and sheathed circular feasible wire for street light luminaries. Complete in all respects as directed by the E-in-C.
a) 1.5 Sq. mm (48 / 0.20 mm)
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc. GROUP-A: (Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA), Hager.
a) Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's,12 way each complete in all respects.
b) Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's, 8 way each complete in all respects.
c) Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's, 4 way each complete inall respects.
d) Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's, 8 way each complete in all respects.
Earthing of sheet metal /iron clad switches and metallic cases etc.,with (32mm X 6mm) thick G.I.strip rivetted to (30cm X 120cm X 6mm) thick G.I. plate (made cylinderical) buried 4.5 metre below ground level surrounded bysalt and charcoal dust mixture including fixing the G.I.strip on wall and in floor etc., with G.I. stapples of suitable size upto required depth of 9 mtr. complete in all respects.
Earthing of S.P. & N. distribution board with GI wire no. 8 (6mm dia.) as required for lighting DBs. Complete in all respects.
Supply and erection of 32mmx6mm thick G.I.strip (as additional length) complete in all respects.
Supply and errection of MCB Double pole 6to 32 amp. ( breaking capacity 10ka, curve-c) L&T make or equvalent approved make suitable for 240/415 v 50 cycle AC supply. Complete in all respects.
Supply and errection of MCB four pole 6to 32 amp. ( breaking capacity 10ka, curve-c) L&T make or equvalent approved make suitable for 240/415 v 50 cycle AC supply. Complete in all respects.
Supply and errection of MCB four pole 40 amp. ( breaking capacity 10ka, curve-c) L&T make or equvalent approved make suitable for 240/415 v 50 cycle AC supply. Complete in all respects.
Supply, assembly, erection, testing and commissionining indoor type floor mounted free standing dust and vermin proof panel with IP-54 protection fabricated out of suitable sized angel iron and flats and covered with 2mm thick CRCA sheet duly pretreated in seven tank process for de-greasing, de-rusting and phosphated painted with 2 coats of primer paint then the panel/DB surface shall be finished/rubbed and then painted with final coat of epoxy based powder coated paint. Panel/DB shall be compartmentrised with rubber gasketed hinged door with lock. Panel/DB shall be having Front and Rear opening for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & outgoing cables. A clear space of 200mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals to be provided for connecting cables. Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided as per respective schematic drg. of the panel with the following equipments / instruments. Paint shall be epoxy based DANCOT/Asian make as per shade approved by Engineering Incharge. Each Compartment shall be numbered / lettered as per the approved drg. affixing MV Danger plate at suitable intervals/locations. Switch Gear Make L&T / Schinider / Siemens/ Legrand. Incoming TPN MCCB 250A, 50KA with TM release CTs , Digital Ammeter, ASS, Digital Voltmeter, VSS, Phase Indicating lamps etc. Busbars Manufacturing specifications of busbar cubicle as per current rating capacity of TPN Copper busbar 150A E91 grade Outgoings Manufacturing specifications of out going compartment rised feeders and cable alleys shall be as per following switchgear
Power Control Centre for Air Conditioners Complete as per above.
Providing and Fixing of Lighting Fixtures
a) LED‐PREVALED COIN III G2‐32W‐4000K‐40deg. (OSRAM or equivalent
b) LED‐PREVALED COIN 50 G2‐13W‐4000K‐24deg. (OSRAM or equivalent)
c) LED‐COB‐6W‐4000K (OSRAM or equivalent)
d) LED‐COB‐2X10W‐4000K (OSRAM or equivalent)
e) 32W‐OSRAM‐PREVALED COIN IIIG2‐4000K‐40 deg. (OSRAM or equivalent)
f) 20W DOWNLIGHTER (OSRAM or equivalent)
g) LED STRIP LIGHT (10W/MTR)‐4000K (OSRAM or euivalent)
h) LED FLAT PANEL 2'X2'‐36 W‐4000K (OSRAM or equivalent)
SUB HEAD-14 A) FIRE DETECTION & FIRE FIGHTING
Supply, Installation,Testing & Commisioning of Microprocessor based 1 loop fire alarm control panel fully networkable,expadable with each loop capable of taking 99 devices and 99 modules , 1 line x 40 character alpha-numeric liquid crystal display.The panel shall be soft addressable type. The Panel should be able to store 500 log events in it's Memory. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, option to have built in printer to log all fire or fault events complete in all respects, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification VDS & CNBOP approved.
Supply, Installation, Testing & Commissioning of Analog Addressable Intelligent multisensor detector, soft addressable Photo thermal ( Dual Optical with Forward and backward scattering & One Thermal Chambers) type with inbuilt fault isolator complete with base as required
Supply, Installation, Testing & Commissioning of Addressable Manual Call Point soft addressable type with in built fault isolator complete as required
Supply, Installation, Testing & Commissioning of Addressable transponder/ Monitor Modules 4 input and 2 output for monitoring flow switches/Fire exit doors etc complete as required
Supply, Installation, Testing & Commissioning of Addressable transponder/ Control Modules 12 output for controlling AHU/Lifts etc complete as required.
Supply and pulling of 2 x 1.5 sq.mm copper armoured FR cable
B) FIRE FIGHTING SYSTEM Providing and fixing of M.S. Pipes (C- class ) confirming to IS 1239 PT-1 having grade including all fittings like couplings, bends elbows, blind flanges plug, tees, flanges etc. welding joints all type as reqd. supports cutting holes and chases in brick or RCC walls or floors with wrapping coating with 2 mm pypercoat sheet complete in all respects.
a) Size 80 mm
Providing and fixing single head landing valve confirming to IS–5290 with 63 mm dia instantaneous female coupling on the outlet with heavy, orifice flange 5 mm thick as required to maintain 3.5 kg/sq. cm. Gunmetal blank cap and chain necessary companion flanges nuts, bolts, washer and gasket complete as per specification ISI make
Providing and fixing 63 mm dia 15 mm long rubberized rubber lined hose RRL including gunmetal male and female instantaneous type coupling, machine wound with copper wire complete in all respects. Hose shall confirming to IS–636 type II and coupling to IS 903–1975 ISI make
Providing and fixing standard short size gunmetal branch pipe with nozzle 16 mm dia Outlet with standard instantaneous type 63 mm dia coupling ISI make
Providing and fixing of C.I full way valve confirming to IS 778 class – 11 screwed type complete in all respects.
Providing and fixing fire hose cabinet fabricated from 18 gauge M.S. sheet with single or double glazed from door and locking arrangement P.O. red painted with including suitable support place 900 mm above ground level. Size 750x250 mm deep. House two set of RRL hose and short branch
Providing and fixing of swinging type first aid fire hose rill with 30 Mtr. Long discharge rubber pipe of 20 mm diameter with shut off nozzle of 5 mm diameter globe valve and fitting complete as required and as per IS894
Providing & fixing of ISI marked (IS:940) portable chemical Fire Extinguisher, water (gas pressure) type capacity 9 ltrs with gun-metal cap. and nozzle and complete in all respects including initial fill and wall suspension bracket.
5 kg Mono Ammonium Phosphate (ABC) type cartridge operated extinguishers
Providing and fixing DCP Type Wall Mounted Modular Capacity of 5Kg , Operating with heat sensitive glass Bulb Sprinkler 57 Degree functions as a heat detector Cum Discharge Head on Temperature below the extinguishers
Providing & fixing of ISI marked (IS:2878) portable fire extinguisher, carbondioxide type flat base including valve, discharge hose of not less than 10 mm dia. 1 M long & complete in all respects including initial fill with CO2 gas confirming to IS:307-1966 filled to a filling ratio of not more than 0.667 of not more than 0.667 and wall suspension bracket. Capacity 4.5 kg Note :- The Successful tenderer shall obtain N.O.C. from the concerned Fire Officer, in regard to fire fighting system.
SUB HEAD-15 VRF (Variable Refrigerant Flow ) System
Supplying, installation, testing, and commssioning of MISUBISHI, or Equivalent VRV/VRF system of based on digital/vapour njection/inverter scroll technology complete with indoor and outdoor units with individual controller and with refrigerant piping, control cabling suitable for ambient conditions and as per detail given inspecifications and having following items : Outdoor Unit SITC of aircooled variable refrigerant volume modular type airconditioning system with R410a refrigerant suitable for 415±10%, 50 cycles.The unit shall consist of indoor and outdoor units with individual controller Modular type outdoor units equipped with highly efficient inverter type 100% inverter scroll type compressors with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and Outdoor unit suitable for Cooling & Heating of following capacitites: SITC of Distribution Board, isolators, Cables, earthing etc. of suitable ratings for outdoor unit. *The ODUs shall be placed on MS Channel 100 x 50 mm by contractor duly painted &grouted as per drawings. The contractor/ company must quote as per below mentioned capacities as minimum.
a) 8 HP outdoor unit including Header
b) 12 HP outdoor unit including Header
b) 18 HP outdoor unit including Header
Indoor Air Handling Units :- Supplying, installation, testing, and commssioning of MISUBISHI,or Equivalent Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities as per specifications and drawings. The units shall be suitable for 230V±6%, or 415V±10%, 50 Hz. supply & complete with electrical controls & panels. The cost of indoor unit shall include the cost of wire with plug top (assuming wire (3X2.5Sqmm) length of 8 to 10 Meters as per drawing), including SITC of Fire retardant non porous double layer flexible canvass connection between eachindoor unit and duct as per approved drawings and specifications. Cassette type indoor unit
Ductable Split Unit
Supplying, installation and testing of Hi Wall type Indoor unit as per detail given below of MITSUBISHI OR EQUIVALENT APPROVED MAKE complete in all respects.
a) 1TR Hi wall Type Split A/C
Supply, erection and commsioning of Corded Remotes with for Indoor Aircondioner units complete in all respects
Supply, erection and commsioning of Joints of different sizes inrefrigerant Copper piping work as per site requirement complete in all respects .
Supplying, installation, testing and commissioning of following sizes of refrigerant copper piping work (Mandev/Max Flow/ Total Line/ RajcoCopper Piping ) with 19/13mm thick closed cell elastomeric nitrile rubber tubular insulation (A-Flex/K-flex/ Superlon Insulation) between each set of indoor and outdoor units as per specifications duly painted with protective ultra violet paint complete as required. All piping works inside the class room shall be duly supported with MS hangers and clamps complete in all respects.
a) 44.5 mm outer dia (insulation 19mm)
b) 41.3mm outer dia (insulation 19mm)
c) 34.93mm outer dia (insulation 19mm)
d) 28.6mm outer dia (insulation 19mm)
e) 22.2mm outer dia (insulation 19mm)
f) 19.1mm outer dia (insulation 13mm)
g) 15.9mm outer dia (insulation 13mm)
i) 12.7mm outer dia (insulation 13mm)
j) 9.5mm outer dia (insulation 13mm)
k) 6.4mm outer dia (insulation 13mm)
Supply and installation of cable tray of following sizes including horizontal and vertical bends, cross member duly supported with suitable hangers and supports complete as required. complete in all respects..
a) 150mm (wide) x 50mm(depth) x 1.6mm (thick)
Providing and fixing UPVC drain piping complete with fittings, insulated with 6 mm thick closed cell nitrile rubber insulation duly suported with suports as per specifications and requirement.
a) 32 mm dia
Supply, Installation, Testing and Commissioning of control cum transmission wiring of 2 core x 1.50 sq mm copper wire in suitable PVC conduits between indoor & outdoor units to central remote controllers & for connections between indoor unit to outdoor unit
Supplying and laying Remote Controller wire ( core 0.75 mm) from indoor unit to remote , complete in all respects
Supplying and Charging of Gas R-410 in the above said unit (system with R-410A) and circuit omplete in all respects.
Air Distribution Supplying, installation, testing and commissioning of air distribution fabricated GI sheet metal ducting as per ISI specification complete with supports,Nut bolts, Gasket etc as per site requirement complete in all respect.
a) 24 Gauge (0.63 mm)
b) 22Gauge (0.80 mm)
Supplying, installation, testing and commissioning of closed cell Nitrile rubber insulation Class O of following thickness applied with proper adhesive and sealed with 75 mm wide BOPP Tape on all longitudinal/ transverse joints complete as per specifications
a) 9 mm thk on ducts in conditioned/inside space
Supplying, installation, testing and commissioning of Nitrile Accosound Insulation inside of the duct pasted with suitable adhesive as drawings and specifications of following sizes.
a) 12 mm thick
Supplying, installation, testing and commissioning of Grills/Diffusers/VCDs complete in all respect.
a) Extruded aluminum construction Linear Grill as per approved drawings and specifications. for supply Air & returm Air
b) Powder coated MS constructed construction posed blade volume control damper for grill.
c) Powder coated extruded aluminum construction Fresh Air Louvers with Bird screen as per approved drawings and specifications
d) 16 Gauge GI construction volume control dampers to be fixed in ducts as per approved drawings and specifications
e) Powder coated extruded Fresh Air Gravity Louvers
f) powder coated extruded aluminum, 12 x 12 Inch, ceiling diffusers with removable core and anti smudge ring with black painted MS volume control damper as per approved drawings and specifications for Supply Air.
Supply of Greenguard certified Godrej/Geeken make ( to be got approved ) rectangular modular workstations of size mentioned below and thickness of panels 69mm. The trim width shall be 69 mm and the thickness of panel after fitting the tiles on frame is should be 65mm (+/- 1.5 mm). Height of the Panels shall be 1190mm. The framework shall be a welded rectangular frame made up of 2 vertical sections welded to horizontal tube at the top and C-channel at the bottom, along with intermediate horizontal members which shall fit into vertical members slots, to accommodate cladding tiles of different heights, and to form a rigid structure. The finish will be powder coated in standard neutral color. The vertical sections shall be made up of 1.5mm thick CRCA MS grade D (as per IS: 513-1994) formed into C channel of 41.5 X 50MM. The uprights shall have the rectangular slots to carry wires, 1 no. at the bottom & 2nos. at the intermediate levels, of size 60mm (H) x 18mm (w). The pitch for mounting the brackets shall be 25.4mm. Top horizontal shall be 1.2 mm thick MS tube of 25.4 x 25.4 mm (1 x 1 inch). The bottom horizontal shall be 1.5mm thick C-channel, of MS CRCA Grade D, size 38.1mm x 25.4mm (1 ½ in x 1 in). The bottom horizontal shall also have 2 slots for carrying wires, which will be of size 100mm (L) x 20mm (w). The panels shall have levelers made out of nylon studs with screw insert with adjustment of +10mm. Exposed vertical and top edges of panels shall be covered with trims and top caps. Trims shall be of 69 mm W X 10.5 mm H and average wall thickness of 1.0 mm. These trims shall be made from Powder coated aluminum alloy (of grade He-9 – 63400) extrusions. The trims shall be fitted on the top horizontal using M6 X 35L Nut-bolts and the open vertical ends of the upright using M6 X 25L Bolt & Nut. The caps shall be made of ABS material, PU coated in color desired or matching to trim color. Tiles above worktop shall be Fabric Magnetic type made up of 0.6mm thick GI sheet metal tiles upholstered with Fabric. Tiles below work surface shall be plain metal tiles of thickness 0.6mm mild steel CRCA grade as per IS-513-1994. Metal fascia shall be powder coated, in 0.8 mm thick M.S. CRCA Grade D as per IS: 513 -1994, which will be mounted with a hook at bottom and Snap fit button on top (BLACK). These can be provided at the bottom level as well as at the beltline level above or 6” below the worksurface. The fascia could be with or without cutouts for mounting of switches. Work top shall be made of 25mm thick pre-laminated particle board interior grade (As per IS: 12823).
Bottom shall have a backing laminate of minimum 0.6mm thickness. All the edges of work surface shall be provided with machine pressed 2 mm thick PVC Edge band glued with hotmelt EVA glue. The side panel shall be made from 25 mm thick. PLT particle board (As per IS:12823) and it is edge banded all over with machine pressed 2 mm thick PVC lipping glued with hotmelt EVA glue. The side panel shall be fitted with M6 Glide screw for height adjustment. The work surfaces shall be mounted on the New 13” inch work surface bracket of 2.0mm thick M.S. A corner bracket shall be used to support the work surface at the corner junction of the frames. Side panels will be attached to the upright using the side panel brackets. All M.S. components shall undergo 2 stage single chemical spray phosphate pre-treatment which is environment friendly. Greenguard Certification copy of the modular workstation shall be submitted along with tender. 1 metal Key board tray, 1 metal CPU Trolley & 1 free standing 3 drawer metal pedestal of size 390 W x 435 D x 646 Ht shall be provided.
a) Workstation size W 1500 X D 600 With wire manager hole.
b) Workstation size W 1200 X D 600 With wire manager hole.
) Workstation size W 900 X D600 With wire manager hole.
General Notes:- 1 . Item wise rates shall be quoted by the tenderers based on the specifications mentioned in the DNIT/Scope of work/ latest edition of the Punjab P.W.D. specifications supplemented with relevant I.S. code including subsequent Addenda and Corrigenda issued from time to time . 2. In case of works below ground level like basement of buildings and public health works such as sewers, disposal works etc, the rates upto a depth of 4 metres below ground level, shall be the same as for work in 2nd storey. For depths greater than 4 metres, additional rates for subsequent storeys shall be added. For works which are not deeper than 1.5 metres from ground level, ordinary rates for works in foundation and plinth shall apply. 3. Measurement of centering and steel shuttering work where not included in the complete rate of concrete work shall be taken of the actual surface of steel shuttering in contact with the concrete surface. 4. Coarse sand to be used for concrete work, brick work etc. shall be as per Punjab PWD Specification No. 3.30. 5. All items are inclusive of cost of curing wherever required and protecting in bad whether conditions. 6. Holes or zaris in the brick/RCC work for pipes shall be kept or the pipes shall be provided at the time of raising of masonry/RCC. These holes and zaris should be made good after fixing of pipes and nothing extra shall be paid for such jobs. 7. The quantities mentioned in the schedule of quantities are only approximate, based on preliminary conceptual drawings/sketches and design/details and are meant-primarily to form a common basis for tender analysis. Actual quantities may vary from the quantities given in the schedule and no extra claim of the contractor shall be entertained on this account.
ALPINE INTERIORS
K K AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .