| 1 | L1₹19.5 LAccepted-AOC GALI NO 20 RAMPURA BASTI BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.9 L+₹14,825 (0.72%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹22.9 L+₹2.2 L (10.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹24.6 L+₹3.8 L (18.6%)Rejected-Finance 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹27.0 L+₹6.2 L (30.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Jain Traders L4 | DEMROT ELECTRICAL WORKS L7 | M/s SUNIL ENTERPRISES L11 | niranjan singh and company L3 | M/s Kishan Gopal Agarwal L10 | PD GUPTA AND COMPANY L8 | MITTAL ENTERPRISES L9 | M/S BALAJI SOLAR & AUTOMATION SERVICES L2 | ENGINEERS POWER CONSTRUCTION COMPANY L1 | KIRTIMAN TRADERS L5 | TARA CHAND JI GOMA CONSTRUCTIONS CO. L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting of unserviceable sub main wiring of any size including conduit of any type and accessories & removing from site and making good the disturbed surfaces complete all as specified and directed. | 1,900 | RM | 9 ₹17,100 | 5 ₹9,500 | 11 ₹20,900 | 5 ₹9,500 | 5 ₹9,500 | 5 ₹9,500 | 5 ₹9,500 | 3 ₹5,700 | 1 ₹1,900 Lowest | 5 ₹9,500 | 5 ₹9,500 |
| 2.00 | Disconnecting electric connections and taking down old unserviceable MCB DBS SPN of any size including MCBs SPN/SP of any capacity incl making good the disturbed surfaces complete all as specified and directed. | 540 | Each | 19 ₹10,260 | 20 ₹10,800 | 21 ₹11,340 | 25 ₹13,500 | 10 ₹5,400 | 10 ₹5,400 | 10 ₹5,400 | 8 ₹4,320 | 1 ₹540 Lowest | 5 ₹2,700 | 7 ₹3,780 |
| 3.00 | Disconnecting electric connections and taking down old unserviceable MCB DBs TPN of any size including MCBS TPN/SPN/SP of any capacity incl making good the disturbed surfaces complete all as specified and directed. | 115 | Each | 29 ₹3,335 | 50 ₹5,750 | 21 ₹2,415 | 50 ₹5,750 | 10 ₹1,150 | 10 ₹1,150 | 10 ₹1,150 | 8 ₹920 | 1 ₹115 Lowest | 5 ₹575 | 15 ₹1,725 |
| 4.00 | Disconnecting of unserviceable service connection of any size and removing from site and making good the disturbed surfaces complete all as specified and directed. | 2,400 | RM | 9 ₹21,600 | 10 ₹24,000 | 11 ₹26,400 | 5 ₹12,000 | 7 ₹16,800 | 5 ₹12,000 | 5 ₹12,000 | 3 ₹7,200 | 1 ₹2,400 Lowest | 5 ₹12,000 | 6 ₹14,400 |
| 5.00 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid FRLS conduits with conduits accessories incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/roof/ ceiling complete all as specified and directed.
Make of PVC conduit - Polycab/ Finolex/Legrand-MDS
Note: Two run of single core cable, one run of earth continuity conductor and 1 mtr PVC conduit shall be measured as one unit length. | 600 | RM | 189 ₹1,13,400 | 150 ₹90,000 | 325 ₹1,95,000 | 140 ₹84,000 | 260 ₹1,56,000 | 200 ₹1,20,000 | 249 ₹1,49,400 | 175 ₹1,05,000 | 130 ₹78,000 Lowest | 170 ₹1,02,000 | 130 ₹78,000 Lowest |
| 6.00 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable complete all as specified and directed.
Note: Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length. | 1,000 | RM | 179 ₹1,79,000 | 130 ₹1,30,000 | 285 ₹2,85,000 | 120 ₹1,20,000 Lowest | 225 ₹2,25,000 | 250 ₹2,50,000 | 199 ₹1,99,000 | 160 ₹1,60,000 | 130 ₹1,30,000 | 140 ₹1,40,000 | 130 ₹1,30,000 |
| 7.00 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid FRLS conduits with conduits accessories incl one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling complete all as specified and directed.
Make of PVC conduit - Polycab/ Finolex/Legrand-MDS
Note: Two run of single core cable, one run of earth continuity conductor and 1 mtr PVC conduit shall be measured as one unit length. | 1,000 | RM | 249 ₹2,49,000 | 200 ₹2,00,000 | 425 ₹4,25,000 | 180 ₹1,80,000 Lowest | 370 ₹3,70,000 | 250 ₹2,50,000 | 269 ₹2,69,000 | 190 ₹1,90,000 | 200 ₹2,00,000 | 210 ₹2,10,000 | 200 ₹2,00,000 |
| 8.00 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable complete all as specified and directed.
Note: Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length. | 500 | RM | 219 ₹1,09,500 | 180 ₹90,000 | 385 ₹1,92,500 | 170 ₹85,000 Lowest | 325 ₹1,62,500 | 250 ₹1,25,000 | 239 ₹1,19,500 | 180 ₹90,000 | 200 ₹1,00,000 | 170 ₹85,000 Lowest | 200 ₹1,00,000 |
| 9.00 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 10 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 10 Sqmm multi stranded copper conductor cable complete all as specified and directed.
Note: Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length | 300 | RM | 419 ₹1,25,700 | 250 ₹75,000 Lowest | 565 ₹1,69,500 | 260 ₹78,000 | 650 ₹1,95,000 | 450 ₹1,35,000 | 299 ₹89,700 | 295 ₹88,500 | 320 ₹96,000 | 280 ₹84,000 | 350 ₹1,05,000 |
| 10.00 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 10 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid FR conduits with conduits accessories incl one run of green colour earth continuity conductor with 10 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling, complete all as specified and directed.
Make of PVC conduit - Polycab/ Finolex/Legrand-MDS
Note: Two run of single core cable, one run of earth continuity conductor and 1 mtr PVC conduit shall be measured as one unit length. | 100 | RM | 449 ₹44,900 | 280 ₹28,000 Lowest | 601 ₹60,100 | 300 ₹30,000 | 600 ₹60,000 | 700 ₹70,000 | 349 ₹34,900 | 310 ₹31,000 | 350 ₹35,000 | 350 ₹35,000 | 370 ₹37,000 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
22 Dec 2025, 6:00 pmClosed
GE Nasirabad
GE Nasirabad Military Engineer Services Pin 305 601 Rajasthan
REPAIR/ REPLACEMENT OF SUB MAIN WIRING, SERVICE CABLES, MCB DBs, MCBs AND EARTHING AT NASIRABAD MIL STN UNDER GE NASIRABAD
2025_MES_742470_1
8617/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Nasirabad
As per Tender Documents
6 documents required · 6 mandatory
₹500
Yes
GE NASIRABAD
₹80,000
Yes
29 Jan 2026
2 Dec 2025
24 Dec 2025
2 Dec 2025
22 Dec 2025
16 Dec 2025
2 Dec 2025 - 16 Dec 2025
Amount
Disconnecting of unserviceable sub main wiring of any size including conduit of any type and accessories & removing from site and making good the disturbed surfaces complete all as specified and directed.
Disconnecting electric connections and taking down old unserviceable MCB DBS SPN of any size including MCBs SPN/SP of any capacity incl making good the disturbed surfaces complete all as specified and directed.
Disconnecting electric connections and taking down old unserviceable MCB DBs TPN of any size including MCBS TPN/SPN/SP of any capacity incl making good the disturbed surfaces complete all as specified and directed.
Disconnecting of unserviceable service connection of any size and removing from site and making good the disturbed surfaces complete all as specified and directed.
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid FRLS conduits with conduits accessories incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/roof/ ceiling complete all as specified and directed. Make of PVC conduit - Polycab/ Finolex/Legrand-MDS Note: Two run of single core cable, one run of earth continuity conductor and 1 mtr PVC conduit shall be measured as one unit length.
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note: Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length.
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid FRLS conduits with conduits accessories incl one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling complete all as specified and directed. Make of PVC conduit - Polycab/ Finolex/Legrand-MDS Note: Two run of single core cable, one run of earth continuity conductor and 1 mtr PVC conduit shall be measured as one unit length.
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note: Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length.
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 10 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 10 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note: Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 10 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid FR conduits with conduits accessories incl one run of green colour earth continuity conductor with 10 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling, complete all as specified and directed. Make of PVC conduit - Polycab/ Finolex/Legrand-MDS Note: Two run of single core cable, one run of earth continuity conductor and 1 mtr PVC conduit shall be measured as one unit length.
S&Fin repair of MCB distribution board single pole & neutral IP-43 double door metal, 240 volt made out of CRCA sheet steel, factory made powder coated with insulated bus bars, shrouded neutral bars, earth bars, made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCB's complete all as specified and directed of following size: Note: MCB DB and MCB SP/SPN will be of same make.
08 Ways, 240 volts SPN
12 Ways, 240 volts SPN
04 Ways, 240 volts SPN
S&F in repair of MCB distribution board triple pole & neutral IP-43 double door metal, 4 way 415 volt made out of CRCA sheet steel, factory made powder coated with insulated bus bars, shrouded neutral bars, earth bars, made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCB's complete all as specified and directed. Note: MCB DB and MCB SP/SPN will be of same make.
S&F in repair of vertical TPN distribution board, IP-43 double door metal, 4 way, made out of CRCA sheet steel, factory made powder coated with insulated vertical phase bus bars, shrouded neutral bars, earth bars, colour coded interconecting wire set, blanking plates suitable for up to 125 amp MCCB's as incomer and MCB's SP/TP as outgoing complete all as specified and directed.
S & F of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
S & F of MCB SP, 240 volt, 63 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
Supply and fixing of MCB SPN, 240 Volt, 32 Amp capacity, 10KA, 'C' curve complete all as specified and directed.
Supply and fixing of MCB SPN 240 Vol, 63 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
Supply and fixing of MCB TPN 63 Amp capacity, 415 volt, 10 KA, 'C' curve complete all as specified and directed.
Supply and fixing of MCB TPN 100 Amp capacity, 415 volt, complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular 16 sqmm complete all as specified and directed.
All as per item no 20.00 here-in-before but of size 10 sqmm twin core.
All as per item no 20.00 here-in-before but of size 6 sqmm twin core.
M & L for earthling complete with Gl earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to Gl lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade Gl pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh incl dismantling old unsv earthing complete all as specified and directed. Note : The unit rate includes for protection pipe and Gl wire 4.00 mm from top of earth plate up to 7.5 meter above ground level.
M & L for earthling complete with Gl earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to earth lead 32x6 mm galvanised iron strip dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth lead protection by 40 mm dia medium grade Gl pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh incl dismantling old unsv earthing complete all as specified and directed. Note : The unit rate includes for protection pipe and Gl strip 32x6 mm from top of earth plate up to 7.5 meter above ground level.
Supply and fix in repair house house service bracket hook type complete with 3 mtr long Gl pipe 40 mm dia med grade, two nos 90° bracket, MS hook and stay or guy complete all as specified and directed
Supply and fix Gl lead wire 4.00 mm as earth continuity conductor beyond 7.5 mtr fixed to wall or RM burried in ground or drawn in pipe complete all as specified and directed
Supply and fix Gl strip 32x6 mm as earth continuity conductor beyond 7.5 mtr fixed to wall or RM burried in ground or drawn in pipe complete all as specified and directed
M/S BALAJI SOLAR & AUTOMATION SERVICES (BID ID -3515089)
niranjan singh and company (BID ID -3514866)
Jain Traders (BID ID -3513411)
KIRTIMAN TRADERS (BID ID -3512080)
TARA CHAND JI GOMA CONSTRUCTIONS CO. (BID ID -3515044)
DEMROT ELECTRICAL WORKS (BID ID -3514666)
PD GUPTA AND COMPANY (BID ID -3515139)
MITTAL ENTERPRISES (BID ID -3515313)
M/s Kishan Gopal Agarwal (BID ID -3514917)
M/s SUNIL ENTERPRISES (BID ID -3514809)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
GeneralPages8617.pdf
Tender Documents • 0.92 MB
BOQ_831424.xls
BOQ • 1.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .