Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC | ₹26.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹26.7 L+₹3,005 (0.11%)Rejected-AOC | ₹26.7 L+₹3,005 (0.11%) | L2 | Rejected-AOC L2 |
Tender Value
₹26.7 L
EMD Value
₹53,324
Closing Date
30 Jul 2024, 2:00 pmClosed
Executive Engineer, PWD C.C. Division
O/O The E.E. PWD C.C. Division, Dispur
Construction of 2 (Two) nos.of watch tower by providing steel structure at Minister Colony, Dispur, Guwahati-6
2024_PWBNH_37956_1
CS/414/2023-24/10031
Open Tender
Civil Works - Building
Item Rate
21 days
Dispur
Please refer Tender documents.
4 documents required · 4 mandatory
₹533
₹53,324
Yes
Dispur
27 Sept 2024
11 Jul 2024
1 Aug 2024
12 Jul 2024
30 Jul 2024
17 Jul 2024
16 Jul 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for, Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size of Recycled Concrete Aggregate (RCA) upto 20%
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/ m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m²
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). 6 mm thick Cement fiber board as per IS: 14862
Applying priming coat: With ready mixed pink or Grey primer of approved brand and anufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
Supply, installation Testingand Commissioning of 1200mm sweep BEE 5 star rated, ceiling fan with Brush Less Direct ccurrent (BLDC) Motor class of insulation B 3 nos. blade ,30cm long down rod, 2 nos. canopies shackle kit safety rope copper winding, Power Factor not less than 0.9 service value (CMM/W) minimum 6.85, Air deliveery minimum 215CMM, 350RPM (Tolerance as per IS 374-2010 THD less than 10% remote or electronic.regulator unit ofr speed contron and all remaining accessories incluidng safety in, nut,bolts washers, temperature rose =75 degree C (max) insulation resistance more that 2 mega ohm, suitale for 230 v, 50Hz single phase AC supply earting etc. complete as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 6 way, Double door SPN MCBDB
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c cutting and making good the wall etc. Internal work- Exposed on wall
Supplying , installation , testing and commission of ALUMINIUM CABLES 3 CORE 6 SQMM complete with all accessoriies with necessary as required and as directed by the Department GLOSTER 6 sq.mm x 3 Core PVC Aluminium Cable
Supplying installation, testing and commission of Designer LED floor light with efficacy 110 Lm/W and high pressure die cast alumium hosing (for 110 & 140W ) complete with all accessories iwith necessary as required and as directed by the department Flood Light 120W (LFLD03S120XC)
Bhaben Ch Deka
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .