| 1 | L-1₹27.6 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹32.1 L+₹4.5 L (16.2%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹33.5 L+₹5.9 L (21.3%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹43.7 L+₹16.1 L (58.5%)Rejected-Finance | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹50 L+₹22.4 L (81.2%)Rejected-Finance | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
19 Sept 2023, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIR AND REPLACEMENT OF INTERNAL WIRING WITH REPLACEMENT OF FITTING AND FIXTURES, DB S, SUB MAIN WIRING, METER BOXES AND SERVICE CABLES IN ZONE B AT DAMANA UNDER GE JAMMU
2023_MES_615441_1
GEJC-64/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Jammu
₹1 L
Yes
10 Oct 2023
24 Aug 2023
21 Sept 2023
24 Aug 2023
19 Sept 2023
7 Sept 2023
Amount
Taking down old unserviceable copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden / iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid / steel conduit and into existing CI / pressed steel sunken / terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Notes: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description same as per Ser Item No 02.00 here-in-before but for one 5 pin socket outlet 5 amps on the same board complete all as specified and as directed.
Description same as per Ser Item No 02.00 here-in-before but for one 5 pin socket outlet, 5 amps, independent complete all as specified and as directed.
Description same as per Ser Item No 02.00 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness conduit ISI marked including new CI / pressed steel sunken / terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Notes: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description same as per Ser Item No 06.00 here-in-before but for 5 Amp socket outlet on same board complete all as specified and as directed.
Description same as per Ser Item No 06.00 here-in-before but for socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.
Description same as per Ser Item No 06.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness conduit ISI marked including pressed steel sunken / terminal boxes with existing colour terminated boxes of modular metal flush boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following: - Notes: - (a) Suitable module white cover sheets with frame as specified to be provided in replacement to mild steel / Galvanised sunken boxes and shall be measured and paid separately as per relevant item. (b) Wiring shall be done by using proper colour coding. (c) Earth wire shall be of green colour. (d) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description same as per Ser Item No 10.00 here-in-before but for 5 Amp socket outlet on same board complete all as specified and as directed.
Description same as per Ser Item No 10.00 here-in-before but for socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.
Description same as per Ser Item No 10.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Supply and fixing in replacement modular switch 1 way 6 A, 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement socket 6A / 16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular metal flush box 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 3 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular metal flush box 4 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular metal flush box 6 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular metal flush box 8 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 2 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 3 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 4 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 6 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 8 module, 240 volts ISI marked complete all as specified and as directed.
Material and labour for replacement distribution board, double door, made of 2mm thick stainless steel sheet, powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement distribution board, double door, made of 2mm thick stainless steel sheet, powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement distribution board, double door, made of 2mm thick stainless steel sheet, powder coated for MCB with copper bus bar and neutral link earthing stud SPN 6 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement distribution board, double door, made of 2mm thick stainless steel sheet, powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement SPN 32 Amp rating 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement of Vertical Distribution Board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCB's and should be IP-43 protected with Copper Bus Bars, Neutral Links, Earthing bar complete all as specified and directed including taking down old unserviceable distribution board / MCB any type. Notes:- (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 volts with adjustable thermal settings. (ii) MCB's shall be measured and paid separately. (iii) TPN distribution board and MCCB should be of same make.
Supply and fixing in replacement for switch piano, flush type single pole one way 5 Amp, 240 volts complete all as specified and as directed.
Supply and fixing in replacement socket outlet 2 in 1, 3 pin, 5 A complete all as specified and as directed.
Supply and fixing in replacement switch socket outlet combined 5 pin 5 amp flush type, 240 volts complete all as specified and as directed.
Supply and fixing in replacement switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 Volts complete all as specified and as directed.
Supply and fixing in replacement for modular bell push 2 module, single pole, 5 Amp, 240 volts complete all as specified and as directed.
Supply and fixing in replacement ceiling rose 3 terminal surface type complete all as specified and as directed.
Material and labour in replacement for lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Material and labour in replacement self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
Supply and fixing in replacement LED light fitting 1 x 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95, 100 Lumen / Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable and flexible pipe of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts 50 Hz complete all as specified and as directed.
Supply and fixing in replacement LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable and flexible pipe of suitable size complete all as specified and as directed.
Supply and fixing in replacement wall mounted decorative type luminaries IP-65 with diffuser 10 watt, 230 Volts LED type complete with 10 watt LED bulb complete all as specified and as directed by Engineer-in-Charge. Note: - The cost of LED lamp, 10 watt deemed to be included in the quoted rate.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof, ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and as directed.
Supply and fixing in replacement calling bell Ding Dong / buzzer AC 230 Volts, single pole complete all as specified and as directed.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 6.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding. Three runs of 3 Sqmm cable along with conduit shall be termed as one unit.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 2.5 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding. Three runs of 2.5 Sqmm cable along with conduit shall be termed as one unit.
Material and labour in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 2.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding. One run of 2.5 Sqmm cable along with conduit shall be termed as one unit.
Material and labour in replacement for earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed.
Supply and fixing in replacement plug top 15 Amps complete all as specified and as directed.
Supply and fixing in replacement of Vertical Distribution Board (TP&N) 4 way suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCB's and should be IP-43 protected with copper bus bars, neutral links, earthing bar complete all as specified and directed including taking down old unserviceable distribution board / MCB any type. Notes: - (i) Rate includes MCCB four pole, 125 Amp, 16 KA, 415 Volts with adjustable thermal settings. (ii) MCB's shall be measured and paid separately. (iii) TPN Distribution board and MCCB should be of same make.
Material and labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge.
Material and labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 6 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge.
Material and labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 4 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep in any type of soil and getting out for underground cable / erection of poles, stays etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for sand cushioning for cable with river washed sand and punning to provide required cover as per SSR Part-I complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying bricks common burnt clay sub class 'B' old size for cable protection complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material not exceeding 50 metre away and depositing where directed at a level not exceeding 1.5 metre above from the starting point complete all as specified and as directed by Engineer-in-Charge.
Disconnecting and taking out defective underground cable any size and any type from trenches, roof, pole, pipe, floor, wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 Sqmm 4.0 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 Sqmm 4.0 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 25 Sqmm 3.5 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 35 Sqmm 3.5 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Disconnecting and taking out defective service cable any size and any type from roof, pole, pipe, floor, wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 Sqmm 2 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 Sqmm 2 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and fixing in repair MCCB with sheet steel enclosure 415 V, 4 pole, 125 Amps capacity, thermal magnetic, over current settings fixed on walls for electric supply distribution to buildings including necessary connection of cables from LT poles / panels to MCCB's complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair MCCB with sheet steel enclosure 415 V, 4 pole, 160 Amps capacity, thermal magnetic, over current settings fixed on walls for electric supply distribution to buildings including necessary connection of cables from LT poles / panels to MCCB's complete all as specified and as directed by Engineer-in-Charge.
THAPA TRADERS
M/S PRAJAPATI ENGINEERS
Shri Karshni Builders
Sarbat Construction Co
M/s Sahib Construction and engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .