Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 CrAccepted-AOC PLOT NO HIG 7 CHUNVATI LANE GOPALGAN BALASORE 756001 | BALESHWAR | ODISHA | 756001 | ₹9.9 Cr | L1 | Accepted-AOC Being the lowest Bidder |
| 2 | L2₹10.2 Cr+₹34.5 L (3.49%)Rejected-Finance | ₹10.2 Cr+₹34.5 L (3.49%) | L2 | Rejected-Finance Not being the Lowest Bidder |
| 3 | L3₹11.6 Cr+₹1.8 Cr (17.9%)Rejected-Finance | ₹11.6 Cr+₹1.8 Cr (17.9%) | L3 | Rejected-Finance Not being the Lowest Bidder |
| 4 | L4₹13.2 Cr+₹3.3 Cr (33.5%)Rejected-Finance | ₹13.2 Cr+₹3.3 Cr (33.5%) | L4 | Rejected-Finance Not being the Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹21.1 L
Closing Date
10 Mar 2020, 3:00 pmClosed
Chief Construction Engineer R and D East
CCE R and D East Napier Road, PO-Hastings Kolkata, West Bengal
Provision of Area Drainage at ITR Technical Area Chandipur
2020_DRDO_545591_1
CCE R and D E/ENQ-76/CIV/BLS/2019-20
Limited
Civil Works
Item Rate
365 days
Chandipur
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
CCE (R and D)East
₹21.1 L
Yes
19 Jan 2021
18 Feb 2020
11 Mar 2020
19 Feb 2020
10 Mar 2020
3 Mar 2020
25 Feb 2020 - 2 Mar 2020
Amount
SUB HEAD-I - EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
SUB HEAD-II - CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work for :
Columns, piers, abutments, pillars, posts and struts
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.material in cement concrete per 50 kg
SUB HEAD-III - REINFORCED CEMENT CONCRETE
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 380 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All works above plinth level upto floor V level
Extra for providing richer mixes at all floor levels Note:- Excess/less cement over the specified cement content used is payable /recoverable separately.
Providing M-30 grade concrete instead of M-25 grade BMC/ RMC.(Note:- Cement content considered in M-30 is @ 400 kg/cum)
Add for using extra cement in the items of design mix over and above the specified cement content therein.
SUB HEAD-IV - BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm /300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
SUB HEAD-V - STEEL WORK
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
4.0 mm thick glass panes
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of Required size, joints mitred and welded by angle iron flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
SUB HEAD-VI - FLOORING
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
18 mm thick
Providing and fixing glass strips in joints of terrazo/ cement concrete floors
40 mm wide and 4 mm thick
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
Size of Tile 600x600 mm
SUB HEAD-VII - ROOFING
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,.(i) Single socketed pipes
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion
110 mm bend
Shoe (Plain)
110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
SUB HEAD-VIII- FINISHING
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :
1:4 (1 cement: 4 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand)
6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams.
Extra for providing and mixing water proofing material in cement .Per bag plaster work in proportion recommended by the manufacturers
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
Finishing walls with Rain coat paint made of Dr. Fixit or equivalent with following specifications: Surface Preparation: -All new cement-sand renderings/concrete surfaces should be allowed to age 6 to 8 weeks before surface coating. -Surface for treatment must be thoroughly cleaned of all laiance, loose material, oil grease, etc by mechanical means such as wire brushing & shot blasting. -Finally vacuum cleaning of all loose solids and liquids can be done, if required. Priming: Prime the surface with Dr. Fixit Primeseal or equivalent diluted with potable water by volume in 2:1 ration(2 parts primer and 1 part water) with a coverage of 10 Sqm per ltr and allow it to dry for 2 to 3 hours. Applying Base Coat: Applying one coat with brush or roller Dr. Fixit Raincoat Universal Base coat or equivalent with coverage of 8.0-9.0 Sqm per litre single coat.
SUB HEAD-IX - DISMANTLING AND DEMOLISHING
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
With cement mortar 1:4 (1 cement : 4 fine sand)
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles above 25 mm and up to 40 mm
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :
bituminous road
Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
SUB HEAD-X - ROAD WORK
Supplying and stacking at site.
90 mm to 45 mm size stone aggregate
63 mm to 45 mm size stone aggregate
53 mm to 22.4 mm size stone aggregate
Stone screening 13.2 mm nominal size (Type A)
Stone screening 11.2 mm nominal size (Type B)
Good earth
Moorum
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
Brick edging laid lengthwise with half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications :
On W.B.M. @ 0.75 Kg / sqm
Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete.
Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete.
New work (Two or more coats)
Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.
40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
75 mm thick back filling for pitching including supplying of required materials and consolidation etc. complete with :
Moorum
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 D grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
SUB HEAD-XI - DRAINAGE
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
SUB HEAD-XII - WATER PROOFING
Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Surface preparation:-Cleaning of RCC roof by removal of dust ,dirt,laitance,following by ponding will be done on the applicotion surface. Any surface cracks needs to be into U groove and sealing it with polymerin 1:4 ratio (cement: sand)admixed with Dr Fixit pidicrete URP at 5% byweight of cemen . All corner joints will be cut open, followed by sealing the same with the same polymer mortor all in compllete. Cemen ,sand, aggregate,water will be supplied by contractor.providing and applying "Dr Fixit Flexi PU 270(i) high performance pure root , seamless, waterproof memberance, appliedin 2 coats of totol Systems thickness of 1.50 mm and having an elangation capacity of over 500% , tensil strength of 4 N/mm2 .and the coating will be terminated up to 300 mm on theparapet wall, all in complete. providing and laying 120-150 gsm geotextile on the cured memberane surface providing and laying protective screed concrete (M20 grade ) with admixture of recomanded propertion and average 50 mm thick(thickness can varydepending up on span of area ) . All in complete (including welded mesh 2mm dia and 100mmX100mm aparture but M-20 Grade sceed will be paid separately)
SUB HEAD-XIII - Electric
Supply, installation testing and Commissioning of Mix flow pump model- MF 30-35, pump size350 x 300mm fitted with CI Casing CI Impeller,Impeller diameter, rated 396mm (approx.), Gland pack bar shaft pump or eqvl. Pump. Kirloskar/ bharat bijlee/ Lhp or eqvl. Make 75HP 986 rpm 3 Phase 415v, 50 Hz, TEFC foot mounted IE-2 induction motor, .with all necessary required items. MS Base Frame, tyre coupling with Guard
Cap- 1250cum/hr, Head - 12m ( 2 working +1 Stand by)
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329. Including push-on-joints, testing of joints and the cost of rubber gasket, nut bolt,washers etc as complete required .
350 mm dia Ductile Iron Double Flanged
500 mm dia Ductile Iron Double Flanged
700 mm dia Ductile Iron Double Flanged
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
350mm dia
Supplying, fixing, testing & commissioning of sluice valve of rating PN10/16 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 14846: 2000 of following sizes as required :
350mm dia
Supplying, fixing, testing & commissioning of swing type Foot valve of following sizes confirming to IS: 4038. comlete in all respects.
500mm dia
EARTHING
(a) Copper Plate Earthing Station
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing/ Laying following size of copper strip over DMC/ SMC insulators at an interval of 600mm including jointing with brass nut & bolts,heat shrinkable sleeve, brazing excavation and back filling of earth wherever required etc as complete.
40mm x 6mm cu Strip
Providing and fixing/ Laying following size of G.I. strip over DMC/ SMC insulators at an interval of 600mm including jointing with brass nut & bolts,heat shrinkable sleeve, brazing excavation and back filling of earth wherever required etc as complete.
25 mm X 5 mm G.I. strip
MISCELLANEOUS ITEMS
Supplying and placing of non-skid rubber mat suitable thickness confirming to IS- 15652 and 900 mm width as required including cutting to required lengths or approved make with test certificate for L.T panels.
Supplying and placing of non-skid rubber mat suitable thickness confirming to IS- 15652 and 900 mm width as required including cutting to required lengths or approved make with test certificate for H.T. 11-33 KV panels.
Supplying and fixing of shock restoration chart written in english and hindi duly framed in glass as required.
Supply, Install, test and commissioning 200KVA Silent Diesel Generating Set powered by with acoustic weather proof enclosure as per CPCB norms etc approved Make DG set 200kVA. Water cooled producing Suitable BHP at 1500RPM under NTP condition having Suitable Cylinder, 24 Volts electric start arrangement coupled to a 200 KVA III Phase Alternator of 0.8 power factor, 415 Volts , 50 c/s, 4 Wire on a common base frame with, starting battery (Two no) fuel tank & Silencer. ccomplete in all respects (a) ENGINE: Diesel engine developing suitable BHP1500 RPM turbo charged water cooled engine inclusive of the following standard accessories:-
(i) Radiator /radiator fan (ii) Spider coupling guard (iii) Fly wheel (iv) Fly wheel housing complete with starter gear ring and coupling (v) Fuel pipes (vi) Air cleaner (vii) Fuel and Lub oil filter (ix) Coolant inhibitor (x) Fuel pump (xi) water pump (xii) Lub oil pump (xiii) Electric starter 12 Volt DC (xiv) Battery charging generator (DC Alternator) (xv) Industrial Silencer (xvi) Lub oil cooler (xvii) Flexible pipe for silencer (xviii) DC Volt meter (xix) Water temperature guage, Lub oil pressure guage (xx)Speedo meter and engine running hours meter (xxi) Display for fault (xxii) Suitable size of turbo charger and suitable PCC foundation as per manufacturer recommendations and as directed by Engr-in-Charge. (b) ALTERNATOR: Synchronous alternator 3 phase 4 wire 50 cycles/second 1500 RPM self excited type 0.8 PF, 415 volts AC supply, 200 KVA capacity copper wound conforming to IS-4722 complete mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine Alternator suitable rated at 0.8 PF (Lag) 415V, 50HZ, at 1500RPM, Class H insulation, IP 23 Enclosure, self-excited and self-regulated with voltage regulation of + Â 1% of rated voltage from no load to full load.
MOTOR CONTROLPANEL
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA sheet for main frame and 1.6mm thick for partitions after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit with standing capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have atleast two spare cubicles to suit the highest rating outgoing MCCB. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. MCCBs 160A and above shall be with Micro processor based releases, All CTs/CBCT shall be resin cast type. All MCCBs shall be provided with spreader links and Rotary handles, complete in all respects. with Automatic main failure factory made control panel as per manufacture,spectification suitable for DG set cap 200 KVA
CABLE WORK
Supplying & laying of LT Aluminium conductor Power Cable of following sizes, 1100 volt grade XLPE insulated , PVC inner sheated, galvanised steel strip or wire armoured cable as per IS 7098(PART 1)1988 .
3.5 core 300Sqmm
Laying direct in ground including excavation, sand cushioning, protective covering by bricks and refilling the trench etc as required.
Laying and fixing on wall surface in existing RCC/ HUME/ METAL pipe as required.
Supplying & laying of LT Aluminium conductor Power Cable of following sizes, 1100 volt grade XLPE insulated , PVC inner sheated, galvanised steel strip or wire armoured cable as per IS 7098(PART 1)1988 .
4 core 16 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
CABLE END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 300 sq. mm (70mm)
4 X 16 sq. mm (28mm)
INTERNAL ELECTRIFICATION
Point wiring for Light / fan / Exhaust fan with 2 runs of 1100V grade 1.5 sq. mm & 1 run of 1.5 sq. mm FRLS insulated multistranded Copper wires, run in & including 25 mm dia , medium class PVC conduit concealed in wall after necessary chase cutting with finishing / surface on wall/ ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch and the box covered with front plate.
One Light point controlled by one 6A switch ).
Exhaust fan point controlled by one 6A switch including ceiling Rose.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed 25mm medium class PVC conduit as required
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supply, Installation, Testing & Commissioning of the following Light Fixture with lamp, Control Gear & All necessary accessories. Luminaries with all electrical accessories & it should be energy efficient, low loss, ortho cyclically wound open construction copper ballast, ignitor & power factor improvement capacitor or Electronics Ballast etc are prewired up to the terminal block & mounted on a removable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaries should be click fix & require use of no tools. Mounting options should be for both lateral as well as pole top mounting. with Lamp Control Gear & Fixing Accessories.
20W LED BATTEN LIGHT WALL/SURFACE MOUNTED MAKE-PHILLIPS CAT NO. BN108C 20S PSU CDL WH
35W Area Lights Uniflood MAKE-PHILLIPS CAT NO. -BVP120 LED 35 CW FG S1 PSU GR
Supply, Installation & testing of following Exhaust fan suitable for suitable for single phase 230/240V, AC Supply complete with motor MS louvers , mounting brackets, all accessories etc as complete.
450 mm dia metal body exhaust fan (Heavy Duty)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
SUB HEAD-XIV - SPECIAL ITEMS
Supply, Installing, testing & commissioning of cast iron side wall mounted on open channel sluice gate of size 2 mtr x 1.5 mtr opening, Flush bottom closure type, rising spindle type, bead stock, hand wheel with act water for automated operation, provision of manual operation also and PLC SCADA connectivity incluiding motorized system complete material of construction as required. MAKE KIRLOSKAR BROTHER LIMITED / AARKO MANUFACTURING COMPANY / ARROW ENGG. LIMITED Frame & Shutter - C.I. IS:210 FG 200 Rubber Seal - EPDM Rubber Retainer bar - SS ASTM A240 type 304 Stem - M.S. IS 2062 Grade A Fastners - M.S. IS 2062 Grade A Thrust Nut - Gunmetal Yoke - M.S. IS 2062 Grade A Head Stock & - C.I. IS:210 FG 200 Stem Guide In Addition other accessories where required including making connection with the electrical panal board complete in all respect CI Sluice Gates to be mounted on open Channel having size of 2 Mtr x 1.5 Mtrs
M.P.KHAITAN
Vishal Infrastructure Ltd
RVR PROJECTS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .