| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹32.2 L+₹3.5 L (12.1%)Rejected-Finance | L2 | Rejected-Finance Being other than Lowest |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
8 Jun 2020, 6:00 pmClosed
CWE NW Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
SPECIAL REPARIS TO BALANCED ROOF TOP AREA WATER PROOFING INCLUDING STRUCTURAL REPARIS IN MIS DEPARTMENT AT NAVAL DOCKYARD MUMBAI UNDER GE NW KUNJALI
2020_MES_344017_1
8356/CWE(NW)/MUMBAI
Open Tender
Civil Works
Item Rate
180 days
GE NW Kunjali
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NW Kunjali
₹66,000
Yes
8 Jul 2020
11 May 2020
10 Jun 2020
11 May 2020
8 Jun 2020
26 May 2020
11 May 2020 - 25 May 2020
Amount
Dismantling wall and ceiling boards (fiber, pulp, insulation, etc. ) or insulation boards / slabs / blankets, any thickness, including cover fillets complete all as specified and directed.
Demolition of plain cement concrete roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and remove debris outside from MD land complete all as specified and directed..
Demolition brick work or stone / boulder masonry, including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles built in cement mortar complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius and built in CM (1:6) complete all as specified and directed.
S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equvalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, complete all as per manufacturer's instruction all as specified and directed.. (Make : Everest or equivalent as approved by GE)
S&F for rolled mild steel sections of Grade Fe 410-W, (Gde- E-250) quality-A, as in post, runners, rafters, purlins, steps etc fixed with connecting plates including bending, welding complete all as specified and directed.
S&F for mild steel plates of Grade Fe 410-W, (Gde- E-250) quality-A as in connecting pletes, base plate etc. welding complete all as specified and directed.
M&L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate, as roof kerbs / padding, using Pidiproof LW+ water proofing chemical of Dr. Fixit or equivalent as per manufacturer's instruction complete all as specified and directed. (Water Proofing Chemical shall be measured and paid seperately).
M&L for roof treatment by application of two coats elastomeric coating of "TECH O THANE PU-White" @ 1.5Kg/SQM in CHOWKSEY CHEMICALS or NITOPROFF 600 PF @1.5KG/SQM in FOSROC or equivalent in IWL etc with DFT of minimum 1mm thickness on primed surface by using special grade of "Primer PR 71" in CHOWKSEY CHEMICALS or NITOPROFF Primer in FOSROC complete all as specified and directed. Note: 1.Rate should be inclusive of removing and refixing the lightening arrestor if existing. 2.Rate should be inclusive of removal and refixing PVC water tanks or shifting of any other thing as existing as per site condition
Making the chajjah tops surface clean, free from dust dirt, grease, oil, followed by applying 2 coats of approved Rubberized / polymer water proofing treatment POLY ALK WP or equivalent of approved make as per the manufacturer’s specifications as specified and directed.
S&F welded steel wire fabric, cut to length, fixed to steel members / reinforcement steel, weigh per Sqm not exc. 4 Kg complete all as specified and directed.
M&L for taking down, chipping and removing the loose, split, damaged cement concrete, cement mortor surfaces of RCC Columns, beams, walls, ceiling, chajjah etc and exposing the reinforced cement, wire brushing and cleaning the exposed steel reinforced bar by washing with clean water for removing all rusts from the old re-bar surfaces and applying rust remover, anti rust coating over cleaned re-bar and fixing new reinforcement if required for strengthen the members and applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified bond coat on affected concrete surfaces and finally providing polymer modified cement and quartz sand mortor in CM 1:3 mix, 40mm thick in two coats, using polymer as per manufacturer's instructions complete all as specified and directed. Make : Dr. Fixit / Sunanda / chemestik / Fosrok Note :- (New reinforcement / steel wire fabric / MS Sections and scaffolding as required will be measured and paid separately)
Material & labour for providing and applying jacketing around columns / beams / other RCC members with Micro concrete (Molith-MC) including all lifts, shuttering, drilling holes and fixing shear anchor / deficient reinforcement as per manufacturer's specification complete. Note: Reinforcement shall be measured and paid separately. (Rates quoted shall be including jacketing, formwork and micro concrete). Make :- Dr. Fixit, STP, Fosroc as approved
M&L for cleaning the surface of wall thoroughly and removal of all loose plaster, dust, oil, wax, grease etc and filling the cracks with cements grouts properly and if required replastering the entire area after taking down old plaster (Plaster will be paid and measured seperately) and applying 2 coats of REINSHIELD OF IWL OR EQUIVALENT in Dr FIXIT AND FOSROC with same properties as per manufacturing instructions for water proofing treatment of wall . Note- 1-Work to be executed in presence of company representative. 2. Rate quoted shall be inclusive of taking down and re fixing of existing things like cable, pipes, etc if applicable complete as directed by Engineer-in-charge.
M&L for TMT mild steel bars, 10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0 complete all as specified and directed.
All as per item No. 15 above but as in stirrups.
M&L for preparation of existing surfaces of roof top, RCC Gutter and parapet wall, crack filling with prime seal chemical and cement @ the ratio of 1:4, applying two coats of water proof chemical (Newcoat of dr. fixit or equivalent) and finally applying a coat of SBR latex and silicon powder paste not less than 2 mm thick complete all as specified and directed.
M&L for providing grouting 12 mm dia holes of 75mm deep @0.6 m c/c at junction of beams and columns as co-ordinal points for inserting / pouring mixture of Lw+, high proof chemicals and cement slurry by pressure grouting for column, beams and slabs, includind sealing the holes with CM 1:3 complete all as specified and directed.
M&L for micro concrete works in repairs of patches like edges, chajjas, lintels and other RCC members complete all as specified and directed.
Supply only polymer SBR Latex or equivalent as approved. Make:- Dr. Fosrok, Sunanda, Dr. Fixit
M&L for erection & dismantling of MS tubular double scaffolding (H frame) upto height of 30m & with necessary brazing, provision of necessary safety equipment to the skilled workers to carry out the work and covering with green cloths for carrying out external face work of walls complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks of capacity 500ltr (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing tanks and remove to store complete all as specified and directed.
All as per item 22 above but 1000 liter capacity.
All as per item 22 above but 2000 liter capacity.
M&L for ready mix polymer plaster 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces in wall finishing the surface even and smooth finish complete all as specified and directed.
M&L for ready mix polymer plaster 5 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces in ceiling finishing the surface even and smooth finish complete all as specified and directed.
M&L for ready mix polymer plaster in CM 1:4 20 mm thick in two coats (15 mm under coat plus 5mm finishing coat) with water proofing compound at the rate of 2% by weight of cement and finishing the surface even and fair complete all as specified and directed.(WPC will be measured and paid seperately).
Supply only integral water proofing compound.
M&L for preparation of newly plastered wall surfaces, over 10cm girth, applying two coats of 100% acrylic, weather resistant emlusion over a coat of exterior wall primer complete all as specified and directed.
M&L complete removal of existing plastered wall surfaces, over 10cm girth, preparation of surfaces, applying two coats of 100% acrylic, weather resistant emlusion over a coat of exterior wall primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall & ceiling applying two coats of oil emlusion distemper over a coat wall care putty of 3mm thick and alkali primer complete all as specified and directed.
M&L for complete removal of existing treatment on wall surfaces and applying a coat wall care putty 3mm thick on plastered surfaces, preparatory to distempering and applying two coats of oil bound distemper over a coat of wall primer complete all as specified and directed..
Taking down old GI tubing 50/40/25 mm bore medium grade from trenches/wall/floor etc including making good the disturbed surfaces complete all as specified and directed.
Supply and fix GI tubes medium grade of 50 mm dia complete with all fittings (like; union, tee, bend, elbow, reducer, socket) to be fixed on wall and ceilings or laid in floors/trenches complete of following bore of pipes:-
All as per item 34 above but of size 40 mm dia
All as per item 34 above but of size 25 mm dia
All as per item 34 above but of size 20 mm dia
Material and labour for taking down unserviceable gun metal globe or gate valve of any size from existing location complete all as specified and directed..
Supply and fix gun metal gate valve, with iron wheel head screwed both ends for iron pipe of 50 mm bore incl provn of union nipples sockets etc.
All as per item 39 above but of 40 mm bore
All as per item 39 above but of 25 mm bore
All as per item 39 above but of 20 mm bore
S&F Rotational moulded polyethylene 1000 Ltr water storage tanks (cylindricaL) water storage tanks (cylindrical vertical tanks (cylindrical vertical with closed top) hoisted and fixed in positioncomplete all as specified and directed.
S&F Rotational moulded polyethylene 500 Ltr water storage tanks (cylindrical) water storage tanks (cylindrical vertical tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
Supply & fix 200 watt LED FLOOD Light: Orion3.0 Series ,SMD LED Flood Light with Pressure die-cast aluminium housing,complete with all accessories complete all as specified and directed. Make- C&S Cat part no-LTEF200WHPLED or equivalent in Havells/Philips/Bajaj.
S&F cable junction boxes IP 66/67 weather proof for out door installation(with knock outs cable entry junction box size should be 205x255x112 with terminals including complete all as specified and directed.. Make -Hensel cat part no-KF2525G or equivalent dutiavello/Bajaj.
Dismantling and taking out AC outdoor unit any capacity and Rexing complete all as specified and directed..
Supply and fixing and clamping jointing copper tubing for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete all as specified and directed.
Supply & DLP PVC trunking system and accessories-trunking and fittings,Bodies supplied with out cover 105 x 50 mm complete all as specified and directed. Cat part No -010422 of legrand or equivalent.
Supply & DLP PVC trunking system and accessories-trunking and fittings,Flexible cover fits into the whole branch including in internal or external angles supplied with Body cover 85 mm complete all as specified and directed. Cat part No-010522 of legrand or equivalent as approved by GE
Taking down carefully sub main wiring including batten/ conduit by unscrewing from wall,ceiling and making good surfaces to match with original status complete all as specified and directed.
S & F in replacement of MCB 2 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed..Make- Legrand cat part no- 408583/Siemens/GE
M & L in repair Submain wiring with two run 4 Sqmm 3 core core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including PVC non metallic conduit with Accessories fixed on wall/ceiling/truss etc including one run PVC insulated & unsheathed multistranded copper conductor 4Sq. mm FRLS grade ISI make as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed.
Dismantling and taking solar panel any capacity and Rexing .
SAI SERVICE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .