GE Narangi
GE Narangi c/o 99 APO
SPECIAL REPAIR OF DB BOX, EARTHING, SUBMAIN WIRING AT B, C, D AND E BLOCK AND PROVN OF STORAGE SHED AT BSO YARD UNDER GE NARANGI
2026_MES_795440_1
8298/B/E8
Open Tender
Civil Works
Item Rate
180 days
Guwahati
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Narangi
₹95,200
Yes
23 Oct 2026
23 Oct 2026
14 Nov 2026
23 Oct 2026
12 Nov 2026
6 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed.
Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit. | 500 | Rm | - | - |
| - | M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed.
Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit. | 2,500 | Rm | - | - |
| - | S&F in repair for factory made, sheet steel distribution boards, TPN, 4 Way, double door,with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as directed. | 31 | Each | - | - |
| - | Supply fix in repair MCB DB of sheet metal enclosure double door SPN 8 way with 200 A rated bus bar and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as directed. | 80 | Each | - | - |
| - | Supply & fix in repair MCCB DB IP-43 of sheet metal enclosure double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified. | 72 | Each | - | - |
| - | S&F in repair MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and directed. | 995 | Each | - | - |
| - | S&F in repair/replacement MCBs, SPN 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and directed. | 80 | Each | - | - |
| - | S&F in repair/replacement MCB Tripple pole & neutral 40 to 100 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series rupturing capacity providing in DB complete all as specified. | 31 | Each | - | - |
| - | S&F in repair for MCCBs 415 V, 16 KA, 4P, 63 Amps complete all as directed. | 72 | Each | - | - |
| - | Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009. | 90 | Each set | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_892140.xls
BOQ • 0.55 MB
8298Tender.pdf
Tender Documents • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .